• Title/Summary/Keyword: 2Cavity

Search Result 3,193, Processing Time 0.029 seconds

A STUDY ON COMPARISON OF VARIOUS KINDS OF CLASSII AMALGAM CAVITIES USING FINITE ELEMENT METHOD (유한요소법을 이용한 수종 2급 아말감 와동의 비교연구)

  • Seok, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.432-461
    • /
    • 1995
  • The basic principles in the design of Class II amalgam cavity preparations have been modified but not changed in essence over the last 90 years. The early essential principle was "extension for prevention". Most of the modifications have served to reduce the extent of preparation and, thus, increase the conservation of sound tooth structure. A more recent concept relating to conservative Class II cavity preparations involves elimination of occlusal preparation if no carious lesion exists in this area. To evaluate the ideal ClassII cavity preparation design, if carious lesion exists only in the interproximal area, three cavity design conditions were studied: Rodda's conventional cavity, simple proximal box cavity and proximal box cavity with retention grooves. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method. Linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B option, Gap option and R option model) were developed. B option model was assumed perfect bonding between the restoration and cavty wall. Gap option model(Gap distance: $2{\mu}m$) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). R option model was assumed non-connection between the restoration and cavty wall. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as followed. 1. Rodda's cavity form model showed greater amount of displacement with other two models. 2. The stress and strain were increased on the distal marginal ridge and buccopulpal line angle in Rodda's cavity form model. 3. The stress and strain were increased on the central groove and a part of distal marginal ridge in simple proximal box model and proximal box model with retention grooves. 4. With Gap option, Rodda's cavity form model showed the greatest amount of the stress on distal marginal ridge followed by proximal box model with retention grooves and simple proximal box model in descending order. 5. With Gap option, simple proximal box model showed greater amount of stress on the central groove with proximal box model with retention grooves. 6. Retention grooves in the proximal box played the role of supporting the restorations opposing to loads.

  • PDF

A Study on Measurement and Reduction of Cavity Resonance Based on the Internal Acoustic Modeling of Compressor (공조용 압축기의 Cavity Resonance의 측정 및 저감에 관한 연구)

  • Ahn, B.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.26-33
    • /
    • 1999
  • Pressure pulsation Inside the discharge and suction cavity of rotary and scroll compressor are often a major source of objectionable noise and vibration. The key factor of these noise and vibration is due to the cavity resonance. It is not only necessary to understanding the characteristics of pulsation in order to reduce the excitation force of gas to the cavity but also to verifying the phenomena of cavity resonance. For the purpose of these understandings, measurement and simulation of cavity resonance can lead to a better understandings how they occur and be very important to identify the ways to reduce the noise efficiently. In this paper, modeling of the cavity(internal acoustics inside the shell) is discussed and simulated using FEM. Results from the simulation are compared with those measurement in experiments. In describing of cavity mode by experiments, it is very important to specify the exact conditions under which they are measured. Finally, this paper shows the one example of reduced cavity resonance in the compressor.

  • PDF

Influences of Air Cavity on the Sensitivity of a Mandrel Type fiber Optic Acoustic Sensor (Air cavity가 맨드릴형 광-음향센서의 감도특성에 미치는 영향)

  • 임종인;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.3-7
    • /
    • 2000
  • This paper is on the sensitivity characteristics of a concentric composite mandrel type fiber optic acoustic sensor with inclusion of an air cavity With the finite element method, we have analyzed sensitivity variation of the sensor in relation to its geometrical factors such as thickness of the air cavity, thickness of the foaming layer, and the ratio of inner diameter/outer diameter of the mandrel. Results of the analysis suggest a thicker air cavity, a thinner foaming layer, and a smaller ratio of the inner diameter/outer diameter of the mandrel to be desirable for higher sensitivity. The sensor structure designed with the above rules provides the sensitivity of about 0.8dB higher than that of a normal concentric composite mandrel sensor without the inherent air cavity.

  • PDF

Study of the unsteady pressure oscillations induced by rectangular cavities in a supersonic flow field

  • Krishnan L.;Ramakrishna M.;Rajan S.C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.294-298
    • /
    • 2003
  • The complex, unsteady, self-sustained pressure oscillations induced by supersonic flow past a rectangular cavity is investigated using numerical simulations. The present numerical study is performed using a parallel, multiblock solver for the two-dimensional, compressible Navier­Stokes equations. Open cavities with length-to-depth (L / D) ratio in the range 0.5 - 3.3 are considered. This paper sheds light on the cavity physics, cavity oscillatory mechanism, and the organisation of vortical structures inside the cavity. The vortex shedding phenomenon, the shear layer impingement event at the aft wall and the movement of the acoustic/compression wave within the cavity are well predicted. The vortical structures· and the source of the acoustic disturbances are found to be located near the aft wall of the cavity. With the increase in the cavity length, strong recompression of the flow near the aft wall leading to a sudden jump in the cavity form drag is observed. The estimated cavity tones are in good agreement with the available semi­empirical relation. Multiple peaks are noticed in deep and long cavities. For the present free­stream Mach number 1.71, it is observed that around L/D=2.0, the cavity oscillatory mechanism changes from the transverse to longitudinal oscillatory mode. The effects of this transition on various fluid dynamics and acoustic properties are also discussed.

  • PDF

Comparison of Protein DNA, and RNA Contents in Corpus Luteum without and with Central Cavity in Dairy Cow (젖소의 난소 황체에 있어서 중심강의 유무에 따른 Protein, DNA, RNA 함량의 비교)

  • ;Y. S. Kim;C. N. Lee
    • Korean Journal of Animal Reproduction
    • /
    • v.26 no.1
    • /
    • pp.73-78
    • /
    • 2002
  • This study was conducted to investigate total protein, DNA, and RNA content in corpus luteum(CL) without and with central cavity in dairy cow. Stage of the estrous cycle of corpus luteum from slaughterhouse(CL3, days 11 to 17) was classified by method of Ireland et. al.(1980). Corpus luteum was classified into corpus luteum without(less than 2mm in diameter) and with central cavity(more than 2mm in diameter) by method of Kastelic et. al.(1990). 1 In total protein content, CL with central cavity did not differ from CL without central cavity. 2. In DNA content, CL with central cavity was significantly lower than CL without central cavity(p<0.05). 3. In protein: DNA ratios, CL with central cavity was significantly lower than CL without central cavity(p<0.05). 4. But in RNA content, protein:RNA and RNA:DNA ratios, CL with central cavity did not differ from CL without central cavity.

AN ELECTROCHEMICAL STUDY ON MICROLEAKAGE OF RETROGRADE FILLING USING DIFFERENT RETROGRANE FILLING MATERIALS, ROOT RESECTION ANGLE AND CAVITY PREPARATION INSTRUMENTS (역충전재 및 치근단 절제 각도와 와동 형성 기구에 따른 역충전물의 변연 누출에 관한 전기화학적 연구)

  • Kim, Jin-Woo;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.499-512
    • /
    • 1994
  • The purpose of this study was to evaluate the microleakage electrochemically using different retrograde filling materials, different root resection angle, and different cavity preparation instruments. 104 extracted single-rooted teeth were selected for this study. 100 teeth were used as experimental groups and four was used as controls. Anatomical crowns were resected, root canals were prepared, and the apical 2 mm of roots were removed. The experimental roots were randomly divided into five equal groups. Experimental groups : Group 1. no bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 2. no bevel, cavity preparation with ultrasonic instruments, SuperEBA cement filling Group 3. no bevel, cavity preparation with ultrasonic instruments, desiccated ZOE filling Group 4. $45^{\circ}$ bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 5. no bevel, cavity preparation with conventional bur, amalgam filling Microleakage was measured once a day for 30 days using electrochemical method and were analyzed statistically. The results were as follows : 1. The group with Super EBA cement filling showed the least marginal leakage from second to fourth day(p<0.05), there was no significant difference between the group with amalgam filling during eighth to eighteenth day(p>0.05), but after the nineteenth day here was a higher marginal leakage than the group with amalgam filling(p<0.05). 2. The group with desiccated ZOE filling demostrated that the highest marginal leakage, started on the eighth day(p<0.05). 3. The group using ultrasonic instrument showed lower marginal leakage than the group using bur until the nineteenth day(p<0.05), but there was no significant differnce with the group using bur after twentythird day(p>0.05). 4. The group without bevel showed lower marginal leakage than the group with bevel (p<0.05). 5. Whether bevel or nor had much more effect on marginal leakage than with cavity perparation instrument when the cavity was retrogrdefilled with amalgam(stepwise regression).

  • PDF

First step of root canal therapy-access cavity preparation (근관치료의 시작 - 치수강 개방)

  • Song, Minju
    • The Journal of the Korean dental association
    • /
    • v.56 no.10
    • /
    • pp.572-580
    • /
    • 2018
  • Adequate access cavity is the key to achieving endodontic success. The aims of the access cavity can be considered as follows: 1) Creation of a smooth unimpeded pathway for instruments to canal orifices 2) Removal of the entire roof of the pulp chamber in order to inspect the pulp floor, 3) Preservation of natural tooth substance consistent with the above. Recently, contracted endodontic cavities based on minimally invasive endodontics has introduced. This has the benefit of preserving the pericervical dentin more than traditional access cavity with achieving long-term success. However, some studies reported controversial results regarding root canal detection, instrumentation efficacy (noninstrumented canal area, hard tissue debris accumulation, canal transportation, and centering ratio) as well as fracture resistance. Therefore, further studies are required for accepting contracted access cavity, and modified form of traditional and contracted access cavity could be considered.

  • PDF

Analysis of the Corner Cavity of Axisymmetric Backward Extrusion by the Upper Bound Approach (상계해석을 이용한 축대칭 후방압출 공정의 Corner Cavity 해석)

  • 박재훈;변홍석;김영호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.144-150
    • /
    • 2000
  • In this paper, the formation of a corner cavity in the final stage of axisymmetric backward extrusion process is studied by means of upper bound analysis using kinematically admissible velocity. The quantitative relationships between corner cavity formation and process parameters are studied. And analytical results are compared with those of experiment to which plasticine is used. It is found that the analytical results agree well with experimental one. In addition, to restrict the formation of a corner cavity, driven container is applied to backward extrusion and the results are compared with those of FEM. The critical thickness of the bottom of the billet decreases with increase in reduction of area, and increases with decrease in friction. To prevent the formation of corner cavity, the concept of moving container was applied. Throughout this process, the occurrence of a corner cavity is delayed and forming limit area is enlarged.

  • PDF

An Intelligent Cavity Layout Design System for Injection Moulds

  • Hu, Weigang;Masood, Syed
    • International Journal of CAD/CAM
    • /
    • v.2 no.1
    • /
    • pp.69-75
    • /
    • 2002
  • This paper presents the development of an Intelligent Cavity Layout Design System (ICLDS) for multiple cavity injection moulds. The system is intended to assist mould designers in cavity layout design at concept design stage. The complexities and principles of cavity layout design as well as various dependencies in injection mould design are introduced. The knowledge in cavity layout design is summarized and classified. The functionality, the overall structure and general process of ICLDS are explained. The paper also discusses such issues as knowledge representation and case-based reasoning used in the development of the system. The functionality of the system is illustrated with an example of cavity layout design problem.

Effects of Risering Design and Chemical Composition on Formation of Shrinkage Cavity in Gray Cast Iron (회주철의 수축결함생성에 미치는 주조방안 및 화학조성의 영향)

  • Yu, Sung-Kon
    • Korean Journal of Materials Research
    • /
    • v.13 no.5
    • /
    • pp.297-302
    • /
    • 2003
  • The effects of risering design and alloying element on the formation of defects such as external depression, primary and secondary shrinkage cavity in gray cast iron were investigated. Two types of risering design for the cylindrically step-wise specimen, No. 1(progressive solidification) and No. 2(directional solidification) risering designs, were prepared and five different alloy compositions were casted. In the No. 1 risering design, external depression or primary shrinkage cavity due to liquid contraction was observed in all the specimens from ISO 150 to ISO 350. The primary shrinkage cavity was located right under the top surface or connected to the top surface, and was characterized by smooth surface. Its size increased with an increase in ISO number. However, neither secondary shrinkage cavity nor swollen surface was observed in all the castings. In the No.2 risering design, neither primary shrinkage cavity nor secondary shrinkage cavity was observed in all the specimens due to proper risering design. A swollen surface was also not observed in all the castings with the application of pep-set mold.