Development of LVDT-Based Measuring System of the Cylinder Liner Wear for Marine Diesel Engines and Its Performance Evaluation (LVDT를 이용한 선박용 디젤 엔진의 실린더 라이너 마모 계측시스템 개발 및 성능평가)

  • Ha, Yun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.829-834
    • /
    • 2011
  • This paper introduces a new system which measures abrasion quantity of cylinder liners of large-scale marine diesel engines. The proposed system consists of three parts; measurement part where an LVDT, a temperature sensor, a camera and LED for lighting control are installed, monitoring part which accomplishes measurement command transmission and monitoring based on PC or notebook, and master control part which controls the measurement part and transfers measurement data to the monitoring part. The accuracy of the developed system is compared with that of an internal micrometer with 1/100 mm accuracy.

Large Scale Geographic Information Acquisition by Radio Control Aerial Photogrammetry (원격조종 공중사진측량에 의한 대축척 지형정보 획득)

  • 강준묵;배연성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • In this study, we try to develope the radio control photographing system with 35 mm camera to obtain 3-dimension large scale geographic information more effectively, to automatize and computerize the basic design and practical design of road. By applying this system on getting data which is needed to design road, this study has an object to promote efficiency in possesion and management of geographic information. As result of this study, this system could obtain geographic information effectively on the object region, could get large scale geographic information which was suitable for expected accuracy by photographing in 400 m height and could ac-quire profile, crossection and earth-work volume quickly and exactly.

  • PDF

Evaluation of Image Quality by Parameter Change in Onco Flash (Onco Flash에서 매개변수 변화에 따른 영상의 질 평가)

  • Cha, Eun-Sun;Noh, Ik-Sang;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.30-34
    • /
    • 2009
  • Purpose: Many companies developed a lot of programs with continuous effort for program upgrading. With this acquire superior image quality for the purpose of quick examination and progress in spatial resolution. This study was to obtained clinical usefulness on a appropriate parameter of FWHM for speed and alpha value for superior image quality. Materials and Methods: Gamma camera by Siemens (e.cam) and spatial resolution phantom and four quadrant bar phantom used. Compared for FWHM by changed scan speed 15, 20, 25, 30, 35, 40 cm/min in scatter and non scatter in Onco Flash of spatial resolution phantom. Visual evaluation of count rate and bar phantom image for increased of alpha value of 10% in 0~100%. Results: FWHM by the scan speed was 9.37, 9.40, 9.28, 9.30, 9.31, 9.53 mm in the scatter. Count rate increased alpha value 10% increased. Visual evaluation was suitable to below 30%, Therefore spatial resolution improved on FWHM at the scan speed 25~35 cm/min applying for alpha value 30% in Onco Flash was average 9.3 mm less than FWHM of below 15 cm/min and above 40 cm/min. Conclusion: We found on appropriate parameter to progress of image quality. And there be a useful guideline for you that appropriate scan speed on vary in parameters of reduction on examination time and advancing image quality.

  • PDF

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

Characteristics of pi-shaped Ultrasonic Motor (TT형 초음파 모터의 특성평가)

  • Yun, Yong-Jin;Park, Sung-Hee;Kang, Sung-Hwa;Lim, Ki-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.189-190
    • /
    • 2005
  • 본 논문에서는 카메라폰용 광학줌(Optical zooming)과 자동초점조절장치(Auto Focusing,AF)에 쓰일 초음파모터를 제작하였다. 초음파모터의 제작 및 시뮬레이션은 유한요소해석 프로그램인 ATILA 5.2 1(Magsoft co.)를 사용하여 디자인설계에 따른 구동특성을 고찰하였고 제작된 초음파모터는 한쪽 면이 없는 사작형의 탄성체를 제작하였으며 탄성체의 양쪽 다리에 각각 압전체를 부착하였다 또한 압전세라익의 조성은 0.9Pb$(Zr_{0.51}Ti_{0.49})O_3$ - 0.1Pb$(Mn_{1/3}Nb_{1/3}Sb_{1/3})O_3$ 의 조성으로 설계하였고 시편의 제조는 7-layer로 적층하였다. 제작된 압전세라믹의 치수는 6*2*0.35mm$^3$(길이*폭*두께)로 제작하였다. 또한 탄성체의 외형치수는 8*4*2mm$^3$로 제작하였으며 회전축의 지름은 2mm로 제작하였다. 인가전압과 공진주파수가 각각 20Vpp, 64kHz일 때 소비전력은 0.3[W]이며 회전속도는 500rpm 으로 측정되었다.

  • PDF

Local Behaviour of Propagating Flames in an Explosion Chamber (폭발챔버에서 전파하는 화염의 국부 거동)

  • Park, Dal-Jae;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.32-35
    • /
    • 2011
  • Experimental studies were carried out in an explosion chamber to investigate the influences of multiple cylinder obstacles on local flame propagation. The chamber dimension is 235 mm in height with a $1,000{\times}950\;mm^2$ rectangular cross section and a large vent area of $1,000{\times}320\;mm^2$. Multiple cylinder bars with obstruction ratio of 30% were used. In order to examine the interaction between the propagating flames and the obstacles, temporally resolved flame front images were recorded by a high speed video camera. The propagation behaviour of local flame fronts around the left obstacle was analyzed in terms of two different methods such as the incremental burnt area divided by the flame front length and the average of the local propagation velocity determined at each point along the flame front. It was found that two methods give good consistency.

망원경 제어해석 모형 개발 I. 김해천문대 200mm 굴절망원경의 제어 특성과 모형

  • Gang, Yong-U;Lee, Sang-Hyeon;Na, Ja-Gyeong;Kim, Gwang-Dong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.37.1-37.1
    • /
    • 2010
  • 망원경을 사용하여 천체를 관측할 때, 관측할 천체가 있는 위치로 망원경을 정확히 구동하여야 하고, 관측하는 시간 동안 충분히 정확히 추적하여야 한다. 그러나, 망원경은 다양한 재질의 많은 종류의 기계적인 부품들을 조립하여 만들어져 있기에, 필연적으로 기계적인 오차를 가지고 있다. 망원경 구동제어 장치는 수학 연산과 다양한 펄스 특성에 기인한 제어 오차를 가지고 있다. 그리고, 영상을 획득하는 부분은 시간 지연과 상의 왜곡이나 전자적인 잡음의 영향을 받는다. 또한, 바람이나 진동 등 예기치 않은 외부적인 요인에 의한 오차가 유발되기도 한다. 이러한 다양한 요인들로 인하여, 망원경이 천체를 정확히 찾아가고 추적하는 것을 어렵게 만든다. 우리는 자동제어공학에서 사용하는 제어해석 기법을 사용하여 망원경 제어 모형을 만들어 나가고자 한다. 특정 망원경에 있어, 오차 유발에 어느 요인이 가장 큰 영향을 주는지, 또한, 어떤 특성을 조절하고, 어느 정도의 제어 시간 간격을 주어야 하는지 등, 추적오차에 주는 영향들을 정량적으로 분석하고 제어에 반영하여 가장 최적의 제어를 할 수 있도록 하고자 한다. 그 첫번째 시도로, 김해천문대 독일식 적도의 방식 200mm 망원경과 이전 연구에서 개발한 PLC 기반의 망원경 제어 장치(강용우 외, 2008) 및 AP8 CCD 카메라를 사용하여, 지향 및 추적 관측 실험을 하였다. 그 결과를 분석하여 경험적 제어 모형을 만들고, 그 해석을 수행한 내용을 소개하고자 한다.

  • PDF

High Frame Rate CMOS Image Sensor with Column-wise Cyclic ADC (컬럼 레벨 싸이클릭 아날로그-디지털 변환기를 사용한 고속 프레임 레이트 씨모스 이미지 센서)

  • Lim, Seung-Hyun;Cheon, Ji-Min;Lee, Dong-Myung;Chae, Young-Cheol;Chang, Eun-Soo;Han, Gun-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • This paper proposes a high-resolution and high-frame rate CMOS image sensor with column-wise cyclic ADC. The proposed ADC uses the sharing techniques of OTAs and capacitors for low-power consumption and small silicon area. The proposed ADC was verified implementing the prototype chip as QVGA image sensor. The measured maximum frame rate is 120 fps, and the power consumption is 130 mW. The power supply is 3.3 V, and the die size is $4.8\;mm\;{\times}\;3.5\;mm$. The prototype chip was fabricated in a 2-poly 3-metal $0.35-{\mu}m$ CMOS process.

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

Evaluation of Nuclear Medicine Applications of 3D Printing Phantom - Gamma Camera Centrically (3D 프린팅 팬텀의 핵의학분야 적용 평가 - 감마카메라 중심으로)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose 3D 프린팅 기술은 3D 스캔이나 모델링을 통하여 적측가공 방식으로 제작하는 기공기술로서 금형 없이 직접 생산이 가능하고 빠른 시간 내에 제작이 가능하여 최근 다양한 산업분야에서 본격적으로 적용되고 있다. 3D 프린팅 기술은 의료분야에 있어, 영상의학 및 방사선 치료분야에서 다양하게 활용되고 있지만 핵의학 분야에서는 관련 연구가 미비한 실정이다. 그러므로 본 연구는 기존에 적용되고 있는 핵의학분야 팬텀과 3D 프린팅 기술로 제작된 텀의 특성을 비교하고 적용 가능성을 평가하는데 목적을 두었다. Materials and Methods 방사선 투과도 변화측정 국제기준 팬텀인 알루미늄(Aluminum) 계단 쐐기(step wedge)를 기준($140mm{\times}62mm{\times}35mm$)으로 PMMA(Poly Methyl Meta Acrylate)와 ABS(Acrylonitrile Butadiene Styrene)재질로 각각 동일한 크기의 팬텀을 제작하였다. PMMA 팬텀은 핵의학 분야에서 주로 적용되는 팬텀의 성분과 동일한 소재로 제작하였고, ABS 팬텀 제작은 3D 프린팅 기술의 액체 기반형의 SLA(Stereo Lithography Apparatus)기법을 사용하여 제작하였다. 본 연구는 SPECT/CT장비 BrightView XCT(Philips Health Care, Cleveland, USA)를 이용하였다. 영상 획득은 Rectangular Flood phantom(Biodex, New York, USA) $^{99m}TcO_4$ 3, 6 mCi와 $^{57}Co$ lood phantom(adqual, New Hampshire, USA) $^{57}Co$ 20 mCi를 이용하여 Aluminum, PMMA, ABS 팬텀에 대해 60 min 리스트모드(List mode)로 획득하였다. 획득한 영상의 분석을 위해 관심영역(ROI)을 설정하여 각 팬텀의 단계별로 평가하였다. Results 방사선원의 종류 및 방사선량에 따라 ABS 팬텀의 계수치는 PMMA 팬텀의 계수치와 유사한 값을 나타내며, 두께의 증가에 따라 선형적으로 감소하였다. Aluminum, PMMA, ABS 팬텀의 선감약계수를 비교했을 때, Aluminum 팬텀의 선감약계수는 나머지 두 팬텀보다 수치가 높았고, PMMA, ABS 팬텀에서는 근사치의 선감약계수가 나타났다. Conclusion 3D 프린팅 기술로 제작된 ABS 팬텀을 기준으로 PMMA 팬텀은 두께가 증가함에 따른 계수치의 변화가 유사하게 선형적으로 감소하였고, 선감약계수도 근사치로 나타내었다. ABS 팬텀의 핵의학적 적용 가능성을 확인할 수 있었으며, 추후 연구를 통해 세부적인 교정치(correction value)를 적용한다면 활발한 적용이 가능하리라 사료된다.

  • PDF