• Title/Summary/Keyword: 3D(three-dimensional)

Search Result 4,304, Processing Time 0.034 seconds

Design of QCA Latch Using Three Dimensional Loop Structure (3차원 루프 구조를 이용한 QCA 래치 설계)

  • You, Young-Won;Jeon, Jun-Cheol
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.2
    • /
    • pp.227-236
    • /
    • 2017
  • Quantum-dot cellular automata(QCA) consists of nano-scale cells and demands very low power consumption so that it is one of the alternative technologies that can overcome the limits of scaling CMOS technologies. Various circuits on QCA have been researched until these days, a latch required for counter and state control has been proposed as a component of sequential logic circuits. A latch uses a feedback loop to maintain previous state. In QCA, a latch uses a square structure using 4 clocks for feedback loop. Previous latches have been proposed using many cells and clocks in coplanar. In this paper, in order to eliminate these defects, we propose a SR and D latch using multilayer structure on QCA. Proposed three dimensional loop structure is based on multilayer and consists of 3 layers. Each layer has 2 clock differences between layers in order to reduce interference. The proposed latches are analyzed and compared to previous designs.

Feasibility of Novel Three-Dimensional Magnetic Resonance Fingerprinting of the Prostate Gland: Phantom and Clinical Studies

  • Dongyeob Han;Moon Hyung Choi;Young Joon Lee;Dong-Hyun Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1332-1340
    • /
    • 2021
  • Objective: To evaluate the feasibility of a new three-dimensional (3D) MR fingerprinting (MRF) technique for the prostate gland by conducting phantom and clinical studies. Materials and Methods: The new 3D MRF technique used in this study enables quick data acquisition and has a high resolution. For the phantom study, the MRF T1 and T2 values in an in-house phantom were compared with those of goldstandard mapping methods using linear regression analysis. For the clinical study, we evaluated 90 patients who underwent prostate imaging with MRF for suspected prostate cancer between September 2019 and February 2020. The mean T1 and T2 values were compared in the peripheral zone, transition zone, and focal lesions using paired t tests. The differences in the T1 and T2 values according to cancer aggressiveness were evaluated using one-way analysis of variance. Results: In the phantom study, the MRF T1 and T2 values showed a perfect correlation with the gold-standard T1 and T2 values (R > 0.99). In the clinical study, the T1 and T2 values in the peripheral zone were significantly higher than those in the transitional zone (p < 0.001, both). The T1 and T2 values in prostate cancer were significantly lower than those in the peripheral and transitional zones. The higher the grade of cancer, the lower the T2 values. Conclusion: The T1 and T2 values obtained from the 3D MRF showed a perfect correlation with the gold standard values in the phantom study. Differences in the T1 and T2 values among the different zones of the prostate gland were identified using 3D MRF in patients.

Analysis of Hydraulic Characteristics Upstream of Dam and in Spillway Using Numerical Models (수치모형을 이용한 댐 상류 및 여수로 수리현상 해석)

  • Kim, Young-Han;Oh, Jung-Sun;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.761-776
    • /
    • 2003
  • Numerical models were employed to investigate the hydrodynamics of water flow in the lake behind a dam and the spillway where supercritical flows and negative pressures are likely to occur. In this study, 2-D model, RMA2 was employed to examine the upstream flow pattern and 3-D CFD model, FLUENT was used to evaluate the three-dimensional flow in the approaching region and flow distributions in the spillways and discharge culverts. The bathymetry and the details of structures were carefully taken into consideration in building the models. The results from applying the 2-D model for the planned Hantan River Dam show that large eddies, the velocity of which reaches up to 1 m/s are occurring in several places upstream of the dam. That means that the 2-D numerical model could be utilized to investigate the two-dimensional flow patterns after the construction of a dam. Three-dimensional numerical results show that the approach flow varies depending on stages and discharge conditions, and velocities at spillways, discharge culverts, and sediment flushing tunnels are differently distributed. The velocity distributions obtained from the numerical model and a hydraulic model at the centerline of spillways 100 m upstream of the dam show reasonably similar results. It is expected that 2-D and 3-D numerical models ate useful tools to help optimize the dam design through investigating the flow patterns in the spillway and at the upstream of the dam, which is not always feasible in hydraulic modeling.

A Simplified Method for Determining Modal Strain Energy Release Rate of Free-Edge Delaminations in Laminated Composite (적층복합재의 자유단 박리에 대한 모드별 스트레인 에너지해방률의 간이계산법)

  • Kim, Taek-Hyun;Oh, Taek-Yul;Kim, In-Kweon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.423-429
    • /
    • 1997
  • A simplified method for determining the mode components of the strain energy release rate of free-edge delaminations in laminated composite is proposed. The interlaminar stresses are evaluated as an interface moment and interface shear forces that are obtained from the equilibrium equations at the interface between the adjacent layers. Deformation of an edge-delaminated laminate is calculated by using a generalized quasi-three dimensional classical laminated plate theory developed by the authors. The analysis provides closed-form expression for the three components of the strain energy release rate. Comparison of results with a finite element solution using the virtual crack closure technique shows good agreement. In the present study, laminated composite with stacking sequences of [30/-30/90]$_{s}$ were examined. The simple nature of the method makes it suitable for primary design analysis for the delaminations of laminated composite.e.

Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement (손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구)

  • Park, Sun Ha;Park, Ji-Hyuk;Kim, Jong Bae;Jung, Young Jin;Lee, Joo Hyun;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.1
    • /
    • pp.79-92
    • /
    • 2023
  • Objective : This study aimed to assess the reliability of a three-dimensional (3D) motion analysis program for measuring the range of motion (ROM) of wrist and finger joints. Methods : The study recruited 50 people who had no restrictions on wrist and finger movements, understood the purpose of this study, and agreed to participate. Using a goniometer and a 3D motion analysis program, a total of 11 wrist and finger ROM were measured once each. To measure the reliability of the 3D motion analysis program, the degree of agreement and inconsistency of the measured values were compared. Results : Analysis of the degree of agreement of the measured values revealed that 38 out of 44 items showed a very high degree of agreement. Regarding analysis of inconsistency in the measured values, inconsistencies were found in three items. Conclusion : The results of this study confirmed that the ROM of the joint could be measured using the 3D motion analysis program applied in this study. In addition, it might be expected that the 3D motion analysis program would be used in various clinical fields owing to the advantages of measurement convenience and accuracy.

A Study on depth analysis for S3D animation (S3D 애니메이션 제작을 위한 입체 값 분석 기술)

  • Kim, Sang-hoon;hwan, Moon suk
    • Journal of Digital Contents Society
    • /
    • v.16 no.4
    • /
    • pp.645-650
    • /
    • 2015
  • In this paper, we propose the method for creating a stable stereoscopic 3D contents with the production guidelines by removing the excessive depth value and scene changes for high quality. We have developed a three-dimensional depth analysis tool for detecting the scene changes out of the production guidelines and the depth value changes excessively. The Scenes detected by depth analysis tool can be modified at the post production and it helps to make a stable stereoscopic 3D contents.

The Effect of Spatial Dimension Shifts in Rotated Target Position Search (차원 변환이 회전하는 목표 자극의 위치 탐색에 미치는 영향)

  • Park, Woon-Ju;Jung, Il-Yung;Park, Jeong-Ho;Bae, Sang-Won;Chong, Sang-Chul
    • Korean Journal of Cognitive Science
    • /
    • v.22 no.2
    • /
    • pp.103-121
    • /
    • 2011
  • This study investigated how spatial dimension information and dimensional consistency between learning and testing phase would influence the target search performance. The participants learned spatial layouts of Lego blocks shown in either two- (2D) or three-dimension (3D) and were tested with the rotated stimuli ($0^{\circ}$, $90^{\circ}$, $180^{\circ}$, or $270^{\circ}$ from the initial view) in consistent or inconsistent dimension. Significantly better performance was observed when initial learning display appeared in 2D than in 3D. Particularly, the participants showed difficulties in flexible usage of spatial information presented in 3D especially if the dimensional information in the testing phase also was 3D and required mental rotation. The present study indicates that spatial map presented in 2D may be more useful than 3D in driving situations in which acquired spatial information from navigating device, such as GPS, and location of driver continuously changes.

  • PDF

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Food 3D-printing Technology and Its Application in the Food Industry (식품 3D-프린팅 기술과 식품 산업적 활용)

  • Kim, Chong-Tai;Maeng, Jin-Soo;Shin, Weon-Son;Shim, In-Cheol;Oh, Seung-Il;Jo, Young-Hee;Kim, Jong-Hoon;Kim, Chul-Jin
    • Food Engineering Progress
    • /
    • v.21 no.1
    • /
    • pp.12-21
    • /
    • 2017
  • Foods are becoming more customized and consumers demand food that provides great taste and appearance and that improves health. Food three-dimensional (3D)-printing technology has a great potential to manufacture food products with customized shape, texture, color, flavor, and even nutrition. Food materials for 3D-printing do not rely on the concentration of the manufacturing processes of a product in a single step, but it is associated with the design of food with textures and potentially enhanced nutritional value. The potential uses of food 3D-printing can be forecasted through the three following levels of industry: consumer-produced foods, small-scale food production, and industrial scale food production. Consumer-produced foods would be made in the kitchen, a traditional setting using a nontraditional tool. Small-scale food production would include shops, restaurants, bakeries, and other institutions which produce food for tens to thousands of individuals. Industrial scale production would be for the mass consumer market of hundreds of thousands of consumers. For this reason, food 3D-printing could make an impact on food for personalized nutrition, on-demand food fabrication, food processing technologies, and process design in food industry in the future. This article review on food materials for 3D-printing, rheology control of food, 3D-printing system for food fabrication, 3D-printing based on molecular cuisine, 3D-printing mobile platform for customized food, and future trends in the food market.

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.