• Title/Summary/Keyword: 2기준법

Search Result 2,869, Processing Time 0.03 seconds

의료보험GUIDE-보험약가 기준액표 개정

  • The Korean Dental Association
    • The Journal of the Korean dental association
    • /
    • v.29 no.2 s.261
    • /
    • pp.144-148
    • /
    • 1991
  • 보사부에서는 의료보험법 제35조 규정에 의한 진료수사기준중 "약가기준액표" 및 한방의료보험 진료수가 기준중 "한방의료보험 약가 기준액표"를 개정하고 관계기관에 이를 통보한 바 있습니다. 이에 협회에서는 치과진료에 관계된 약가기준액표만 발췌하여 게재하오니 많은 참고 있으시기를 바랍니다.

  • PDF

Design comparison of Fixed Offshore Structures Designed by WSD and LRFD Methods (허용응력설계법 및 하중저항계수설계법에 의한 고정식 해양구조물 설계결과 비교 )

  • Bae-Keun Jeong;Doo-Yong Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.42-49
    • /
    • 2023
  • When designing fixed jacket structures, overseas design standards are applied due to the absence of domestic design methods. Although the US API standards are mainly applied, API RP 2A suggests two design methods: the allowable stress design method (WSD) and the load resistance coefficient method (LRFD), and is applied according to the designer's judgment. In this study, the stress ratio of the two design methods was reviewed and compared using SACS, an analysis program dedicated to marine structures, for fixed marine structures actually installed on the domestic coast. As a result of the review, it was found that the LRFD design method showed a greater stress ratio for extreme load analysis and transportation analysis, and the WSD design method showed a greater stress ratio for loading and lifting. Therefore, when applying the design method, it is considered appropriate to select the final design method considering safety and economic feasibility after conducting an applicability review for the two design methods.

Three Dimensional Electric Field Analysis for 3-phase encapsulated Arrangement of GIS (3차원 전계해석법을 통한 초고압 GIS 상배치 구조에 관한 절연성능평가)

  • Yoon, J.H.;Jeong, S.Y.;Choi, J.W.;Kang, S.M.;Oh, I.S.;Im, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.60-62
    • /
    • 2003
  • 본 연구는, 초고압 GIS(Gas Insulated Switchgear)용 GCB(Gas Circuit Breaker)의 3상 배치구조를 설계 하기 위한 상간, 대지간의 절연성능을 평가하였다. 피임펄스 전압과 상용주파 전압인가시 상간, 대지간의 절연설계 기준과 비교하여 절연설계 안전율을 고려하여 설계에 적용하였다. 수치적 전계 해석법으로 3차원 전계 해석법과 2차원 축대칭 전계 해석법을 통해 전계 강도를 비교하였으며 3차원 전계 해석법으로는 경계 요소법(Boundary Element Method)을 사용하는 상용프로그램인 coulomb을 사용하였으며, 2차원 전계 해석법으로는 유한요소법(Finite Element Method)을 사용하는 Maxwell을 통해 절연성능 평가를 하였다. 마지막으로, 전계 해석을 통해 절연설계 기준에 적합한 상배치 구조 설계를 하였다.

  • PDF

Comparison of three different methods of measuring horizontal phoria and vertical phoria (검사방법에 따른 수평·수직사위량의 비교)

  • Kim, Hye-Dong;Kim, Dae-Nyoun;Park, Eun-Kyeu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2003
  • We did the comparison research about three different methods of measuring horizontal phoria and vertical phoria which are Von Graefe test, Maddox Rod test and polarizing lens test. The inspection was don with the subjective method of refraction about normal 63 subjects aged from 20 to 28 years old. The analysis of date resulted in as follows : 1. Using Von Graefe Horizontal phoria Measurement, they were measured 5% for orthpharia, 51% for exophoria and 44% for esophoria. 2. Using Von Graefe vertical phoria Measurement, they were measured 68% for orthphoria, 20% for left hypophoria against the right and 12% for left hyperphoria against the right. 3. Using Maddox Rod Horizontal phoria Measurement, they were measured 7% for orthphoria, 49% for exophoria and 44% for esophoria. 4. Using Maddox Rod vertical phoria Measurement, they were measured 70% for orthphoria, 19% for left hypophoria against the right and 11% for left hyperphoria against the right. 5. Using Polarizing Horizontal phoria Measurement, they were measured 10% for orthphoria, 49% for exophoria and 41% for esophoria. 6. Using Polarizing vertical phoria Measurement, they were measured 92% for orthpharia, 5% for left hypophoria against the right and 3% for left hyperphoria against the right.

  • PDF

포장과 법률 - "자율안전확인대상공산품의안전기준" 개정고시

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.237
    • /
    • pp.106-130
    • /
    • 2013
  • 기술표준원은 "품질경영 및 공산품안전관리법" 제19조(자율안전확인대상공산품의 신고 등) 제2항 및 같은법 시행규칙 제2조 제2항의 규정에 의한 자율안전확인대상공산품 안전기준을 개정 고시했다. 본 고에서는 개정 취지 및 주요개정, 자율안전확인대상 공산품별 안전기준 신 구 조문을 비교해 살펴본다.

  • PDF

A Study on the PRC Generation Algorithms for Virtual Reference Stations Using a Network of DGNSS Reference Stations (DGNSS 기준국 네트워크를 활용한 가상기준국 보정정보 생성 알고리즘에 관한 연구)

  • Kim, Hye-In;Park, Kwan-Dong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.221-228
    • /
    • 2011
  • For service-area-widening and commercialization of DGNSS service, Ministry of Land, Transport and Maritime Affairs is developing a DGNSS service based on VRS using T-DMB. In this study, three PRC generation algorithms are developed for VRS DGNSS and their accuracies were evaluated. Three DGNSS correction generation algorithms are based on inverse distance weighting, 1st- and 2nd- multiple linear regression, and their positioning accuracies were compared in terms of the number of reference stations used for network composition and the algorithm type. As a result, the positioning accuracy of the case of using 16 sites is better than that of 6 sites. And the algorithm using the multiple linear regression showed the best performance. When the positioning accuracy of VRS DGNSS was compared with the traditional single-reference DGNSS, the improvement ratio was 20-23% and 20-36% for the horizontal and vertical directions, respectively.

포장과 법률 - 유해화학물질 제조·사용시설 설치 및 관리에 관한 고시

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.318
    • /
    • pp.102-110
    • /
    • 2019
  • 환경부 소속 화학물질안전원은 화학물질관리법(이하 화관법)이 일부 개정됨에 따라 유해화학물질 취급시설의 설치 및 관리에 필요한 세부사항에 관한 규정을 제정했다. 총 14조, 부칙 2조, 별표 1종으로 구성된 이번 고시는 취급시설의 기술기준과 세부기준이 포함되어 있다. 다음에 '유해화학물질 제조 사용시설 설치 및 관리에 관한 고시'의 상세한 내용을 살펴보도록 한다.

  • PDF

A Study on Industrial Site Annexed Parking Unit Calculation Method by Considering Facility Use and Scale Characteristics (용도 및 규모특성을 고려한 산업단지 공장시설의 부설주차장 설치기준 개선방안 연구)

  • Ahn, Woo-Young;Lee, Seon-Ha
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2010
  • The present annexed parking lot standards for buildings in Parking Act are categorized in 9 groups in terms of recreation, culture and assembly, housing, factory, and so on, in which same grouped facilities have uniform parking standards. The local governments have authority to itemize groups and adjust parking standards within ${\pm}50%$ ranges. These days diversity in building types and functions need more fractionated parking standards; however, most local governments focusing merely on applying strengthened parking standards in general without systematic rules of consistency. The current problem of parking standards being used is lack of regarding facility characteristics; expecially, a large sized high-tech manufacturing facility located in industrial site is still applied by same parking standards as normal manufacturing facility, even though most part of manufacturing process is automated and hence less manpower is employed. This paper presents a systematic method of analyzing parking generation unit for factory facilities in industrial site in terms of facility use and scale characteristics.

미약무선국의 3미터 전계강도 기준값에 관한 연구

  • 박승근;손흥민
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.70-77
    • /
    • 1997
  • 최근 전파통신 기술의 급속한 발전과 경제적 수준의 향상에 따라 다양한 무선국에 대한 수요가 증가한고 있는 가운데 미약한 전력의 전파를 발사하는 미약무선국은 무선국 개설시 허가나 신고가 필요없는 무선국으로 산업활동과 일상생활 속에서 좁은 서비스 반경을 가지고 음성 및 데이터 전송용, 장비의 원격제어용 등의 용도로 사용범위가 확산되어가고 있는 추세이다. 미약무선국의 폭넓은 활용은 국내 전파산업의 육성과 국민의 사회적 활동 및 일상생활의 편의도모등, 많은 긍정적인 효과를 가지고 있지만 무분별한 미약무선국의 사용으로 인한 전파발사는 무선국의 상호간에 간섭을 일으켜 통신품질을 현저히 낮게 하거나 통신자체를 불가능하게 만드는 등 심각한 부작용을 초래할 수 있다. 그러므로 각 국은 미약무선국의 발사 전파로 인한 간섭으로부터 기존의 무선국을 보호하고 한정된 주파수 자원을 효과적으로 사용하여 관련 전파산업의 건전한 발전과 육성을 도모할 목적으로 미약무선국의 사용 주파수와 그에 따른 발사전파의 출력을 제한하는 관련 전파법규를 가지고 있다. 국내의 경우는 전파법 시행령 제56조 2항 1호에 측전거리 3미터를 기준으로 사용 주파수 대별로 전계강도 기준값이 설정되어 있고 2호에는 500미터 전계강도 기준값이 규정되어 있는데, 본 글에서는 전파법 시행법 제 56조 2항 1호와 2호에 해당하는 무선국을 미약무선국이라고 정의한다.

  • PDF

태양열주택의 기준

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.10 s.211
    • /
    • pp.74-75
    • /
    • 1986
  • 건축법시행령 제101조 제1항 2호 및 동시행규칙 제34조의 2의 규정이 의하여 태양열주택의 기준을 별첨과 같이 고시하였으니 업무에 참고하시기 바랍니다.

  • PDF