• Title/Summary/Keyword: 119 fire department

Search Result 150, Processing Time 0.026 seconds

Fire Risk by Type of Building Exterior Material through Fire Cases (화재사례를 통한 건축물 외장재 종류별 화재발생위험성)

  • Lee, Jeong-Il;Kweon, Young-Hee
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.155-161
    • /
    • 2022
  • Recently, the number of cases of fire spreading due to exterior materials of buildings is increasing. Due to the nature of modern architecture, which emphasizes the aesthetics of buildings, because buildings pursue a splendid appearance, they are inexpensive and have relatively good insulation performance, but an increasing number of buildings are adopting insulation materials that have poor fire safety performance. The risk of spread is also greatly increased. Since the exterior wall of a building is made of a variety of materials and structures, it is composed of a combination of several elements, including materials such as insulation and finishing materials. Therefore, it was determined that it was necessary to introduce a more systematic evaluation method for building exterior materials, and to improve the system reflecting this, away from the existing evaluation method that only checked the fire safety performance of finishing materials.

Argumentation Analysis for 119 First aid Service and Policy (119 구급업무의 정책논쟁분석)

  • 우성천
    • Journal of Korean Institute of Fire Science & Engineering
    • /
    • v.1 no.2
    • /
    • pp.28-41
    • /
    • 2000
  • Since a few years ago, great disasters have often took place in domestic and abroad, such as Sampoong Department store collapse, Sea-land disaster accident, Incheon Hof fire accidents. Whenever a lot of accidents occurred such as fire, gas explosion, traffic accident, mountain accident, various disease, people required 119 first aid service. As the result, even for the last year, average 2,608 person per day were temporary treated and carried to near hospital by 119 system. But first-aid team or first grade EMT(emergency medical technician) that should provide high quality service and save important lives, might have negatively treated or made their duty only for simple transfer, when they were imminent of emergency case in every kinds of accident spot. Because they worried about medical dispute for "task restriction for EMT" decided by medical laws or rules of first aid. So it was proposed that "task restriction for EMT" should be mitigated or released in the possible range on this occasion.

  • PDF

A study on the current status and the obstacles to prehospital spinal motion restriction performed by 119 paramedics to major trauma patients (중증외상환자에 대한 119구급대원의 척추고정 실태 및 장애요인)

  • Park, Jung-Seung;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.89-106
    • /
    • 2020
  • Purpose: This study attempts to improve the status of emergency care for major trauma patients transferred by 119 paramedics by analyzing the status of emergency care and the obstacles to the spinal motion restriction (SMR) for major trauma patients. Methods: A total of 600 rescue logs were collected from major trauma patients transported by 119 paramedics in the C fire department from Jan. 1, 2015, to Dec. 31, 2017. And then, 280 questionnaires were collected from the 119 paramedics in C fire department from May 3 to Jun. 3, 2019. Data were analyzed using SPSS 24.0 version. Results: Among 499 spinal motion restriction adaptive patients, the spinal motion restriction rate was 51.1% (255 individuals). Lack of human resources and quality control problems were among the obstacles to spinal motion restriction. Conclusion: The 119 paramedics should improve their activeness and skills in performing emergency care, and since training and experience are of crucial importance, they should expand various education systematized according to demand.

A Study on the Establishment of an Integrated Management System for Forest Fire Prevention and Suppression Measures (산불예방 및 진압대책의 통합관리체계 구축 방안 연구)

  • Lee, Jeong-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.163-169
    • /
    • 2022
  • Recently, in Korea, if a very large forest fire occurs due to the people's carelessness, it is of great interest because it spreads into a large forest fire. If a wildfire spreads and becomes large, it will inflict great damage (appointment and property), and the damage is irreversible. The best way to extinguish a wildfire is to prevent it before it occurs. If a forest fire occurs due to a failure in prevention, the early firefighting activities to prevent the progress of the forest fire by promptly dispatching it by reporting it and approaching the site as soon as possible should now be managed with a systematic integrated management system. To do so, it is necessary to prepare a preventive system, such as issuing warnings for each weather condition by the Korea Forest Service, consisting of cooperation (support) activities for forest fire prevention by related organizations, etc. In order to minimize the loss of precious lives and forests, measures have been taken to establish a system, to establish a prompt and accurate situation reporting system, and to establish an integrated command system (ICS) for on-site commanders.

Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials (내화피복을 적용한 강합성보의 구조화재해석)

  • Jun Won Kang;Moon Soo Kang;Hyejin Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.137-145
    • /
    • 2023
  • This paper presents the effects of fire-resistant materials on the temperature and vertical deflection of a composite beam exposed to fire through nonlinear thermo-mechanical analysis. The fire was modeled using the standard fire curve proposed in American Society for Testing and Materials (ASTM) E119. Fire-resistant materials were modeled by reducing the heat transfer coefficient from the air layer to the beam. The temperature and vertical deflection of the uncoated composite beam were measured using a laboratory fire test, and the results of the structural fire analysis were verified through comparison with experimental results. By introducing the fire-resistance effect, the reduction in the temperature and deflection of the beam for the ASTM E119 standard fire can be reasonably estimated. Based on a case study of the heat transfer coefficient, the fire-resistant effect on the thermo-mechanical response of a composite beam in the event of a fire is presented.

A Study on the Activation·Specification of 119 Rescue & Care in JeJu (제주도 119구조·구급대의 활성화 및 전문화 방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik;Lee, Young-A
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.153-168
    • /
    • 2002
  • Since 1992, conventional fire fighting businesses have been converted into a metropolitan autonomous fire fighting system to be ready for a variety of disasters. However, the corresponding investment has been overlapped due to the non-integration of businesses to prevent any potential disasters, and a series of collaborative systems have been not functioning so well. In the meantime, our fire fighting sector has been trying to set up its own clean and faithful position by abolishing any inconvenient system or outsourcing private sectors, and expanded its work scope from conventional fire fighting even to rescue and emergency works. While focusing on handling disaster, the fire fighting sector has been widely trusted and reliable throughtout our nation. Moreover, our fire fighting sector has secured nation wide mobile organizations, technical personnel by field, special equipments and independent communication network. In addition, the fire fighting sector has knowledges, expertise and capabilities required for managing disasters, while in charge of almost every disaster management works including fire, explosion, collapse, disaster and flood. It becomes an organization for comprehensive disaster management under an absolute national trust, which is based on the system for prevention, preparation and countermeasure against a variety of disasters. Thus, our fire fighting sector must make many efforts and try to modernize conventional education and training. The ways to facilitate rescue and emergency works may include the nurture of technical fire fighting personnel along with modernized equipments, the reinforcement of rescue and emergency education, the facilitation of operating civil defense corps, the facilitation of operating volunteer fire fighting corps, the better arrangement of 119 briefing room for public healthcare in provincial offices, the sterilization of rescue instruments and equipments the better repair education for emergency rescue member, the establishment of regional emergency assistant system and the expansion of fire fighting personnel and equipments. In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations: Building up security system along with operational expansion, building up a system for emergency medical treatment, building up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119 we can review the following considerations : Improving the education for fire fighting training corps under Jeju Provincial Fire and Disaster Management Department, providing rescue members with more opportunities for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. If these requirements are met, it is expected that the fire fighting departments in Jeju province can cope with every accident and disaster a little more rapidly and quickly in compliance with local needs, so that they can keep their own position as a public fire fighting organization which may be trusted by the public.

  • PDF

A Comparative Analysis of 119 Emergency Medical Service Operation of Korea and Japan (한국과 일본의 구급실태 비교연구)

  • Baek, Hong-Sok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.199-210
    • /
    • 2004
  • Since the 119 fire department was legally permitted to serve in Emergency Medical Service(EMS)Operation of emergency patients in 1983, 119 EMS operation in general has made a big progress in serving the needs for emergency patients. Currently EMS operation is carried out by 119 EMS unit, private ambulance Co.,etc. But due to the public recognition and volunteers, 119 EMS operation carries the major share of the service. This observation is not surprising in that such a trends occured in Japan 20 years ago. This paper compared the 119 EMS operation conducted by the fire department in Korea with that of Japan in order to draw some inferences from the comparison. The results of the study compared to Japan were as follows: 1. Japan was higher 1.5 times in the number of EMS units per population(100,000), 1.1 times in the number of patient transports per unit. 2. Japan was higher 4.54 times in the number of the 119 EMS personnel per population(100,000), 30.6 times in that per square killometers, 30.6 times per 119 EMS unit, in per ambulance 2.48times. 3. Japan was higher 1.83 times in the number of ambulance per population(100,000), 1.26 times in that per square killo meters. 4. Japan was higher 1.7 times in the number of transport patients per population (100,000), but Korea was higher 2.68 times in the transport patients per EMS personal. 5. Compared to Japan, there was no emergency care related to ALS, for example, such as administering dugs orally and intravenously, interpreting elctrocardiograms, performing endotracheal tube or LMA insertion, using monitors and other complex equipments in Korea.

  • PDF

A Case of Resuscitation of an Electrocuted Child by a 119 Paramedic (감전으로 심정지된 소아환자 소생 1례)

  • Lee, Jae-Min;Kim, Dae-Won;Yun, Hyeong-Wan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.135-140
    • /
    • 2020
  • The purpose of this study was to prevent electric shock to children. children are at high risk of electrocution by accidents. In the present case, a 2-year-old child was electrocuted after inserting metal chopsticks into a home outlet. In this case, professional advanced cardiac life support (ACLS) was properly performed by a 119 paramedic, resulting in the return of spontaneous circulation (ROSC) in the child. There are very few successful cases of resuscitation of patients involved in electric shock accidents in Korea, and we report a case of ROSC and discharge and proper resuscitation by a 119 paramedic.

A study on preceptor's core competencies for junior 119 paramedics in prehospital field (후임구급대원을 위한 구급현장 프리셉터의 핵심역량에 대한 연구)

  • Kim, Eun-Ae;Yang, Jin-Cheol;Lee, Jeong-Hyeok;Jung, Sang-Woo;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.17-35
    • /
    • 2021
  • Purpose: This study aimed to investigate basic data on preceptor's core competencies required for junior 119 paramedics to improve the quality of emergency care in the prehospital field. Methods: From February 23 to March 10, 2021, data were collected through structured mobile questionnaires from 163 paramedics working in Sejong, Daejeon, and Chung Nam fire stations. The data were analyzed using SPSS version 25.0. Results: The average score of core competencies for junior 119 paramedics accounted for the importance of core competency (3.92 points), level of competence (3.43 points), educational needs (3.65 points). Among them, the importance of a role model accounted for 4.02 points, the highest among the sub-areas. Additionally, there was a significant correlation (r=.686), which was the highest, between the importance and educational needs of core competency; therefore, higher the importance of core competency, higher are the educational needs. Conclusion: Preceptor's core competencies concern three domains: role model, socialization facilitation, and instructional design. It would be more effective for those with higher professionalism and professional self-development needs to be trained as a prehospital preceptor.

Prehospital care and knowledge, prehospital care confidence toward the infant and toddlers of the 119 emergency medical technicians (119 구급대원의 영유아에 대한 응급처치 현황 및 응급처치 지식과 수행 자신감 비교)

  • Song, Eun-Hye;Lee, Kyoung-Youl
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.1
    • /
    • pp.19-33
    • /
    • 2015
  • Purpose: The purpose of this study was to improve the quality of prehospital care provided to infants and toddlers (preschoolers) based on questionnaire findings. Methods: A total of 1,634 running sheets from 119 centers of D city from patients older than 1 month and less than 7 years of age from January 1, 2013 to December 31, 2013 were reviewed for 119 emergency medical technicians (EMTs) activity analysis. And a self-reported questionnaire about knowledge and competency in prehospital care of preschoolers was completed by 159 EMTs at fire stations in D city. Data were analyzed using IBM SPSS Statistics for Windows, Version 21.0. Results: Of 1,634 patients, 58.6% were call to 119 due to disease, 33.8% due to injuries and 7.5% due to traffic accident. Knowledge and confidence in treating preschoolers was significantly higher among paramedic EMTs than basic EMTs. The 119 EMTs surveyed indicated that training for preschooler prehospital care was most needed. Conclusion: In order to provide high quality prehospital care for preschoolers transported to emergency rooms, it is necessary to equip ambulances with the proper equipment. In addition, EMTs should be provided educational opportunities and clinical training.