• Title/Summary/Keyword: 히트율

Search Result 115, Processing Time 0.026 seconds

A Study of Application on the Pulsating Heat Pipe for Heat Transfer Enhancement of Metal Hydride Alloy (수소 저장합금층의 열전달 촉진을 위한 진동형 히트 파이프 적용에 관한 연구)

  • Lee, Min-Jae;Im, Yong-Bin;Bae, Sang-Chul;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.346-351
    • /
    • 2006
  • When metallic alloys are reacted to hydrogen, heat transfer of storage tank effects hydrogen storage rate and capacity. If pulsating heat pipe are used to improve heat transfer efficiency, production of hydrogen storage tank can be more simple and economical. Experiment of heat pipe was conducted by varying working fluids and heat flux. According to supply heat flux, test indicate that R-22 and R-l42b were found lower temperature difference between evaporator and condenser than R-134a and Ethanol. Thermal resistances of R-22 and R-142b were also lower than others. Using R-142b as a working fluid, heat pipe type hydrogen storage tank is tested in absorption and desorption processes.

  • PDF

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

Fuzzy Relevance-based Transcoding for Differentiated Streaming Media Service in the Proxy System (프록시 시스템에서 차별화된 스트리밍 미디어 서비스를 위한 퍼지 적합도 기반 트랜스 코딩)

  • Lee, Chong-Deuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2785-2792
    • /
    • 2011
  • Such problems as delay, congestion, and crosstalk in the proxy system degrade not only QoS (Quality of Service) but responsiveness and reliability of the streaming media service. To solve this problem this paper proposed a FRTP (Fuzzy Relevance-based Transcoding Proxy) mechanism. The proposed FRTP mechanism analyzes fuzzy similarity for partitioned segment versions of media objects to create a FRTG (Fuzzy Relevance-based Transcoding Graph). Created FRTG determines the transcoding for partitioned media object segment versions. Determined transcoding improves DSR (Delay Saving Ratios), CHPR (Cache Hit Precision Ratio), and CHRR (Cache Hit Recall Ratio). The proposed mechanism is simulated to evaluate such performance parameters as DSR, CHPR, and CHRR. Simulation results shows that the proposed mechanism outperforms in DSR, CHPR and CHRR compared with the other existing mechanisms.

Web Caching Strategy based on Documents Popularity (선호도 기반 웹 캐싱 전략)

  • Yoo, Hae-Young;Park, Chel
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.29 no.9
    • /
    • pp.530-538
    • /
    • 2002
  • In this paper, we propose a new caching strategy for web servers. The proposed algorithm collects on]y the statistics of the requested file, for example the popularity, when a request arrives. And, at times, only files with higher popularity are cached all together. Because the cache remains unchanged until the cache is made newly, web server can use very efficient data structure for cache to determine whether a file is in the cache or not. This increases greatly tile efficiency of cache manipulation. Furthermore, the experiment that is performed with real log files built by web servers shows that the cache hit ratio and the cache hit ratio are better than those produced by LRU. The proposed algorithm has a drawback such that the cache hit ratio may decrease when the popularity of files that is not in the cache explodes instantaneously. But in our opinion, such explosion happens infrequently, and it is easy to implement the web servers to adapt them to such unusual cases.

Proxy Caching Grouping by Partition and Mapping for Distributed Multimedia Streaming Service (분산 멀티미디어 스트리밍 서비스를 위한 분할과 사상에 의한 프록시 캐싱 그룹화)

  • Lee, Chong-Deuk
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.1
    • /
    • pp.40-47
    • /
    • 2009
  • Recently, dynamic proxy caching has been proposed on the distributed environment so that media objects by user's requests can be served directly from the proxy without contacting the server. However, it makes caching challenging due to multimedia large sizes, low latency and continuous streaming demands of media objects. To solve the problems caused by streaming demands of media objects, this paper has been proposed the grouping scheme with fuzzy filtering based on partition and mapping. For partition and mapping, this paper divides media block segments into fixed partition reference block(R$_f$P) and variable partition reference block(R$_v$P). For semantic relationship, it makes fuzzy relationship to performs according to the fixed partition temporal synchronization(T$_f$) and variable partition temporal synchronization(T$_v$). Simulation results show that the proposed scheme makes streaming service efficiently with a high average request response time rate and cache hit rate and with a low delayed startup ratio compared with other schemes.

CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump (지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축)

  • Lee, Geon-Woo;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.349-354
    • /
    • 2008
  • August 2008, Our country was announced the Energy Vision 2030 for strengthening response capability climate change by the greenhouse effect, 'Stable supply of energy' and 'Efficient systems'. According to the report, Our country is the world's top 10 is a country that consumes a lot of energy. and more than 97% of the energy because it is dependent on foreign imports, The importance of NRE(New and Renewable Energy) is rising significantly, This paper was applied geothermal heat pump it one kind of the renewable energy equipment, in General buildings, and analyzed the effect of the installation. Thus, to improve the load factor of the Electric power system was proposed, and As a result, can be expected the energy cost savings and the reduction of greenhouse gases, through Economic electric power supply.

  • PDF

Development of Facility for Curing and Low Temperature Storage of Onion (양파 예건.저온저장 겸용기계장치 개발)

  • 김영민;김유호;윤홍선;최희석;조광환
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.280-286
    • /
    • 2003
  • 양파의 예건 및 저온저장에 소요되는 노동력 절감과 저장시 발생하는 부패율을 감소시키기 위하여 양파를 한 곳에서 예건과 저온저장할 수 있는 양파 예건ㆍ저온저장 겸용 기계장치를 제작하여 예건 및 저온저장 성능시험을 실시하였다. 주요 연구 결과를 요약하면 다음과 같다. 가 예건과 저온저장을 한 곳에서 할 수 있는 양파 예건ㆍ저온저장 겸용 기계장치는 히트펌프를 이용하여 저장고내의 온도와 습도를 조절할 수 있도록 제작하였다. 나. 예건시 설정온도가 38$^{\circ}C$, 저온저장시 설정온도가 $0^{\circ}C$일 때 온도분포의 표준편차는 각각 0.51, 0.12로 나타났다. 다. 설정온도 및 상대습도를 각각 38$^{\circ}C$, 65%RH로 예건시험을 실시한 결과, 예건 시간은 52시간 소요되었고, 감모율은 0.99-l.79%로 나타났다. 라. 설정온도를 $0^{\circ}C$, 70%RH로 저온저장한 결과, 저장고의 온도는 -0.5-1.5$^{\circ}C$, 저장고의 습도는 70-80%로 나타났다. 마. 관행(자연예건)방법과 시작기로 예건한 양파로 저온저장시험을 실시한 결과, 저장기간 중 감모율은 저장초기부터 일정하게 증가는 경향으로 나타났고, 저장후 20일부터 차이가 나타나기 시작하였으며, 150일 시점에서는 평균 3.16% 차이가 나타났다. 바 저장 중 부패율은 관행의 방법으로 예건한 양파에서 42일째부터 발생하기 시작하여 지속적으로 증가하였고, 시작기로 예건한 양파는 저장후 90일까지는 부패된 양파가 없는 것으로 나타났다.

  • PDF

Theoretical Analysis of Heat Transportation Limitation by Porosity of Wick in Screen Mesh Wick Heat Pipe (스크린메쉬윅 히트파이프에서 윅의 기공율변화에 따른 열수송한계의 이론적 고찰)

  • Lee, Ki-Woo;Park, Ki-Ho;Chun, Won-Pyo;Lee, Wook-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1-6
    • /
    • 2003
  • The purpose of the present study is to investigate the capillary heat transportation limitation in heat pipe according to the change of screen mesh wick porosity. Diameter of pipe was 6 mm, and mesh numbers are 100, 150, 200 and 250 and water was selected as a working fluid. According to the change of wick porosity and mesh number, the capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, and capillary heat transportation limitation are analyzed by theoretical design method of a heat pipe. As some results, the capillary heat transportation limitation in screen mesh wick heat pipe is largely affected by wick porosity and mesh number.

  • PDF

ANALYSIS OF HEAT TRANSFER PERFORMANCE WITH ASPECT AND FILLING RATIOS IN THERMOSYPHON (열사이펀의 형상비와 충전율에 따른 열전달 성능 해석)

  • Kim, Y.C.;Choi, J.W.;Kim, S.C.
    • Journal of computational fluids engineering
    • /
    • v.20 no.1
    • /
    • pp.92-98
    • /
    • 2015
  • Thermal-fluid analysis is performed numerically to figure out the characteristics of heat transfer in a thermosyphon varying with the aspect ratio of geometry and the filling ratio of working fluid. The computational results are reasonable compared with the experimental data and visualized. The thermal resistance and the convective heat transfer coefficients are evaluated with the aspect ratio of thermosyphon and the filling ratio of working fluid, respectively. In conclusion, the thermal resistance decreases as the length of evaporator increases. However, the variation of a condenser length is nearly independent on the thermal resistance. In order to raise the performance of thermosyphon, the working fluid needs to be filled over 75%. In addition, Nusselt numbers in the evaporator and the condenser show 275 and 304, respectively.

Manufacturing and Operating Performance of the Heat Pipe with Sintered Wick (소결윅 히트파이프의 제작 및 작동성능)

  • Yun, Ho-Gyeong;Moon, Seok-Hwan;Ko, Sang-Choon;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1260-1266
    • /
    • 2002
  • In this study, to make an excellent heat pipe, the manufacturing technology of a sintered wick was investigated. Making a sintered wick is known to be very difficult but it has many advantages. For example, the porosity and pore size can be controlled and the capillary force is great. The mixture of copper and pore former powder was used as a wick material and ceramic-coated stainless steel was used as a mandrel which is necessary for vapor flow. To analyze the feature of the manufactured wick, not only porosity and pore size were measured but also the sintered structure was observed. A heat pipe with sintered wick was manufactured and the performance test of the heat pipe was performed in order to review cooling performance. The performance test results for the 4mm diameter heat pipe with the sintered wick shows the stability since the temperature difference between a evaporator and a condenser of the heat pipe is less than 4.4$^{\circ}C$, and thermal resistance is less than 0.7$^{\circ}C$/W, In the meantime the composite wick that is composed with sintered and woven wire was also examined. The heat transfer limit of the heat pipe with composite wick was enhanced about 51%~60% compare to the one with sintered wick.