• Title/Summary/Keyword: -energy-dispersive x-ray-

Search Result 1,064, Processing Time 0.036 seconds

Physiochemical analysis, toxicity test and anti-bacterial effect of practically detoxified sulfur (법제유황의 실용적 제조에 따른 물리 화학적 분석 및 독성, 항균 작용에 관한 연구)

  • In, Dong-Chul;Yu, Do-Hyeon;Park, Chul;Park, Jin-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.3
    • /
    • pp.197-205
    • /
    • 2012
  • Despite of a long history of the sulfur on the disease healing effect, there were limited ways of applying sulfur to animal and human. We have developed the detoxified sulfur (non toxic sulfur) method to make it practical and mass production possible through laboring for many years. This study practiced scanning electron microscope (SEM), Energy dispersive X-ray spectrometer (EDS) and secondary ion mass spectrometry (SIMS) analysis to investigate the physicochemical aspect of detoxified sulfur. We also performed the oral toxicity experiment to mice, and anti-bacterial test of the detoxified sulfur. Based on the SEM, EDS and SIMS results, the united particles in the mass form with the similar component intensity with the raw sulfur were observed, and hydrogen sulfide ion (HS-) component which is regarded as a toxic matter, was decreased after detoxification. Indeed, toxicity test on the mice (10 males, 10 females) showed no clinical, histopathological changes with the 5 times amount (2,500 mg/kg) of the actual doses. However, the male-mice showed decreased in body weight by 23.6%, 24.3% in the 7th, 14th day, respectively, after detoxified sulfur. Moreover, the female-mice administered the detoxified sulfur showed decreased in body weight by 28.7% (P<0.05) than that in the control group on the 14th day. The result of antibacterial test on the detoxified sulfur showed antibacterial effect (27%) to inhibit the growth of Staphylococcus aureus. It is shown that detoxified sulfur can be used as feed additive and has an affect on the farm perfomance.

Analysis of Pigment on Portraits of Sim Hui-su in Joseon Period (조선시대 심희수 초상화 채색 안료 분석)

  • Yun, Eun Young;Chang, Yeon Hee
    • Journal of Conservation Science
    • /
    • v.32 no.4
    • /
    • pp.571-578
    • /
    • 2016
  • This study analyzed the pigments used in two portraits of Sim Hui-su using scanning electron microscopy/energy dispersive spectroscopy(SEM/EDS), X-ray diffraction(XRD) analysis, and microscopic observation, and then compared the results to those from nondestructive analysis. It was estimated that cinnabar/vermilion and minium were used for the red pigment, azurite for the blue pigment, atacamite for the green pigment, and lead white for the white pigment. These results were compared to the pigments of six portraits with a similar format, full-length official-attire portraits from the $17-18^{th}$ century Joseon period. It was revealed that the composition of the pigments used in the portraits varied depending on the date of production. Iron oxide, another red pigment, was used in the $18^{th}$ century. As for the blue colorant, smalt was used in the late $18^{th}$ century, whereas it was absent until the early $18^{th}$ century.

Fabrication of Biogenic Antimicrobial Silver Nanoparticles by Streptomyces aegyptia NEAE 102 as Eco-Friendly Nanofactory

  • El-Naggar, Noura El-Ahmady;Abdelwahed, Nayera A.M.;Darwesh, Osama M.M.
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.4
    • /
    • pp.453-464
    • /
    • 2014
  • The current research was focused on the extracellular biosynthesis of bactericidal silver nanoparticles (AgNPs) using cell-free supernatant of a local isolate previously identified as a novel Streptomyces aegyptia NEAE 102. The biosynthesis of silver nanoparticles by Streptomyces aegyptia NEAE 102 was quite fast and required far less time than previously published strains. The produced particles showed a single surface plasmon resonance peak at 400 nm by UV-Vis spectroscopy, which confirmed the presence of AgNPs. Response surface methodology was chosen to evaluate the effects of four process variables ($AgNO_3$ concentration, incubation period, pH levels, and inoculum size) on the biosynthesis of silver nanoparticles by Streptomyces aegyptia NEAE 102. Statistical analysis of the results showed that the linear and quadratic effects of incubation period, initial pH, and inoculum size had a significant effect (p < 0.05) on the biosynthesis of silver nanoparticles by Streptomyces aegyptia NEAE 102. The maximum silver nanoparticles biosynthesis (2.5 OD, at 400 nm ) was achieved in runs number 5 and 14 under the conditions of 1 mM $AgNO_3$ (1-1.5% (v/v)), incubation period (72-96 h), initial pH (9-10), and inoculum size (2-4% (v/v)). An overall 4-fold increase in AgNPs biosynthesis was obtained as compared with that of unoptimized conditions. The biosynthesized silver nanoparticles were characterized using UV-VIS spectrophotometer and Fourier transform infrared spectroscopy analysis, in addition to antimicrobial properties. The biosynthesized AgNPs significantly inhibited the growth of medically important pathogenic gram-positive (Staphylococcus aureus) and gram-negative bacteria (Pseudomonas aeruginosa) and yeast (Candida albicans).

Synthesis of Magnesium Hydroxide and Surface Modification by Sorbitol Surfactants (수산화마그네슘의 합성과 솔비톨계 계면활성제를 이용한 표면개질)

  • Kang, Kuk-Hyoun;Hyun, Mi-Ho;Ryu, Kun-Sung;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.92-100
    • /
    • 2014
  • Hydrophobic magnesium hydroxide [$Mg(OH)_2$] was modified by hydrothermal method using non-ionic sorbitol surfactant with Span series. Mganesium chloride [$MgCl_2$] and sodium hydroxide [NaOH] were used for synthesis of $Mg(OH)_2$. Also non-ionic surfactant were added as a stabilizer, dispersant and surface modifier. Addition of non-ionic surfactant was favourable to obtain small sized $Mg(OH)_2$ particles with better dispersibility and hydrophobic property of $Mg(OH)_2$ particles. The obtained product were characterized by particle size analysis(PSA), scanning electron microscope(SEM), energy dispersive spectroscopy(EDS), x-ray diffraction(XRD) and fourier transform infrared spectroscopy(FT-IR). The results show that the product are prepared with this method has a well hydrophobic properties and dispersity compared with unmodified $Mg(OH)_2$ particles. The improve properties of surface modified $Mg(OH)_2$ particles were also verified by similarity synthesizing under slightly different conditions.

Effects of a bleaching agent on properties of commercial glass-ionomer cements

  • de Camargo, Fernanda Lucia Lago;Lancellotti, Ailla Carla;de Lima, Adriano Fonseca;Martins, Vinicius Rangel Geraldo;de Souza Goncalves, Luciano
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.32.1-32.11
    • /
    • 2018
  • Objectives: This study evaluated the effects of a bleaching agent on the composition, mechanical properties, and surface topography of 6 conventional glass-ionomer cements (GICs) and one resin-modified GIC. Materials and Methods: For 3 days, the specimens were subjected to three 20-minute applications of a 37% $H_2O_2$-based bleaching agent and evaluated for water uptake (WTK), weight loss (WL), compressive strength (CS), and Knoop hardness number (KHN). Changes in surface topography and chemical element distribution were also analyzed by energy-dispersive X-ray spectroscopy and scanning electron microscopy. For statistical evaluation, the Kruskal-Wallis and Wilcoxon paired tests (${\alpha}=0.05$) were used to evaluate WTK and WL. CS specimens were subjected to 2-way analysis of variance (ANOVA) and the Tukey post hoc test (${\alpha}=0.05$), and KH was evaluated by one-way ANOVA, the Holm-Sidak post hoc test (${\alpha}=0.05$), and the t-test for independent samples (${\alpha}=0.05$). Results: The bleaching agent increased the WTK of Maxxion R, but did not affect the WL of any GICs. It had various effects on the CS, KHN, surface topography, and the chemical element distribution of the GICs. Conclusions: The bleaching agent with 37% $H_2O_2$ affected the mechanical and surface properties of GICs. The extent of the changes seemed to be dependent on exposure time and cement composition.

Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use (치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동)

  • Kim, Won-Gi;Lee, Chung-Hwan;Chung, Chae-Heon;Choe, Han-Cheol
    • Journal of Surface Science and Engineering
    • /
    • v.43 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

Improvement of the Characteristics of PZT Thin Films deposited on LTCC Substrates (LTCC 기판상에 증착한 PZT 박막의 특성 향상에 관한 연구)

  • Hwang, Hyun-Suk;Kang, Hyun-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.245-248
    • /
    • 2012
  • In this paper, the optimized growing conditions of PZT thin films on low temperature co-fired ceramics (LTCC) substrates are studied. The LTCC technology is an emerging one in the fields of mesoscale (from 10 um to several hundred um) sensor and actuator against silicon based technology due to low cost, high yield, easy manufacturing of 3 dimensional structure, etc. The LTCC substrates with thickness of 400 um are fabricated by laminating 100 um green sheets using commercial power (NEG, MLS 22C). The Pt/Ti bottom electrodes are deposited on the LTCC substrates, then the growing conditions of PZT thin films using rf magnetron sputtering method are studied. The growing conditions are tested under various rf power and gas ratio of oxygen to argon. And the crystallization and ingredient of PZT films are analyzed by X-ray diffraction method (XRD) and energy dispersive spectroscopy (EDS). The optimized growing conditions of PZT thin films are rf power of 125W, Ar/O2 gas ratio of 15:5.

Performance Change of Application Devices Caused by Magnetorheological Particle Corrosion (자기유변 입자 부식에 따른 응용장치의 성능 변화)

  • Han, Young-Min;Choi, Seong-Cheol
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.193-199
    • /
    • 2016
  • MR(magnetorheological) devices for vehicle applications requires the consistent control performance and the reliable operation. However, the corrosion of iron particles consisting the MR fluid can significantly affect on MR properties. This paper presents an effect of the MR particle corrosion on the performance of MR fluids such as shear stress magnitude which is directly concerned with control performance. As a first step, MR particles are corroded by water-calcium chloride solution. The resulting MR particles are examined by scanning electron microscope (SEM) and their molar ratios are analyzed by the energy dispersive X-ray analysis (EDAX). By dispersing the corroded MR particles into silicone oil, the corroded MR fluid is synthesized for evaluation of MR effect change. A rotational viscometer is adopted to measure shear stress magnitude. Finally, it is demonstrated how much the corrosion affect on performances by comparing the normal MR fluid to the corroded MR fluid, from which performance investigation of the MR devices containing the corroded MR particles will be studied in the second phase of this study.

DETORQUE FORCE OF TiN-COATED ABUTMENT SCREW WITH VARIOUS COATING THICKNESS AFTER REPEATED CLOSING AND OPENING

  • Kim, Han-Su;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.769-779
    • /
    • 2007
  • Statement of problem. When TiN coating is applied to the abutment screw, occurrence of greater preload and prevention of the screw loosening could be expected due to decrease of frictional resistance. However, the proper thickness of TiN coating on abutment screw has not been yet reported. Purpose. The purpose of this study is to find out the appropriate TiN coating thickness by evaluating the detorque force and the surface change of titanium abutment screw with various TiN coating thickness. Material and methods. 1. Material Thirty five non-coated abutment screws were prepared for TiN coating. TiN coatings were prepared by Arc ion plating method. Depending on the coating deposition time(CDT), experimental groups were divided into 6 groups(CDT 30min, 60min, 90min, 120min, 150min, 180min) and those of 1 group was not coated as a control group. Each group was made up of 5 abutment screws. 2. Methods FE-SEM(Field Emission Scanning Electron Microscoper) and EDX(Energy Dispersive X-ray Spectroscopy) were used to observe the surface of the abutment screw. Electric scales was used to measure the weight of the abutment screw after the repeated closing and opening of 10 trials. Detorque force was measured with digital torque gauge, at each trial. Results. 1. As the coating deposition time increased, the surface became more consistent and smooth. 2. As for the abutment screws that were TiN coated for more than 60 minutes, no surface change was found after the repeated closing and opening. 3. The TiN coated abutment screws showed less weight change than the non-coated abutment screws. 4. The TiN coated abutment screws showed higher mean detorque force than the noncoated abutment screws. 5. The abutment screw coated for 60 minutes showed the highest mean detorque force. Conclusion. The coating layer of proper thickness is demanded to obtain consistent and smooth coating surface, resistance to wear, and increased detorque force of the abutment screw. In conclusion, the coating deposition time of 60 minutes indicated improved mechanical property, when TiN coating was conducted on titanium abutment screw.

Conduction Properties of NitAI Ohmic Contacts to AI-implanted p-type 4H-SiC (AI 이온 주입된 p-type 4H-SiC에 형성된 Ni/AI 오믹접촉의 전기 전도 특성)

  • Joo, Seong-Jae;Song, Jae-Yeol;Kang, In-Ho;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Lee, Yong-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.717-723
    • /
    • 2009
  • Ni/Al ('/' denotes deposition sequence) contacts were deposited on Al-implanted 4H-SiC for ohmic contact formation, and the conduction properties were characterized and compared with those of Ni-only contacts. The thicknesses of the Ni and Al thin film were 30 nm and 300 nm, respectively, and the films were sequentially deposited bye-beam evaporation without vacuum breaking. Rapid thermal anneal (RTA) temperature was varied as follows : $840^{\circ}C$, $890^{\circ}C$, and $940^{\circ}C$. The specific contact resistivity of the Ni contact was about $^{\sim}2\;{\pm}\;10^{-2}\;{\Omega}{\cdot}cm^2$, However, with the addition of Al overlayer, the specific contact resistivity decreased to about $^{\sim}2\;{\pm}\;10^{-4}\;{\Omega}{\cdot}cm^2$, almost irrespective of RTA temperature. X-ray diffraction (XRD) analysis of the Ni contact confirmed the existence of various Ni silicide phases, while the results of Ni/Al contact samples revealed that Al-contaning phases such as $Al_3Ni$, $Al_3Ni_2$, $Al_4Ni_3$, and $Ab_{3.21}Si_{0.47}$ were additionally formed as well as the Ni silicide phases. Energy dispersive spectroscopy (EDS) spectrum showed interfacial reaction zone mainly consisting of Al and Si at the contact interface, and it was also shown that considerable amounts of Si and C have diffused toward the surface. This indicates that contact resistance lowering of the Ni/Al contacts is related with the formation of the formation of interfacial reaction zone containing Al and Si. From these results, possible mechanisms of contact resistance lowering by the addition of Al were discussed.