• Title/Summary/Keyword: 1-point method

Search Result 5,779, Processing Time 0.04 seconds

A Study on Effectiveness Analysis and Development of an Accident Prediction Model of Point-to-Point Speed Enforcement System (구간단속장비 설치 효과 분석 및 사고예측모형 개발)

  • Kim, Da Ye;Lee, Ho Won;Hong, Kyung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.144-152
    • /
    • 2019
  • According to the National Police Agency, point-to-point speed enforcement system is being installed and operated in 97 sections across the country. It is more effective than other enforcement systems in terms of stabilizing the traffic flow and inhibiting the kangaroo effect. But it is only 5.1% of the total enforcement systems. The National Police Agency is also aware that its operation ratio is very low and it is necessary to expand point-to-point speed enforcement system. Hence, this study aims to provide the expansion basis of the point-to-point speed enforcement operation through analysis of the quantitative effects and development the accident prediction model. Firstly, this study analyzed the effectiveness of point-to-point speed enforcement system. Naive before-after study and comparison group method(C-G Method) were used as methodologies of analyzing the effectiveness. The result of using the naive before-after study was significant. Total accidents, EPDOs and casualty crashes decreased by 42.15%, 70.64% and 45.30% respectively. And average speed and the ratio of exceeding speed limit decreased by 6.92% and 20.50%p respectively. Moreover, using the C-G method total accidents, EPDOs and casualty crashes decreased by 31.35%, 66.62% and 10.04% respectively. And average speed and the ratio of exceeding speed limit decreased by 3.49% and 56.65%p respectively. Secondly, this study developed a prediction model for the probability of casualty crash. It was dependant on factors of traffic volume, ratio of exceeding speed limit, ratio of heavy vehicle, ratio of curve section, and presence of point-to-point speed enforcement. Finally, this study selected the most danger sections to the major highway and evaluated proper installation sections to the recent installation section by applying the accident prediction model. The results of this study are expected to be useful in establishing the installation standards for the point-to-point speed enforcement system.

An international Comparison Measurement of Silicon Wafer Sheet Resistance using the Four-point Probe Method

  • Kang, Jeon-Hong;Ying, Gao;Cheng, Yuh-Chuan;Kim, Chang-Soo;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.325-330
    • /
    • 2015
  • With approval from the Asia Pacific Metrology Program Working Group on Materials Metrology (APMP WGMM), an international comparison for sheet resistance standards for silicon wafers was firstly conducted among Korea Research Institute of Standards and Science (KRISS) in Korea, CMS/ITRI in Taiwan, and NIM in China, which are national metrology institutes (NMIs), from August 2011 to January 2012. The sheet resistance values of the standards are $10{\Omega}$, $100{\Omega}$, and $1000{\Omega}$; the measurement was conducted in sequence at KRISS, CMS/ITRI, NIM, and KRISS again using the four-point probe method with single and dual configuration techniques. The reference value for the measurement results of the three NMIs was obtained through averaging the values of the three results for each sheet resistance range. The differences between the reference value and the measured values is within 0.22% for $10{\Omega}$, 0.17% for $100{\Omega}$, and 0.12% for $1000{\Omega}$. Therefore, the international consistency for conducting sheet resistance measurements is confirmed within 0.22% through the APMP WGMM approved comparison.

Design of Fixed-point Pulse Shaping FIR fitters Using Mixed Integer Linear Programming (혼합 선형계획법을 이용한 고정소수점 파형 성형 FIR필터의 설계)

  • 오우진
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.105-113
    • /
    • 2000
  • This paper proposes the optimal design method of PSF(pulse shaping filter) with fixed-point coefficients, often used in digital communication system. Though RCF (Raised Cosine Filter) and Root-Squared RCF have less attenuation in stopband and are designed with floating point coefficients, those are selected by the reason that the design is simple. In this paper, 1 introduce the optimal design method for fixed point PSF including Root Squared type by using mixed integer linear programming. Through some design examples, it is shown that the proposed method better performs in ISI and requires less complexity. The complexity of the proposed filter is reduced to 20% as compared to conventional RCF and Root Squared RCF. For IS-95, that is the standard of CDMA system, the proposed filter reduces ISI up to 75% compared to the standard transmission filter.

  • PDF

A STUDY ON MUTATIONS OF P53 TUMOR SUPPRESSOR GENE IN ORAL TUMORS (구강종양에서 p53 종양억제 유전자의 돌연변이에 관한 연구)

  • Joo, Seong-Chai;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.45-52
    • /
    • 2000
  • Nowadays, there are a lot of evidence that mutation of the p53 tumor suppressor gene is one of the most common genetic abnormalities in neoplastic progression. In this study, we analyzed 20 specimens of oral tumors(squamous cell carcinoma 14 cases, ameloblastoma 3 cases, adenoid cystic carcinoma 2 cases, malignant schwannoma 1 case)using polymerase chain reaction and direct sequencing which used an automated DNA sequencer and software for detection of mutations. Polymerase chain reactions were performed with 4 sets of primers encompassing exon 5, 6, 7, 8, and direct sequencing method was employed. The results were as followings. 1. We detected 10 point mutations out of 20 specimens (50%). 2. The genetic alterations included 7 mis-sense mutations resulting in single amino acid subtitutions, 2 silent mutations, 1 non-sense mutations encoding a stop codon. 3. Mutations were mostly in exon 7(7 out of 10 mutations, 70%) and involved codons 225, 234, 235, 236, 238, 247. 4. Therse were 4 cases of $T{\rightarrow}A$ transversion, 2 cases of $C{\rightarrow}A$ transversion, $A{\rightarrow}G$ transition, 1 case of $C{\rightarrow}G$, $T{\rightarrow}G$ transversion respectively. 5. We could find out point mutations more conveniently using PCR - Automated Direct Sequencing method.

  • PDF

NURBS Surface Reconstruction from an Unstructured Point Cloud (비조직화된 점군으로부터 NURBS 곡면 모델의 생성)

  • Li, Ri-Xie;Kim, Seok-Il
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1564-1569
    • /
    • 2007
  • This study concerns an advanced NURBS surface reconstruction method, which is based on the NURBS surface model fitting to the unstructured point cloud measured from an arbitrary complex shape. The concept of generating a simple triangular mesh model was introduced to generate a quadrilateral mesh model well-representing the topological characteristics of point cloud. The NURBS surface reconstruction processes required the use of the various methodologies such as QEM algorithm, merging scheme of pair-wise triangular mesh, creation algorithm of $G^1$ continuous tensor product NURBS surface patch, and so on. The effectiveness and reliability of the proposed NURBS surface reconstruction method were validated through the simulation results for the geometrically and topologically complex shapes.

  • PDF

An Analysis of location of Needle Entry Point and Palpated PSIS in S1 Nerve Root Block

  • Kim, Shin-Hyung;Yoon, Kyung-Bong;Yoon, Duck-Mi;Choi, Seong-Ah;Kim, Eun-Mi
    • The Korean Journal of Pain
    • /
    • v.23 no.4
    • /
    • pp.242-246
    • /
    • 2010
  • Background: The first sacral nerve root block (S1NRB) is a common procedure in pain clinic for patients complaining of low back pain with radiating pain. It can be performed in the office based setting without C-arm. The previously suggested method of locating the needle entry point begins with identifying the posterior superior iliac spine (PSIS). Then a line is drawn between two points, one of which is 1.5 cm medical to the PSIS, and the other of which is 1.5 cm lateral and cephalad to the ipsilateral cornu. After that, one point on the line, which is 1.5 cm cephalad to the level of the PSIS, is considered as the needle entry point. The purpose of this study was to analyze the location of needle entry point and palpated PSIS in S1NRB. Methods: Fifty patients undergoing C-arm guided S1NRB in the prone position were examined. The surface anatomical relationships between the palpated PSIS and the needle entry point were assessed. Results: The analysis revealed that the transverse and vertical distance between the needle entry point and PSIS were $28.7{\pm}8.8mm$ medially and $3.5{\pm}14.0mm$ caudally, respectively. The transverse distance was $27.8{\pm}8.3mm$ medially for male and $29.5{\pm}9.3mm$ medially for female. The vertical distance was $1.0{\pm}14.1mm$ cranially for male and $8.1{\pm}12.7mm$ caudally for female. Conclusions: The needle entry point in S1NRB is located on the same line or in the caudal direction from the PSIS in a considerable number of cases. Therefore previous recommended methods cannot be applied to many cases.

APPLICATION OF FIXED POINT THEOREM FOR UNIQUENESS AND STABILITY OF SOLUTIONS FOR A CLASS OF NONLINEAR INTEGRAL EQUATIONS

  • GUPTA, ANIMESH;MAITRA, Jitendra Kumar;RAI, VANDANA
    • Journal of applied mathematics & informatics
    • /
    • v.36 no.1_2
    • /
    • pp.1-14
    • /
    • 2018
  • In this paper, we prove the existence, uniqueness and stability of solution for some nonlinear functional-integral equations by using generalized coupled Lipschitz condition. We prove a fixed point theorem to obtain the mentioned aim in Banach space $X=C([a,b],{\mathbb{R}})$. As application we study some volterra integral equations with linear, nonlinear and single kernel.

FUZZY STABILITY OF A CUBIC-QUADRATIC FUNCTIONAL EQUATION: A FIXED POINT APPROACH

  • Park, Choonkil;Lee, Sang Hoon;Lee, Sang Hyup
    • Korean Journal of Mathematics
    • /
    • v.17 no.3
    • /
    • pp.315-330
    • /
    • 2009
  • Using the fixed point method, we prove the generalized Hyers-Ulam stability of the following cubic-quadratic functional equation $$(0.1)\;\frac{1}{2}(f(2x+y)+f(2x-y)-f(-2x-y)-f(y- 2x))\\{\hspace{35}}=2f(x+y)+2f(x-y)+4f(x)-8f(-x)-2f(y)-2f(-y)$$ in fuzzy Banach spaces.

  • PDF