• Title/Summary/Keyword: 3-D contact

Search Result 989, Processing Time 0.028 seconds

A Study on the Removal of Nitrogen and Phosphorus of Municipal Wastewater with Biological Coated Media (미생물 코팅 담체를 이용한 하수의 질소$\cdot$인 제거에 관한 연구)

  • Kim Young-Gyu;Cho Il-Hyoung
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.27-35
    • /
    • 2006
  • This study was carried out to investigate the removal of nitrogen and phosphorus in municipal sewage depending on existence of biological coated media in BCM reactor. The reactor with biological coated media is the process combining $A_2/O$ process. The removal efficiencies for $COD_{Mn},\; BOD_5,\;SS$, T-N and T-P were $78\%,\;90.5\%,\;92.3\%,\;61.9\%,\;60.2\%$, respectively. The specific nitrification rate$(mgNO_3-N/gMLSS{\cdot}d)$ of Contact aeration basin was 52.2 and the specific denitrification rate$(mgNO_3N/gMLSS{\cdot}d)$ in anoxic basin was 95.1. Also, phosphorus release$(mgPO_4-P/gMLSS{\cdot}d)$ in Anaerobic basin was 71.8 and Phosphorus uptake$(mgPO_4-P/gMLSS{\cdot}d)$ in contact aeration was 27.1.

The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing (안경과 콘택트렌즈 착용에 따른 근거리안위의 변화)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jun-Sung;Park, Hae-Been;Kim, Mi-Jeong;Park, Ju-Hyeong;Kim, Jin-Sol;Lee, Kyeong-Hoon;Kim, Jong-Hwan;Ha, Na-Ri
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.4
    • /
    • pp.435-443
    • /
    • 2015
  • Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.

IMGT Unique Numbering for Standardized Contact Analysis of Immunoglobulin/antigen and T cell receptor/peptide/MHC Complexes

  • Kaas, Quentin;Chiche, Laurent;Lefrane, Marie-Paule
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.209-214
    • /
    • 2005
  • Immunoglobulins (IG) , T cell receptors (TR) and major histocompatibility complex (MHC) are major components of the immune system. Their experimentally determined three-dimensional (3D) structures are numerous and their retrieval and comparison is problematic. IMGT, the international ImMunoGeneTics information system$^{\circledR}$(http://imgt.cines.fr), has devised controlled vocabulary and annotation rules for the sequences and 3D structures of the IG TR and MHC. Annotated data from IMGT/3D sructure-DB, the IMGT 3D structure database, are used in this paper to compare 3D structure of the domains and receptor, and to characterize IG/antigen, peptide/MHC and TR/peptide/MHC interfaces. The analysis includes angle measures to assess receptor flexibility, structural superimposition and contact analysis. Up-to-date data and analysis results are available at the IMGT Web site, http://imgt.cines.fr.

  • PDF

The effect of 3-mercapto-5-nitro-benzimidazole (MNB) and poly (methyl methacrylate) (PMMA) treatment sequence organic thin film transistor

  • Park, Jin-Seong;Suh, Min-Chul;Jeong, Jong-Han;Kim, Su-Young;Mo, Yeon-Gon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1174-1177
    • /
    • 2006
  • A bottom contact organic thin film transistor (OTFT) is fabricated with an organic double-layered gate insulator (GI) and pentacene. The PMMA and MNB layers are treated on gate insulator and source/drain (S/D, Au) before depositing pentacene to investigate device properties and pentacene growth. The sequence of surface treatment affects a device performance seriously. The ultra-thin PMMA (below 50A) was deposited on organic gate insulator and S/D metal by spin coating method, which showed no deterioration of on-state current (Ion) although bottom contact structure was exploited. We proposed that the reason of no contact resistance (Rc) increase may be due to a wettability difference in between PMMA / Au and PMMA / organic GI. As a result, the device treated by $PMMA\;{\rightarrow}\;MNB$ showed much better Ion behavior than those fabricated by $MNB\;{\rightarrow}\;PMMA$. We will report the important physical and electrical performance difference associated with surface treatment sequence.

  • PDF

A Study on a dynamic simulation of Current Collection System (집전시스템의 동적 수치모의 해석에 관한 연구)

  • Hur, S.;kyung, J.H.;Han, H.S.;Song, D.H.;Park, S.H.;Kim, J.S.
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.151-158
    • /
    • 1999
  • In this study, we developed the simulation program of an overhead catenary-pantograph system, The overhead catenary is modeled with point mass and the pantograph is replaced with 3 d. o. f. model which is composed of mass, spring and damper. Using the developed program, we analyzed the static structure of the overhead catenary and the dynamic characteristics of an overhead catenary-pantograph system such as uplift displacement of contact wire and contact force. we compared the analysis results with the results of GASENDO software developed at RTRI in Japan. The behaviors of uplift displacement of contact wire and contact force were similar with the results of GASENDO software.

  • PDF

Transient Thermoelastic Analysis and 3 Dimensional Stress Analysis of Carbon/Carbon Brake Disks (탄소/탄소 브레이크 디스크의 과도기 열탄성 해석과 3차원 응력해석)

  • 오세희;유재석;김천곤;홍창선;김광수
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.147-152
    • /
    • 2000
  • This paper presents the thermoelastic analysis and 3-D failure analysis of the carbon/carbon brake disk. The mechanical properties of the carbon/carbon brake disk were measured for both in-plane and out of plane directions. The mechanical properties were used as the input of the thermoelastic analysis and 3-D stress analysis for the brake disk. The gap between rotor clip and clip retainer was an important parameter in the loading transfer mechanism of the rotor. The change of gap was considered separating the mechanical deformation and thermal deformation. Because the rotor clip and clip retainers were not contacted, the clip retainers and rivets were excluded from the rotor analysis model. The disk was modeled by using the cyclic symmetry condition and the contact problem between the rotor disk and rotor clip was considered. From the results of the 3-D stress analysis, the stress concentration at the key hole of the brake disk was confirmed.

  • PDF

Bleaching Observation of Cosmetic Color Lenses According to Multipurpose Contact Lens Solutions (다목적 콘택트렌즈 용액에 대한 미용 칼라렌즈의 탈색 관찰)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.295-303
    • /
    • 2014
  • Purpose: This study aims to observe bleaching resulted from multipurpose contact lens solutions used to manage lenses with the subjects of colored contact lenses being distributed in Korea. Methods: The lenses have been worn for six months, and their refraction is 0.00D. Three types of colored contact lenses of which margin has been colored with a different manufacturing method have been adopted (type 1: pigment application method, type 2: chemical bonding process, type 3: sandwich method), and multipurpose solutions used were two types containing different components. Each of the colored contact lenses was stored in the multipurpose solutions for 20 days and went through vortexing for 15 seconds per day. Their fluorescence absorbance, surface roughness, brightness index, and color coordinate index were measured before and after the vortexing to see the degree of bleaching. Results: In the two types of multipurpose solutions, every type of the color contact lenses showed no statistically significant difference in their fluorescence absorbance value before and after the vortexing. Regarding surface image, the front surface of the lenses was smooth in every type, and about the back surface, type 3 indicated less protrusion than type 1 and 2. About the difference of color on the lens surface before and after the vortexing, type 3 showed significantly less difference than type 1 and 2; however, all fell into the permissible error. Conclusions: About the bleaching of colored contact lenses resulted from multipurpose solutions for soft contact lenses, there was no difference observed in terms of fluorescence absorbance and color. According to the methods of manufacturing dyes, however, there was difference in the protrusion of the posterior surface image.

Reliability of Measurements of Back Vertex Power for Soft Contact Lenses Using an Auto-Lensmeter (자동렌즈미터를 이용한 소프트 콘택트렌즈의 굴절력 측정 방법에 관한 신뢰도)

  • Kim, Kun-Kyu;Lee, Wook-Jin;Lee, Sun-Haeng;Kwak, Ho-Won;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Purpose: To assess the reliability for measuring the back vertex power of soft contact lenses by dry blotting and wet cell method using an auto-lensmeter. Methods: The soft contact lenses used for measurement were 5 types that were distributed in Korea, and 4 back vertex powers (-1.50D, -3.00D, -6.00D, -9.00D) were used. and repeatability and reproducibility were evaluated by measuring them with an auto-lensmeter by two examiners. Results: Measured powers by dry blotting method were ranged in mean differences from 0.03D to 0.18D for overall lenses, 0.10D to 0.18D for silicone hydrogel lenses, 0.03D to 0.08D for hydrogel lenses. The mean differences between two examiners were less than 0.10D, and the inter-examiner reproducibility was good for dry blotting method. The mean difference between powers determined by wet cell method were 0.09D to 0.69D, the mean differences between two examiners were 0.02D to 0.59D. The reliability of measurements and inter-examiner reproducibility were less than dry blotting method. Conclusions: The reliability of measurements for all materials was better in dry blotting than wet cell method, the re liability of measurements for silicone hydrogel lenses was low in both methods. In clinical practical which requires quick checking of back vertex power using an auto-lensmeter. dry blotting method is thought to be more efficient than wet cell one.

3-Dimensional Nonlinear Analysis of Low Velocity Impact On Composite Plates (복합재료 평판의 비선형 3차원 저속 충격 해석)

  • 김승조;지국현
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.38-42
    • /
    • 2000
  • In this study, the low velocity impact behavior of the composite laminates has been described by using 3 dimensional nonlinear finite elements. To describe the geometric nonlinearity due to large deformation, the dynamic contact problem is formulated using the exterior penalty finite element method on the base of Total Lagrangian formulation. The incremental decomposition is introduced, and the converged solution is attained by Newton-Raphson Method. The Newmark's constant-acceleration time integration algorithm is used. To make verification of the finite element program developed in this study, the solution of the nonlinear static problem with occurrence of large deformation is compared with ABAQUS, and the solution of the static contact problem with indentation is compared with the Hertz solution. And, the solution of low velocity impact problem for isotropic material is verificated by comparison with that of LS-DYNA3D. Finally the contact force of impact response from the nonlinear analysis are compared with those from the linear analysis.

  • PDF

Optimal Shape of Blunt Device for High Speed Vehicle

  • Rho, Joo-Hyun;Jeong, Seongmin;Kim, Kyuhong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.285-295
    • /
    • 2016
  • A contact strip shape of a high speed train pantograph system was optimized with CFD to increase the aerodynamic performance and stability of contact force, and the results were validated by a wind tunnel test. For design of the optimal contact strip shape, a Kriging model and genetic algorithm were used to ensure the global search of the optimal point and reduce the computational cost. To enhance the performance and robustness of the contact strip for high speed pantograph, the drag coefficient and the fluctuation of the lift coefficient along the angle of attack were selected as design objectives. Aerodynamic forces were measured by a load cell and HWA (Hot Wire Anemometer) was used to measure the Strouhal number of wake flow. PIV (Particle Image Velocimetry) was adopted to visualize the flow fields. The optimized contact strip shape was shown a lower drag with smaller fluctuation of vertical lift force than the general shaped contact strip. And the acoustic noise source strength of the optimized contact strip was also reduced. Finally, the reduction amount of drag and noise was assessed when the optimized contact strip was applied to three dimensional pantograph system.