• Title/Summary/Keyword: 2면 전단실험

Search Result 172, Processing Time 0.026 seconds

A Study on the Size Change of the Shear Surface by the Clearance in the Shaving Process (셰이빙 공정에서 클리어런스에 의한 전단면의 크기 변화에 관한 연구)

  • Jeong, Sang-Jun;Sung, Si-Myung
    • Industry Promotion Research
    • /
    • v.1 no.2
    • /
    • pp.1-6
    • /
    • 2016
  • By using the high tensile steel plate (SPFH590) 1 Primary normal shear process clearance was studied through an experiment for the effect of the second shaving process in this study. Experiment result, Shaving process in the case of processed 15% of the Primary normal shear process clearance was some residual surface does not remove it completely. and Shaving process of shearing products by the general shearing process clearance of 10% it was found that the wider the size of shear surface. The shear surface of 93% occurred in case of the clearance of general shearing process is 10% and the Shaving clearance is 2%, The shear surface of 87% were to occur in case of the Shaving clearance is 3%.

Evaluation on the Horizontal Shear Strength of Precast Concrete Slab with the Inverted-Rib-Plus (리브플러스 PC슬래브의 수평전단강도 평가)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Yun Cheul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.156-165
    • /
    • 2011
  • This study investigates the horizontal shear behavior of an interface between precast concrete (PC) and topping concrete(RC), and evaluates the horizontal based on the investigations by the experimental. Horizontal shear strength in connected surface is determined by the roughness an interface and the shear reinforcement or not. In this study, the main experimental parameters are the shear reinforcement types in the shape of loop-type and lattice-type, rebar spacing. A total of four specimens were shear strength tested and manufactured. As a result, the horizontal shear strength of reinforced connected surface was found to be controlled by deformation in vertical direction. Comparison of reinforcement shape, the mean initial crack load loop type specimens, the average maximum load and the junction of the average in terms of initial stiffness, respectively 33.7%, 45.9% and 55.2% were large enough. Evaluation results for shear strength equation of existing standard domestic, the loop-type reinforced 2.32 to 4.23 times, lattice-type reinforced 1.65 to 3.06 times appears to be higher. Behavior of interface or strength of structural design criteria was fairly safe side. It does not have any problems in the applied field is considered.

Anisotropic Shear Strength of Artificially Fractured Rock Joints Under Low Normal Stress (낮은 수직응력 하에서 인공 절리면의 전단 이방성에 관한 연구)

  • 곽정열;이상은;임한욱
    • Tunnel and Underground Space
    • /
    • v.13 no.3
    • /
    • pp.169-179
    • /
    • 2003
  • Anisotropic shear strength of rock joints is studied based on the artificially fractured specimens using experimental and analytical methods. Series of direct shear tests are performed to obtain the strength, stiffness and friction angle of joints under various low normal stresses and shearing directions. The results of shear strength and stiffness show anisotropic value according to shearing direction under low normal stress specially less than 2.45 MPa. But, the effect of joint roughness on strength decreases with increasing normal stress. To estimate more effectively the peak shear strength under low normal stress, the modified Barton's equation is suggested.

A Study on the change of shape of the flume cross section for the control of bottom shear stress distribution of an annular flume (환형수조의 바닥전단응력 균일화를 위한 수조단면의 형상변화에 대한 연구)

  • Yang, Su-Hyun;Im, Ik-Tae;Hwang, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.177-177
    • /
    • 2011
  • 환형수조는 점착성 퇴적물의 침/퇴적실험을 위한 실험장치로서, 수조내부의 수면과 접하여 회전하는 상부링(top ring)의 마찰력에 의해 흐름이 생성되며, 시간의 제약없이 흐름조건을 동일하게 만들 수 있다는 큰 장점을 갖는다. 그러나 환형수조는 원주유속의 속도차이 및 원심력으로 인한 2차 순환류가 형성되어 바닥전단응력이 불균일해지는 단점을 가지고 있으며, 이러한 이유로 인하여 환형수조를 이용한 침/퇴적실험 수행시 수조의 외벽부근에서 더 큰 침식이 발생한다. 따라서, 2차 순환류의 발생을 줄이고 바닥전단응력의 분포를 균등하게 하기 위해 양방향 회전(환형수조의 몸체를 상부링의 회전방향과 반대방향으로 회전)이 가능한 환형수조가 고안되었는데, 이러한 방법으로 2차 순환류의 크기를 저감시키고, 바닥전단응력을 균일하게 만들 수 있다. 한편, 환형수조의 양방향 회전(counter-rotation)은 현장용 환형수조에는 적용될 수 없는 단점을 갖는다. 현장실험에서는 바닥면이 없는 현장용 환형수조를 해저면에 거치시켜 자연상태의 비교란 퇴적물 시료를 저면으로 형성시키는데, 바닥면이 존재하지 않는 환형수조 본체는 회전시킬 수 없으므로 양방향 회전을 통한 2차 순환류의 저감 및 바닥전단응력 균일화의 효과를 기대할 수 없다. 이러한 이유로 환형수조의 양방향 회전은 단지 실내실험용 환형수조에만 적용된다. 이에 본 연구에서는 환형수조 본체를 회전시키지 않고 수조의 측벽과 상부링의 각도 조절을 통해 수조단면의 형상을 변화시켜 2차 순환류를 저감시키고 바닥전단응력을 균등하게 하는 방법에 대한 연구가 수행되었다. 이 방법은 본체의 회전이 필요 없으므로 현장용 환형수조에 적용될 수 있을 뿐만 아니라, 실험장치의 구조가 단순해져 실험장치의 제작비가 절감될 수 있다. 또한 원주속도에 수직한 단면에서 속도구배가 감소되어 2차 순환류가 저감됨과 동시에 바닥전단응력이 균등하게 됨으로서 양방향 회전시와 동일한 효과가 얻어질 수 있을 것으로 예상된다.

  • PDF

An Experimental Study on the shear connection for UHPC Deck Bridge (초고성능 콘크리트 바닥판 교량의 전단연결부에 대한 실험적 연구)

  • Yoo, Dong-Min;Hwang, Hoon-Hee;Kim, Sung-Tae;Park, Sung-Young
    • Composites Research
    • /
    • v.24 no.5
    • /
    • pp.29-33
    • /
    • 2011
  • The application of high performance materials for the deck can represent a fair alternative to reduce the weight of the deck and improve the econimic efficiency of the bridge even if high performance materials are costly. In UHPC(Ultra High Performance Concrete) bridges, it is necessary to verify that exiting headed stud can be used to transfer longitudinal shear forces across the steel-concrete interface. In this paper, the push-out tests are performed to analisys the composite behavior between UHPC bridge deck and steel girder. The ultimate strength of test specimens is proportional to the diameter of headed studs in push-out test for static loading. Test results show that the shear strength of headed stud is improved for the case of normal concrete bridge decks.

A Study on the share surface size deformation of Fine Blanking Process (파인블랭킹 공정에서 전단면의 크기 변형에 관한 연구)

  • Lee, Chun-Kyu;Kim, Young-Choon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3650-3655
    • /
    • 2013
  • A state purpose to produce fine blanking die gets to be the maximum size of share surface the study considered that change a size of share area. the clearance affecting most greatly size of share surface fixing as 1% of material thickness and while change share speed, A distance change from share line to V-ring center, A change of V-ring angle. it designed. Each test specimen taken from the share surface size analysis of the V-ring distance of 2mm, the outer $45^{\circ}$ / inner$30^{\circ}$ if the, Shear speed was found that the area of the entire cross section is largest the 6.4m/min.

Relationship between shear behavior characteristics and mechanical parameters of fractures (절리면에서의 전단거동 특성과 역학적 파라미터들 간의 상관성)

  • 이종욱;이찬구;황신일;장천중;최원학
    • The Journal of Engineering Geology
    • /
    • v.3 no.1
    • /
    • pp.1-20
    • /
    • 1993
  • In this study, laboratory direct shear tests on 37 core specimens of gneiss were performed to examine the characteristics of shear behavior on fractures by using a portable direct shear box. The multi-stage shear testing method was used and normal stress applied to specimens ranges from 5.60 to $25.67kg/\textrm{cm}^2$. On the basis of test results, the empirical equations for the shear strength on fractures were suggested. The methanical parameters that can influence the shear behavior were derived and compared between each parameter. The values of shear stiffness have a trend showing rapid increase with the increase of normal stress and joint roughness coeffident, and the average value of secant shear stiffness for all specimens is about $110.68kg/\textrm{cm}^3$ under the range of normal stress applied in this test In addition, the relationship between the length of specimen and shear stiffness is inversely correlated due to the size effect. Therefore, even the specimens with the same joint roughness coeffident show the trend of decreasing shear stiffness in case of the specimens being the longer length.

  • PDF

Experimental Study on Interface Shear Strength of Concrete in Vertical Construction Joint (콘크리트 수직시공이음 접합면의 전단강도에 대한 실험적 연구)

  • Kim, Ook-Jong;Kim, Young-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.125-129
    • /
    • 2004
  • In masive concrete placement, cracking problem due to hydration heat is frequently encountered. One of measure to solve this problem is to make a construction joint. However, it is cumbersome to make it by chipping the surface of joint. In this study, push-out test for 18 specimens was conducted to compare the interface shear strength of consturction joints whose surfaces were prepared with three methods; chipping, rib-lath, folded rib-lath. Compared to the specimens made with conventional surface chipping, those with rib-lathe showd excellent preformance increasing shear resistance capacity and the role of shear key conceived by folding rib-lath played important role in enhancing shear resistance.

An Experimental Research on the Shear Friction Behavior of Beam-Column Joints of Partial Precast Concrete Structures (부분PC 보-기둥 접합부의 전단 마찰 거동에 관한 실험 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • An experimental program was initiated to investigate the structural capacity of PC (Precast Concrete) beam-column joints used for the underground parking structure. Static testing of 4 typical PC beam-column joints specimens was conducted. Specimens were designed to span a range of parameters typically encountered for such members, based on findings from the survey of existing PC joint details used in the construction fields in Korea. The specimens were four by their joint types and testing parameters. The specific structural behavior germane to each specimen, and general observations on overall member behavior as a function of the considered parameters, are reported. From the results of tests on four PC joints specimens, the beam-column joints of PC structure used for the underground parking building was found to have similar structural capacities when comparing to the cast-in-place concrete system.

Shear Capacity of Shear Reinforcement for Punching Shear in Flat Plate Structure (플랫 플레이트 구조에서 뚫림전단에 대한 전단보강체의 보강능력)

  • Kim, Jun-Seo;Choi, Hyun-Ki;Jin, Eon-Sik;Baek, Young-Soo;Choi, Chank-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.17-20
    • /
    • 2008
  • As a part of a research program to study the shear reinforcement of flat plate system, this investigation aimed to determine the effect of shear reinforcement type on punching shear strength of monolithic slab-column connection. A total of 5 specimens were fabrication and tested. The dimension of the slab were $2.63{\ast}2.725{\ast}0.18m$, with a centrally located column $0.6{\ast}0.8m$ in cross section. Experimental results showed that the CFS shear reinforcement was not effective because of lack of proper bond with concrete. 3 shear reinforcement except of CFS showed high effectiveness, which resulted in a considerable increment of the punching shear resistance of the connection.

  • PDF