• Title/Summary/Keyword: 3-mask

Search Result 1,005, Processing Time 0.041 seconds

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Cohort Observation of Blood Lead Concentration of Storage Battery Workers (축전지공장 근로자들의 혈중 연농도에 대한 코호트 관찰)

  • Kim, Chang-Yoon;Kim, Jung-Man;Han, Gu-Wung;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.324-337
    • /
    • 1990
  • To assess the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, 156 workers (116 exposed subjects and 40 controls) of a newly established battery factory were examined for their blood lead concentration (Pb-B) in every 3 months up to 18 months. Air lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean Pb-B of the controls was $21.97{\pm}3.36{\mu}g/dl$ at the preemployment examination and slightly increased to $22.75{\pm}3.38{\mu}g/dl$ after 6 months. Mean Pb-B of the workers who were employed before the factory was in operation (Group A) was $20.49{\pm}3.84{\mu}g/dl$ on employment and it was increased to $23.90{\pm}5.30{\mu}g/dl$ after 3 months (p<0.01). Pb-B was increased to $28.84{\pm}5.76{\mu}g/dl$ 6 months after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $26.83{\mu}g/dl\;and\;28.28{\mu}g/dl$ in the subsequent 4 tests. Mean Pb-B of the workers who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $16.58{\pm}4/53{\mu}g/dl$ before the exposure and it was increased to $28.82{\pm}5.66{\mu}g/dl$(P<0.01) in 3 months later (1 month after the intervention). The values of subsequent 4 tests remained between 26.46 and $28.54{\mu}g/dl$. Mean Pb-B of the workers who were employed after intervention program had been started (Group C) was $19.45{\pm}3.44{\mu}g/dl$ at the preemployment examination and gradually increased to $22.70{\pm}4.55{\mu}g/dl$ after 3 months(P<0.01), $23.68{\pm}4.18{\mu}g/dl$ after 6 months, and $24.42{\pm}3.60{\mu}g/dl$ after 9 months. Work stations were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3\;and\;0.208mg/m^3$ in follow-up tests. The Pb-A of part II was decreased from $0.232mg/m^3\;to\;0.148mg/m^3,\;and\;0.120mg/m^3$ after the intervention. Pb-A of part III and W was tested only after intervention and the Pb-A of part III were $0.124mg/m^3$ in Jannuary 1988 and $0.081mg/m^3$ in August 1988. The Pb-A of part IV not stationed at one place but moving around, was $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-B and Pb-A. Pb-B of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. Pb-B of the workers in the part of the lowest Pb-A incerased more rapidly. Pb-B of group C workers was the highest in part I and the lowest in part IV. These findings suggest that Pb-B is more valid method than Pb-A for monitoring the health of lead workers and intervention in personal hygiene is more effective than environmental intervention.

  • PDF

A cohort study on blood zinc protoporphyrin concentration of workers in storage battery factory (축전지 공장 근로자들의 혈중 Zinc Protoporphyrin에 대한 코호트 연구)

  • Jeon, Man-Joong;Lee, Joong-Jeong;SaKong, Joon;Kim, Chang-Yoon;Kim, Jung-Man;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.112-126
    • /
    • 1998
  • To investigate the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, the blood zinc protoporphyrin (ZPP) concentrations of 131 workers (100 exposed subjects and 31 controls) of a newly established battery factory were analyzed. They were measured in every 3 months up to 18 months. Ai. lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean blood ZPP concentration of the controls was $16.45{\pm}4.83{\mu}g/d\ell$ at the preemployment examination and slightly increased to $17.77{\pm}5.59{\mu}g/d\ell$ after 6 months. Mean blood ZPP concentration of the exposed subjects who were employed before the factory was in operation (Group A) was $17.36{\pm}5.20{\mu}g/d\ell$ on employment and it was increased to $23.00{\pm}13.06{\mu}g/d\ell$ after 3 months. The blood ZPP concentration was increased to $27.25{\pm}6.40{\mu}g/d\ell$ on 6 months (p<0.01) after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $25.48{\mu}g/d\ell$ and $26.61{\mu}g/d\ell$ in the subsequent 4 results. Mean blood ZPP concentration of the exposed subjects who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $14.34{\pm}6.10{\mu}g/d\ell$ on employment and it was increased to $28.97{\pm}7.14{\mu}g/d\ell$ (p<0.01) in 3 months later(1 month after the intervention). The values of subsequent 4 tests were maintained between $26.96{\mu}g/d\ell$and $27.96{\mu}g/d\ell$. Mean blood ZPP concentration of the exposed subjects who were employed after intervention program had been started (Group C) was$21.34{\pm}5.25{\mu}g/d\ell$ on employment and it was gradually increased to $23.37{\pm}3.86{\mu}g/d\ell$ (p<0.01) after 3 months, $23.93{\pm}3.64{\mu}g/d\ell$ after 6 months, $25.50{\pm}3.01{\mu}g/d\ell$ after 9 months, and $25.50{\pm}3.10{\mu}g/d\ell$ after 12 months. Workplaces were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3$ and$0.208mg/m^3$ in follow-up test. The Pb-A of part II which was resulted in lowe. value than part I was decreased from $0.232mg/m^3$ to $0.148mg/m^3$, and $0.120mg/m^3$ after the intervention. The Pb-A of part III was tested after the intervention and resulted in $0.124mg/m^3$ in January 1988 and $0.181mg/m^3$ in August 1988. The Pb-A of part IV was also tested after the intervention and resulted in $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-A and blood ZPP concentration. The blood ZPP concentration of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. The blood ZPP concentration of the workers in the part of the lowest Pb-A increased more rapidly. The blood ZPP concentration of the group C workers was the highest in part III. These findings suggest that the intervention in personal hygiene is more effective than environmental intervention, and it should be carried out from the first day of employment and to both the exposed subjects, blue color workers and the controls, white color workers.

  • PDF

Compliance Level of Universal Precautions to Hospital Infection and related factors of Health Care Workers in a University Hospital (대학병원 의료종사자들의 병원감염에 대한 예방지침 실행수준과 관련요인)

  • Yu, Mi Jong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.143-154
    • /
    • 1998
  • The purpose of this research is to suggest basic materials for the practical infection precaution program to protect health care workers from hospital infection by grasping their compliance level of Universal Precautions and examining the factors affecting them. The number of the health care workers we studied were 486, including the doctors, the nurses, and the lab technicians who were working in a university hospital. The period of this research was from Aug. 18th, 1997 to Aug. 30th, 1997. The method of the study was to measure the compliance level of Universal Precautions with the item of "Universal Precautions" established by CDC in 1987, and examine the questionnaire of 52 questions dividing related factors into socio-populational, individual, socio-psychological and organizational management ones. The data was analyzed by t-test. ANOVA, and chi-square test. The results were as follows : 1. An the compliance level of Universal Precautions, hand washing had the highest score(85.4%), and doctors(18.9%), nurses(44.0%), and lab technicians(7.6%), had a low compliance level in the safe handling of an injection syringe, and item not to handle patients and their samples when the subject suffered from dermatitis or injury had the lowest score of 17.1%. 23.3% of them said that they wear protection gown, goggles and mask. 2. Female's Compliance level of Universal Precautions Was higher than male. 3. The health care workers who had high recognition on Universal Precautions got significantly higher compliance level of Universal Precautions than those have low recognition on Universal Precautions(P<0.001). 4. The health care workers experienced a needle stick injury had a significantly higher compliance level of Universal Precautions than those who had not(P<0.000). 5. The health care workers who had infection protection education got a significantly higher compliance level of Universal Precautions than those who didn't(P<0.000). 6. The health care workers who had a firm belief in the effect of Universal Precautions got a higher compliance level of Universal Precautions than those who didn't. 7. The health care workers who had less conflicts between treating patient arid protecting them-selves got a higher compliance level of Universal Precautions than others with many conflicts. 8. The health care workers who had a high score in organizational management factors got a significantly higher compliance level of Universal Precautions than those with a low score(P<0.000). 9. Only 16.9 percent of the all respondents(82 in number) answered that they knew well or a little about the Universal Precautions, which is very low rate of recognition. 10. The variables which affected the score in organizational management factors were age, sex, education period, work experience, the kind of work, recognition on Universal Precautions, the experience of needle stick injury, revealing dangerous circumstance related to infection, and training on precaution again infection. According to the result above, compliance level of Universal Precautions showed high correlation with sex, the recognition on Universal Precautions, the experience of needle stick injury, training on precaution against infection, the belief in the effect of Universal Precautions, the recognition degree of conflicts and organizatinal management factors. These results could be used as the basic materials for the developing infection protection programs. Also, There should have a systematic training course to elevate a effective compliance level of Universal Precautions as well as the manageeent of infection protection programs.

  • PDF

A Study on the Demand for Equipent Development in Nursing (간호기기 개발수요 조사연구)

  • Chang, Soon-Book;Kim, Eui-Sook;Whang, Ae-Ran;Kang, Kyu-Sook;Suh, Mi-Hae
    • The Korean Nurse
    • /
    • v.35 no.2
    • /
    • pp.71-91
    • /
    • 1996
  • The objectives of thes study were to identify the need for equipment development in nursing, and to determine the priorities for that development. The study was descriptive study done between March 2 and May 30, 1995, in which the subjects, including 421 patients, 223 family members, and 198 nurses from neurosurgery, orthopedic, rehabilitation medicine, internal medicine and intensive care units of nine general hospitals in Seoul, completed a questionnarie developed by the research team. The questionnaire consisted of 35 open and closed questions. Data was analyzed using frequencies and percentages. The results ware summarized as follows: 1) The average age of the nurses was 27.9 years, 48% of the patients were between 20 and 40 years of age, and 17% were over 60. The average lingth of experience for the nurse subjects was four years five months with 36.9%. having over five years experience. The most frequent diagnoses of patients were spinal disc(35.9%), internal medicine disease(26.0%), cerebral vascular accident(16.6%) and spinal cord injury(10%) 2) Many of the nurses(96.4%) reported deficiencies with existing equipment and 96.5% of the nurses, but only 79.8% of the patients, nurses' time. Further, 82.3% of the nurses and 75.8% of the patients felt that the development of new equipment would lead to a decrease in the cost of nursing care. 3) Nurses felt that the greatest areas of inconvenience were patient feeding(71.7%), hygiene(71.2%), caring for a patient confined to bed(70.7%), patient clothing(67.2%), mobility transfers(63.5%) and urinary elimination(52.0%). However, patients and family members listed the following as being the most inconvenient: urinary elimination(58.7%), Hygiene(50.5), feeding(48.4%), mobility transfers(47.1%) and bed care(45.2%). 4) Generally the nurses listed more inconveniences and patients and family members listed more demands for the development of equipment. These included utensils with large handles, and regulators for tube feedings; mattresses that provide for automatic position change and massage, which have patient controlled levers and a place for bed pan insertion; automatic lifts or transfer from bed to wheelchair; equipment to facilitate washing and oral hygiene as well as equipment that will allow patients with spinal cord injuries easy access to showers; a bed pan/urinal for women that is comfortable and effective from which urine can be measured and disposed of easily; disposable dressing sets and tracheostomy care sets and a convenient way of measuring changes in wound size; a safe delivery system for oxygen, a variety of mask sizes and better control of humidity, tracheal material than at present, as well as a communication system for patients with tracheostomies; clothing that will allow access to various parts of the body for treament or assessment without patients having to remove all of their clothing; and finally a system that will allow the patient to control lighting, telephones and pagers. Priority areas for equipment development reported by the nurses were, urinary elimination(58. 7%), hygiene(50.5%), feeding(48.4%), mobility transfers(47..1%), bowel elimination(40.8%). Those reported by the patients family members were feeding(71.7%), hygiene(70.0%), bedcare(70.7%), clothing(67.2%), mobility transfers(63.6%), urinary elimination(52.9%) and bowel elimination(50.5%) Altogether, nurses, patients and family members listed the following as priorities; clothing (178), bed care(144), urinary elimination(92), environment(81), hygiene(70). Further, a health professional forum listed urinary elimination, oxygen delivery, medication delivery, mobility transfers, bed care and hygiene in that order as priority areas. From this study it can be concluded that the first need is to develop equipment that will address the problems of urinary elimination. To do (l)This nurses who are interested in equipment development should organize an equipment development team to provide a forum for discussion and production of equipment for nursing.

  • PDF

A Survey on the Workplace Environment and Personal Protective Equipment of Poultry Farmers (양계 농업인의 작업장 환경 및 개인보호구 착용 실태조사)

  • Kim, Insoo;Kim, Kyung-Ran;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Sungwoo
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.454-468
    • /
    • 2014
  • Objectives: This study was conducted to investigate the actual condition of the farm work environment and personal protective equipment as part of the effort to improve livestock work for the safety and health of poultry farmers and provide basic data for establishing plans to improve and develop personal protective equipment. Methods: For this purpose, a questionnaire survey on general information about stables, the poultry work environment, accidents, the wearing of work clothes and personal protective equipment, and the level of awareness related to personal protective equipment was conducted among 148 poultry farmers. Results: As a result, it was found that poultry workplace environment was exposed to such risks as fine dusts; organic dusts; poisonous gases; odorous substances; chicken excrement; contact with chickens, bacteria or viruses; and accidents related to machine operation. Thirteen percent of respondents suffered severe respiratory diseases, and the most frequently injured sites due to accidents were the hands (25.7%), knees (23.8%), arms (17.3%), and head (10.9%). The most frequent type of accident was collisions between the body and obstacles or machinery during movement (36.4%), followed by erroneous machine operation such as feeders and electric shocks (8.5%). Regarding the wearing of work clothes and personal protective equipment, 51.7% of the respondents wore worn-out clothing or everyday clothes, whereas only 32.0% wore work clothes. The percentage of farmers who wore proper protective equipment for the work environment during poultry work was 48.4%. The most frequently used type of protective equipment was boots (38.9%), followed by mask (36.7%), gloves (36.3%), appropriate work clothes (22.6%), quarantine clothes (17.6%), helmets (13.4%), and goggles (12.6%). The rate of wearing goggles was low because they were considered inconvenient and lowered work efficiency. Furthermore, they purchased everyday products available on the market for their personal protective equipment which were not appropriate for maintaining safety in an actual harmful environment and its consequent risks. As a result of the survey of the awareness level related to personal protective equipment, their levels of awareness of accidents and attitude proved to be average or higher, but the practice of wearing protective equipment and the level of knowledge and management of personal protective equipment were lower. Conclusion: This survey found that the wearing status of personal protective equipment among poultry farmers was insufficient even though they were exposed to risks. Most respondents were aware of the necessity of wearing personal protective equipment and of the potential for accidents, but they did not wear proper protective equipment. Their wearing rate was low due to a lack of knowledge about protective equipment, as well as the inconvenience of wearing it. Therefore there is a need to improve and develop specialized personal protective equipment for respiration, hands, and eyes, as well as work clothes that can protect farmers from major harmful matter that is generated in the poultry workplace. Based on the results of this investigation, we will conduct further studies on the required performance and design directions of personal protective equipment while collecting more objective data through field-oriented assessments.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Effect of Intravenous Administration of Tramadol on the Minimum Alveolar Concentration of Isoflurane in Dogs (개에서 트라마돌의 정맥투여가 아이소플루란의 최소폐포농도에 미치는 영향)

  • Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Jin, So-Young;Kim, Young-Ki;Hwang, Jae-Min;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.308-312
    • /
    • 2015
  • This study was aimed to evaluate the effects of tramadol hydrochloride on the minimum alveolar concentration of isoflurane ($MAC_{ISO}$) in dogs. Six healthy, female German shepherd dogs (aged 1-2 years) were used in this study. Anesthesia was induced by mask induction and maintained with isoflurane in oxygen. Mechanical ventilation maintained the end-tidal $CO_2$ partial pressure ($P_{ET}CO_2$) from 35 to 45 mmHg throughout the study. A baseline $MAC_{ISO}$ ($MAC_{ISO}B$) was determined starting 45 minutes after induction of anesthesia by clamping a pedal digit until gross purposeful movement was detected. After $MAC_{ISO}B$ determination, dogs received a tramadol loading dose of 3 mg/kg followed by a continuous rate infusion (CRI) of 2.6 mg/kg/h. The determination of $MAC_{ISO}$ after administration of tramadol ($MAC_{ISO}T$) began 20 min after the start of the CRI. Arterial blood pressure and heart rate were recorded continuously and arterial blood samples for blood gas analysis were collected at the end of the equilibration period. Mean ${\pm}$ SD values for the $MAC_{ISO}B$ and $MAC_{ISO}T$ were $1.33{\pm}0.04%$ and $1.23{\pm}0.04%$, respectively. The $MAC_{ISO}B$ decreased significantly by $7.5{\pm}0.2%$ (P < 0.05) after administration of tramadol. The mean heart rate and arterial blood pressure of six dogs were not changed significantly after tramadol administration. The blood gas levels remained constant during the study. In conclusion, tramadol could significantly reduce $MAC_{ISO}$ without depression of cardiorespiratory function. Thus, the use of tramadol on inhalation anesthesia with isoflurane in dogs can improve the stability of anesthesia and the quality of recovery.

Effect of Rosemary and Clove Essential Oils on Quality and Flavor Compounds of Fried Korean Native Chicken Thigh Meat (로즈마리와 클로브 에센셜 오일의 항산화 특성과 토종닭 후라이드 치킨의 품질특성 및 풍미성분에 미치는 영향)

  • Soomin Oh;Yousung Jung;Sangrok Lee;Hee-Jeong Lee;Dongwook Kim;Hyo-Jun Choo;Dong-Jin Shin;Aera Jang
    • Korean Journal of Poultry Science
    • /
    • v.50 no.3
    • /
    • pp.143-159
    • /
    • 2023
  • The study aimed to evaluate the antioxidative effects of rosemary (Rosmarinus officinalis L.) and clove (Syzgyium aromaticum L.) essential oils on fried Korean native thigh meat, including their impact on processed characteristics and flavor compounds. Clove essential oil showed higher DPPH scavenging activity, FRAP and total phenol content compared to rosemary essential oil (P<0.05). The treatments with the addition of 0.005% and 0.01% rosemary (0.005RB and 0.01RB) and clove (0.005CB and 0.01CB) essential oils to the batter weight compared to control that did not include essential oils in batter. The addition of rosemary and clove essential oils to fried Korean native chicken thigh meat did not significant affect proximate composition, pH, TBARS, sensory characteristics. Except for 0.005CB, treatments adding essential oils decreased cooking loss (P<0.05) and 0.005CB showed significantly higher pick-up value than control. Addition of clove essential oil in fried Korean native chicken thigh meat resulted in higher levels of arachidonic acid compared to control (P<0.05). Volatile organic compounds (VOCs) analysis showed that addition of rosemary essential oil might mask its own VOCs, while clove essential oil addition reduced some pyrazine compounds. Although addition of rosemary and clove essential oil did not have significant sensory characteristics on fried Korean native chicken thigh meat, instrumental analysis revealed changes in the compounds that influenced flavor. Further studies are required to evaluate the stability of flavor and sensory characteristics of fried Korean native chicken thigh meat with added essential oils during storage.

Use of Noninvasive Mechanical Ventilation in Acute Hypercapnic versus Hypoxic Respiratory Failure (급성 환기부전과 산소화부전에서 비침습적 환기법의 비교)

  • Lee, Sung Soon;Lim, Chae-Man;Kim, Baek-Nam;Koh, Younsuck;Park, Pyung Hwan;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.987-996
    • /
    • 1996
  • Background : We prospectively evaluated the applicability and effect of noninvasive ventilation (NIV) in acute respiratory failure and tried to find out the parameters that could predict successful application of NIV. Methods : Twenty-six out of 106 patients with either acute ventilatory failure (VF: $PaCO_2$ > 43 mm Hg with pH < 7.35) or oxygenation failure (OF: $PaO_2/AO_2$ < 300 mm Hg with $pH{\geq}7.35$) requiring mechanical ventilation were managed by NIV (CPAP + pressure suppon, or BiPAP) with face mask. Eleven out of 19 cases with VF (57.9%) (M : F=7 : $55.4{\pm}14.6$ yrs) and 15 out of 87 cases with OF (17.2%) (M : F=12 : 3, $50.6{\pm}15.6$ yrs) were s uilable for NIY. Respiratory rates, arterial blood gases and success rate of NIV were analyzed in each group. Results: 81.8% (9/11) of YF and 40% (6/15) of OF were successfully managed on NIV and were weruled from mechanical ventilator without resorting to endotracheal intubation. Complications were noted in 2 cases (nasal skin necrosis 1, gaseous gastric distension 1). In NIV for ventilatory failure, the respiration rate was significantly decreased at 12 hour of NIV ($34{\pm}9$ /min pre-NIV, $26{\pm}6$ /min at 12 hour of NIV, p=0.045), while $PaCO_2$ ($87.3{\pm}20.6$ mm Hg pre-NIV, $81.2{\pm}9.1$ mm Hg at 24 hour of NIV) and pH ($7.26{\pm}0.04$, $7.32{\pm}0.02$, respectively, p <0.05) were both significantly decreased at 24 hour of NIV In NIV for oxygenation failure, $PaCO_2$ were not different between the successful and the failed cases at pre-NIV and till 12 hours after NIV. The $PaO_2/FIO_2$ ratio, however, significantly improved at 0.5 hour of NIV in successful cases and were maintained at around 200 mm Hg (n=6 : at baseline, 0.5h, 6h, 12h : $120.0{\pm}19.6$, $218.9{\pm}98.3$, $191.3{\pm}55.2$, $232.8{\pm}17.6$ mm Hg, respectively, p=0.0211), but it did not rise in the failed cases (n=9 : $127.9{\pm}63.0$, $116.8{\pm}24.4$, $100.6{\pm}34.6$, $129.8{\pm}50.3$ mm Hg, respectively, p=0.5319). Conclusion : From the above results we conclude that NIV is effective for hypercapnic respiratory failure and its success was heralded by reduction of respiration rale before the reduction in $PaCO_2$ level. In hypoxic respiratory failure, NIV is much less effective, and the immediate improvement of $PaO_2/FIO_2$ ratio at 0.5h after application is thought to be a predictor of successful NIV.

  • PDF