• Title/Summary/Keyword: 2차원 스캐너

Search Result 131, Processing Time 0.027 seconds

Fast 3D mesh generation using projection for line laser-based 3D Scanners (라인 레이저 기반 3차원 스캐너에서 투영을 이용한 고속 3D 메쉬 생성)

  • Lee, Kyungme;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.513-518
    • /
    • 2016
  • This paper presents a fast 3D mesh generation method using projection for line laser-based 3D scanners. The well-known method for 3D mesh generation utilizes convex hulls for 4D vertices that is converted from the input 3D vertices. This 3D mesh generation for a large set of vertices requires a lot of time. To overcome this problem, the proposed method takes (${\theta}-y$) 2D depth map into account. The 2D depth map is a projection version of 3D data with a form of (${\theta}$, y, z) which are intermediately acquired by line laser-based 3D scanners. Thus, our 2D-based method is a very fast 3D mesh generation method. To evaluate our method, we conduct experiments with intermediate 3D vertex data from line-laser scanners. Experimental results show that the proposed method is superior to the existing method in terms of mesh generation speed.

Assessment of over / under-break of tunnel utilizing BIM and 3D laser scanner (3차원 레이저 스캐너 및 BIM을 활용한 터널 과대.과소 굴착 평가)

  • Park, Jeong-Jun;Shin, Jae-Chou;Hwang, Ju-Hwan;Lee, Kang-Hyun;Seo, Hyung-Joon;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.437-451
    • /
    • 2012
  • Application of 3D laser scanner to civil engineering is widely studied in various fields such as tunnel, bridge, calculation of earth volume, construction measurement, observation of rock joint, etc. Some studies on utilization of the 3D laser scanner for calculating the over-break and/or under-break of tunnels have also been carried out. However, in the previous research, the scanning data were usually compared with the 2D CAD blueprint results; although the shape of tunnel structure is relatively simple, for precise calculation of the over-break and/or under-break of tunnels, three-dimensional analysis based on BIM is needed. Therefore, in this paper, a new program that calculates the over-break and/or under-break of tunnels using the 3D laser scanner and the BIM is developed; moreover the effective and rapid process of data treatment is proposed. The accuracy of the developed program was verified by applying the new system to a real tunnels construction field.

Design of Face Recognition Algorithm based Optimized pRBFNNs Using Three-dimensional Scanner (최적 pRBFNNs 패턴분류기 기반 3차원 스캐너를 이용한 얼굴인식 알고리즘 설계)

  • Ma, Chang-Min;Yoo, Sung-Hoon;Oh, Sung-Kwun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.748-753
    • /
    • 2012
  • In this paper, Face recognition algorithm is designed based on optimized pRBFNNs pattern classifier using three-dimensional scanner. Generally two-dimensional image-based face recognition system enables us to extract the facial features using gray-level of images. The environmental variation parameters such as natural sunlight, artificial light and face pose lead to the deterioration of the performance of the system. In this paper, the proposed face recognition algorithm is designed by using three-dimensional scanner to overcome the drawback of two-dimensional face recognition system. First face shape is scanned using three-dimensional scanner and then the pose of scanned face is converted to front image through pose compensation process. Secondly, data with face depth is extracted using point signature method. Finally, the recognition performance is confirmed by using the optimized pRBFNNs for solving high-dimensional pattern recognition problems.

Measuring Leaf Areas with a Structured-Light 3D Scanner (3차원 구조광 스캐너를 이용한 식물의 잎 면적 측정 방법)

  • Nam, Kyong-Hee;Ko, Eun Mi;Mun, Saeromi;Kim, Chang-Gi
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.232-238
    • /
    • 2014
  • We have developed a non-destructive, touch-free method for estimating leaf areas with a structured-light three-dimensional (3D) scanner. When the surfaces of soybean leaves were analyzed with both the 3D scanner and a leaf area meter, the results were linearly related ($R^2=0.90$). The strong correlation ($R^2=0.98$) was calculated between shoot fresh weights and leaf areas when the scanner was employed during growth stages V1 to V4. We also found that leaf areas measured by the scanner could be used to detect changes in growth responses to abiotic stress. Whereas under control conditions the areas increased over time, salt and drought treatments were associated with reductions in those values after 14 d and 12 d, respectively. Based on our findings, we propose that a structured-light 3D scanner can be used to obtain reliable estimates of leaf area and plant biomass.

Analysis of Accuracy and Productivity of Terrestrial Laser Scanner for Earthwork (3차원 스캐너의 토공현장 적용을 위한 정밀도 및 생산성 분석)

  • Kim, Seok;Park, Jae-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.10
    • /
    • pp.587-596
    • /
    • 2015
  • 3D scanners are applied to many industries, such as manufacturing, construction, and shipbuilding. Recently, 3D scanner is used in 3D imaging of worksite in order to control and guide earthmoving heavy equipments, which provides basic information for intelligent excavation. This study compares the accuracy and productivity between total stations and high-resolution 3D scanners. The analysis results show that 3D scanner has high accurate rate of greater than 99 percent and has low error rate of less than 2.0mm compared to total stations. In terms of productivity, 3D scanner saves 71 percent of measuring time compared to the total station. This study confirms that 3D scanner can measure the earthwork sites with high accuracy and better productivity.

A Study on the Evaluation of Repeated Measurement Stability of 3D Tooth Model Obtained by Several Dental Scanners (수종의 치과용 스캐너로 채득된 3차원 치아 모형의 반복측정 안정성 평가 연구)

  • Bae, Eun-Jeong;Kim, Won-Soo;Lim, Joong Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.5
    • /
    • pp.996-1003
    • /
    • 2021
  • The purpose of this study is to evaluate the reliability of repeated measurements of several dental scanners. Blue-lighted scanners, white-light scanners and optical-type scanners are used in the study of repeatability in this study. The measurement results were calculated as root mean square (RMS) and the significance level was confirmed by applying the 1-way ANOVA statistical technique (𝛼=.05). According to the statistical analysis, the scanner with the largest RMS value was Z-opt group (38.2 ㎛. Next, D-white was 35.2 ㎛ and the group with the lowest RMS value was I-blue (34.1 ㎛). The comparison of RMS means between each group was not significant (p>.05). From this result, the blue light had the lowest error in repeatability of dental scanners, but no statistical significance. The conclusion of this study is that the study results are clinically acceptable.

Study of Servo Controller for Improving Position Accuracy of 3D Terrestrial Laser Scanner (지상용 3차원 레이저 스캐너의 측정 위치 정확도 향상을 위한 서보 제어기의 연구)

  • Yu, Jong-Wook;Jeong, Joong-Yeon;Kim, Tae-Hyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.187-194
    • /
    • 2009
  • This study is to improve position accuracy by selecting proper a servo motor and applying FOC(Field Oriented Control) on developing a 3D terrestrial laser scanner. A 3D terrestrial laser scanner under developing has range of scanning of azimuth 360$^\circ$and elevation 270$^\circ$. It is implemented by precise controlling of a azimuth motor and a elevation motor. In the consequence of study, we have known that position accuracy of the motor can be able to be improved with constant torque of the motor by using FOC(Field Oriented Control). The control technic of the motor is possible to apply a 3D terrestrial laser scanner as well as a robotic total station.

3D Indoor Modeling Based on Terrestrial Laser Scanning (지상레이저스캐닝 기반 3차원 실내 모델링)

  • Hong, Seung Hwan;Cho, Hyoung Sig;Kim, Nam Hoon;Sohn, Hong Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.525-531
    • /
    • 2015
  • According to the increasing demand for 3D indoor spatial information, the utilization of a terrestrial laser scanner comes to the fore. However, the research for the comparison between a terrestrial laser scanning method and a traditional surveying method is insufficient. The paper evaluated the time-efficiency and the locational accuracy of an AMCW type and a direct TOF type of terrestrial laser scanning methods in comparison with the observation using a total station. As a result, an AMCW type showed higher time-efficiency than a direct TOF type and the RMSE between the two types of data was ${\pm}1mm$. Moreover, the terrestrial laser scanning method showed twice higher time-efficiency than the observation using a total station and the RMSE between the two data was ${\pm}3.4cm$. The results indicate that the terrestrial laser scanning method has better profitability and performance for 3D indoor modeling than the traditional survey using a total station. In the future, a terrestrial laser scanner can be efficiently utilized in the construction of 3D indoor spatial information.

Design of foot parameter measurement system in 3D Point cloud (3D 점군 데이터에서의 발 고유 변인 검출 시스템 설계)

  • Yun, Jeongrok;Kim, Un Yong;Kim, Hoemin;Chun, Sungkuk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.695-696
    • /
    • 2021
  • 최근 다양한 연령층과 직업군들 사이에서 기능성 신발에 대한 관심이 증대되고 있다. 그러나 기능성 신발 및 맞춤형 신발은 높은 가격대와 긴 제작 시간이 필요하다. 이러한 문제점은 3D 스캐너 도입으로 해결이 가능하나, 정확한 발 형상 측정이 가능한 3D 스캐너는 고가의 장비이기 때문에 매장별 보급이 어렵다. 본 논문은 기능성 신발의 보급을 위하여 저가형 3D 스캐너에서 정확한 발 고유 변인을 측정할 수 있는 시스템에 대해 서술한다. 이를 위해 이를 위해 저가형 Depth Camera를 이용한 저가형 3D 스캐너의 발 형상 3D 점군 데이터를 2차원으로 변형하고, 발 형태를 감싸는 최소 사각형(Min Area Rect)를 형성하여 발 안쪽점 및 발 가쪽점을 추정한다. 생성된 최소 사각형과 발 안쪽점 및 발 가쪽점 등은 발 고유 변인 측정의 기준이 된다. 실험 결과에서는 측정 기준을 이용하여 발 고유 변인인 발 길이, 발 너비, 발꿈치 너비, 발꿈치에서 발안쪽점 및 발 가쪽점 길이 등 5가지 고유 변인을 측정하는 것을 보여준다.

  • PDF