Long-term Runoff Simulation Considering Water for Agricultural Use in Geum River Basin (농업용수 이용량을 고려한 금강유역 장기유출모의)

  • Woo, Dong-Hyeon;Lee, Sang-Jin;Kim, Joo-Cheol;An, Jung-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.3
    • /
    • pp.349-355
    • /
    • 2010
  • This study aims at the augmentation of reliability of the long-term rainfall runoff model. To do so agricultural water uses are evaluated by analyzing the effects of small scale irrigational hydraulic structures on long term runoff processes and thereby rainfall-runoff model is modified considering them. As a result the simulation results of the sub-basins having more agricultural reservoirs than the others are disagreed with the observations. The 2nd quarter simulation results show similar trend to it. Especially the farming seasonal results of the drought year as the year of 2008 have many negative discharge values due to the lack of agricultural water uses. This result come from the water uses input data corresponding to not real water uses but water demands. In this study the formulas are derived to estimate the discharges and return ratios and the long term rainfall-runoff model is reformulated based on these. It is confirmed that the errors of the simulation results could be reduced by considering the effects of small scale irrigational hydraulic structures and the reliability of the simulation results improved greatly.

Development and performance test of a liquid nitrogen circulation pump for HTS power cable

  • Seok, Jihoon;Kim, Dongmin;Lee, Changhyeong;Kim, Manryeol;Choi, Jeongdong;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.3
    • /
    • pp.28-33
    • /
    • 2018
  • With the continuous performance improvement and commercialization of HTS wires, there have been many efforts to commercialize HTS power cables recently. Unlike conventional power cables, a cryogenic cooling system is required for a HTS power cable and a cryogenic pump is one of the essential components to circulate subcooled liquid nitrogen and cool the HTS power cable. Especially, the development of a reliable and high-efficiency cryogenic pump is an important issue for the commercialization of HTS power cables of several kilometers or more. In this study, we designed and fabricated a cryogenic pump for subcooled liquid nitrogen with a mass flow rate of 1.2 kg/s, a differential pressure of 5 bar, and evaluated the hydraulic performance of the pump. Impeller design was conducted to meet the target design performance with 1 D analysis model and CFD analysis. The pump performance parameters such as pressure heads, mass flow rates, and efficiencies in accordance with rotating speeds were assessed using a laboratory's performance evaluation system.

Hydraulic Modal Analysis of High-Pressure Common-rail Fuel Injection System for Passenger Vehicle (승용 CR 연료분사시스템에 대한 유압 Modal 분석)

  • Sung, Gisu;Kim, Sangmyeong;Kim, Jinsu;Lee, Jinwook
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, R&D demand for environmental friendly vehicle has rapidly increased due to its global environmental issues such as global warming, energy and economic crisis. Under this situation, the most realistic alternative way for environmental friendly vehicle is a clean diesel vehicle. The common-rail fuel injection system, as key technology of clean diesel vehicle, consists of a high pressure pump, common-rail, high pressure fuel line and electronic control injector. In common-rail high-pressure fuel injection system, high pressure wave of injection system and geometry of injector elements have a major effects on high-pressure fuel spray. Therefore, in this study, the numerical model was developed for analysis about the common-rail fuel pressure pulsation by using AMESim code. We could secure stability of common-rail high-pressure fuel injection system through optimal design of fuel line.

Efficiency of Marine Hydropower Farms Consisting of MultipleVertical Axis Cross-Flow Turbines

  • Georgescu, Andrei-Mugur;Georgescu, Sanda-Carmen;Cosoiu, Costin Ioan;Alboiu, Nicolae
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.150-160
    • /
    • 2011
  • This study focuses on the Achard turbine, a vertical axis, cross-flow, marine current turbine module. Similar modules can be superposed to form towers. A marine or river hydropower farm consists of a cluster of barges, each gathering several parallel rows of towers, running in stabilized current. Two-dimensional numerical modelling is performed in a horizontal cross-section of all towers, using FLUENT and COMSOL Multiphysics. Numerical models validation with experimental results is performed through the velocity distribution, depicted by Acoustic Doppler Velocimetry, in the wake of the middle turbine within a farm model. As long as the numerical flow in the wake fits the experiments, the numerical results for the power coefficient (turbine efficiency) are trustworthy. The overall farm efficiency, with respect to the spatial arrangement of the towers, was depicted by 2D modelling of the unsteady flow inside the farm, using COMSOL Multiphysics. Rows of overlapping parallel towers ensure the increase of global efficiency of the farm.

Research on estimating roughness coefficient for 1-D hydraulic model using river flow measurement data and water surface slope (실측자료와 수면경사를 활용한 1차원 수리모형의 조도계수 산정 연구)

  • Seong Jun Kim;Chang Sung Kim;Geunsoo Son;Sunghyun Kwak;;;Hong Koo Yeo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.290-290
    • /
    • 2023
  • 하천의 조도계수는 하천의 수리특성을 나타내는 대표적인 지표로써 수리모형의 모의를 수행하는데 중요한 매개변수 중 하나이다. 하지만 현재 수리모형의 조도계수는 하천정비기본계획시에 수립된 하나의 조도계수를 사용하여 모의를 수행하고 있어 유량 또는 수위에 따라 동일한 조도계수를 적용하게 되면 수위를 과대 또는 과소 모의 할 수 있는 문제가 있다. 따라서 다양한 유량 조건에 따른 모의결과의 신뢰성을 확보하기 위해서는 유량 규모에 따른 조도계수를 산정하여 검토할 필요가 있다. 이에 본 연구는 삼례교를 대상으로 하였으며, 실측된 유량자료를 활용하여 유량 또는 수위에 따른 조도계수를 산정하였고 HEC-RAS 모의 결과와 비교하였다. 분석결과, 삼례교 지점의 경우 일반적으로 수위가 증가할 수록 조도계수가 감소하다가 일정한 경향을 보이는 것과 상이하게 수위가 증가할수록 조도계수가 증가하는 경향을 보였다. 이는 하천 내에 관목이 형성되어있어 조도계수가 증가한 것으로 판단된다. 추후, 다양한 지점을 대상으로 분석을 통해 환경부 등 하천 관련 사업과 하천기본계획 수립 시 조도계수 표준화를 통한 합리적 설계에 기여할 수 있을 것으로 기대된다.

  • PDF

Assessing the Influence Radius of a Water Treatment System Installed in a Reservoir Using Tracer Experiment and 3D Numerical Simulation (추적자 실험 및 3차원 수치모의를 이용한 저수지 수처리 장치의 영향반경 평가)

  • Park, Hyung Seok;Lee, Eun Ju;Ji, Hyun Seo;Choi, Sun Hwa;Chun, Se Woong
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.3-12
    • /
    • 2018
  • The objective of this study was to evaluate the radius of influence of effluent of water treatment system developed for the purpose of improvement of reservoir water quality using fluorescent dye (Rhodamine-WT) tracer experiment and 3-D numerical model. The tracer experiment was carried out in a medium-sized agricultural reservoir with a storage capacity of $227,000m^3$ and an average depth of 1.6 m. A guideline with a total length of 160 m was installed at intervals of 10 m in the horizontal direction from the discharge part, and a Rhodamine measurement sensor (YSI 6130, measurement range $0-200{\mu}g/L$) was used to measure concentration changes in time, distance, and depth. Experimental design was established in advance through Jet theory and the diffusion process was simulated using ELCOM, a three dimensional hydraulic dynamics model. As a result of the study, the direct effect radius of the jet emitted from the applied water treatment system was about 50-70 m, and the radius of physical effect by the advection diffusion was judged to be 100-120 m. The numerical simulations of effluent advection-diffusion of the water treatment system using ELCOM showed very similar results to those of the impact radius analysis using the tracer experiment and jet flow empirical equations. The results provide valuable information on the spatial extent of the water quality improvement devices installed in the reservoir and the facility layout design.

Development of a Moving Body Type Wave Power Generator using Wave Horizontal Motions and Hydraulic Experiment for Electric Power Production (파의 수평운동을 이용한 가동물체형 파력발전장치의 개발과 전력생산에 관한 수리실험)

  • Hwang, Seong Su;Lee, Dong Soo;Yang, Kyong Uk;Byun, Jung Hwan;Park, Il Heum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.2
    • /
    • pp.73-80
    • /
    • 2016
  • To reduce the mechanical energy loss and to get the high energy efficiency, an apparatus of wave power generation inducing a consistent one way rotating motion from the wave reciprocation motions was developed and the hydraulic experiments for the real electric power production were conducted and the results were discussed. In the experiments for the shape of the buoyant tank, the efficiency of the fixed 9 cm diameter type enduring the wave plate weight was 14.6% and this was the best result for all shapes. But although the free sliding type was expected to represent a high efficiency, the experiments did not show a good result as 8.5% efficiency. Therefore, the shape of buoyant tank was decided as the fixed 9 cm diameter type in the next all tests. In the experiments for the various incident waves, when the water depth was 90 cm, the average efficiencies were measured as 3.9% in the 2nd gear, 4.9% in the 3rd gear, 4.9% in the 4th gear, 12.0% in the 5th gear, 10.0% in the 6th gear, 3.1% in the 7th gear, and 3.0% in the 8th gear. Also, when the water depth was 80 cm, the average efficiency was shown as 15.0% with 5th gear condition. Therefore the high average efficiency as 13.5% was given with 80~90 cm water depth and the 5th gear in the model.

Analysis of Hydraulic effects on Piers and Transverse Overflow Type Structures in Urban Stream (도시하천의 교각 및 횡단 월류형 구조물에 의한 수리영향 분석)

  • Yoon, Sun-Kwon;Chun, Si-Young;Kim, Jong-Suk;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.197-212
    • /
    • 2008
  • Recently, stream flow analysis has been accomplished by one or two dimensional equations and was applied by simple momentum equations and fixed energy conservations which contain many condition limits. In this study, FLOW-3D using CFD (Computational Fluid Dynamics) was applied to stream flow analysis which can solve three dimensional RANS (Reynolds Averaged Navier-Stokes Equation) control equation to find out physical behaviors and the effect of hydraulic structures. Numerical simulation accomplished those results was compared by using turbulence models such as ${\kappa}-{\varepsilon}$, RNG (Renormalized Group) ${\kappa}-{\varepsilon}$ and LES (Large Eddy Simulation). Numerical analysis results have been illustrated by the turbulence energy effects, velocity of flow, water level pressure and eddy flows around the piers and transverse overflow type structures. These results will be able to used by basis data that catch hold of effects on long-term bed elevation changes, sediment accumulations, scours and water aggravations by removal of obsolete transverse over flow type structures in urban stream.

An Analysis of Groundwater Flow at Bugok Area Using MODFLOW (MODFLOW 모형을 이용한 부곡온천지역 지하수 유동해석)

  • Chung, Sang-Ok;Lee, Young-Dae;Min, Byung-Hyung
    • Water for future
    • /
    • v.27 no.1
    • /
    • pp.79-88
    • /
    • 1994
  • This study was conducted to analyse groundwater flow in the Bugok hot spring area using the MODFLOW model which can simulate three dimensional groundwater flow both in confined and unconfined aquifers. Based on this study the following conclusions were obtained: 1) The hydraulic conductivity and the specific storage of the aquifer were 0.0135 m/day and 0.020, respectively, and the model-predicted groundwater elevation agreed well with the observed one. 2) Simulation results showed that the groundwater level declines at the end of the one-year simulation period when the annual recharge rate is small and the annual pumping rate high, which is the worst combination. Except that combination, the groundwater level does not decline at the end of one-year simulation period indication the pumping rates used were allowable. 3) The safe yield depends upon the magnitudes of the recharge and pumping rates. The pumping rate should not produce excess decline of groundwater level around April when the water level is the lowest in a year.

  • PDF

Modeling the effects of excess water on soybean growth in converted paddy field in Japan 1. Predicting groundwater level and soil moisture condition - The case of Biwa lake reclamation area

  • Kato, Chihiro;Nakano, Satoshi;Endo, Akira;Sasaki, Choichi;Shiraiwa, Tatsuhiko
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.315-315
    • /
    • 2017
  • In Japan, more than 80 % of soybean growing area is converted fields and excess water is one of the major problems in soybean production. For example, recent study (Yoshifuji et al., 2016) suggested that in the fields of shallow groundwater level (GWL) (< 1m depth), rising GWL even in a short period (e.g. 1 day) causes inhibition of soybean growth. Thus it becomes more and more important to predict GWL and soil moisture in detail. In addition to conventional surface drainage and underdrain, FOEAS (Farm Oriented Enhancing Aquatic System), which is expected to control GWL in fields adequately, has been developed recently. In this study we attempted to predict GWL and soil moisture condition at the converted field with FOEAS in Biwa lake reclamation area, Shiga prefecture, near the center of the main island of Japan. Two dimensional HYDRUS model (Simuinek et al., 1999) based on common Richards' equation, was used for the calculation of soil water movement. The calculation domain was considered to be 10 and 5 meter in horizontal and vertical direction, respectively, with two layers, i.e. 20cm-thick of plowed layer and underlying subsoil layer. The center of main underdrain (10 cm in diameter) was assumed to be 5 meter from the both ends of the domain and 10-60cm depth from the surface in accordance with the field experiment. The hydraulic parameters of the soil was estimated with the digital soil map in "Soil information web viewer" and Agricultural soil-profile physical properties database, Japan (SolphyJ) (Kato and Nishimura, 2016). Hourly rainfall depth and daily potential evapo-transpiration rate data were given as the upper boundary condition (B.C.). For the bottom B.C., constant upward flux, which meant the inflow flux to the field from outside, was given. Seepage face condition was employed for the surrounding of the underdrain. Initial condition was employed as GWL=60cm. Then we compared the simulated and observed results of volumetric water content at depth of 15cm and GWL. While the model described the variation of GWL well, it tended to overestimate the soil moisture through the growing period. Judging from the field condition, and observed data of soil moisture and GWL, consideration of soil structure (e.g. cracks and clods) in determination of soil hydraulic parameters at the plowed layer may improve the simulation results of soil moisture.