• Title/Summary/Keyword: 3-D position

Search Result 2,275, Processing Time 0.034 seconds

Evaluation of Cranial Sacral Therapy (CST) Based Pillow on Sleep Induction Using the Electroencephalogram (EEG) (뇌파를 이용한 두개천골요법 기반 베개의 수면유도 효과 검증)

  • Kwon, Hyeok Chan;Phyo, Jung Bin;Park, Yong Gil;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.55-61
    • /
    • 2018
  • The purpose of this study was to investigate the effect of a pillow simulated with cranial sacral therapy (CST) on sleep induction using electroencephalography (EEG). This study included 12 voluntary participants divided into experimental group (CST group) and control group (Non-CST group) to observe EEG changes. The position of the electrode for EEG measurement consists of 8 channels electrodes (Fp1, Fp2, F3, F4, T3, T4, P3 and P4). In this study, we measured the fall asleep time, change of brain activity and sleep wave ratio using EEG wave (${\delta}$, ${\theta}$, ${\alpha}$, ${\beta}$ and ${\gamma}$). As a result, the mean fall asleep time of the experimental group was shorter than that of the control group significantly (p < 0.001). Also in comparison with the control group, both the delta (d) and theta (q) wave corresponding to the slow waves showed a larger increase and the alpha (a) wave showed a larger decrease significantly. The slow waves of experimental group showed a higher rate of significant increase than the control group (p < 0.001). Therefore this study showed that pillow based on CST had an effective in improving sleep induction and quality.

Palaeomagnetism of the Taedong Supergroup in the Kimpo Area (김포(金浦))지역 대동누층군(大同累層群)에 대한 고자적(古磁的) 연구)

  • Kim, In-Soo;Min, Kyung Duck;Lee, Mi Yeong;Kang, Hee-Cheol;Chun, Hee Young
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.193-206
    • /
    • 1993
  • A total of 111 independently oriented core samples were drilled at 12 sites in fue Kimpo area ($37.70^{\circ}N$, $126.55^{\circ}E$) of the Taedong Supergroup. The Taedong strata are composed of sandstone, conglomeratic sandstone, shale and thin coal seams. The age of the strata is known to be Late Triassic-Early Jurassic according to freshwater Esfuerites and plant fossil (Dictyophyllum-Clathropteris flora) contents. Through AF and thermal demagnetization, an area-mean ChRM direction of $D=48.3^{\circ}\;I=40.3^{\circ}\;{\alpha}_{95}=7.9^{\circ}\;k=59.5$, n=7 was obtained. It passed fold and reversal test in the formation-mean level. Fold test was not significant in the area-mean level. The palaeomagnetic north pole calculated from the area-mean lies at $46.3^{\circ}N$, $222.0^{\circ}E$ with dp=5.7, $dm=9.5^{\circ}$. This pole position is very similar to those of the South China Block (SCB) in Triassic times. Palaeolatitude of the Kimpo area in the Taedong times was $23.0^{\circ}N$, again very similar to the palaeolatitude of the South China Block in the Late Triassic. This low latitude of the study area at the time of deposition explains the tropical-subtropical nature of fossil contents of the Taedong Supergroup.

  • PDF

Pyroelectric Infrared Microsensors Made for Human Body Detection (인체 감지용 강유전체 박막 초전형 적외선 센서의 제작)

  • Choi, Jun-Rim
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.103-110
    • /
    • 1998
  • Pyroelectric infrared detectors based on La-modified $PbTiO_{3}$ (PLT) thin films have been fabricated by RF magnetron sputtering and rnicrornachining technology. The detectors form $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) thin film ferroelectric capacitors epitaxially grown by RF magnetron sputtering on Pt/MgO (100) substrate. The sputtered PLT thin film exhibits highly c-axis oriented crystal structure that no poling treatment for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency. Polymide is coated on top of the sensing elements to support the fragile structure and the backside of the MgO substrate is selectively etched to reduce the heat loss. The sensing element exhibited a very high detectivity D* of $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$ at room temperature and it is about 100 times higher than the case of micromachining technology is not used. A sensing system that detects the position as well as the existence of a human body is realized using the array sensor.

  • PDF

A Study on the Development of Evaluation Indicators for Product Safety and Air Supply Agencies (제품안전유공기관 평가지표개발에 관한 연구)

  • Shtaekova, Gulnur
    • Journal of Venture Innovation
    • /
    • v.2 no.1
    • /
    • pp.23-31
    • /
    • 2019
  • The primary goal of this study is to develop proper indicators for evaluating and selecting an organization that contributes product safety in his industry. The indicators of product safety include input, process, and output in the sequences of product safety activities and systems. The indicators are proposed by the side of measurable and unmeasurable index. In detail, the indicators are consist of 3 parts - product safe management, efforts for product safety and the performance of product safety. The indicators are itemized by size of enterprise (large, medium and small size) due to the difference of their system and management capability of product safety. To get the indicators reasonably, the opinions of experts and VOC of the industrial field are considered. And the indicators are also divided by job position and level(an executive vs. worker). The items of indicators are 20 and the score is 200, that are the same whichever the case may be. The indicators are useful tools for selecting a person who serves the development of product safety in his industry.

Localization of mandibular canal and assessment of the remaining alveolar bone in posterior segment of the mandible with single missing tooth using cone-beam computed tomography: a cross sectional comparative study

  • Alrahaimi, Saif Fahad;Venkatesh, Elluru
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.100-105
    • /
    • 2017
  • Objectives: Localization of the mandibular canal (MC) and measurement of the height and width of the available alveolar bone at the proposed implant site in the posterior segment of the mandible using cone-beam computed tomography (CBCT) in patients with a single missing tooth. Materials and Methods: A cross-sectional study was performed where CBCT scans of the patients with a single missing tooth in the posterior segment of the mandible-premolar, I (1st) molar, and II (2nd) molar were used. The scans were assessed using OnDemand3D software (version 1.0; CyberMed Inc., Seoul, Korea) for localization of the MC asnd remaining alveolar bone both vertically (from the superior position of the MC to the crest of the alveolar ridge) and horizontally (buccolingual, 3 mm below the crest of the alveolar ridge). The findings were statistically analyzed using independent t-test. Results: A total of 120 mandibular sites (40 sites for each of the three missing premolar, I molar, and II molar) from 91 CBCT scans were analyzed. The average heights (from the alveolar crest to the superior margin of the MC) at the premolar, I molar, and II molar areas were $15.19{\pm}2.12mm$, $14.53{\pm}2.34mm$, and $14.21{\pm}2.23mm$, respectively. The average widths, measured 3 mm below the crest of the alveolar ridge, at the premolar, I molar, and II molar areas were $6.22{\pm}1.96mm$, $6.51{\pm}1.75mm$, and $7.60{\pm}2.08mm$, respectively. There was no statistically significant difference between males and females regarding the vertical and horizontal measurements of the alveolar ridges. Conclusion: In the study, the measurements were averaged separately for each of the single missing teeth (premolar, I molar, or II molar), giving more accurate information for dental implant placement.

PRELIMINARY OPTICAL DESIGN OF MIRIS, MAIN PAYLOAD OF STSAT-3 (과학기술위성3호 주탑재체 MIRIS의 광학계 시험설계)

  • Yuk, I.S.;Jin, H.;Lee, S.;Park, Y.S.;Lee, D.H.;Nam, U.W.;Park, J.H.;Han, W.Y.;Lee, J.W.
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.201-209
    • /
    • 2007
  • We have preliminarily designed two infrared optical systems of the multi-purpose infrared camera system (MIRIS) which is the main payload of STSAT-3. Each optical system consists of a Cassegrain telescope, a field lens and a 1:1 re-imaging lens system that is essential for providing a cold stop. The Cassegrain telescope is identical for both of two infrared cameras, but the field correction lens and re-imaging lens system are different from each other because of different bands of wavelength. The effective aperture size is 100mm in diameter and the focal ratio is f/5. The total length of the optical system is 300mm and the position of the cold stop is 25mm from the detector focal plane. The RMS spot size is smaller than $40{\mu}m$ over the whole detector plane.

Gesture based Input Device: An All Inertial Approach

  • Chang Wook;Bang Won-Chul;Choi Eun-Seok;Yang Jing;Cho Sung-Jung;Cho Joon-Kee;Oh Jong-Koo;Kim Dong-Yoon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.3
    • /
    • pp.230-245
    • /
    • 2005
  • In this paper, we develop a gesture-based input device equipped with accelerometers and gyroscopes. The sensors measure the inertial measurements, i.e., accelerations and angular velocities produced by the movement of the system when a user is inputting gestures on a plane surface or in a 3D space. The gyroscope measurements are integrated to give orientation of the device and consequently used to compensate the accelerations. The compensated accelerations are doubly integrated to yield the position of the device. With this approach, a user's gesture input trajectories can be recovered without any external sensors. Three versions of motion tracking algorithms are provided to cope with wide spectrum of applications. Then, a Bayesian network based recognition system processes the recovered trajectories to identify the gesture class. Experimental results convincingly show the feasibility and effectiveness of the proposed gesture input device. In order to show practical use of the proposed input method, we implemented a prototype system, which is a gesture-based remote controller (Magic Wand).

The Analysis of Wideband Microstrip Slot Antenna with Cross-shaped Feedline (십자형 급전선을 갖는 광대역 마이크로스트립 슬롯 안테나의 특성 분석)

  • Jang, Yong-Ung;Han, Seok-Jin;Sin, Ho-Seop;Kim, Myeong-Gi;Park, Ik-Mo;Sin, Cheol-Je
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.3
    • /
    • pp.35-42
    • /
    • 2000
  • A cross-shaped microstripline-fed printed slot antenna having wide bandwidth Is presented in this paper. The proposed antenna is analyzed by using the Finite-Difference Time-Domain (FDTD) method. It was found that the bandwidth of the antenna depends highly on the length of the horizontal and vertical feedline as well as the offset position of the feedline. The maximum bandwidth of this antenna is from 1.975 GHz to 4.725 GHz, which is approximately 1.3 octave, for the VSWR $\leq$ 2. Experimental data for the return loss and the radiation pattern of the antenna are also presented. and they are in good agreement with the FDTD results.e FDTD results.

  • PDF

A Kinetics Analysis of Forward 11/2 Somersault on the Platform Diving (플랫폼 다이빙 앞으로 서서 앞으로 11/2회전 동작의 운동역학적 분석)

  • Jeon, Kyoung-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.3
    • /
    • pp.209-218
    • /
    • 2013
  • This study was to perform the kinetic analysis of forward $1\frac{1}{2}$ somersault on the platform diving. Six men's diving players of the Korea national reserve athletes participated in this study. The variables were analyzed response time, velocity, center of mass (COM), angle, center of pressure (COP) and ground reaction force (GRF) of motion. For measure and analysis of this study, used to synchronized to 4 camcorder and 1 force plate, used to the Kwon3D XP (Ver. 4.0, Visol, Korea) and Kwon GRF (Ver. 2.0, Visol, Korea) for analyzed of variables. The results were as follows; Time factor were observed in maximum knee flexion depending on the extent of use at phase 1 of take-off to execute the somersault. This enabled the subject to secure the highest possible body position in space at the moment of jumping to execute the somersault and prepare for the entry into the water with more ease. Regarding the displacement of COM, all subjects showed rightward movement in the lateral displacement during technical execution. Changes in forward and downward movements were observed in the horizontal and vertical displacements, respectively. In terms of angular shift, the shoulder joint angle tended to decrease on average, and the elbow joints showed gradually increasing angles. This finding can be explained by the shift of the coordinate points of body segments around the rotational axis in order to execute the half-bending movement that can be implemented by pulling the lower limb segments toward the trunk using the upper limb segments. The hip joint angles gradually decreased; this accelerated the rotational movement by narrowing the distance to the trunk. Movement-specific shifts in the COP occurred in the front of and vertical directions. Regarding the changes in GRF, which is influenced by the strong compressive load exerted by the supporting feet, efficient aerial movements were executed through a vertical jump, with no energy lost to the lateral GRF.

Effect of wearing personal protective equipment on cardiopulmonary resuscitation: Focusing on 119 emergency medical technicians (개인보호장비 착용이 심폐소생술에 미치는 영향: 119 구급대원을 중심으로)

  • Shin, Dong-Min;Kim, Seung-Yong;Shin, Sang-Do;Kim, Chu-Hyun;Kim, Tae-Han;Kim, Kyoung-Yong;Kim, Jeong-Hee;Hong, Eun-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.3
    • /
    • pp.19-32
    • /
    • 2015
  • Purpose: This study examined the effect of wearing personal protective equipment (PPE) on cardiopulmonary resuscitation (CPR), positive airway pressure, and the posture of emergency medical technicians (EMTs) when conducting CPR. Methods: Twenty 119 EMTs performed 30:2 CPR on a manikin for 4 min. Imaging data were digitized with Kwon3D XP (version 4.0). Data were collected by analyzing the motion when starting in one cycle, such as pressing to the maximum and in the final position (relaxed), and were analyzed with SPSS 18.0. Results: The angle of the elbow joints was significantly reduced (p < .05). The trunk angle was statistically significantly (p < .01, p < .001) increased. The angular velocities of the shoulder joint and left elbow joint were reduced (p > .05). The angular velocity of the trunk was significantly reduced in the starting and maximum compression postures. The hand-escape time was increased. The average compression depth was increased but not significantly (p > .05). The positive airway pressure was reduced (p > .05). Conclusion: The angle of the elbow joints and the angular velocity of the trunk were reduced, and the angle of the trunk was increased. The success of CPR and positive airway pressure was reduced.