• Title/Summary/Keyword: 125kHz

Search Result 118, Processing Time 0.034 seconds

A Study on Propagation Characteristics of Acoustic Signals in Indoor Environments (실내 음향신호 경로감쇠 모형 및 분석)

  • Jeong, Sang-Hyo;Lee, Eui-Hyoung;Yoo, Seung-Soo;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2C
    • /
    • pp.119-125
    • /
    • 2011
  • Start This paper analyzes the propagation characteristics of acoustic signals in indoor environments, which is applicable to indoor positioning system. Indoor stereo sound system is generally valid within $25m^2$. So it is not possible to apply prevalent sound propagation characteristic to indoor positioning system because the prevalent acoustic signals propagation characteristic is defined under free space condition. Therefore, in this paper, we present the propagation characteristics of acoustic signals in indoor environments considering the free space propagation characteristic as well as room characteristic such as humidity, temperature, absorption of atmosphere and so on. To verify the designed propagation model of indoor acoustic signals, this paper presents the propagation characteristics of decreasing sinusoidal signals whose frequencies ate from 1kHz to 20kHz in anechoic room. In addition, this paper also presents the propagation characteristics of decreasing sinusoidal signals which have multiple frequencies.

Resonance Characteristics of the Pears for Exporting for Optimum Packaging Design (적정 포장설계를 위한 수출용 배의 공진특성)

  • Park, Jong Min;Choi, Dong Soo;Hwang, Sung Wook;Jung, Hyun Mo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.125-130
    • /
    • 2019
  • Shock and vibration inputs are transmitted from the vehicle through the packaging to the fruit. Inside, these cause sustained bouncing of fruits against each other and container wall. These steady state vibration input may cause serous fruit injury, and this damage is particularly severe whenever the fruit inside the package is free to bounce, and is vibrated at its resonance frequency. The determination of the resonance frequencies of the fruit and vegetables may help the packaging designer to determine the proper packaging system providing adequate protection for the fruit, and to understand the complex interaction between the components of fruit when they relate to expected transportation vibration inputs. Instrumentation and technologies are described for determining the vibration response characteristics of the pears for exporting with frequency range from 10 to 200 Hz, sweep rate of 1 octave/min, sweep method of logarithmic up and down and acceleration levels of 0.2, 0.4, 0.6, 0.8 and 1.0 G considering the domestic transportation environment. The resonance frequency of the pears ranged from 49.04 to 87.16 Hz and the amplitude at resonance was between 0.96 and 4.02 G in test frequency band and acceleration level. The resonance frequency and amplitude at resonance frequency band of the pears decreased with the increase of the sample mass. The multiple nonlinear regression equations for predicting the resonance frequency of the pears were developed using the independent variables such as mass, input acceleration.

Structure and Electrical Properties of Pb($Zn_{1/3}Nb_{2/3})O_3-Pb(Zr_xTi{1-x})O_3$ Ceramics (Pb($Zn_{1/3}Nb_{2/3})O_3-Pb(Zr_xTi{1-x})O_3$세라믹의 구조적, 전기적 특성)

  • 조현무;이성갑;이영희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.357-360
    • /
    • 2000
  • Ferroelectric 0.05PZN-xPZT(90/10)-(0.95-x)PZT(10/90) (x=0.65, 0.85) specimens were fabricated by the mixed-oxide method and cold-pressing method using sol-gel derived PZT(90/10) and PZT(10/90) powders. All specimens show a uniform ferroelectric grain without the presence of the pyrocholre phase. Average grain size increased with an increase in sintering temperature, the value for the x=0.65 specimen sintered at 125$0^{\circ}C$ was 14.4${\mu}{\textrm}{m}$. The dielectric constant and dielectric loss of the x=0.65 specimen sintered at 125$0^{\circ}C$ were 1247, 2.05%, respectively. All specimens showed fairly good temperature and frequency stability of dielectric constant with the range from -2$0^{\circ}C$ to 6$0^{\circ}C$ and 100Hz to 10MHz. The coercive electric field and the remanent polarization of x = 0.65 specimen sintered at 125$0^{\circ}C$ were 8.5 kV/cm and 13 $\mu$C/cm$^2$, respectively.

  • PDF

Field Analysis in the Ferrite Core at 100 kHz Band Magnetic Field (100 kHz 대역의 자계 환경내(內)에서의 페라이트 코어의 계(界) 해석)

  • Koo, Bon-Chul;Yoo, Jae-Sung;Kim, Mi-Ja;Gimm, Yoon-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.977-983
    • /
    • 2007
  • Recently, the number of systems which utilize wireless power transmission to a receiving module in a short distance is increasing. For efficient use of receiving space, coils are wound around the ferrite core to produce electromotive force(emf) in suppling power by wireless transmission. This paper analyzed the magnetic flux density distribution in the ferrite core in magnetic field environment which is uniformly oriented along to a single axis at 125kHz. For numerical analysis, Ansoft Maxwell which is applying the FEM(Finite Element Method) method was used. We studied the variations of the gathered magnetic fluxes to the changes of the relative permeabilities of the ferrite cores. Also we calculated the magnetic flux variation by shaving the ferrite core off for the groove of coil winding. Results showed that using a small ferrite core in magnetic field at 100kHz band can increase the amount of magnetic flux $3{\sim}4 times$ than without the core. The magnetic flux decreased 23% by shaving the core 0.5 mm on the periphery of 4.75 mm radius core with the relative permeability 800.

Estimating attenuation in methane hydrate bearing sediments from surface seismic data (메탄하이드레이트 부존층에서의 지진파 감쇠치 산출)

  • Lee, Kwang-Ho;Matsushima, Jun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.28-33
    • /
    • 2009
  • Methane hydrates are considered important in terms of their effect on global warming and as potential energy resources. Now, mainly the presence of a BSR and seismic velocity are used for estimation of methane hydrate concentration in the seismic reflection survey. But recent studies on seismic attenuation show that it can be used also to estimate methane hydrates concentration. In this study, we tried to estimate attenuation from 2D seismic reflection data acquired at Nankai Trough in Japan and analyzed attenuation properties in methane hydrate bearing sediments. Seismic attenuation estimated by QVO method in an offset range $125{\sim}1,575m$. We observed high attenuation in methane hydrate bearing sediments over BSR in a frequency range of 30-70Hz. Thus, this result demonstrates that seismic reflection wave within this frequency range are affected significantly by the existence of methane hydrate concentration zone.

  • PDF

Selection of Scale Model Materials for Acoustical Evaluation of 1:50 Multipurpose Halls (1:50 다목적홀의 음향평가를 위한 축소모형재료의 선정)

  • Jeon, Jin-Yong;Kim, Jeong-Jun;Kim, Yong-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.781-789
    • /
    • 2009
  • The absorption coefficients of the materials used in a 1:50 scale model multipurpose hall were measured based on ISO 354 and related laws. The shape and materials for the scale model were evaluated based on reflective surfaces, variable acoustic elements and sound-absorbing quality (125Hz-1kHz average) of seats. The measured average absorption coefficients of audience seats, audience and orchestra were 0.64, 0.74 and 0,45, respectively, which were simulated with the combination of wood, absorption materials and foam board. Various mounting methods for absorption curtain and banner were considered according to the installation methods. The average absorption coefficient was measured as 0.42, 0.47 and 0.45 in the conditions of Type A mounting, E mounting with 0.9 m backing air cavity, and Type G mounting which is suspended at the ceiling, respectively. It was confirmed that the absorption coefficient was increased at low frequency by backing air gap. The finishing material of stage house was an absorption material covered with thin fabric, which aimed average absorption coefficient of 0.68 by using fiber glass board. Each part of the real materials was compared with those of 1:50 scale model and it was found that the absorption characteristics of both cases were similar.

Structure and Pyroelectrical Properties of Pb($Zn_{1/3}Nb_{2/3}$)$O_3$-Pb($Zr_{x}Ti_{1-x}$)$O_3$Compound Ceramics (Pb($Zn_{1/3}Nb_{2/3}$)$O_3$-Pb($Zr_{x}Ti_{1-x}$)$O_3$ 세라믹의 구조적, 초전 특성)

  • 조현무;이성갑;이영희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.543-546
    • /
    • 2000
  • Ferroeleclric 0.05PZN-xPZT(90/10)-(0.95-x)PZT(10/90) (x=0.65, 0.85) specimens were fabricated by the mixed-oxide method and cold-pressing method using sol-gel derived PZT(90/10) and PZT(10/90) powders. All specimens show a uniform ferroelectric grain without the presence of the pyrocholre phase. Average grain size increased with an increase in sintering temperature, the value for the x=0.65 specimen sintered at 125$0^{\circ}C$ was 14.4$\mu$m. The dielectric constant and dielectric loss of the x=0.65 specimen sintered at 125$0^{\circ}C$ were 1247, 2.06%, respectively. All specimens showed fairly good temperature and frequency stability of dielectric constant with the range from -2$0^{\circ}C$ to 6$0^{\circ}C$ and 100Hz to 10MHz. The coercive field and the remanent polarization of x = 0.65 specimen sintered at 125$0^{\circ}C$ were 8.5 kV/cm and 13 $\mu$C/cm$^2$, respectively. The pyroelectric coefficient of the x=0.65 specimen sintered at 125$0^{\circ}C$ was 5.64$\times$10$^{-8}$ C/cm$^2$K, respectively.

  • PDF

Usefullness of Injection Laryngoplasty with Calcium Hydroxyapatite in Unilateral Vocal Cord Paralysis (일측 성대마비 환자에서 Calcium-Hydroxyapatite를 이용한 성대 주입술의 유용성)

  • Lee, Jae-Hoon;Kim, Sung-Won;Oh, Jung-Ho;Kim, Seung-Tae;Lee, Kang-Dae
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.119-125
    • /
    • 2011
  • Background and Objectives : Temporary or permanent vocal paralysis can be occurred after head and neck surgery such as thyroid cancer, esophageal resection, and chest operation including lung parenchymal resection, due to a vagus or recurrent laryngeal nerve injury. The authors aimed to determine the clinical efficacy of using Calcium-Hydroxyapatite (CaHA) for permanent unilateral vocal cord palsy patients. Materials and Method : Between July 2008 to July 2010, among patients with chief complain of hoarseness and aspiration, only who were diagnosed as unilateral vocal cord palsy under laryngoscopy, were selected. The patients included 3 females and 13 males age range between 29 to 79 and average age was 60 years old. Results : The hoarseness range were $8.94{\pm}0.77$, $4.63{\pm}1.02$, $4.31{\pm}1.30$ statistically showing significant postoperative improve at preoperative, 1 week and 3 months. Also aspiration were $7.44{\pm}2.48$, $3.63{\pm}1.82$, $3.19{\pm}1.91$ statistically improved during the same period. The result of voice analysis showed that the frequency range shows decrease at 1 week and 3 months after the injection compared to that of the preoperative result in both male and female group (Male: $161.63{\pm}32.78$ Hz, $139.13{\pm}30.63$ Hz, $146.67{\pm}34.20$ Hz ; Female: $244.62{\pm}26.62$ Hz, $244.91{\pm}42.03$ Hz, $237.50{\pm}38.95$ Hz). The Maximal phonation time were $2.75{\pm}1.06$ (sec), $8.88{\pm}3.46$ (sec), $8.44{\pm}3.71$ (sec) statistically showing significant postoperative improve at preoperative, 1 week and 3 months. Conclusion : Injection laryngoplasty with CaHA in unilateral vocal cord paralysis is very safe and efficient procedure to improve a voice disorder, a swallowing difficulty, and a quality of life for those patients with a sacrificed RLN, a cancer invasion of the nerve, and a prolonged vocal cord paralysis which is more than six to twelve months.

  • PDF

A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS (주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구)

  • 김광화;최재구;선종호;김익수;윤진열
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.5
    • /
    • pp.219-225
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn't have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.

A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS (주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구)

  • 김광화;최재구;선종호;김익수;윤진열
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.219-219
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn′t have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.