• 제목/요약/키워드: 3-D ultrasonic image

검색결과 43건 처리시간 0.024초

FE-SEM Image Analysis of Junction Interface of Cu Direct Bonding for Semiconductor 3D Chip Stacking

  • Byun, Jaeduk;Hyun, June Won
    • 한국표면공학회지
    • /
    • 제54권5호
    • /
    • pp.207-212
    • /
    • 2021
  • The mechanical and electrical characteristics can be improved in 3D stacked IC technology which can accomplish the ultra-high integration by stacking more semiconductor chips within the limited package area through the Cu direct bonding method minimizing the performance degradation to the bonding surface to the inorganic compound or the oxide film etc. The surface was treated in a ultrasonic washer using a diamond abrasive to remove other component substances from the prepared cast plate substrate surface. FE-SEM was used to analyze the bonding characteristics of the bonded copper substrates, and the cross section of the bonded Cu conjugates at the sintering junction temperature of 100 ℃, 150 ℃, 200 ℃, 350 ℃ and the pressure of 2303 N/cm2 and 3087 N/cm2. At 2303 N/cm2, the good bonding of copper substrate was confirmed at 350 ℃, and at the increased pressure of 3087 N/cm2, the bonding condition of Cu was confirmed at low temperature junction temperature of 200 ℃. However, the recrystallization of Cu particles was observed due to increased pressure of 3087 N/cm2 and diffusion of Cu atoms at high temperature of 350 ℃, which can lead to degradation in semiconductor manufacturing.

연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가 (Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images)

  • 이소희;김종운;이수열;류정원;최동혁;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권5호
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

웨이브렛 변환 평면에서 적응 필터를 이용한 초음파 비파괴검사의 스펙클 잡음 감소 (Speckle Noise Reduction of Ultrasonic NDT Using Adaptive Filter in WT Domain)

  • 전철완;전광석;이영석;이진;김덕영;김성환
    • 한국음향학회지
    • /
    • 제15권5호
    • /
    • pp.21-29
    • /
    • 1996
  • 발전소와 같은 산업 시설물들은 높은 온도와 압력 등의 환경 하에서 지속적으로 안전하게 동작하는 것이 중요하다. 초음파를 이용한 비파괴 검사는 효율적이고 간편하기 때문에 이러한 시설물의 구조적 결함이나 안전성을 조사하기 위해 널리 이용되고 있다. 본 논문에서는 불 균일한 배질의 산란 입자들에 의해 생기는 스펙클 잡음을 제거하기 위하여 웨이브렛 변환 평면(wavelet transform domain)에서 LMS 알고리즘을 적용하였다. 사용한 신호의 통계적 특성을 알기 위하여 RUN 테스트를 수행하여 신호가 비정상성을 나타냄을 보였고, WTLMS 알고리즘을 사용하여 잡음을 제거한 후 입력 자기상관 행렬의 condition number 및 독립 입력과 지연된 입력 각각에 대한 출력의 신호 대 잡음비, 그리고 3차원 영상의 관점에서 LMS 알고리즘과 비교하였다. 실험 결과 웨이브렛 변환 평면에서 LMS 알고리즘을 이용해 수행한 결과가 시평면에서 수행한 결과보다 우수한 성능을 나타내었다.

  • PDF

PSK 변조방식이 수중통신에 미치는 영향에 관한 연구 (Effects of PSK Modulation Methods in Underwater Acoustic Communication)

  • 조진수;정승백;심태보
    • 한국음향학회지
    • /
    • 제26권7호
    • /
    • pp.366-374
    • /
    • 2007
  • 수중에서 무선통신이 기존에는 초음파를 이용한 단거리통신에 국한되었으나 최근 고주파를 이용한 장거리 통신의 필요성이 증가되고 음성뿐만이 아니라 각종 데이터나 고화질 영상자료의 송수신 수요가 늘어나고 있다. 본 연구에서는 수중에서 디지털 변조방식의 차이에 따라 실제 수중통신에 미치는 영향에 대하여 연구하였다. 모의 환경 하에서 PSK기반의 변조방식(BPSK, QPSK, MSK, GMSK)에 대한 시뮬레이션을 통해 실험한 결과 GMSK만이 큰 차이를 보였다. 위 결과를 바탕으로 SNR을 35dB이하로 하고 부산 남방에 위치한 207-선(한국해양자료센타)의 15Km 구간을 모의하여 음성통신과 영상자료를 전송실험한 결과 음성통신시($10^{-2}$BER, 채널용량 1Kbps기준)는 약 8Km의 거리 차이를, 그리고 영상자료($3{\times}10^5$ 화소, 화소 당 정보량 4bit) 전송시는 BPSK, QPSK, MSK 는 60Kbps, GMSK는 45Kbps의 전송율을 확보하여 약 7초의 전송시간 차이가 생김을 확인하였다.

Image Enhancement for Sub-Harmonic Phased Array by Removing Surface Wave Interference with Spatial Frequency Filter

  • Park, Choon-Su;Kim, Jun-Woo;Cho, Seung Hyun;Seo, Dae-Cheol
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.211-219
    • /
    • 2014
  • Closed cracks are difficult to detect using conventional ultrasonic testing because most incident ultrasound passes completely through these cracks. Nonlinear ultrasound inspection using sub-harmonic frequencies a promising method for detecting closed cracks. To implement this method, a sub-harmonic phased array (PA) is proposed to visualize the length of closed cracks in solids. A sub-harmonic PA generally consists of a single transmitter and an array receiver, which detects sub-harmonic waves generated from closed cracks. The PA images are obtained using the total focusing method (TFM), which (with a transmitter and receiving array) employs a full matrix in the observation region to achieve fine image resolution. In particular, the receiving signals are measured using a laser Doppler vibrometer (LDV) to collect PA images for both fundamental and sub-harmonic frequencies. Oblique incidence, which is used to boost sub-harmonic generation, inevitably produces various surface waves that contaminate the signals measured in the receiving transducer. Surface wave interference often degrades PA images severely, and it becomes difficult to read the closed crack's position from the images. Various methods to prevent or eliminate this interference are possible. In particular, enhancing images with signal processing could be a highly cost-effective method. Because periodic patterns distributed in a PA image are the most frequent interference induced by surface waves, spatial frequency filtering is applicable for removing these waves. Experiments clearly demonstrate that the spatial frequency filter improves PA images.

세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time)

  • 배지현;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

광음향 영상화를 위한 PMN-PZT 바늘형 수중청음기 제작 (Fabrication of a PMN-PZT needle hydrophone for photoacoustic imaging)

  • ;;하강렬;김무준;강현욱;오정환
    • 한국음향학회지
    • /
    • 제35권3호
    • /
    • pp.175-182
    • /
    • 2016
  • 수 MHz의 초음파를 이용하는 저주파 광음향 영상장치에 적용하는 것을 목적으로 압전단결정 PMN-PZT를 사용한 바늘형 수중청음기를 설계 제작하고, 그 특성을 수신감도가 알려져 있는 상용 PVDF(Polyvinylidene Fluoride) 수중청음기와 비교하여 평가하였다. 설계한 수중청음기의 임펄스응답을 KLM 모델에 의해 시뮬레이션한 결과, $50{\Omega}$의 종단 임피던스에 걸리는 최대 전압을 기준으로 한 수신감도는 -261.6 dB re $1V/{\mu}Pa$이며, 2 ~ 12 MHz 대역에서 5 dB 이내의 비교적 평탄한 특성을 가지는 것으로 예측되었다. 제작한 수중청음기의 수신감도를 순음 펄스를 사용하여 측정한 결과, 측정 가능한 2 ~ 8 MHz 대역에서 상용의 수중청음기에 비해 평균 10.9 dB 높게 나타났으며, 그 값은 $-255.8{\pm}2.8$ dB re $1V/{\mu}Pa$이었다. 나아가, 제작한 수중청음기를 기계주사형 광음향 영상장치에 적용하여 머리카락에 대한 영상을 획득하였는바, 수신된 광음향 신호가 상용의 것보다 크고, 영상 또한 우수함을 알았다.

자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성 (Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment)

  • 서은희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

펄스 레이저 스캐닝 기반 초음파 영상화 기술을 활용한 원전 배관 비파괴 진단 (Nondestructive Diagnosis of NPP Piping System Using Ultrasonic Wave Imaging Technique Based on a Pulsed Laser Scanning System)

  • 김현욱;이창길;박승희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.166-173
    • /
    • 2014
  • 본 연구에서는 레이저 가진을 이용한 초음파 전파 영상 기반 배관 비파괴 검사에 관해 다룬다. 손상의 영상화를 위해 갈바노미터 기반 레이저 미러 스캐너와 Q-Switch Nd: YAG 레이저 시스템을 사용하였다. 레이저 시스템을 가진원으로 사용하면 빠른 속도로 비접촉 초음파 가진이 가능하며, 온도의 변화가 급격한 환경이나 유해 물질이 포함된 환경에서도 대상 구조물의 원거리 가진이 가능하다. 또한 공간 해상도가 높으며, 입사각이 넓어 표면 형상이 복잡한 대상 구조물도 가진이 가능하다. 본 연구에서는 이러한 레이저 시스템으로부터 생성된 유도 초음파를 단일 PZT 센서를 사용하여 계측하고, 계측된 신호는 레이저 가진점에 해당하는 좌표점에 나열함으로써 2차원 공간좌표 및 시간축을 더한 초음파 전파 영상 생성을 위한 3차원 데이터를 구성한다. 이 데이터를 시간 축에 따라 연속적으로 반복 재생하면 초음파 전파 영상을 구할 수 있다. 이 때 웨이블릿 변환을 이용하여 계측 신호의 특정 주파수 성분을 추출해냄으로써 관찰하고자 하는 특정 유도 초음파 모드를 추출할 수 있다. 이러한 일련의 과정으로부터 획득한 초음파 전파 영상 데이터를 시간-공간 영역에서 주파수-wavenumber 영역으로 변환시켜줌으로써 손상 특성을 추출할 수 있다. 본 연구에서는 손상의 진단 및 위치 추정을 위해 wavenumber 필터링 기술을 적용하였으며, 시스템 검증을 위해 다양한 배관구조물 Testbed를 대상으로 실험을 수행하였다.

유비쿼터스 디스플레이 환경에서의 사진 감상 인터페이스 (A Photo Viewing Interface in a Ubiquitous Display Environment)

  • 류한솔;최수미
    • 한국멀티미디어학회논문지
    • /
    • 제12권10호
    • /
    • pp.1363-1373
    • /
    • 2009
  • 유비쿼터스 컴퓨팅 환경으로 변화됨에 따라 사람들은 점점 더 많은 디스플레이를 이용하게 된다. 이러한 유비쿼터스 디스플레이 환경에서는 사용자가 컨텐츠에 대해서 디스플레이들과 지속적으로 인터랙션 할 수 있는 방법이 필요하다. 본 논문에서는 사용자가 여러 디스플레이를 오가며 사진을 감상할 수 있도록 연속성을 갖는 인터페이스를 제안한다. 제안 시스템은 3차원 공간상에서 사진을 보여주기 때문에 많은 수의 사진을 한 화면에 동시에 보여줄 수 있고, 큐브 메타포를 사용하여 여러 장의 사진을 그룹화 한다. 사용자는 터치스크린을 이용하여 사진을 직접 조작할 수 있으며, 다른 장소로 이동시에도 휴대하고 있는 PDA를 통해 컨텐츠를 지속적으로 이용할 수 있다. 또한 다른 디스플레이를 통해 연속적으로 인터랙션을 할 수 있다. 개발된 시스템은 사용자의 묵시적인 움직임에 따라 반응하면서도 주의를 지나치게 집중시키지 않는 앰비언트 디스플레이 형태로 설계되었다. RFID 센서와 초음파 센서를 이용하여 사용자 신인 및 디스플레이와의 접근거리를 인식하고, 사용자와 디스플레이의 근접도에 따라 보여 질 영상과 인터페이스를 파동으로 결정하게 된다.

  • PDF