• 제목/요약/키워드: 3-phase Transformer

검색결과 310건 처리시간 0.027초

저전압 3상 다이오드 정류회로의 특성 실험 (Characteristic Experimental of Low Voltage Three phase Diode Rectifier Circuit)

  • 서기영;김영문;문상필;김주용;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.89-92
    • /
    • 2001
  • In conventional three-phase rectifiers, it was necessary to use a transformer to obtain low output voltage. In this paper, we propose a characteristic experimental of three-phase diode rectifiers circuit that achieves low voltage by using a very simple circuit configuration that does not have a transformer and does not need any complex control. We also describe the operation principle of the proposed circuit, and der?ive a theoretical formula for its current waveform. On the basis these theoretical values with experimentally obtained input output current characteristics, current amplification factor, and output voltage characteristics, allowed us to confirm the soundness of our theoretical analyses.

  • PDF

새로운 위상변성 방법 (A New Method of Phase Transformation)

  • 오상세
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.38-41
    • /
    • 1964
  • This thesis is aimed to obtain efficiently economically any desired phases and single phase transformer without unbalance by using only a new transformer, applying the theory of rotating magnetic field. The brief construction and principle is as floow: two pieces of similar ring cores, triangular cores or polygonal cores are located on the upper and lower sides with equidistance. And the some number of similar leg cores, shaped a square-pillar or a sylinder, are arranged at equidistant of the core section. Ring windings or polyphase windings of AC machines are adopted as a winding method on the upper and lower cores. Three phase AC is applied to the primary windings on these cores so that the rotating magnetic field is induced on the cores and this magnetic fluxes pass through each of the secondary windings on the leg-cores with some difference in time.

  • PDF

자석-부하 전원장치를 위한 위상제어 정류기와 PWM 컨버터를 사용한 복합구조 시스템의 전력회로 개선 (A Power Circuit Improvement of the Hybrid System Using Phase Controlled Rectifier and PWM Converter for Magnet Load Power Supply)

  • 강민구;손진근;전희종
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.231-235
    • /
    • 2008
  • Thyristor rectifiers are still the preferred choice for large magnet power supplies. However, large harmonic voltages, resulting in large current ripple, and slow dynamic response are major drawbacks of these converters. Joos presented a topology and a control technique for a hybrid large-power high-precision magnet power supply in 1996. The system consists of a phase controlled rectifier (PCR) connected in series with a high-frequency PWM converter. This paper improves the power circuit of the PWM converter using interphase transformer. Simulation result proves effect of the proposed system.

넓은 입력 전압 범위를 갖는 20kW급 양방향 3상 푸쉬풀 컨버터 (A 22kW Bidirectional Three-Phase Push-Pull Converter for Wide Voltage Range Application)

  • 레덧탕;정현주;김선주;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.8-10
    • /
    • 2019
  • In this paper, a bidirectional three-phase push pull converter is analyzed for the high power, wide voltage range applications. From comparison analysis of two switching methods: PWM plus phase-shift (PPS) and dual-asymmetric PWM (DAPWM) with the effect of dead-time, the proposed hybrid control is aimed to reduce the circulating current under wide voltage range operation. Value of leakage inductance effect to the peak current value, current stress and conduction loss in facing the load variation. Trade-off between power range and slew rate of transformer current was analyzed for properly selecting value of the transformer leakage inductance. Experimental results from a 22-kW prototype are provided to validate the proposed concept.

  • PDF

3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석 (Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator)

  • 송웅협;박해영;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.71-72
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석 (Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator)

  • 송웅협;박해영;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.532-533
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

철도 부하의 동적 특성을 고려한 전류 불평형의 분석과 보상 (Analysis and compensation of the current unbalance considering dynamic characteristic of feeding traction loads)

  • 김기표;김진오
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.54-60
    • /
    • 2003
  • 3상 전력계통에 단상 대용량의 전철부하가 접속되면 3상 전류가 불평형하게 되어 역상 전류가 흐르게 된다. 이 역상전류는 전원 측 발전기의 회전자 표면에 과전류를 발생시키며, 급전계통 및 관련 설비에 나쁜 영향을 끼치게 된다. 현재 교류 전기철도에서는 불평형 경감을 위하여 Scott결선 변압기를 채용하고 있으나 2차 극의 서로 다른 단상부하 크기 및 위상을 동일하게 일치시킬 수는 없고, 회생부하 전기차 도입과 인관 변전소 사고로 인한 연장급진도 고려해야 되기 때문에 역상전류 보상기가 필요하다. 본 논문은 기존의 전류불평형 해석방법인 정적모델 평가기법 대신에 열차운행스케줄에 따른 동적 특성을 이용한 새로운 전류불평형 평가기법을 유도하였으며, 이를 통해 부하 측의 불평형에 의해 발생하는 역상전류를 흡수하기 위한 보상기를 제안하고 실 계통에 가까운 전류불평형 문제를 분석하였다.

적층 압전변압기용 저온소결 PMN-PZT 압전세라믹의 소성시간에 따른 미세구조 및 압전특성 (Microstructural and piezoelectric properties of low temperature sintering PMN-PZT ceramics for multilayer piezoelectric transformer with the variations of sintering times)

  • 이창배;류주현;이상호;백동수;정영호;윤현상;임인호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.425-430
    • /
    • 2004
  • In this paper, in order to develop the low temperature sintering ceramics for multilayer piezoelectric transformer, PMN-PZT ceramics were manufactured with the variations of sintering times, and their microstructural, piezoelectric and dielectric properties were investigated. To manufacture multilayer piezoelectric transformer, the low temperature sintering composition is need, hence, $Li_2CO_3$ and $Bi_2O_3$ were used as sintering aids and the specimens were sintered during 30, 60, 90, 120, 150 and 180 minutes, respectively. At the specimen sintered during 90 minute, mechanical quality factor(Qm), electromechanical coupling factor(kp) and dielectric constant were showed the optimum values of 2356, 0.504 and 1266, respectively. All the specimens showed tetragonality phase, and pyrochlore phase was not shown.

  • PDF

순환전류 감소를 위한 새로운 정류회로를 갖는 위상천이 풀브리지 컨버터 (A Phase-Shifted Full-Bridge Converter With a New Rectifier Circuit for Reducing Circuiting Current)

  • 최병기;이우석;이일운
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.237-240
    • /
    • 2021
  • This research proposes a new rectifier circuit to reduce the circulating current of a phase-shifted full bridge converter. The proposed circuit is a structure in which the output inductor of the secondary rectifier circuit is changed to a coupled inductor in the phase-shifted full bridge with the existing center-tapped rectifier. The parts are rearranged after adding a diode. After applying the proposed circuit, the circulating current to the primary current of the transformer and the voltage stress of the rectifier diode on the secondary side of the transformer are reduced. Accordingly, the snubber loss of the rectifier is improved. By reducing the circulating current and snubber loss, the circuit achieves higher efficiency than conventional circuits. In this research, we present the structure of the proposed circuit, its strengths, and the analysis results from experiments. Furthermore, its effectiveness is verified through the experimental results of a prototype converter with an input of 300-400 V and an output of 50 V/1 kW.

변압기 소음에 의한 변전소 소음예측 및 저소음 변압기 현장적용 (The Audible Noise Prediction of the Substation due to Transformer Audible Noise and the Field Application of the Low Noise Transformer)

  • 권동진;구교선;김경탁;우정욱
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1382-1387
    • /
    • 2010
  • Recently, there has been a growing interest in the environmental conservation. Accordingly, problems related to the audible noise of transformers have became more frequent. Therefore, it is urgent to find a fundamental solution about the audible noises in the substations. This paper described a sort of fundamental solution to solve the noise problem. As a fundamental solution, we suggested the proper audible noise level of transformers through noise prediction in the substation construction phase. And we applied the low noise transformers which have the predicted noise level. As the result, we are able to satisfy the noise regulation through measuring 43.6dBA at the boundary of substation. It is confirmed that the average error rate of prediction was within 3 percent.