• Title/Summary/Keyword: 3-Chamber

Search Result 3,208, Processing Time 0.037 seconds

A Study on the Safety Performance of the Air Chamber TMA through Accident Analysis (사고분석을 통한 에어챔버 트럭충격흡수장치의 안전성능에 대한 연구)

  • Jo, Huichang;Park, Insong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.352-357
    • /
    • 2016
  • More recently, workers and passengers of casualties has increased by rear-end collisions of unexpected while working on the road. Recently attracted air chamber TMA mounting car accidents which occurred in 3 years, and analyzed the effect of reducing the shock absorption and protection performance and casualties. There is a risk of the vehicle AIS4 more injury of high five accidents of casualties risk, also, was the analysis that there is risk of death was avoided by the air chamber TMA and SGT. Therefore, by mounting the TMA in the rear-end accident, so you can reduce the death and casualties, it must be increased this of attach rate for road construction vehicle.

A STUDY ON THE ANATOMY OF THE PULP CHAMBER FLOOR OF THE PERMANENT MAXILLARY SECOND MOLAR (상악(上顎) 제이대구치(第二大臼齒) 치수저(齒髓底)의 해부학적(解剖學的) 고찰(考察))

  • Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.53-57
    • /
    • 1981
  • A total of 130 extracted human maxillary second molars were used to study the configuration of the floor of the pulp chamber. The specimens were ground and the pulp chamber was examined with a magnifier and explored with sharp explorer. The study showed the shape of the pulp chamber, number of root canals, and the type of canal orifice. The results were as follows; 1. In so far as observing the shape of the pulp chamber of the teeth, 16.9% of the teeth were quadrilateral, 70.0% were triangle and 13.1% were ovoid shape. 2. 13.1% of the specimens have 4 root canal orifices. 73.9% have 3 root canal orifices, 11.5% have 2 root canal orifices and 1.5% have single orifice. 3. 13.1% of the specimens have 2 mesio-buccal canal orifices and among the teeth those have 3 canals, 20.8% show 'Y' shape, 29.1% show straight line and 23.8% show obtuse triangle shape.

  • PDF

Improving Compression and Throat Ratios of Combustion Chamber for Reduction of Exhaust Emissions for a Swirl Chamber Type Diesel Engine (와류실식 디젤기관의 배기배출물 저감을 위한 연소실의 압축비 및 분구면적비 개선)

  • Lee, Chang-Kyu;Huh, Yun-Kun;Seo, Sin-Won
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.3
    • /
    • pp.501-508
    • /
    • 2010
  • A swirl chamber type diesel engine attachable to 18 kW agricultural tractors was improved to reduce exhaust emissions. Compression ratio and throat area ratio of the combustion chamber were varied to determine optimum combustion conditions. Tests were composed of full load and 8-mode emission tests. Compression ratio was fixed as 21, but the swirl chamber volume was increased by 3.8%. Output power, torque, specific fuel consumption, exhaust gas temperature, and smoke level were not considerably different for compression ratios of 21.5 (reference condition) and 21 (test condition), while NOx, HC, CO and PM levels for the compression ratio of 21 were decreased by 11%, 46%, 28%, 11%, respectively, from those for the compression ratio of 21.5. The tests were also conducted with a compression ratio of 22 and 4.3% increased chamber volume. Output power, torque, exhaust gas temperature and smoke level were greater, while specific fuel consumption was less for the compression ratio of 22 than those for the compression ratio of 21.5. Increase of compression ratio decreased HC and CO levels by 24%, 39%, but increased NOx and PM levels by 24%, 39%. Based on these results, a compression ratio of 21 was selected as an optimum value. Then, full load tests with the selected compression ratio of 21 were carried out for different throat ratios of 1.0%, 1.1%, 1.2%. Output power and torque were greatest and smoke was lowest when throat area ratio was 1.1%, which satisfied the target values of specific fuel consumption (less than 272 g/$kW{\cdot}h$) and exhaust gas temperature (less than $550^{\circ}C$). Therefore, a throat area ratio of 1.1% was selected as an optimum value.

Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy (변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Park, Hyong-Hu;Kim, Donghyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • The patients who had been operated total mastectomy are different from general women in their breasts thickness due to breast surgery. As a result, digital chest image from total mastectomy patients will be different attenuation. The main objective for this study is to show that a proper Ion chamber standard combination measuring MTF which is objective basis for Digital image, when be x-ray for total mastectomy patient. We have designed the unique number that shown Left is 1, Right is 2, Center is 3 and have put the edge phantom on detector ion chamber. Lastly, we have obtained experiment images. The evaluations of all image quality have measured by 50% MTF of spatial resolution and absorption dose using Matlab(R2007a). The result showed that average exposure condition, MTF value, absorption dose for 1+3 and 2+3 combinations were 2.745 mAs, 1.925 lp/mm, 0.688 mGy. Consequently, that showed high MTF, DQE and low dose than other combinations. Therefore, a proper changes of ion chambers are able to improve image quality and to reduce radiation exposure when be X-ray for total mastectomy patients. Also, it will be possible to standard for application chamber combination and utilization on clinical detection.

A Study on the Development of Moving Watched Chamber (다중식 가두리 개발에 관한 연구)

  • Hong, Bong-Ki;Kim, In-Chul
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.93-106
    • /
    • 1995
  • This paper describes the development of moving watched chamber. For the most part, the watched chamber have been located in the inner-bay. But, there are many problems of sea-water pollution. Therefore, the watched chamber must be relocated to undeveloped coastal area. The watched chamber which is located in the bay has a bit of damage by bad weather. But, the moving watched chamber would be exposed to bad water. It is desirable to improve the system of chamber. If we make a good design of the moving watched chamber with studying of waves and hydrodynamics, it would be possible to culture fish at the coastal sea area. When a fixed system is changed into a movable one, we can obtain the following advantages: 1. The possibility of diminishing the sea water pollution, easying the overcrowded state in a inner-bay farm, and relieved of limitation caused by bad conditions such as waves, red tides and terrains. 2. It would be easy not only to move the watched chamber system in accordance with weather conditions or occurrence of red tides, but also to select good sites for watched chamber fishes. 3. Transportation and good supervision with the automated design system can results with the effectiveness which increases the amount of aquatic products.

  • PDF

Flame Visualization and Flame Characteristics of Spark Plug with Pre-ignition Chamber (예연소실 점화플러그의 화염가시화와 화염전파특성)

  • Jie, Myoung Seok;Johng, In Tae
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.51-58
    • /
    • 2016
  • New concept spark plug was developed to study its influence on the combustion characteristics of SI engine. It has pre-ignition chamber at the lower end of spark plug and flame hole, in which fresh mixture gas can be put in through the flame hole without any fuel supply system. This spark plug was tested in a single cylinder engine dynamometer for different air fuel ratio to measure the fuel consumption rate, emission gases, and MBT timing. And constant volume combustion chamber was made to understand flame characteristics of spark plug. New spark plug induced fast burn compared to the conventional spark plug and its effects were increased in lean air fuel ratio. Pre-ignition chamber spark plug with 5 holes which had adjusted size was more stable and effective in combustion performance than pre-ignition chamber spark plug with 1 hole. And its effects showed larger differences in lean air fuel ratio than stoichiometric condition. Flame kernel and flame growth process of conventional spark plug and pre-ignition chamber spark plug studied by flame visualization of schlieren method.

An Experiment on the Flow Control Characteristics of a Passive Fluidic Device (피동적 유체기구의 유동 조절 특성에 관한 실험)

  • Seo, Jeong-Sik;Song, Chul-Hwa;Cho, Seok;Chung, Moon-Ki;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.338-345
    • /
    • 2000
  • A model testing has been performed to investigate the flow characteristics of a vortex chamber, which plays a role of a flow switch and passively controls the discharge flow rate. This method of passive flow control is a matter of concern in the design of advanced nuclear reactor systems as an alternative to the active flow control to provide emergency water to the reactor core in case of postulated accidents like LOCA (Loss-Of-Coolant Accident). By changing the inflow direction in the vortex chamber and varying the flow resistance inside the chamber, the vortex chamber can control passively the injection flowrate. Fundamental characteristics such as discharge flow rate and pressure drop of the vortex chamber are measured, and its parametric effects on the performance of the vortex chamber are also systematically investigated.

Design of a piezovibrocone and calibration chamber

  • Samui, Pijush;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • v.2 no.3
    • /
    • pp.177-190
    • /
    • 2010
  • This paper presents the details of indigenous development of the piezovibrocone and calibration chamber. The developed cone has a cylindrical friction sleeve of $150cm^2$ surface area, capped with a $60^{\circ}$ apex angle conical tip of $15cm^2$ cross sectional area. It has a hydraulic shaker, coupled to the cone penetrometer with a linear displacement unit. The hydraulic shaker can produce cyclic load in different types of wave forms (sine, Hover sine, triangular, rectangular and external wave) at a range of frequency 1-10 Hz with maximum amplitude of 10 cm. The piezovibrocone can be driven at the standard rate of 2 cm/sec using a loading unit of 10 ton capacity. The calibration chamber is of size $2m{\times}2m{\times}2m$. The sides of the chamber and the top as well as the bottom portions are rigid. It has a provision to apply confining pressure (to a maximum value of $4kg/cm^2$) through the flexible rubber membrane inlined with the side walls of the calibration chamber. The preliminary static as well as dynamic cone penetration tests have been done sand in the calibration chamber. From the experimental results, an attempt has been made to classify the soil based on friction ratio ($f_R$) and the cone tip resistance ($q_c$).

The Basic Study of Internal Temperature Variation in a 3D Printer(FDM-type) Chamber (3D 프린터의 챔버 내부온도 변화에 대한 연구)

  • Shin, Geun-Sik;Kweon, Hyun-ku;Kang, Yong-Goo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.33-40
    • /
    • 2019
  • FDM 3D printers have become widespread, and investment in the 3D printer industry is increasing. Therefore, many 3D printers are released and the functions of products are emphasized. However, to lower unit prices, open-type 3D printers are sold in kit form, and their performance is very low. If the 3D printer has many heat sources and is sealed, there is the possibility that the main accessories (the main board, power supply, and motor) will be damaged by trapped heat. At the same time, if the ambient temperature is low due to the properties of the material, the output quality deteriorates. In this study, we analyzed the temperature rise of the main accessories and the quality of the output by the heat bed when a chamber was added to an open-type 3D printer. We also compared the quality of the output due to the air flow with the temperature rise of the main accessories. Moreover, we found the optimal value. As a result of the quality analysis, it was finally confirmed that the case with the chamber at $95^{\circ}C$ was the best for the printing condition. In addition, in the absence of the chamber, the bending of the specimen was found to be large, and in the case of the chamber, the degree of bending was slightly decreased by 0.05 mm.

Improvement Scheme of Field Uniformity of Stirrer Parameter in Reverberation Chamber (전자파 잔향실의 교반기 매개변수에 따른 전계 균일도 향상 방안)

  • Kim, Kwang-Yong;Hong, Joo-Il;Han, Seung-Moon;Doo, Jin-Suk;Huh, Chang-Su;Lee, Ki-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1583_1584
    • /
    • 2009
  • Reverberation chamber have become a common tool in radiated susceptibility and emission testing of electronic equipment. In a reverberation chamber, internal electromagnetic fields are mixed by metallic stirrer. Due to elimination of Polarization characteristic in reverberation chamber, electromagnetic wave reached to EUT all aspect angle. Hence, Field distribution in overmode reverberation chamber can be presented by chi-square distribution. Field uniformity in reverberation chamber have to satisfy standard deviation below 3dB and is influenced by mechanical stirrer. This paper investigates relationship between change of stirrer parameter and field uniformity in reverberation chamber.

  • PDF