• Title/Summary/Keyword: 2 step protection system

Search Result 44, Processing Time 0.022 seconds

The Research on the Development Steps and Facing Problems of Korean and Japanese Laver Industry (한일 김산업의 발전과정 분석과 당면과제 연구)

  • Ock, Young-Soo
    • The Journal of Fisheries Business Administration
    • /
    • v.42 no.2
    • /
    • pp.113-130
    • /
    • 2011
  • The laver has been cultivated long time ago by Korea and Japan. Korean Laver Industry has been influenced by Japan on the many factors since 20th. Nevertheless now the both country showed widening disparities across the aspect of total Laver Industry each other. The development steps of Korea and Japan Laver Industry have been advanced differently. That is, we can keep the Laver Industry development steps of both countries separate by 4 steps. But insignificant of every step against both countries has been dissimilar. We can separate from 4 steps in Korea, 1 step is origin period from beginning of laver cultivation to 1961. Next step is First Development period from 1962 to 1978. This period come out production increase from about 10,000 tons early 1960 to 50,000 tons late 1970. Next step is Second Development period from 1979 to 2000. This period come out eminent production increase from about 50,000 tons early 1980 to 200,000 tons late 1990. Next step is Stabilization period from 2001 to now. This period come out production control the size of its production and enlargement of Laver Export. We can also separate from 4 steps in Japan, 1 step is origin period from beginning of laver cultivation to 1944. Next step is Development period from 1945 to 1975. This period come out production increase from about 4 billion sheets early 1960 to 8.5 billion sheets 1975. Next step is Peak period from 1976 to 1982. This period come out sustainable production peak by 6~8 billion sheets and high price. Next step is Decline period from 1983 to now. This period come out production control the size of its production and sustainable price down. These differences showed out facing problems of Korean and Japanese Laver Industry differently. In case of Korea, the facing problems show out 3. First is structural problem, for example, trouble between original laver producer and the finished producer by dry laver products. Second is Insufficiency of Plants Protection System. Third is low quality of Laver. In case of Japan, the facing problems also show out 3. First is sustainable decrease of laver consumption. Second is change of mind against laver, for example, the change of the propensity to consume, and decrease of brand power. Third is Influence of global system. The difference of development steps of Korea and Japan Laver Industry show out 2 point of view to us. First we need consider positive strategy against laver production system of enlargement. Second, we need consider separate strategy against high quality laver and low quality laver.

Delphi Study on the Reduction of Cross-contamination and Improvement of Management System on Firefighting Protection Suit (소방 방화복 교차오염 저감 및 관리체계 개선을 위한 델파이 연구)

  • Kim, Soo Jin;Ham, Seunghon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.182-194
    • /
    • 2022
  • Objectives: This study evaluates and recommends the priority of policy implementation to improve the fire protection clothing management system used by firefighters and the reduction of cross-contamination from contaminated clothing at the scene of a fire. Methods: It consisted of 7 experts and conducted three interviews and two modified Delphi surveys. Through the results of previous research and interviews with experts, a plan to reduce cross-contamination of fire suits and improve the management system was first derived. An improvement plan was presented in the four areas including resources, management, fire protection related work, and laws and regulations, and the priority of policy implementation was derived by analyzing the importance and practicality of the policy at the same time. Results: As a result of the analysis, the first priority was education on the health effects of pollutants at the disaster scene for firefighters, and the second priority was the addition of SOP for the primary decontamination of on-scene personal protective equipment in preparation for the health effects of the disaster scene, and education for fire suppression and rescue workers. The next step was to improve the management system of personal protective equipment such as fire suits and develop a training course for systematic operation. Conclusions: This findings could be used in the implementation of mid- to long-term firefighting policies for the systematic operation and establishment of a systematic management system for personal protective equipment such as fire protective suits.

Design of the Ground Resistance Measuring System to the Earth-Noise

  • Jung Min-Jae;Joo Hyung-Jun;Lee Ki-Hong;Oh Sung-Up;Jung Jae-Ki;Seong Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.566-570
    • /
    • 2001
  • Generally, grounding systems are responsible for the safe operation of a power system. Their performance guarantees equipment protection and personnel safety under condition of the limited ground potential rise and touch voltages as well as step voltages under ground fault conditions. Therefore, it is necessary to measure the ground resistance frequently for checking the performance of grounding system, In this paper the ground resistance measuring system using digital signal processor and high-performance L-C resonant band pass filter is presented. The signal current magnitude for measuring ground resistance in this system is $10^{-1}[A]\;to\;5\times10^{-2}[A]$ and the current frequency is 30[Hz].

  • PDF

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

A Study on Voice over Internet Protocol Security Response Model for Administrative Agency (행정기관 인터넷전화 보안 대응 모델 개발 연구)

  • Park, Dea-Woo;Yang, Jong-Han
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.237-240
    • /
    • 2011
  • Voice over Internet Protocol calls using administrative agency to build a national information and communication service, 'C' group, providers, the KT, SK Broadband, LG U+, Samsung SDS, as there are four operators. To prepare for an attack on Voice over Internet Protocol for administrative agency, security is a need for research to support the model. In this paper, the Internet telephone business of Administrative Agency to investigate and analyze the specific security measures to respond. Should set priorities around confidentiality about five security threats from NIS to Study of Voice over Internet Protocol Security Response Model for Administrative Agency. (1) Illegal wiretapping, (2) call interception, (3) service misuse, (4) denial of service attacks, (5) spam attacks, write about and analyze attack scenarios. In this paper, an analysis of protection by security threats and security breaches through a step-by-step system to address the research study is a step-by-step development of the corresponding model.

  • PDF

Adaptive Video Watermarking using the Bitrate and the Motion Vector (비트율과 움직임 벡터를 이용한 적응적 동영상 워터마킹)

  • Ahn, I.Y.
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.37-42
    • /
    • 2006
  • This paper proposes a adaptive video watermarking algorithm according to bitrate and motion vector size in MPEG2 system. The watermark strength in the I-frames is adapted for quantization step size and the strength in the P-B-frames is adapted for quantization step size and motion vector of macroblock to make the watermark more robust against the accompanying degradation due to aggressively compression. A realtime watermark extraction is done directly in the DCT domain during MPEG decoding without full decoding of MPEG video. The experimental simulations show that the video quality results almost invisible difference between the watermarked frames and the original frames and the watermark is resistant to frame dropping, MPEG compression, GoP conversion and low pass filter attacks.

Analysis of Ecological Landscape Planning and Policy in Germany (독일의 생태학적 조경계획 정책분석 -독일 자연환경보존법을 중심 으로-)

  • ;L, Finke
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.2
    • /
    • pp.105-122
    • /
    • 1994
  • The landscape plannings were composed of the fundamental provisions which are important factors for the city and local plannings in Germany. The State Government run institute like LOLF in NRW have been established to solve the serious ecological problems. The institute have completed the basic system covering various ecological problems, such as environmental affection analysis and ecological risk, to contribute the application of the various land-using plants. The ecological landscape plannings are regarded as major fundamental plans of environmental preservation for the plannings development. The problems about the local landscape plannings needed to be preserved ecologically are introduced into the Federal Nature Preservation Law and State Congress Law in order to carry out the environmental protection policy effectively. The local landscape plannings are divided into two-step models by the special classification system for the planning. One is build-up of an independent design separated from city plans functionally, and the other is a systematic regulation for cooperation between the local plans and ecological conservation functions. The local plannings including lands to be preserved as the Nature Preservatin Zone is classified a rest area total sectioned plains.

  • PDF

A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System (기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.31-37
    • /
    • 2012
  • This paper describes to analyze the ventilation performance of a room air conditioner for indoor comfort control. An experimental apparatus consists of a test room, the room air conditioner, a tracer gas measurement system, a supply fan and a controller. Ventilation performance as a function of human occupancy is evaluated with supply ventilation air using a tracer gas technique of CO2 gas in the test room. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 and is found to increase with increasing supply ventilation rate. The CO2 gas concentration is decayed rapidly without human occupancy. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570 lpm comparing with a natural reduction after one hour. A modeling for ventilation performance of a room air conditioner in a test room is presented using experimental datum.

Determination of Reasonable Amounts of Under-Voltage Load Shedding for 765kV T/L According to the Power System Reliability Standards (전력계통 신뢰도 기준 분석을 통한 765kV 선로사고에 대한 부하차단 적정량 산정에 관한 연구)

  • Yoo, Je-Ho;Hur, Jin;Cha, Jun-Min;Kim, Tae-Gyun;Kang, Bu-Il;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.845-851
    • /
    • 2015
  • Load shedding is a last measure to avoid nationwide cascading collapses of power system by removing the pre-determined amount of loads from the main grid. In Korea, SPS(Special Protection System) is prepared to keep the power system stability from the extreme contingency of the critical transmission line losses. Among them, we need to pay attention to 765kV T/L’s because they have great influence on the total system stability. According to the present SPS operating guide, the total loads of 1,500MW should be removed through 2 step under-voltage load shedding(UVLS) scheme in case of 765kV T/L’s contingencies. However, it is not clear to defined how to determine the typical load reduction amounts for each case. This paper proposes a method to estimate appropriate amounts of load shed for 765kV T/L’s contingencies by analyzing the relevant national and international standards.

Model predictive control strategies for protection of structures during earthquakes

  • Xu, Long-He;Li, Zhong-Xian
    • Structural Engineering and Mechanics
    • /
    • v.40 no.2
    • /
    • pp.233-243
    • /
    • 2011
  • This paper presents a theoretical study of a model predictive control (MPC) strategy employed in semi-active control system with magnetorheological (MR) dampers to reduce the responses of seismically excited structures. The MPC scheme is based on a prediction model of the system response to obtain the control actions by minimizing an objective function, which can compensate for the effect of time delay that occurred in real application. As an example, a 5-story building frame equipped with two 20 kN MR dampers is presented to demonstrate the performance of the proposed MPC scheme for addressing time delay and reducing the structural responses under different earthquakes, in which the predictive length l = 5 and the delayed time step d = 10, 20, 40, 60, 100 are considered. Comparison with passive-off, passive-on, and linear quadratic Gaussian (LQG) control strategy indicates that MPC scheme exhibits good control performance similar to the LQG control strategy, both have better control effectiveness than two passive control methods for most cases, and the MPC scheme used in semi-active control system show more effectiveness and robustness for addressing time delay and protecting structures during earthquakes.