• Title/Summary/Keyword: 1MS/s

Search Result 2,196, Processing Time 0.028 seconds

A 10-bit 40-MS/s Low-Power CMOS Pipelined A/D Converter Design (10-bit 40-MS/s 저전력 CMOS 파이프라인 A/D 변환기 설계)

  • Lee, Sea-Young;Yu, Sang-Dae
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • In this paper, the design of a 10-bit 40-MS/s pipelined A/D converter is implemented to achieve low static power dissipation of 70 mW at the ${\pm}2.5\;V$ or +5 V power supply environment for high speed applications. A 1.5 b/stage pipeline architecture in the proposed ADC is used to allow large correction range for comparator offset and perform the fast interstage signal processing. According to necessity of high-performance op amps for design of the ADC, the new op amp with gain boosting based on a typical folded-cascode architecture is designed by using SAPICE that is an automatic design tool of op amps based on circuit simulation. A dynamic comparator with a capacitive reference voltage divider that consumes nearly no static power for this low power ADC was adopted. The ADC implemented using a $1.0{\mu}m$ n-well CMOS technology exhibits a DNL of ${\pm}0.6$ LSB, INL of +1/-0.75 LSB and SNDR of 56.3 dB for 9.97 MHz input while sampling at 40 MHz.

  • PDF

Simplified 2-Dimensional Scaled Min-Sum Algorithm for LDPC Decoder

  • Cho, Keol;Lee, Wang-Heon;Chung, Ki-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1262-1270
    • /
    • 2017
  • Among various decoding algorithms of low-density parity-check (LDPC) codes, the min-sum (MS) algorithm and its modified algorithms are widely adopted because of their computational simplicity compared to the sum-product (SP) algorithm with slight loss of decoding performance. In the MS algorithm, the magnitude of the output message from a check node (CN) processing unit is decided by either the smallest or the next smallest input message which are denoted as min1 and min2, respectively. It has been shown that multiplying a scaling factor to the output of CN message will improve the decoding performance. Further, Zhong et al. have shown that multiplying different scaling factors (called a 2-dimensional scaling) to min1 and min2 much increases the performance of the LDPC decoder. In this paper, the simplified 2-dimensional scaled (S2DS) MS algorithm is proposed. In the proposed algorithm, we figure out a pair of the most efficient scaling factors which multiplications can be replaced with combinations of addition and shift operations. Furthermore, one scaling operation is approximated by the difference between min1 and min2. The simulation results show that S2DS achieves the error correcting performance which is close to or outperforms the SP algorithm regardless of coding rates, and its computational complexity is the lowest comparing to modified versions of MS algorithms.

Methane Emission, Nutrient Digestibility, Energy Metabolism and Blood Metabolites in Dairy Cows Fed Silages with and without Galacto-oligosaccharides Supplementation

  • Santoso, B.;Kume, S.;Nonaka, K.;Kimura, K.;Mizukoshi, H.;Gamo, Y.;Takahashi, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.4
    • /
    • pp.534-540
    • /
    • 2003
  • This study was conducted to investigate the effect of supplementation of galacto-oligosaccharides (GOS) on methane emission, nutrient digestibility, energy utilization and blood metabolites by Holstein cows fed silages. In two sequential digestion and respiratory trials, two non-lactating Holstein cows were arranged to a balanced incomplete block design. Experimental diets consisted of two silage types; orchardgrass (Dactylis glomerata L.) based silage (OS), mixed silage (orchardgrass based silage and alfalfa (Medicago sativa L.) silage) (MS), while two GOS levels were without supplementation (0) and 2% of dry matter intake supplementation (2). Four combination diets were OS-0, OS-2, MS-0 and MS-2. Significant effects of silage types and GOS supplementation levels were not observed for DM and OM intake. Whereas the digestibility of OM, NDF and ADF was significantly (p<0.05) higher in cows fed OS with and without GOS compared cows fed MS diets. As percentage of GE intake, fecal energy loss for OS diets was significantly (p<0.05) declined than for MS diets. In contrast, cows fed MS diets had lower (p<0.05) urine energy loss as a proportion of GE intake compared to OS diets. Energy loss as CH4 and heat production was numerically increased when cows fed both OS and MS with GOS supplementation. Compared to OS, CH4 emission in cows fed MS was numerically decreased by 10.8 %. Methane conversion ratio (energy loss as CH4 per unit of GE intake) for OS-0, OS-2, MS-0 and MS-2 were 7.1, 7.2, 6.8 and 7.0, respectively. Plasma of glucose and urea-N concentration were significantly (p<0.05) elevated from 1 h to 6 h after feeding, otherwise total protein in plasma was declined (p<0.01) at 6 after feeding.

Analysis of Heterocyclic Amines in Mainstream Cigarette Smoke using by LC-MS/MS (LC-MS/MS를 이용한 담배 연기 중 Heterocyclic Amines의 분석)

  • Kim, Ick-Joong;Jang, Gi-Chul;Ji, Sang-Un;Min, Hye-Jeong;Kim, Hyo-Keun;Hwang, Geon-Jung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • This study was carried out to determine the analytical methods for heterocyclic amines(HAs) of the tobacco smoke by LC/MS/MS. HAs have been found in pyrolysate of protein and cooked food including protein, were known the Sugimura compound. HAs content of the smoke were known to exist very low ppb level. Especially, some of HAs are mutagenic and carcinogenic compounds. In according to IARC, the toxicity of N-heterocyclic amines classified IARC class 2A or 2B group. Precursors of these compounds are glutamic acid, protein and free amino acids including tryptophan, therefore, the precursors have been proved in cooked food continuously. This study was investigate multiple analysis methods for HAs and HAs contents of some commercial products. In this study, we used the linear type smoking machine for HAs analysis. At the ISO conditions, mainstream smoke was collected on cambridge filter pad, and then cambridge filter pad was extracted by 0.1% acetic acid. The extracted solution were passed cation exchange SPE cartridge to remove matrix, samples were analyzed using LC/MS/MS on MRM mode. From the result that optimized this methods, the correlation coefficient(R) of the individual compounds were good linearity over 0.999, recovery rate over 96% and the limit of detection were good values between 0.06 to 0.37 ng/mL, In addition, HAs content of some commercial products were in range of 0.02 to 43.8 ng/cig.

Determination of 8-iso-PGF as Oxidative Stress Marker in Human Urine by High Performance Liquid Chromatography with Tandem Mass Spectrometry (LC/MS/MS를 이용한 산화성 스트레스 지표로써 소변 중 8-iso-PGF 분석)

  • Kho, Young-Lim;Lee, Eun-Hee;Chae, Hong-Jae;Choi, Kyung-Ho;Paik, Do-Myung
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.44-51
    • /
    • 2010
  • This study aimed to develop analytical method for 8-isoprostanes as biomarkers for oxidative stress with LC/MS/MS technique and to apply the method for human urine samples. Analyzed compounds for urinary oxidative stress markers were 7 stereo-isomers of prostaglandins and the internal standard (iso-$PGF_{2{\alpha}}-d_4$) was used to adjust the recovery rate. The method for determining urinary iso-$PGF_{2{\alpha}}$ consisted of solid phase extraction and LC/MS/MS detection. Separation of isomers of prostaglandins completed by porous graphitic carbon column and buffer solution. Detection limits for urinary markers of oxidative stress, iso-$PGF_{2{\alpha}}$ with LC/MS/MS were 0.01 ng/ml by S/N ratio 3 and 0.028 ng/ml by calculated as to FDA method. The recovery (92.8~101.9%) and precision (8.8~20.7%) of analysis were feasible for detecting iso-$PGF_{2{\alpha}}$ in real human urine samples. We detected 4 isomers of prostaglandins in human urine samples. Mean (standard deviation) of urinary iso-$PGF_{2{\alpha}}$ concentration were 0.231 (0.117) ng/mg creatinine for smoking group and 0.154 (0.082) ng/mg creatinine for non-smoking group.

Cadmium Tolerance in Alfalfa is Related to the Up-regulation of Iron and Sulfur Transporter Genes along with Phytochelatin Accumulation

  • Lee, Ki-Won;Lee, Sang-Hoon;Song, Yowook;Ji, Hee Jung;Choi, Bo Ram;Lim, Eun A;Rahman, Md Atikur
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.3
    • /
    • pp.190-195
    • /
    • 2020
  • Cadmium (Cd) toxicity is a serious limitation for agricultural production. In this study, we explored tolerance mechanism associated with Cd toxicity tolerance in alfalfa plants. We used three distinct alfalfa cultivars M. sativa cv. Vernal, M. sativa cv. Zhung Mu, and M. sativa cv. Xing Jiang Daye in this study. Cd showed declined chlorophyll score in Xing Jiang Daye compared with Zhung Mu and Vernal. No significant change observed among the cultivars for root and shoot length. Atomic absorption spectroscopy analysis demonstrated a significant accumulation of Cd, Fe, S and PC in distinct alfalfa cultivars. However, Zhung Mu and Xing Jiang Daye declined Cd accumulation in root, where Fe, S and PC incremented only in Zhung Mu. It suggests that excess Cd in Zhung Mu possibly inhibited in root by the increased accumulation of Fe, S and PC. This was further confirmed by the response of Fe (MsIRT1) and S transporters (MsSULTR1;2 and MsSULTR1;3), and MsPCS1 genes associated with Fe, S and PC availability and translocation in roots and shoots. It suggests that specially the transcript signal inducing the responses to adjust Cd especially in Zhung Mu. This finding provides the essential background for further molecular breeding program for forage crops.

Two-year Quaternary Isolation of Gram-positive Bacilli Using MALDI-TOF MS in Positive Blood Culture of a University Hospital (일개 대학병원의 혈액배양에서 MALDI-TOF MS를 이용한 Gram-positive Bacilli의 2년간 분기별 분리율)

  • Choi, Jin-Un;Yu, Young-Bin;Kim, Sang-Ha;Won, Seungho;Kim, Young-Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.414-421
    • /
    • 2018
  • In this study, Gram-positive bacilli (GPB) were identified by MALDI-TOF MS and analyzed according to the quaternary and microbial strains in the blood culture medium over a two year period at a university hospital. The results were as follows. The overall positive rate of blood culture was 9.97%. In 713 isolated GPB, 410 strains (57.5%) were identified using a microflex MALDI Biotyper. The positive rate of GPB among the blood culture positive bacteria was 8.2%, and the quarterly isolation rate was 9.8% in the third quarter of 2015, 8.7% in the second quarter of 2016, 8.1% in the third quarter of 2016, 8.1% in the first quarter of 2015, 7.9% in the first quarter of 2015, 7.9% in the second quarter of 2015, 6.8% in the first quarter of 2016, and 6.7% in the fourth quarter of 2015. The isolates were Corynebacterium striatum 89 (12.4%), Bacillus cereus 60 (8.4%), Bacillus subtilis 30 (4.2%), Paenibacillus urinalis 29 (4.1%), and Listeria monocytogenes 25 (3.5%). The results of 16S rRNA sequencing of 43 isolates (86.0%) were consistent with those of the other 50 isolates. Five out of the seven unmatched weeks were not identified by MALDI-TOF MS.

Respiratory Depression during Oral MS-Contin Administration for Pain Management of Gall Bladder Cancer (말기 담낭암 환자의 통증조절을 위해 MS Contin 투여중 발생한 호흡억제 -증례 보고-)

  • Lee, Chul-Woo;Lee, Byung-Ho;Lee, Yong-Hee
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.239-243
    • /
    • 1996
  • MS-Contin is an oral controlled-release preparation of morphine sulfate that has been used widely in the management of advanced cancer pain. It prolongs plasma concentration of morphine with no observable accumulation properties following repeated dosing, thereby promoting uninterrupted sleep and hopefully improving patient's quality of life. The common side effects of MS Contin are nausea, vomiting, drowsiness and constipation. But these symptoms are usually mild and respiratory depression is a rare problem. We experienced respiratory depression during oral administration of MS contin for the pain management of advanced gall bladder cancer of 76 years old male patient with metastasis at liver, intestine and cervical lymph node. After we increased the dosage of MS Contin from 160mg to 220mg per day, due to abdominal pain, we observed morphine reaction of MS Contin overdose such as pinpoint pupil, deeply slow respiration below 8/minute, and drowsiness. After intravenous bolus injection of 0.4 mg naloxone followed by continuous administration of 0.2 mg/hr for 4 hours, the patient regained consciousness. The administered route of morphine was changed to intravenous PCA (patient controlled analgesia). There was no aspiration sign as confirmed by chest x-ray. The patient was comfortable and delayed no signs of respiratory depression until now.

  • PDF

An Experimental Study on Construction Efficiency of High-Frequency Arc Metal Spray Machine (고주파 아크 금속용사 장치의 시공성능 평가에 관한 실험적 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.6
    • /
    • pp.481-488
    • /
    • 2020
  • The arc thermal metal spraying method (ATMSM) has been used in Korea to improve the electromagnetic pulse (EMP) shielding effect of building and infrastructure by three machines of MS, KMS and HMS (Metal Spray, Korea Metal Spray, High-frequency Meta Spray). The adhesion ability of sprayed metal was found to be 58.32, 64.66 and 87.62% for MS, KMS and HMS, respectively. The metal sprayed area per hour of MS, KMS and HMS was calculated and found to be 14.3, 19.25 and 22.16㎡/h, respectively. The HMS showed the highest metal spray area attributed to the diameter of metal wire i.e. 1.6mm which sprayed 80 mm with 18 m/min. There was minimum loss of metal and the highest efficiency by HMS compared to others. Therefore, it is suggested to use HMS for metal spraying by ATMSM to enhance the EMP shielding effect.

Change of MS Method and Comparison of SIFT-MS Method

  • CHOI, Jong-Sun;KWON, Lee-Seung;LEE, Ji-Hoon;KIM, Romertta;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.1
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: This study examines the history of the evolution of MS analysis and intends to consider the future direction of technological development through the difference from the latest technology, SIFT-MS. Research design, data and methodology: A method of analysis will be described in detail at the below by SIFT-MS (Selected Ion Flow Mass Spectrometry), which is a technology developed by a company called SIFT Technologies. Results: The initial concept of mass spectrometry was begun in the late 1890s, and it continues to evolve even after the 21st century through the ripening stage of the 20th century. The development process of mass spectrometry by year has been described in detail in the Main text. Conclusions: Mass spectrometry, qualitative and quantitative analysis of substances plays a very important role in the research and medical fields. The development of these analytical methods is expected to continue in the future, and faster and more accurate qualitative analysis and mass spectrometry will be developed than the level currently reached. In addition, it is expected that hardware and software will be configured so that non-analysis experts can handle it easily, and it will be used as a technology that is more closely related to our lives.