• 제목/요약/키워드: 0.9 V to 5 V

검색결과 2,836건 처리시간 0.034초

Pentacyclo ($5,3,0,0^{2,5},06{3,9},0^{4,8})-decane-6,10-dione의 합성 (Studies on the Synthesis of Pentacyclo ($5,3,0,0^{2,5},06{3,9},0^{4,8})-decane-6,10-dione)

  • 정의준;장세희
    • 대한화학회지
    • /
    • 제18권6호
    • /
    • pp.437-442
    • /
    • 1974
  • Cyclopentanone을 출발 물질로 하여 60%의 좋은 총 수득률로 pentacyclo ($5,3,0,0^{2,5},06{3,9},0^{4,8})-decane-6,10-dion을 합성하였다. Cyclopentanone 으로부터 그의 ethylene ketal(I)을 합성하여 pyridinium bromide perbromide로서 브롬화시키고 브롬화 ketal(II)을 다시 dehydrobromination 시켜 cyclopentadienone-ethylene ketal의 dimer를 합성하였다. Ethylene ketal의 dimer(III)를 다시 가수분해시켜 dicyclopentadiene-1,8-dione(IV)을 합성하고 이 diketone(IV)을 photochemical cyclization에 의하여 pentacyclo ($5,3,0,0^{2,5},06{3,9},0^{4,8})-decane-6,10-dione(V)을 합성하였다.

  • PDF

Electrical Properties of PCCYA-doped ZnO-based Varistors

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권3호
    • /
    • pp.96-100
    • /
    • 2008
  • The microstructure, voltage-current, and capacitance-voltage relations ofP CCYA doped ZnO-based varistors were investigated for different amounts of $Al_2O_3$. As the $Al_2O_3$ amount increased, the average grain size (d) increased from d=4.3 to $d=5.5{\mu}m$ and the sintered density $({\rho})$ increased from ${\rho}=5.63$ to ${\rho}=5.67g/cm^3$. As the $Al_2O_3$ amount increased, the breakdown voltage $(V_B)$ increased from $V_B=633$ to $V_B=71$ V/mm and the non-ohmic coefficient $({\alpha})$ increased from ${\alpha}=47$ to ${\alpha}=4$. $Al_2O_3$ served as a donor due to the donor density $(N_d)$, which increases in the range of $N_d=0.77-1.85{\times}10^{18}/cm^3$ with increasing amount of $Al_2O_3$.

Hot Wall Epitaxy(HWE)법에 의한 $AgInS_2$단결성 박막의 성장과 가전자대 갈라짐에대한 광전류 연구 (Photocurrent Study on the Splitting of the Valence Band and Growth of $AgInS_2$GaAs Single Crystal Thin Film by Hot Wall Epitaxy)

  • 홍광준
    • 한국결정학회지
    • /
    • 제12권4호
    • /
    • pp.197-206
    • /
    • 2001
  • 수평 전기로에서 AgInS₂ 다결정을 합성하여 HWE(Hot Wall Epitaxy)방법으로 AgInS₂ 단결정 박막을 반절연성 GaAs(100)기판에 성장시켰다. AgInS₂ 단결정 박막의 성장 조건은 증발원의 온도 680℃, 기판의 온도 410℃였고 성장 속도는 0.5㎛/hr였다. AgInS₂ 단결정 박막의 결정성의 조사에서 10 K에서 광발광(photoluminescence)스펙트럼이 597.8 nm(2.0741 eV)에서 exciton emission스펙트럼이 가장 강하게 나타났으며, 또한 이중결정 X-선 요동곡선(DCRC)의 박폭치(FWHM)도 121 arcsec로 가장 작아 최적 성장 조건임을 알수 있었다. Hall 효과는 van der Pauw 방법에 의해 측정되었으며, 온도에 의존하는 운반자 농도와 이동도는 293K에서 각각 9.35×10/sup 16/㎤, 294㎠/V·s 였다. AgInS₂ /SI(SEmi-Insulated) GaAs(100) 단결정 박막의 광흡수와 광전류 spectra를 293K에서 10K까지 측정하였다. 광흡수 스펙트럼으로부터 band gap E/sub g/(T)는 Varshni 공식에 따라 계산한 결과 2.1365eV-(9.89×10/sup-3/eV/K/)T²(T+2930K)이었으며 광전류 스펙트럼으로부터 Hamiltopn matrix(Hopfield quasicubic mode)법으로 계산한 결과 crystal field splitting Δcr값이 0.1541eV이며 spin-orbit Δso 값은 0.0129eV임을 확인하였다. 10K일때 광전류 봉우리들은 n=1 일때 A₁-, B-₁와 C₁-exction 봉우림을 알았다.

  • PDF

생체용 Ti 합금의 부식특성 (Corrosion Characteristics of Titanium Alloys for Medical Implant)

  • 한준현;이규환;신명철
    • 분석과학
    • /
    • 제9권2호
    • /
    • pp.192-197
    • /
    • 1996
  • 현재 사용되고 있는 생체용 금속재료로 스테인레스강(SUS 316), Co-Cr강, 순수 Ti, Ti-6Al-4V이 많이 사용되고 있으며 그 중에서도 특히 Ti이 각광을 받고 있다. 그러나 순수한 Ti은 생체적합성과 내식성은 좋은 반면 기계적 성질이 합금에 비해 뒤떨어지고, Ti-6Al-4V은 V의 세포독성이 지적되고 있어 이러한 문제를 해결하기 위해 세포독성이 없는 함금원소를 Ti에 첨가한 새로운 합금을 설계하였다. 그 중에서 Ti-20Zr-3Nb-3Ta-0.2Pd-1In과 Ti-5AI-4Zr-2.5Mo은 기계적 성질도 뛰어나고 우수한 전기화학적 부식특성을 가지고 있었다.

  • PDF

L-${\alpha}$-Phosphatidylethanolamine 단분자층 LB막의 안정성에 관한 연구 (A Study on the Stability of Langmuir-Blodgett(LB) Films of L-${\alpha}$-Phosphatidylethanolamine Monolayer)

  • 박근호
    • 한국응용과학기술학회지
    • /
    • 제31권1호
    • /
    • pp.44-49
    • /
    • 2014
  • 인지질(L-${\alpha}$-phosphatidylethanolamine, LAPE) 단분자층 LB막의 전기화학적 특성을 통하여 그 안정성을 순환전압전류법으로 조사하였다. LAPE 단분자층 LB막은 ITO glass에 LB법을 사용하여 제막하였다. 전기화학적특성은 0.5 N, 1.0 N, 1.5 N 및 2.0 N $KClO_4$ 용액에서 3 전극 시스템으로 순환전압전류법에 의해 측정하였다. 측정범위는 연속적으로 1650 mV로 산화시키고, 초기 전위인 -1350 mV로 환원시켰다. 주사속도는 각각 50, 100, 150, 200 및 250 mV/s로 설정하였다. 그 결과 LAPE LB막은 순환전압전류곡선으로부터 산화전류로 인한 비가역공정으로 나타났다. LAPE LB막은 전해질농도가 0.01 N, 0.05 N. 0.10 N, 0.15 N 과 0.20 N $KClO_4$ 용액에서 확산계수(D)는 각각 195, 15.9, 5.75, 1.38 및 $0.754cm^2s^{-1}{\times}10^{-9}$을 얻었다.

Nerve length measurement method in a radial motor nerve conduction study

  • Kim, Jae-Gyum;Kim, Yoohwan;Seok, Hung Youl;Kim, Byung-Jo
    • Annals of Clinical Neurophysiology
    • /
    • 제19권1호
    • /
    • pp.28-33
    • /
    • 2017
  • Background: Previous studies of radial nerve conduction study (NCS) did not present how to measure the length of the radial nerve across the elbow, and did not even mention how to manage the spiral course of the nerve. This study aimed to applicate the most reliable method to measure the length of the radial nerve during NCS. Methods: Three points (A, B, and C) were determined along the relatively straight course of the radial nerve. The distance was measured using three different methods: L1) straight distance corresponding to the A-C distance, L2) sum of the distances corresponding to the A-B-C distance, L3) based on the L2, but the elbow is flexed at a $45^{\circ}$ angle. We compared the three methods of distance measurement and the calculated nerve conduction velocities (V1, V2, and V3) in normal healthy subjects. Results: 19 normal participants were enrolled. The mean value for method L1, L2 and L3 were $22.5{\pm}1.8cm$, $24.0{\pm}2.1cm$, and $23.2{\pm}2.1cm$ (p < 0.001). Calculated conduction velocities using those distance measurement methods as follows (p < 0.001): V1 ($60.9{\pm}2.7m/s$), V2 ($64.6{\pm}3.3m/s$), and V3 ($63.4{\pm}3.9m/s$). V2 was significantly greater than V1 and V3 (p < 0.001, p = 0.010, respectively). Conclusions: The distance measurement using a stopover point near the lateral epicondyle between two stimulus points in position of a fully extended elbow with forearm pronation is the most appropriate posture for radial motor NCS.

$ZnO-Pr_6O_{11}-CoO-Dy_2O_3$계 바리스터의 I-V 특성에 $Pr_6O_{11}/CoO$ 조성비 영향 (Influence of $Pr_6O_{11}/CoO$ Composition Ratio on I-V Characteristics of $ZnO-Pr_6O_{11}-CoO-Dy_2O_3$ Based varistors)

  • 남춘우;류정선;윤한수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.179-184
    • /
    • 2000
  • The I-V characteristics of $ZnO-Pr_6O_{11}-CoO-Dy_2O_3$ based varistors were investigated in the $Pr_6O_{11}/CoO$ composition ratio range of 0.5/0.5 to 1.0/1.0 and sintering temperature range of 1300 to $1350^{\circ}C$ as the basic study to develop the advanced $Pr_6O_{11}$-based ZnO varistors. All varistors except for $Pr_6O_{11}$/CoO = 0.5/1.0 exhibited the best I-V characteristics at $1350^{\circ}C$. However, the varistors with $Pr_6O_{11}$/CoO= 0.5/1.0 exhibited the best I-V characteristics at $1350^{\circ}C$. The varistors with $Pr_6O_{11}$/CoO= 0.5/1.0 of all varistors exhibited the best I-V characteristics, which the nonlinear exponent is 36.9 and the leakage current is 7.6 ${\mu}A$ Therefore, it was estimated that ZnO-$Pr_6O_{11}-CoO-Dy_2O_3$ ceramics with $Pr_6O_{11}$/CoO= 0.5/1.0 will be usefully used as varistor materials in the future.

  • PDF

적송잎증류농축액의 항균활성 및 항산화활성 (Antibacterial and Antioxidant Activities of the Red Pine Leaf Distilled Concentrate)

  • 민경철;임승철;김보경;김근대;김익종;이상현;김미향
    • 생명과학회지
    • /
    • 제31권10호
    • /
    • pp.937-943
    • /
    • 2021
  • 본 연구에서는 적송잎증류농축액을 이용하여 그람음성 병원성 균주들에 대한 항균활성 및 항산화활성을 측정하였다. 적송잎증류농축액 에멀션의 항균활성을 paper disc법으로 측정한 결과, 그람음성 병원성 균주인 E. coli, S. typhi, V. parahaemolyticus에 대해 항균활성을 나타냈으며, 5% (v/v)의 농도에서 각각 12 mm, 10 mm, 9 mm의 생육저해환(clear zone)을 보였다. 또한, 가장 낮은 농도인 0.5% (v/v)의 농도에서도 3종의 균주 모두에서 활성을 보였다. 그러나 그람양성 병원성 균주에 대한 항균활성은 나타나지 않았다. 적송잎증류농축액의 항균활성을 비탁법으로 측정한 결과, paper disc법의 결과와 마찬가지로 그람음성 병원성 균주인 E. coli, S. typhi, V. parahaemolyticus에 대해 항균활성을 나타냈다. V. parahaemolyticus에서는 5% (v/v)의 농도에서 음성 대조군에 비해 60% 이상의 생장억제를 보였고, E. coli에서는 배양 4시간에서 64.3%, S. typhi에서는 배양 4시간과 5시간에서 각각 94.2%, 94.1%의 생장억제를 보였다. 적송잎증류농축액 에멀션의 항산화활성을 DPPH radical 소거능으로 측정 한 결과, 1.0% (v/v)의 농도에서 55.81%의 활성을 나타냈다. 적송잎증류농축액 에멀션의 항산화활성을 ABTS radical 소거능으로 측정한 결과, 1.0% (v/v)의 농도에서 18.44%의 활성을 나타냈다. 본 연구를 통해, 적송잎증류농축액의 생리활성인 항균활성 및 항산화활성을 검증하였으며, 이를 이용하여 기능성이 강화된 식품 및 화장품의 개발이 가능할 것으로 기대된다.

비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구 (A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer)

  • 염미숙;이우석;김대섭;백금문
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.21-28
    • /
    • 2014
  • 목 적 : 비소세포 폐암의 치료용적의 크기가 크거나 폐 용적이 작고, 몸의 정중선(Mid line)에 위치한 경우 척수의 허용선량을 고려한 방사선치료계획에서 폐 선량이 많아지게 되는데, 본 연구는 비소세포 폐암 환자의 3차원입체조형치료(Three dimensional conformal radiotherapy, 3D CRT), 제한된 각도를 이용한 세기변조방사선치료(Intensity modulated radiotherapy, IMRT)와 용적변조회전치료(Volumetric Modulated Arc therapy, VMAT) 치료계획을 각각 적용하여 전체 폐 선량을 비교 및 평가하고자 한다. 대상 및 방법 : TrueBeam STx($Varian^{TM}$, USA) 10 MV 에너지를 이용하여 4명의 환자에 대하여 3D CRT, 제한된 각도를 이용한 IMRT와 VMAT 치료계획을 세우고, 총 선량 66 Gy/30 Fx 처방하였을 때, 선량용적히스토그램(Dose Volume Histogram, DVH)을 이용하여 치료계획용적(Planning Target Volume, PTV), 전체 폐 그리고 척수에 들어가는 선량을 평가하였다. PTV에 대한 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity index, HI), 처방선량포함지수(Paddick's Conformity Index, PCI)를 구하고, 폐의 30 Gy 용적($V_{30}$), $V_{20}$, $V_{10}$, $V_5$, 평균선량(Mean dose)을 평가하고, 척수의 최대선량 값을 평가하였다. 결 과 : PTV에 대한 CI, HI, PCI의 평균값은 각각 $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$으로 평가되었다. 전체 폐에 대한 첫 번째 환자의 $V_{20}$은 3D CRT, IMRT, VMAT 각각 30.7%, 20.2%. 21.2%, 두 번째 환자의 $V_{20}$은 33.0%, 29.2%. 31.5%, 세 번째 환자의 $V_{20}$은 51.3%, 34.3%. 36.9%, 네 번째 환자의 $V_{20}$은 56.9%, 33.7%. 40%로 제한된 각도를 이용한 IMRT 치료계획에서 가장 낮게 평가되었다. 척수에 대한 최대선량 값은 모두 허용선량 미만으로 평가되었다. 결 론 : 비소세포 폐암의 방사선치료계획에서 3D CRT와 비교했을 때, 제한된 각도를 이용한 IMRT나 VAMT을 이용하면 척수의 허용선량을 넘지 않으면서 폐 선량을 줄여줄 수 있는 치료계획을 세울 수 있었다. IMRT와 VAMT을 비교해보면 PTV의 선량포함과 척수선량을 고려했을 때 IMRT 치료계획에서 보다 좁은 각도를 이용한 치료계획이 가능하였고, 이는 폐 선량을 좀 더 줄여줄 수 있는 결과를 얻을 수 있었다.

비소세포폐암 III, IV기 환자에 있어서 Shell-Type Pseudo Target을 이용한 세기 조절 방사선치료계획기법의 유용성 평가 (Assessment of the Usefulness of an IMRT Plan Using a Shell-Type Pseudo Target with Patients in Stage III or IV of NSCLC)

  • 이상봉;박기주;박두찬;김만우;김준곤;노성환
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.95-106
    • /
    • 2012
  • 목 적: 비소세포폐암(Non-Small Cell Lung Cancer, NSCLC) III, IV기 환자의 방사선 치료 시 Shell-Type Pseudo Target의 유무에 따른 IMRT 치료계획의 유용성을 알아보고자 한다. 대상 및 방법: NSCLC III, IV기 환자 22명을 대상으로 Shell-Type Pseudo Target이 있을 때와(SPT) Shell-Type Pseudo Target이 없을 때(WSPT) 각각의 세기변조방사선치료(Intensity-Modulated Radiation Therapy, IMRT)계획을 세운 후, 선량-체적 히스토그람(Dose-Volume Histogram, DVH) 분석을 통해 종양 표적 내의 균일성 지수(Homogeneity Index, HI), 종양 표적에 대한 선량조형 지수(Conformity Index, CI), 척수 최대선량(Spinal Cord Maximum Dose), 식도에 대한 $V_{50%}$, 평균 폐 선량(Mean Lung Dose, MLD), 폐에 대한 $V_{40%}$ $V_{30%}$ $V_{20%}$ $V_{10%}$ $V_{5%}$ 등의 선량학적인 비교를 통해서 평가하였다. 결 과: WSPT와 SPT에 따른 각각의 CI 값은 평균 $1.22{\pm}0.04$, $1.16{\pm}0.032$ (.000*), HI 값은 평균 $1.06{\pm}0.015$, $1.07{\pm}0.014$ (.000*)로 나타났으며, CI 값은 SPT의 경우에서 각각의 차이 값에 대한 평균은 $-5.16{\pm}2.54%$의 감소를 보였으며, HI 값은 SPT의 경우에서 평균 $0.81{\pm}0.47%$ 증가된 것으로 나타났다. 식도에 대한 $V_{50%}$에서는 각각 $14.54{\pm}12.01%$ (WSPT), $12.14{\pm}11.09%$ (.000*, SPT)로 SPT에서 차이 값에 대한 평균이 $-26.37{\pm}25.05%$ 감소되었고, 척수 최대선량에서도 평균 선량이 각각 $3,898.44{\pm}1,075.0$ cGy (WSPT), $3,810.8{\pm}1,134.9$ cGy (.004*, SPT)로 SPT의 경우 평균 $-3.36{\pm}5.81%$ 감소되었다. 폐에 대한 $V_{X%}$에서는 $V_{5%}$, $V_{10%}$의 경우 차이 값에 대한 평균이 $-1.62{\pm}2.29%$ (.006*), $-1.98{\pm}5.02%$ (.005*)로 SPT의 경우에서 감소됨을 보여 주었고, 마찬가지로 $V_{20%}$, $V_{30%}$, $V_{40%}$에서도 각각 $-3.51{\pm}3.07%$ (.000*), $-4.84{\pm}6.01%$ (.000*), $-6.16{\pm}8.46%$ (.001*)로 SPT 경우에서 통계학적으로 유의함을 보이면서 감소한 것으로 나타났다. MLD의 평가에서도 SPT의 경우에서 평균 $-2.83{\pm}2.41%$ (.000*)의 감소를 보여주었으며, 이는 평균 169 cGy (Max: 547 cGy, Min: 6.4 cGy)의 처방선량을 SPT 사용 시 올릴 수 있는 결과를 보여주었다. 결 론: NSCLC III, IV기 환자의 방사선 치료 시 SPT를 이용한 IMRT 치료계획이 정상 폐에 들어가는 방사선량을 줄임으로 인해 방사선치료로 유발되는 폐렴의 위험을 감소시킬 수 있을 거라 생각되고, 또한 얼마간의 처방선량 증가로 인한 방사선치료 국소제어실패율을 감소시키는 동시에 치료효과를 증대 시킬 수 있을 것이라 사료된다.

  • PDF