• Title/Summary/Keyword: 0-back Task

Search Result 45, Processing Time 0.027 seconds

Effects of $40\%$ Oxygen on 2-back Task: Changes of Cognitive Performance and Physiological Signals ($40\%$ 농도의 산소 공급이 2-back 과제 수행에 미치는 영향: 인지 능력 및 생리 신호의 변화)

  • Chung Soon-Cheol;Park Ha-Ra;Lee Bongsoo;Tack Gye-Rae;Yi Jeong-Han;Eom Jin-Sup;Sohn Jin-Hun
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.3
    • /
    • pp.189-197
    • /
    • 2005
  • In this study, changes in performance of 2-back task, blood oxygen saturation and heart rate due to $40\%$ concentration oxygen supply were observed. Five male $(25.8\pm1.3)$ and five female $(23.0\pm1.0)$ college students were nked to perform 2-bark task during two types of oxygen (concentration $21\%,\;40\%$) administration. The experimental sequence consisted of Rest1(1 min.), 0-back Task (1 min.), 2-bark Task (2 min.), and Rest2 (4 min.) and the physiological signals such as blood oxygen saturation and heart rate were measured throughout the stages. The experimental result showed that the performance increased significantly at $40\%'s$ concentration of oxygen rather than $21\%'s$, which shows oxygen supply has positive influence on cognitive performance. When $40\%$ concentration oxygen is supplied, the oxygen saturation in the blood increased and heart rate was decreased significantly comparing to $21\%$. It is Suggested that $40\%$ oxygen can stimulate brain activation bY increasing actual blood oxygen concentration in the process of cognitive performance, and hyperoxia makes heart rate decrease.

  • PDF

Changes in Electrophysiological Activation Due to Different Levels of Cognitive Load (인지부하의 정도에 따른 뇌신경생리학적 변화)

  • Kwon, Joo-Hee;Kim, Euijin;Kim, Jeonghui;Im, Chang-Hwan;Kim, Do-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.52-60
    • /
    • 2022
  • Purpose: For now, cognitive load is assessed based on survey-based methods, which can be difficult to track the amount of cognitive load in real-time. In this study, we investigated the difference in electrophysiological activation due to different levels of cognitive load not only at sensor-level but also at source-level using electroencephalogram that might be potentially used for quantitative cognitive load evaluation. Materials and Methods: In this study, ten healthy subjects (mean age 24.3 ± 2.1, three female) participated the experiment. All participants performed 4 sessions of n-back task in different difficulties: 0-, 1-, 2-, and 3-back during electroencephalogram recording. For sensor-level analysis, we calculated the event-related potential and event-related spectral perturbation while low resolution brain electromagnetic tomography (LORETA) to estimate the source activation. Each result was compared between different workload conditions using statistical analysis. Results: Statistical results revealed that the accuracy of the task performance was significantly different between different cognitive loads (p = 0.018). The post-hoc analysis confirmed that the accuracy of the 3-back task was significantly decreased compared to 1-back condition (p = 0.018), but not with 2-back condition (p = 0.180). ERP results showed that P300 target amplitude between 1-back and 3-back had a marginal difference in Cz (p = 0.059) and Pz(p = 0.093). A significant inhibition in Cz high-beta activation (p = 0.017) and decrease in source activation of right parahippocampal gyrus was found in 3-back condition compared to 1-back condition (p < 0.05). Conclusion: In this study, we compared the sensor- and source-level differences in electroencephalogram between different levels of cognitive load, that were found to be in line with the previous reports related to cognitive load evaluation. We expect that the outcome of the current study can be used as a feature to establish a quantitative cognitive load assessment system.

Effects of Cognitive Task on Stride Rate Variability by Walking Speeds (보행속도변화에 따른 인지 과제 수행이 보행수 변동성에 미치는 영향)

  • Choi, Jin-Seung;Yoo, Ji-Hye;Kim, Hyung-Shik;Chung, Soon-Cheol;Yi, Jeong-Han;Lee, Bong-Soo;Tack, Gye-Rae
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.323-331
    • /
    • 2006
  • The purpose of this study was to investigate the effect of performing a cognitive task during treadmill walking on the stride rate variability. Ten university students(age $24.0{\pm}0.25$, height $172{\pm}3.1cm$, weight $66{\pm}5.3kg$) were participated in dual task experiments which consist of both walking alone and walking with a cognitive task. Two-back task was selected for the cognitive task since it did not have learning effect during the experimental procedure.3D motion analysis system was used to measure subject's position data by changing walking speed with 4.8, 5.6, 6.4, 6.8, and 7.2 km/hr. Stride rate was calculated by the time between heel contact and heel contact. Accuracy rate of a cognitive task during walking, coefficient of variance, allometric scaling methods and Fano factor were used to estimated the stride rate variability. As the walking speed increased, accuracy rate decreased and the logarithmic value of Fano factor increased which showed the statistical difference. Thus it can be concluded that the gait control mechanism is distracted by the secondary attention focus which is the cognitive task ie. two-back task. Further study is needed to clarify this by increasing the number of subject and experiment time.

Prediction of Peak Back Compressive Forces as a Function of Lifting Speed and Compressive Forces at Lift Origin and Destination - A Pilot Study

  • Greenland, Kasey O.;Merryweather, Andrew S.;Bloswick, Donald S.
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.236-242
    • /
    • 2011
  • Objectives: To determine the feasibility of predicting static and dynamic peak back-compressive forces based on (1) static back compressive force values at the lift origin and destination and (2) lifting speed. Methods: Ten male subjects performed symmetric mid-sagittal floor-to-shoulder, floor-to-waist, and waist-to-shoulder lifts at three different speeds (slow, medium, and fast), and with two different loads (light and heavy). Two-dimensional kinematics and kinetics were captured. Linear regression analyses were used to develop prediction equations, the amount of predictability, and significance for static and dynamic peak back-compressive forces based on a static origin and destination average (SODA) backcompressive force. Results: Static and dynamic peak back-compressive forces were highly predicted by the SODA, with R2 values ranging from 0.830 to 0.947. Slopes were significantly different between slow and fast lifting speeds (p < 0.05) for the dynamic peak prediction equations. The slope of the regression line for static prediction was significantly greater than one with a significant positive intercept value. Conclusion: SODA under-predict both static and dynamic peak back-compressive force values. Peak values are highly predictable and could be readily determined using back-compressive force assessments at the origin and destination of a lifting task. This could be valuable for enhancing job design and analysis in the workplace and for large-scale studies where a full analysis of each lifting task is not feasible.

Correlation among Functional Leg Length Discrepancy, Muscle Activity, Muscle Contraction Onset Time and Vertical Ground Reaction Force during Simple Lifting Task

  • Jin, Ha Young;Han, Jin Tae
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.4
    • /
    • pp.175-180
    • /
    • 2022
  • Purpose: Leg length discrepancy causes the posture deformation, gait asymmetry, and lower back pain. The purpose of this study is to investigate the correlation among functional leg length discrepancy (FLLD), muscle activity, muscle contraction onset time and vertical ground reaction force (vGRF) during simple lifting task. Methods: Thirty-nine subjects participated in this study. FLLD was measured from the umbilicus to medial malleolus of left and right leg using a tape. The subjects performed to lift a 10 kg box from the floor to chest. The muscle activity and muscle contraction onset time of rectus abdominis, erector spinae and rectus femoris was measured using EMG system and vGRF was measured by two force plate. Pearson correlation was used to fine out the correlation among FDDL, muscle activity, muscle contraction onset time and vGRF during simple lifting task. Results: Correlation between FLLD and difference of muscle activity of short-long side was very high (r>0.9) during simple lifting task. Correlation between FLLD and difference of muscle contraction onset time of short-long side was very high (r>0.9) during simple lifting task. And correlation between FLLD and difference of vGRF of short-long side was high (r>0.7) during simple lifting task. Conclusion: This study suggests that there is high correlation between FLLD and muscle activity, muscle contraction onset time, and ground reaction force during simple lifting task. Therefore, FLLD could negatively affect the postural balance.

fMRI evidence of compensatory mechanisms during a verbal working memory task in individuals with alcohol use disorders (알코올 사용 장애자의 언어 작업 기억과 관련된 뇌의 보상 기전: fMRI 연구)

  • Park, Mi-Suk;Son, Seon-Ju;Park, Ji-Eun;Eum, Yeong-Ji;Kim, Suk-Hui;Yu, In-Gyu;Son, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.05a
    • /
    • pp.101-104
    • /
    • 2009
  • This study investigated compensatory mechanisms in the brain during a verbal working memory task among people with Alcohol Use Disorders (AUD). A total of 21 college male students participated in the study: eleven AUD participants and 10 normal controls. Study participants were asked to complete the Korean version of the Wechsler Adult Intelligence Scale-III (K-WAIS-III) prior to the fMRI experiment. Verbal 0-back and 2-back tasks were used to assess brain activities of the participants' verbal working memory. Brain scanning was performed on Siemens SONATA 1.5T Scanner while participants were performing the 0-back and 2-back tasks. Within the AUD group, participants with greater dependency to alcohol (based on DSM-IV criteria) in the past 1 year showed lower mean score on the 'Similarities' of the K-WAIS-III (r=-0.63, p<0.05, N=11). The more participants experienced alcohol withdrawal symptoms in the past 1 year, the lower the score they received on the K-WAIS-III 'Picture Arrangement' (r=-0.69, p<0.05, n=11). The fMRI regression results showed that individuals who present greater degree of alcohol dependency symptoms are likely to show greater brain activation in the bilateral middle frontal gyri (BA 9) during the verbal working memory task. The degree of alcohol withdrawal symptoms were associated with increased brain activation in the left superior and middle frontal gyri (BA8), left precentral gyrus (BA 6), and left inferior parietal lobule (BA 40). The study findings showed that the degree of alcohol abuse/dependence and withdrawal symptoms were associated with decreased cognitive function and increased activations in brain regions particularly important for abstract reasoning (BA 9), central executive (BA 9), or spatial storage (BA 40) during a working memory task. Therefore, these results could support previous studies suggesting that the neural system of people with ADD may adopt a brain compensatory mechanism to maintain normal level of cognitive functions.

  • PDF

Design of a physical layer of IEEE 802.15.4q TASK for IoT (IoT를 위한 IEEE 802.15.4q 기반 TASK 물리 계층 설계)

  • Kim, Sunhee
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.1
    • /
    • pp.11-19
    • /
    • 2020
  • IoT has been consistently used in various fields such as smart home, wearables, and healthcare. Since IoT devices are small terminals, relatively simple wireless communication protocols such as IEEE 802.15.4 and ISO 18000 series are used. In this paper, we designed the 802.15.4q 2.4 GHz TASK physical layer. Physical protocol data unit of TASK supports bit-level interleaving and shortened BCH encoding. It is spread by unique ternary sequences. There are four spreading factors to choose the data rate according to the communication channel environment. The TASK physical layer was designed using verilog-HDL and verified through the loop-back test of the transceiver. The designed TASK physical layer was implemented in a fpga and tested using MAXIM RFICs. The PER was about 0% at 10 dB SNR. It is expected to be used in small, low power IoT applications.

Investigation of job-related back injuries reported in the Pohang region (포항지역 사례를 중심으로 한 직업성 요통재해 현황 조사에 대한 고찰)

  • 최경임;정민근;민경록
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.91-97
    • /
    • 1996
  • This study is to analyze trends of back injuries reported for medical expense compensation in a territorial jurisdiction of Pohang regional office of Ministry of Labor. Back unjuries claimed in the Plhang region accounted for approximately 15% of all industrial accident and 0.96 billion won were spent to compensate for medical expenses in 1994. A majority of back injuries occurred in manufacturing, construction, and transportation, and, 98% of all back injuries during 1992-1994 were strain/sprain, herniated inter-vertebral dise(HIVD), and fracture. To achieve and effective back injury prevention, supplenentary reporting form should be provided to include the information about job description (e.g., weight of an object, task duration and working posture), employee's medical and work history, and working conditions.

  • PDF

Effects of the Frequency Band Pass Filter on the P300 Event-related Potential in the Working Memory (주파수 통과대역필터가 작업 기억 관련 사건관련전위 P300에 미치는 영향)

  • Park, Woongsik;Lee, Jeongwoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.2
    • /
    • pp.131-138
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.