• Title/Summary/Keyword: 1/4차 시험

Search Result 1,649, Processing Time 0.032 seconds

Examination for Efficiency of Groundwater Artificial Recharge in Alluvial Aquifer Near Nakdong River of Changweon Area, Korea (창원지역 낙동강 하천수와 주변 충적층을 이용한 지하수 인공함양의 효율성 평가)

  • Moon, Sang-Ho;Ha, Kyoochul;Kim, Yongcheol;Koh, Dong-Chan;Yoon, Heesung
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.611-623
    • /
    • 2014
  • The alluvial aquifer, widely developed near the four major rivers such as Nakdong River, can be used effectively for groundwater artificial recharge and is expected to be the future water resources in Korea. This study is aimed at examining the impact of repeatedly injected river water into the riverside alluvial aquifer on injection rate or efficiency in its system at Changweon area. For this, injection tests were performed two times, first on June 19 and second on September 25 through October 9, 2013, and the mixing ratios of river water to groundwater were used as the tool to compare the efficiency of injection. The mixing ratios were evaluated by using electrical conductivities of injected river water (average $EC=303{\mu}S/cm$) and groundwater ($EC{\fallingdotseq}6,000{\mu}S/cm$) measured at 20 m depth of four observation wells installed 10 m apart from each injection well. The result shows the remarkable differences on two respects. First, in some observation well, detection time for incipient injection effect during $2^{nd}$ injection test was shown to be much slower than that of $1^{st}$ injection test. Second, the hourly increasing rate of mixing ratios in $2^{nd}$ test was revealed to be reduced much more than that of $1^{st}$ test. This means that the efficiency of injection was badly deteriorated by only 1,210 minute injection work. Therefore, injection water needs to be adequately treated beforehand and repeated pumping work and/or resting phase is needed afterwards. To a certain extent, the improvement of water quality in saline aquifer was verified in this system by injection tests.

The development of a deQing controller to improve the output of a modulator (Modulator의 출력안정도 향상을 위한 DeQing Controller 개발)

  • Kim, S.H.;Park, S.S.;Hwang, J.Y.;Han, Yeong-Jin;Nam, S.H.;Oh, J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.123-125
    • /
    • 2007
  • 포항가속기연구소가 추진 중인 제4세대 방사광가속기에는 100 PPM급의 클라이스트론 펄스전압 안정도가 요구된다. 이러한 안정도는 PFN(pulse forming network)에 충전되는 전압을 얼마나 정밀하게 제어하는가에 따라서 결정된다. PFN의 최종운전 전압은 deQing circuit에 triggering되는 시점에 따라서 결정된다. DeQing trigger system은 PFN의 충전전압과 기준전압을 비교하여 충전전압이 기준전압보다 커지는 시점에서 charging choke(충전 쵸크)의 2차에 구성된 deQing 회로의 SCR를 트리거 시켜서 충전 쵸크 1차와 2차의 권선비율이 25:1인 충전 쵸크의 2차를 단락시켜 1차에 흐르는 전류를 2차로 빼주어서 PFN 커패시터에 더 이상 충전되지 않게 하는 구조로 되어있다. DeQing circuit에 triggering되는 시점을 정밀하게 제어하기 위하여 PFN 충전전압을 미분하여 그 출력전압에 비례하여 트리거 출력을 지연시키는 기능과 analog 신호를 digital 신호로 변환하는 기능을 사용하였다. 이 논문에서는 deQing 시스템에 관련된 회로 및 시험결과에 대하여 설명하고자 한다.

  • PDF

A Study on Development of Evaluation Method on Riverine Ecobelt (수변 생태벨트 평가방법 개발에 관한 연구)

  • Cho, Yong-Hyeon;Choi, Dae-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.123-132
    • /
    • 2014
  • This study aims to develop the diagnostic evaluation method of the riverine ecobelt for construction, conservation, and maintenance of the riverine ecobelt. The value indices in the proposed evaluation method are composed of total 5 fields and 19 elements. The 5 fields are flood control, environmental function, growth of plants, ecobelt function, and restoration potential. Flood control field is composed of total 3 elements such as length, width, and density of green area. Environmental function field is composed of 4 elements such as park use, landscape boundary and edge, microclimate control, non-point pollution control. Growth of plants field is composed of 6 elements such as species composition, forest height, stratum structure, vine plants, plant vitality, and succession of plants. Ecobelt function field is composed of 4 elements such as longitudinal connectivity, lateral connectivity, in-stream forest or habitat, roads on bank top. Restoration potential field is composed of 2 elements such as landform and land use of the immediate vicinity. The score system ranging 1~4 was adopted. The weighting parameters of elements were unified with each other. The final grade system ranging 1~5(1: very good~5: very bad) was adopted, and the final grade was evaluated by the mean values of each field. According to the test application of the diagnostic evaluation method of the riverine ecobelt, the final grades showed effectively the real condition of each site.

Temperature and Pressure Measurement on the Flame Deflector during KSLV-I Flight Tests (나로호 비행시험을 통한 화염유도로의 온도 및 압력 측정)

  • Jung, Il-Hyung;Moon, Kyung-Rok;Kang, Sun-Il;An, Jae-Chel;Ra, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.4
    • /
    • pp.378-384
    • /
    • 2011
  • During the flight test of KSLV-I, various sensors are installed in the launch pad and the flame deflector to measure the flame characteristics and their influences on the launch complex when a launch vehicle lifts off. Parameter Measurement System is responsible for acquiring the above flight test data. The measurement methodology such as the configuration of measurement system, sensor locations and data acquisition procedures are presented. And this paper compares and explains the characteristics of data sets measured during two flight tests.

ITER 블랑켓 일차벽 고유접합법 개발을 위한 표준목업 고열부하 시험

  • Kim, Seok-Gwon;Lee, Dong-Won;Bae, Yeong-Deok;Yun, Jae-Seong;Jeong, Gi-Seok;Hong, Bong-Geun;Jeong, Hyeon-Gyu;Jeong, Yang-Il;Park, Jeong-Yong;Choe, Byeong-Gwon;Jeong, Yong-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.275-275
    • /
    • 2010
  • 국제핵융합실험로 (ITER)의 블랑켓 일차벽 조달 자격 획득을 위한 검증시험을 수행하여 1단계를 2009년 완료하였고, 2단계는 2011년 예정으로 진행 중이다. 우리나라는 이미 1단계 검증시험에서 2 개의 일차벽 목업 (First Wall Qualification Mockup ; FWQM)을 제출하여 시험을 성공적으로 통과하였고, 2단계 검증 시험을 위해 semi-prototype 제작 기술 및 시험 기술을 개발 중이다. 블랑켓 일차벽 검증 시험 및 제작 기술을 확보하기 위한 고유접합법 개발을 위해서 표준 크기($80\;mm{\times}80\;mm$)의 목업을 제작하여 국내 고열부하 시험 시설에서 접합 방법의 타당성을 확인하였다. 표준목업은 HIP (Hot Isostatic Pressing) 접합법으로 stainless steel과 Cu 냉각부를 제작하고, 다시 $80\;mm{\times}80\;mm$ Be tile을 HIP 방법으로 냉각부에 접합하여 제작한다. 고유접합법 개발을 위해서 Be과 Cu 냉각부 계면에 Cr($1\;{\mu}m$)/Cu($10\;{\mu}m$), Ti($5\;{\mu}m$)/Cu($10\;{\mu}m$) 층을 코팅하여 Be 접합 성능을 개선하였으며, 기존의 접합 계면과 차별화된 기술을 확보하였다. 표준목업의 전체 크기는 $80\;mmW{\times}80\;mmL{\times}84\;mmH$ 이고, 1차로 총 6개, 2차로 4개를 제작하였으며 제작 과정 및 제작 전후에 파괴검사, 비파괴검사를 수행하여 접합의 건전성을 확인하였다. 제작 완료된 표준 목업은 냉각 관로를 장착하여 국내의 고열부하 시험시설인 KoHLT-1에 장착하여 성능 시험을 수행하였다. 고열부하 시험 시설의 냉각수 조건은, 온도 $25^{\circ}C$(실온), 유량 0.15 kg/sec이고, 고열 부하 조건에서는 0.5, 1.0, $1.5\;MW/m^2$의 screening 시험을 거친 후 1.5 MW/m2에서 cycle 시험을 진행하였다. 각 목업의 고열부하 시험을 마친 후 비파괴 검사의 일환으로 UT(Ultrasonic test) 시험을 수행하여 열부하 시험 전후의 목업 건전성을 확인하였다. 고유접합법을 이용하여 개발한 표준 목업의 고열부하 시험을 통해서 접합법의 타당성 및 건전성을 확인하였고, 향후 블랑켓일차벽 조달 검증 2단계 시험에서 semi-prototype 제작 및 고열부하 시험에 대비하고, ITER 관련 핵심 기술 개발 목표를 달성할 것이다.

  • PDF

Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets (점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구)

  • Kim, Soo-Yeon;Park, Jong-Sun;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.377-386
    • /
    • 2021
  • In April 2019, this study was enacted as a test method for the performance of waterproof layers in an environment where complex deterioration and structural behavior are simultaneously applied, but some existing standards were implemented to point out the errors of the method that should be supplemented. Thus, in establishing standards for (tentative) adhesive waterproofing sheets, field workability and quantification of test results were studied on the structural behavior response performance test methods included as test items. In addition, the performance evaluation of adhesive-type composite waterproof sheets was conducted based on the considered contents to review improvements such as applicability as an item of standard standards and field workability related problems.

An Optimum Summer Cultivation Sowing Date for Seed Production of Oats (Avena sativa L.) (귀리 종자 생산을 위한 여름 재배의 적정 파종 시기 구명)

  • Park, Jin-Cheon;Kim, Yang-Kil;Yoon, Young-Mi;Choi, Su-Yeon;Park, Jong-Ho;Park, Hyoung-Ho;Ra, Kyungyoon;Park, Tae-Il
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.67 no.3
    • /
    • pp.180-188
    • /
    • 2022
  • This study was conducted to determine the optimal sowing date for seed yield of summer oat (Avena sativa L.) cultivars "Darkhorse (DH)" and "Highspeed (HS)" in Wanju, Jeonbuk province between 2017 and 2018. We investigated seed yield from 4 sowing dates: July 15, July 30, August 15, and August 30. We evaluated the agronomic characteristics of summer oats (DH and HS). We found the heading date of all cultivars to be within 50 days. Delayed sowing resulted in significantly increased plant height for both years and cultivars. There was no significant difference in spike length of DH and HS which ranged from 12.8 to 17.8 cm. The sowing date of July 30 produced a higher number of grains per spike, but this yield differed significantly by year and cultivars. In 2017, the first sowing resulted in the lowest DH yield at 132 kg per 10a, while the second sowing had the highest yield at 227 kg. HS yield was the lowest in the first sowing at 126 kg and the highest in the third sowing at 219 kg. In 2018, DH had the lowest yield from the first sowing at 184 kg per 10a, and the highest from the second sowing at 240 kg, but there was no significant difference between these yields. The first sowing for HS gave the lowest yield at 160 kg, and the second sowing produced the highest at 258 kg. The germination rate of harvested seeds from each sowing date in 2017 and 2018 was found to be higher than 85% and there was no significant difference between the two cultivars in the 2018 germination rate test. Thus, we found the optimal sowing date for summer cultivation of oats for the highest seed yield to be between July 30 (second sowing) and August 15 (third sowing).

Effects of Illite Supplementation on the Meat Quality of Finishing Pigs (황토성분(Illite) 첨가 급여가 비육돈의 육질에 미치는 영향)

  • 김천제;이의수;송민석;조진국
    • Food Science of Animal Resources
    • /
    • v.20 no.2
    • /
    • pp.152-158
    • /
    • 2000
  • This study was conducted to investigate the influence of feeding illite(yellow soil component) on meat quality of pork. 40 pigs were fed with commercial formulated feed (control group) and 1% illite added feed(treatment group). Pigs grown up to 100~110kg of weight were slaughtered in commercial abattoir. After chilling for 24hours, samples were collected from M. longissimus dorsi muscle, and stored at $4\pm$$1^{\circ}C$ for analyses. The physico-chemical properties was determined during storage days as follows. Ultimate pH was not significantly different between control and treatment(pH 5.58 and 5.60, respectively). Water-holding capacity measured using filter paper press method of the treatment group was slightly higher than that of the control group. Cooking loss of treatment group were significantly lower than that of the control group at 1 and 7 days(p〈0.05). Shear force between control and treatment group was not different. L*- and a*-value were not significantly different between the two groups(p〉0.05), but b*-value of treatment group was lower than that of the control group(p〈0.05). The drip loss of all samples was increased with storage days, and that of the treatment group was significantly lower than that of the control at 1 and 3 day storage. Meat color measured using NPPC pork quality standards was not significantly different between the two groups(p〉0.05), but marbling content of the treatment group was significantly higher than that of the control group(p〈0.05). Sensory characteristics of, flavor taste and tenderness did not show significant differences(p〉0.05), but juiciness of the treatment group showed higher value than that of the control group(p〈0.05)

  • PDF

Flexural Design and Experiments on Reinforced Concrete Filled PHC Pile (철근 콘크리트 충전 PHC말뚝의 휨 설계 및 성능 평가)

  • Kim, Jeong-Hoi;Jung, Hae-Kwang;Park, Young-Shik;Min, Chang-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • The objective of this study is theoretical and empirical evaluation of the flexural performance of concrete filled pretensioned spun high strength concrete pile with ring type composite shear connectors (CFP pile). The specimens are comprised of standard CFP pile, PHC pile+composite shear connector+filed concrete (CFP-N-N), standard CFP pile with $1^{st}$ reinforcements (H13-8ea), and standard CFP pile with $1^{st}$ and $2^{nd}$ reinforcements(H19-8ea). Flexural performance evaluation results showed that the ductility is improved with increased steel ratio, which leads to the increased maximum load by 46.4% (with $1^{st}$ reinforcement) and 103.9% (with $1^{st}$ and $2^{nd}$ reinforcements) compared to standard CFP ( CFP-N-N). Comparing with the predicted ultimate limit state values of the CFP pile design method and the experimental results, the design method presented in this study is reasonable since safety factor of 1.23 and 1.40 times for each reinforcement step are secured.

The Effect of Bearing Capacity Increasement for Driven Pile in Silt (실트지반에 타입된 말뚝의 지지력 증가효과)

  • Yeo, Byung Chul;Oh, Se Wook;Bae, Woo Seok;Ahn, Byung Chul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.19-26
    • /
    • 2003
  • Recently, for the design of pile foundations on the soft ground condition, it is recognized that set-up effects are another important factor which influence the characteristics of bearing capacity of pile. In this paper, the thirteen dynamic pile loading tests were performed at the two different construction sites and the end of initial driving(EOID) were also performed and then restrike tests were performed after certain time lag. The H-pile, pipe pile, PHC pile are installed by driving into the loose silty soil and then restrike tests were performed. Nine days after pile driving, the bearing capacity of H and pipe pile were increased whereas there is not bearing capacity increasement with PHC pile. When the dense silty soil, the restrike test results showed that the bearing capacity of H and pipe pile increased up to 1.17 times. The 1-st and 2-nd restrike tests performed after 6 and 12 day, respectively. The results showed that the bearing capacity of PHC pile was decreased but the bearing capacity of piles were increased up to 1.38 times after 13 days with the third restrike test.

  • PDF