사각덕트내의 유체유동에 관한 수치계산과 실험의 비교 (The comparison between Numerical Computation and Experiment on Fluid Elow in Rectangular Duct)

  • 윤영환;배택희;박원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.71-74
    • /
    • 2002
  • Fluid flow in a rectangular duct system are measured by W laser doppler velocity meter, and also computed by commercial software of STAR-CD for comparison between then First, for a rectangular duct with 90 degree metered elbow, the fluid flow with Reynolds numbs's of 1,508 is predicted by assumption of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300-3,000, the computation by turbulent model is close to the experimental data. Moeover, the computation by turbulent model for Reynolds number of 11,751 also predicts the experimental data satisfactorily. Second, for a rectangular duct with two branch ducts, the ratios between flow rates in the two branches are invariant to Reynolds number according to both of numerical and experimental results.

  • PDF

대규모 발파를 통한 한반도 지각의 2차원적 횡파 속도구조 연구 (Two-dimensional shear-wave velocity structures of the Korea peninsula from large explosions)

  • 김기영;홍명호;이정모;문우일;박창업;정희옥
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.75-79
    • /
    • 2007
  • To investigate the shear-wave velocity structures of the Korean peninsula, exploded seismic signals were recorded for 120 s along a 294-km WNW-ESE line and 150 s along a 335-km NNW-SSE line in 2002 and 2004, respectively. First arrival times of shear wave were inverted to derive the velocity tomograms. Initial shear-wave 1-D models were built using the initial P-wave velocity models used by Kim et al. and $V_p/V_s$ ratios of the IASP91 model. The raypaths indicate existence of mid-crust interfaces at the depth of 2-3 km and 16 km. The deepest significant interface corresponding to the Moho discontinuity varies in depth from 32 km to 36 km. The refraction velocity along the interface varies from 4.4 km/s to 4.6 km/s. The velocity tomograms also indicate existence of a low-velocity zone at the depth of 7.8 km under the Okchon fold belt.

  • PDF

국내 중소하천에 설치된 아이스하버 어도 내부 흐름 특성 규명 (Investigation for flow characteristics of ice-harbor type fishway installed at mid-sized streams in Korea)

  • 백경오;민병조
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.33-42
    • /
    • 2022
  • 본 연구에서는 3차원 상용 수치모형 Flow-3D를 활용하여 상류 수위(유입유량) 변동, 격벽의 간격(pool의 길이) 변화, 잠공 유무 등에 따른 아이스 하버 어도 내 흐름 양상을 분석하였다. 수치모의 결과의 적합성을 입증하기 위해 경안천 대곡교 하류에 설치된 실제 어도에서 3차원 초음파 유속계를 사용하여 어도 출구부 단면 유속과 유량을 관측하였다. Flow-3D 모형에는 난류 모듈로 4가지를 선택할 수 있는데, 관측 자료로 검증 결과 RNG 모형이 아이스하버 어도 내 흐름 특성을 가장 잘 재현하였다. 하천의 유량 전량이 어도로만 유입되어 흐른다는 조건에서 수위 변화에 따른 어도 내 유속구조를 모의해 보았다. 그 결과 최저수위에서는 잠입류와 표면류가 혼재하여 발생하였는데, 최저수위에서 약 10 cm 이상만 수위가 상승하여도 모든 pool에서 잠입류가 사라지고 오직 표면류만 발생하였다. 예상과 달리 수위가 조금 상승해도 흐름이 꽤 단순하게 표면류 위주로 발생하였다. 격벽간 간격을 늘려주면 수위가 상승하더라도 잠입류와 표면류가 혼재되어 나타나는 현상이 지속되었다. 그리고 격벽 하단에 잠공이 있는 경우가 없는 경우에 비해 잠입류가 여러 pool에서 생성되는 경향을 보였다. 보다 적극적인 어도 사후 관리로 잠공 폐색을 막아 어도 내 다양한 흐름이 생성될 수 있도록 유도하는 것이 필요해 보인다.

Comparative study of turbulent flow around a bluff body by using two- and three-dimensional CFD

  • Ozdogan, Muhammet;Sungur, Bilal;Namli, Lutfu;Durmus, Aydin
    • Wind and Structures
    • /
    • 제25권6호
    • /
    • pp.537-549
    • /
    • 2017
  • In this study, the turbulent flow around a bluff body for different wind velocities was investigated numerically by using its two- and three-dimensional models. These models were tested to verify the validity of the simulation by being compared with experimental results which were taken from the literature. Variations of non-dimensional velocities in different positions according to the bluff body height were analysed and illustrated graphically. When the velocity distributions were examined, it was seen that the results of both two- and three-dimensional models agree with the experimental data. It was also seen that the velocities obtained from two-dimensional model matched up with the experimental data from the ground to the top of the bluff body. Particularly, compared to the front part of the bluff body, results of the upper and back part of the bluff body are better. Moreover, after comparing the results from calculations by using different models with experimental data, the effect of multidimensional models on the obtained results have been analysed for different inlet velocities. The calculation results from the two-dimensional (2D) model are in satisfactory agreement with the calculation results of the three-dimensional model (3D) for various flow situations when comparing with the experimental data from the literature even though the 3D model gives better solutions.

CFD를 이용한 C-GIS의 열해석 (Thermal Analysis using CFD of Cubicle type Gas Insulated Switchgear)

  • 안희섭;홍두영;이한신;김영근;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.882-884
    • /
    • 2003
  • In this paper, thermal analysis of Cubicle type Gas Insulated Switchgear(C-GIS) was investigated through experiments and numerical analysis. To predict 3-dimensional temperature and velocity distribution, the commercial package was used. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

The differences in the potential energy anomaly for analyzing mixing and stratification between 2D and 3D model

  • Minh, Nguyen Ngoc;Hwang, Jin Hwan
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.240-240
    • /
    • 2015
  • As Simpson et al. (1990) emphasized the importance of the straining process in the stratification and mixing in the estuarine circulation process, various researches have investigated on the relative contribution of each process to the overall potential energy anomaly dynamics. However, many numerical works have done only for two dimensional modeling along channel or the short distance cross sectional three dimensional simulations as Burchard et al. (2008) and the estuarine channel was not simulated so far. But, in the study on the physics of shallow coastal seas, spatial dimension in the three dimensional way affects significantly on results of a particular numerical model. Therefore, the comparison of two and three dimensional models is important to understand the real physics of mixing and stratification in an estuary. Also, as Geyer and MacCready (2013) pointed out that the lateral process seems to be important in determining the periodic stratifications, to study such process the three dimensional modeling must be required. The present study uses a numerical model to show the signification roles of each term of the time-dependent dynamic equation for the potential energy anomaly (PEA) in controlling along and lateral channel flows and different stratification structures. Moreover, we present the relationships between the ${\Phi}$-advection, the depth mean straining, vertical mixing and vertical advection can explain well how water level, salinity distribution and across velocity 2D model are slightly different from 3D.

  • PDF

River2D 모델을 이용한 섬진강의 생태유지유량 산정에 관한 연구 (Study on Ecological Instream Flow Estimation using River2D Model in the Seomjin River)

  • 노경범;박성천;진영훈;박명옥
    • 한국물환경학회지
    • /
    • 제27권6호
    • /
    • pp.822-829
    • /
    • 2011
  • The purpose of the present study is to estimate the ecological instream flow for conservation and restoration of fish habitat in running water ecosystem which has very important status for stream environment. Estimation of the ecological instream flow in the present study was carried out by application of a two-dimensional depth averaged model of river hydrodynamics, River2D model. It can model fish habitat in natural streams and rivers and assess the quality of physical habitat accoriding to the species preferences for habitat suitability. Zacco platypus and Zacco temmincki were selected as target fish species in the study area of the Seomjin river. The Habitat Suitability Criteria (HSC) developed by Sung et al. (2005) were used for target fish species, life stages and habitat conditions in the study. Weighted usable area (WUA) was computed by the River2D model considering preferences of target fish species for velocity, depth, and channel substrate. The result revealed that the ecological instream flow of $10.0m^3/s$ is needed to maintain the target fish habitat at each life stage in the river.

평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험- (A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰 (Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model)

  • 이상화;이성면;박병준;이한승
    • 대한토목학회논문집
    • /
    • 제32권2A호
    • /
    • pp.123-130
    • /
    • 2012
  • 증기를 발생시켜 터빈(turbine)을 회전시키는 화력 및 원자력 발전 계통에서 냉각시설은 필수적인 구조물이며, 냉각수 순환 계통은 일반적으로 해수를 취수하여 발전소 내의 복수기까지 유입시켜 증기와 열 교환 후 다시 외해로 배출시키는 형태를 취하고 있다. 최근 냉각수 취 배수 방식을 표층 취 배수 방식이 아닌 심층 취 배수 방식으로 변경하고 있는데, 기존 원전의 재순환 온도에 대한 영향을 최소화 하고, 온배수 방류시 밀도차로 인한 부력으로 온배수 혼합효과를 높여 온배수에 의한 환경피해 범위를 최소화하기 위해서이다. 특히, 하절기에 저층의 저온 냉각수를 취수할 수 있다는 이점 때문에 향후 계획되는 발전소들도 심층 취 배수 방식을 도입할 것으로 예상된다. 본 연구에서는 원자력 발전소의 냉각시설 중 심층 취 배수 구조물의 입구 주변을 3차원 전산유체역학 코드인 $FLOW-3D^{(R)}$로 모사하여 그 흐름특성을 분석하였다. 취수구(intake)의 경우 연직취수 조건에서 유속 덮개(Velocity cap), 배수구(diffuser)의 경우 방류수의 분사방향에 변화를 주어 모의하였으며, 그 결과 취수구의 경우 유속덮개에 의한 연직 유속성분의 현저한 감소로 인한 어류 유입영향을 최소화할 수 있을 것으로 판단되며, 배수구 희석효과는 Jirka 및 Harleman이 제시한 2차원 온배수 프룸(frume)과 잘 일치 하는 것으로 나타났다.

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.