• 제목/요약/키워드: 3-Dimensional model test

검색결과 519건 처리시간 0.028초

Prediction of ions migration behavior in mortar under 2-D ALMT application to inhibit ASR

  • Liu, Chih-Chien;Kuo, Wen-Ten
    • Computers and Concrete
    • /
    • 제14권3호
    • /
    • pp.263-277
    • /
    • 2014
  • This study investigated four electric field configurations of two-dimensional accelerate lithium migration technique (ALMT), including line-to-line, plane-to-line, contour-to-line and plane-to-plane, and analyzed the ion migration behavior and efficiency. It was found that the free ion distribution diagram and voltage distribution diagram were similar, and ions migrated in the power line direction. The electrode modules were used for the mortar specimen with w/c ratio of 0.5. The effectively processed areas accounted for 14.1%, 39.0%, 49.4% and 51.4% of total area respectively on Day 28. Larger electrode area was more advantageous to ion migration. In addition, it was proved that the two-dimensional electric field could be divided into different equifield line active regions, and regarded as affected by one-dimensional electric field, and the ion migration results in various equifield line active regions were predicted by using the duration analysis method based on the theoretical model of ion migration obtained from one-dimensional test.

광중합형 프린터로 제작한 인공치아, 의치상, 모노블럭 총의치의 후경화에 따른 3차원 정확성 평가 (Three-dimensional accuracy evaluation of post-curing of artificial teeth, denture bases, and denture base monoblocks manufactured by digital light processing)

  • 김동연;양천승;이광영
    • 대한치과기공학회지
    • /
    • 제46권3호
    • /
    • pp.84-92
    • /
    • 2024
  • Purpose: To evaluate the effect of post-curing on the three-dimensional (3D) accuracy of artificial teeth, denture bases, and denture base monoblock manufactured using digital light processing (DLP) technology. Methods: Using an edentulous model, a 3D design was made for complete dentures. Three groups were printed by DLP: artificial teeth, denture bases, and denture base monoblock. The models were scanned, subjected to post-curing, and scanned again. Three-dimensional analysis was performed based on the post-treatment differences among the three groups. Statistical analysis was performed using SPSS Statistics ver. 22.0 (IBM), and the Mann-Whitney U-test and Kruskal-Wallis test were employed as nonparametric tests. Results: The complete denture monoblock (CM) and complete denture artificial teeth (CA) groups showed the lowest and highest errors at 15.13 and 23.37 ㎛, respectively. The groups did not show significant differences (p>0.05). In the significance test among the three groups, no significance was found in the CA group; however, significant differences were found between the complete denture base (CB) and CM groups. In addition, the three groups showed significant differences (p<0.05). Conclusion: Although deformation may occur during the post-curing process, it is within the clinically acceptable range. Future comparative studies using different 3D printers and searching for ways to minimize errors through optimization of the post-curing process are warranted.

MSBS-SPR Integrated System Allowing Wider Controllable Range for Effective Wind Tunnel Test

  • Sung, Yeol-Hun;Lee, Dong-Kyu;Han, Jong-Seob;Kim, Ho-Young;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.414-424
    • /
    • 2017
  • This paper introduces an experimental device which can measure accurate aerodynamic forces without support interference in wide experimental region for wind tunnel test of micro aerial vehicles (MAVs). A stereo pattern recognition (SPR) method was introduced to a magnetic suspension and balance system (MSBS), which can eliminate support interference by levitating the experimental model, to establish wider experimental region; thereby MSBS-SPR integrated system was developed. The SPR method is non-contact, highly accurate three-dimensional position measurement method providing wide measurement range. To evaluate the system performance, a series of performance evaluations including SPR system measurement accuracy and 6 degrees of freedom (DOFs) position/attitude control of the MAV model were conducted. This newly developed system could control the MAV model rapidly and accurately within almost 60mm for translational DOFs and 40deg for rotational DOFs inside of $300{\times}300mm$ test section. In addition, a static wind tunnel test was conducted to verify the aerodynamic force measurement capability. It turned out that this system could accurately measure the aerodynamic forces in low Reynolds number, even for the weak forces which were hard to measure using typical balance system, without making any mechanical contact with the MAV model.

진화 알고리즘기반의 SI기법을 이용한 외부 프리스트레싱으로 보강된 텐던의 장력 추정 (Estimation of External Prestressing Tendon Tension Using Sl Technique Based on Evolutionary Algorithm)

  • 장한택;노명현;이상열;박대효
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.156-159
    • /
    • 2008
  • This paper introduces a remained tensile force estimation method using SI technique based on evolutionary algorithm for externally prestressed tendon. This paper applies the differential evolutionary scheme to SI technique. A virtual model test using ABAQUS 3 dimensional frame model has been made for this work The virtual model is added to the tensile force(28.5kN). Two set of frequencies are extracted respectively from the virtual test and the self-coding FEM 2 dimension model. The estimating tendon tension for the FEM model is 28.31kN. It is that the error in the tendon tension is 1% through the differential evolutionary algorithm. The errors between virtual model and the self-coding FEM model are assumed as the model error.

  • PDF

치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구 (The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials)

  • 최석순;김기백;이경탁;전진훈;김재홍
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

UTM투영에 의한 Bessel과 WGS84 타원체간의 2차원 측지좌표변환 연구 (A Study on the Transformation of Two Dimensional Geodetic Coordinates between Bessel and WGS84 Ellipsoids by UTM Projection)

  • 이용창;강준묵
    • 한국측량학회지
    • /
    • 제16권2호
    • /
    • pp.149-158
    • /
    • 1998
  • 본 연구에서는 GPS에 의한 2차원 실용좌표의 획득면에 중점을 두고 WGS84와 벳셀타원체간의 3차원 좌표변환에 필수요소인 지역지오이드고 모델없이 두 타원체간 투영좌표의 상호 변환모델식을 구성하여 점검점에 적용하고 실용성과와 비교 고찰하므로서 UTM투영좌표에 의한 타원체간 2차원 좌표변환의 산정법을 제시한 것이다. 인천시지역을 시험모델로 관내 11개 삼각점으로부터 상호변환계수를 도출하고 점검점인 15개 지적삼각점에 적용하여 양방향의 변환정밀도를 분석한 결과, 측지좌표의 경우 위도 및 경도성분에서 각각 $\pm0.006$초, $\pm0.013$초, 평면직교좌 표의 경우는 남북 및 동서방향에서 각각 $\pm{17cm}$$\pm{30.0cm}$의 표준편차로 변환할 수 있었다. 또한, 남한지역을 대상으로 한 광역망, 경인.충남지역의 지역망 및 인천지역의 국소망으로부터 3-매개변환, 7-매개변환 및 UTM좌표간 변환계수를 각각 산출하여 점검점에 적용하고 변환넓이에 따른 변환기법별 변환특성도 고찰하였다.

  • PDF

원전 주제어실 3차원 층 지진격리시스템의 진동대 실험 연구 (Shaking Table Experimental Study on 3-Dimensional Floor Isolation in Main Control Room of Nuclear Power Plant)

  • 이경진;함경원;서용표;윤현도
    • 한국지진공학회논문집
    • /
    • 제12권1호
    • /
    • pp.57-66
    • /
    • 2008
  • 본 연구에서는 원전 주제어실의 3차원 층 지진격리시스템에 대한 지진동 저감성능과 적용성을 평가하기 위해서 실험연구를 수행하였다. 3차원 층 지진격리시스템에 적용하기 위해서 마찰진자시스템과 에어 스프링을 설계하고 제작하였다. 제어 캐비닛과 액세스 플로어, 격자 프레임, 4개의 마찰진자와 에어 스프링으로 구성된 원전 주제어실 부분 실험모형을 2종류 제작하여 층 지진격리시스템의 원전 적용성을 평가하였다. 실험을 위해서 원전 주제어실의 운전기준지진(OBE)과 안전정지지진(SSE)의 수직방향, 수평방향 층 응답 스펙트럼을 이용하여 인공지진 시간이력을 만들어서 진동대 실험에 사용하였다. 입력지진에 대한 실험모형의 지진응답은 비 지진격리에 비해 3차원 층 지진격리시스템을 적용한 경우, 우수한 지진동 저감특성을 나타냈다

주기적 하중을 받는 탄소감축을 위한 조립 해체가 용이한 급속 시공 접합부(TZcon)의 수치해석 연구 (Finite Element Analysis of a Full-scale, Rapid-Disassembly, Carbon-Minimized Dismantle Connection Subjected to Cyclic Loading)

  • 오사벨 데이브;최형진;김상훈;김영주;배재훈
    • 한국전산구조공학회논문집
    • /
    • 제37권4호
    • /
    • pp.275-282
    • /
    • 2024
  • 최근 제안된 탄소감축을 위한 조립 해체가 용이한 접합부는 주기적 하중을 가력하여 시험하였다. 시험체의 거동을 더 잘 이해하기 위해 "Tied Model"(볼트 접촉 면이 묶여 있음)과 "Bolt-slip Model"(접촉 면이 미끄러지고 분리됨)을 사용하여 3차원 유한요소(3D-FE) 해석을 수행하였다. Tied Model은 제안된 접합부가 강 접합(Rigid Joint)으로 거동할 경우 보의 소성 힌지가 발생하는 것을 시사한다. 반면, Bolt-slip Model은 제안된 접합부가 적절히 제조(간극 없이) 및 조립된 경우 강성 접합부의 약 0.5배의 에너지를 소산할 수 있음을 시사한다. 그러나 시험 결과와 비교했을 때, 모멘트-회전 이력 곡선이 잘 맞지 않는 것으로 나타났으며, 이는 시험체의 제조 결함(약 5-10mm 간극)으로 인해 성능이 저하되었음을 시사한다. 그럼에도 불구하고 실험에서 관찰된 이력곡선의 핀칭 현상과 시험체의 파괴 모드는 서로 일치하였다.

6 단 압연기의 극박 압연공정에서 3 차원 판 형상 예측 (Prediction of Three-Dimensional Strip Profile for 6-High Mill in Thin-Strip Rolling)

  • 이상호;송길호;이성진;김병민
    • 대한기계학회논문집A
    • /
    • 제35권8호
    • /
    • pp.855-861
    • /
    • 2011
  • 본 연구에서는 극박 압연 이론과 6 단 압연기 수식 모델을 이용하여 압연 후 판 형상 예측에 대하여 제안하였다. 폭 방향에서 롤 사이의 접촉 압력과 판과 워크롤 사이의 압연하중은 6 단 압연기의 형상학적 구조와 경계조건을 이용한 수식모델을 통하여 계산된다. 그리고 압연 방향의 압연하중 분포는 Fleck 의 극박 압연 이론을 이용하여 계산하였다. 워크롤의 3 차원 탄성 변형량은 폭 과 압연방향의 압력분포에 의하여 계산된다. 이때, 3 차원 판 형상은 워크롤의 탄성변형에 의하여 얻어진다. 또한 3 차원 판 형상은 극박 압연 실험과 유한요소해석을 통하여 검증하였다.

치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가 (Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models)

  • 이경탁;김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권3호
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.