• Title/Summary/Keyword: 2D scan

Search Result 640, Processing Time 0.031 seconds

Detection of Spinal Metastases: Comparison of Bone Scan and MR Imaging (전이성 척추 악성 종양의 진단 : 골스캔과 자기공명영상의 비교)

  • Kim, Ki-Jun;Sohn, Hyung-Sun;Park, Jeong-Mi;Chung, Soo-Kyo;Lee, Jae-Moon;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.384-390
    • /
    • 1994
  • Authors retrospectively compared the 99mTc MDP bone scans and corresponding MR imagings in 20 patients with histologically proven malignancy, Mean interval of the two studies was 16.6 days, Cancer diagnosis Included 8 lung, 2 each of colon, breast, stomach, 1 each of prostate, thyroid, malignant lymphoma and 3 adenocarcinoma of unknown primary site. Of the 105 regions compared, :t6 regions were positive for metastases in bone scans or MR imagings. 30 regions(65.2%) were positive by bone scan and 44 regions(95.7%) by MR imaging. 87 regions(82.9%) were concordantly positive or negative by bone scan and MR imaging, but 18 regions(17.1%) were discordant. In the discordant regions, 16 regions positive in MR imaging were negative in bone scan. The greatest number of discordant findings occured in the cervical region and in the patient with stomach cancer. Our results suggest that the sensitivity of MR Imaging is greater than that of bone scan in detecting spinal metastases. And bone scan is useful screening test of metastasis for evaluating entire skeleton including spine.

  • PDF

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

A Study on Development of the Basic Hat Pattern using 3D Scan Data for Korean Women - Focusing on the 6 pieces Crown - (3D 측정치를 이용한 여성용 모자 패턴 개발 - 6면 크라운 중심으로 -)

  • Kim, Cha-Hyun;Kim, Gum-Hwa
    • Fashion & Textile Research Journal
    • /
    • v.12 no.3
    • /
    • pp.354-363
    • /
    • 2010
  • The purpose of this study was to provide some preliminary results on application of 3D scan data of head shapes to the hat design and pattern-making. This paper defined necessary measurement items and concepts in 3-dimensional images of head shapes. And also it presented the methodology to pattern-making of 6-piece crown hat based on 3D data. It used the data of Size Korea to pick up and choose a head shape model with the average head size of Korean women in their twenties. Main results were: 1. The 3D scan data of head shape was better than the 1 dimensional measurement data. Because I could establish a hat pattern-making theory by the 3D scan data of head. 2. The 3D scan data provided the basis for conceptualization of basic measurement points and items for a better fit of hats as well as the definition of the basic hat circumference. 3. This presented a methodology for analyzing out head shape by 3D scan data, and allowed the derivation of the basic hat circumference from the maximum head circumference. 4. As the 6-piece Crown cloche hat made by this method fitted the head shape model perfectly, this methodology could suggest potential applicability to various hat design.

3D Animation Body Profiles from Full-body Scans and Motion Capture (풀바디 스캔과 모션 캡처를 활용한 3D 애니메이션 바디 프로필)

  • Jaewon Song;Sang Wook Chun;Subin Lee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.3
    • /
    • pp.59-67
    • /
    • 2023
  • This paper proposes a 3D animated body profile using 3D body scanning and motion capture devices. Users can create their own personalized body profiles with animation by performing 3D scans for a predetermined set of poses. To achieve this, a template animation was obtained through motion capture for a series of poses, and the acquired 3D scan data from users was mapped to the key poses of the animation using Pose-space deformer. The resulting 3D animated body profiles provide users with greater satisfaction compared to traditional static 2D images or 3D scan data.

Development of a Custom-Made Dress Form for Draping Based on 3D Handheld Scanners and 3D Printing Technology (3D 핸디형 스캐너와 3D 프린팅 기술 기반 드레이핑용 커스텀 메이드 드레스폼 개발)

  • Ryu, Eun Joo;Song, Hwa Kyung
    • Fashion & Textile Research Journal
    • /
    • v.24 no.4
    • /
    • pp.451-459
    • /
    • 2022
  • This study aimed to develop a a custom-made dress form for draping using a live model's 3D body scan obtained from an entry-level 3D handheld scanners, 3D modeling software and 3D printing technology. A female subject was recruited whose body size fell under the normal (N) body shape criteria suggested by KS K 0051. First, the handheld scanner reduced the length of the legs in scanning, but most of the scanning operations between the neck and crotch levels were conducted accurately. Therefore, this study was designed to develop a torso dress form. The full body 3D scan was edited into a torso shape using ZBrush® software. Using Rhinoceros® and Materialise's Magics software, a 3D body scan was modeled so that the user could fit two types of mannequin stands (one with a neck fixation from above and one with an insert from below) to the dress form. The body scan was divided into 9 pieces to fit the printable size of the Stratasys 3D printer Fortus 250mc, and the cross-sectional distance from the center to the periphery was downsized by 2 mm. After outputting the dress form scan file with a 3D printer, the dress form was manufactured by the first covering it with a 4 oz nonwoven pad and the second covering with a single jersey material.

Analysis of Body Surface Area by Fitness Motion Using 3D Scan Data of Korean Elderly Female (한국 여성 노인 3D 스캔 데이터를 활용한 피트니스 동작별 체표면적 분석)

  • Jeon, Eun-Jin;Jung, Ha-young;Kim, Hee-Eun;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.650-659
    • /
    • 2020
  • The present study provides reference data required for the design of clothing for the elderly by analyzing the body surface area during fitness motion based on 3D scan data of Korean elderly women. This study was conducted with the procedures of (1) survey of motions and main muscles for fitness, (2) acquisition of 3D scan data, and (3) analysis of rate of change for body surface area during fitness motion. Acquisition of 3D body scan data was obtained from seven elderly females (age: 64-77). We selected 66 anatomical landmarks (40 upper body and 22 lower body) by referring to previous studies. Body surface was segmented by connecting the landmarks marked on the 3D scan data acquired. Analysis of body surface area was conducted in terms of the change rate of surface area in 9 postures of elbow 0°, 90° and 180° for flexion, shoulder 90°, 180° for flexion, shoulder 0°, 180° for abduction, hip 90° for flexion, and knee 90° for flexion compared to the those in the standing posture. The amount of changes in body surface area were 12%-62% in the upper body, 15%-77% in the arm, and 10%-51% in the lower body. A future study on the rate of change of body surface length is needed; in addition, a study on how to apply the results of body surface area and body surface length analysis to clothing pattern design is also necessary.

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

STUDY ON THE COLORS OF PRIMARY INCISORS USING DIGITAL SHADE ANALYSING SYSTEM (Digital Shade Analysing System을 이용한 상악 유절치의 색조에 대한 연구)

  • Oh, Min-Hyung;Lee, Kwang-Hee;Ra, Ji-Young;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.429-437
    • /
    • 2006
  • The purpose of this study was to evaluate the shade of primary incisors. One hundred and nineteen children 394 maxillary anterior primary incisors were assessed. Digital shade analysing system ($ShadeScan^{TM}$, Cynovad, Canada) was used for measuring the shades This system enabled to improve the accuracy and objectivity The images of the teeth were taken with $ShadeScan^{TM}$ and shade maps of the teeth were obtained with $ShadeScan^{TM}$ software. The shades of three regions (cervical third middle third, incisal third) of the teeth were evaluated. The results were as follows : 1. In cervical third of primary incisors, D2 and D3 were the major shades and D2 was the most frequent shade. 2. In middle third of primary incisors, C1, D2, and B1 were the major shades and C1 was the most frequent shade. 3. In incisal third of primary incisors, A2 was the most frequent shade and D2 shade followed.

  • PDF

Application Two-Dimensional Pattern Development of Cycling Tights based on the Three-Dimensional Body Scan Data of High School Male Cyclist

  • Park, Hyunjeong;Do, Wolhee
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.595-606
    • /
    • 2020
  • This study develops an optimal two-dimensional (2D) pattern from three-dimensional human scan data by considering the cycling posture and dermatome of high school male cyclists. By analyzing the body surface change in the cycling posture and considering the dermatome of the lower limbs, the optimal cutting line setting and the development of cycling tights for individual cyclists were presented to provide data that could be used in the clothing industry. We designed three cycling tights to solve the size unsuitability. 3D design 1 is a non-extension design based on the analysis of the 3D human body scan data, in which parts were connected diagonally from the front of the knee to the back of the knee. 3D design 2 removed both the front and back to reduce air resistance during cycling. 3D design 3 did not have a cutting line on the front panel because of the air resistance during cycling in the front area. We analyzed the garment pressure for 8 points of lower body and performed a subjective evaluation of the 3D designed tights and the current cycling tights. The 3D design 1 in this study was well received in the omphalion, thigh, and hip area, while 3D design 3 was well received in the omphalion, thigh, hip, and bottom bands. Therefore, the LoNE of 3D design 1 was applied to the front, and the hip cutting line of 3D design 3 was applied to the back.