• 제목/요약/키워드: 흉부 후.전 방사선검사

Search Result 79, Processing Time 0.021 seconds

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF

Optimal Height of Shielding Plate of Radiation in Posteroanterior Chest Radiography for Pregnant Women on Korea (한국인 임산부의 흉부 후-전 방향 방사선검사 시 적절한 차폐막 높이)

  • Joo, Young-Cheol;Kim, Gyoo-Hyung
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.97-102
    • /
    • 2018
  • The purpose of this study is to provide the basic data for reducing unnecessary radiation dose to the abdomen and fetus of pregnant women by presenting proper height of shielding protector for efficient abdominal shielding in chest PA examination of Korean pregnant women. The subjects of this study were 288 persons who were eligible for this study among 798 pregnant women who had chest PA examination from January 1, 2015 to December 31, 2016 Retrospective study was performed. Measurements was performed from the apex of the right and left lungs to costophrenic angle of the right and left lungs and to the lowest costophrenic angle among the right and left lungs at the top of the image(this line called Joo's line in this study). The mean of the right and left lung height of pregnant women were 259.09 mm and 263.57 mm, respectively. Also, the average height of the Joo's line designed by the researcher for proper abdominal radiation protection was 322.15 mm. For proper and efficient abdominal radiation protection for pregnant women, it is necessary to adjust the shielding according to the height of the pregnant woman. It is appropriate that the height of the shielding protector should be adjusted so that the upper part of the shield is located at 342.30 mm below from upper part of the detector.

Serial Determinations of Serum Squamous Cell Carcinoma Antigen (SCC) during Radiotherapy for Uterine Cervix Cancer (자궁경부암에서 방사선치료 중 혈중 Squamous Cell Carcinoma Antigen 값의 변화)

  • Yun, Hyong-Geun;Park, Seok-Kun
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.136-141
    • /
    • 2001
  • Purpose : To evaluate the significance of serum SCC for the monitoring of treatment response and the early detection of distant metastasis during radiotherapy (RT). Materials and Methods : In 13 patients with histologically proven primary squamous cell carcinoma of uterine cervix, serum SCC values were checked in pre-RT point, weekly during RT, and in post-RT point. Results : In 4 of 13 cases, metastasis appeared at the end of external RT, so that intracavitary radiation couldn't be peformed.01 these 4 cases,3 with elevated pre-RT SCC level, who resulted in lung metastasis on chest PA at the end of external RT showed decreased post-RT SCC value despite of metastasis. Of all 10 cases with elevated pre-RT SCC value (including 3 with metastasis at the end of external RT), SCC value was higher than pre-RT value in 7 at 9 Gy and the difference was statistically significant. At 18 Gy, SCC was higher in 4 and lower in 6 than pre-RT value. After 18 Gy, SCC value decreased continuously to the end of RT in all 10 cases. Conclusion : During RT, SCC value increased initially at 9 Gy. To 18 Gy, SCC value decreased to the nearly same with pre-RT value. After 18 Gy, to the end of RT, SCC value decreased continuously and normalized in completely responded cases. In cases with appearance of lung metastasis, SCC value also decreased with the disappearance of main mass of uterine cervix despite metastasis.

  • PDF

Postirradiation Changes of White Blood Cells and Lymphocyte Subpopulations in Cancer Patients (암환자의 방사선치료에서 흉부 및 전골반강 조사직후 백혈구 및 림프구아헝 변화에 대한 연구)

  • Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun;Nah, Byung-Sik;Noh, Young-Hee
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • Purpose : Radiation-induced alteration in the immune function is well known phenomenon in cancer patients. Our purpose is to evaluate the extent of immune suppression immediately after mediastinal or pelvic irradiation, which include significant volume of active bone marrow in adults. Materials and Methods'48 cancer patients with mediastinal(N=29) and pelvic irradiation(N=19) were the basis of this analysis. Age ranged from 36 to 76 and mean and median value was 57 years, respectively Sex ratio was 1.3(M: F=27/21). The immunological parameters were the complete blood cell(CBC) with differential cell(D/C) count, T cell subset(CD3, CD4, CD8 CDl9), NK cell test(CDl6, CD56), and serum immunoglobulin(IgG, IgA, IgM) level. Results : The mean value of white blood cell(WBC) was reduced from 7017 to 4470 after irradiation(p=0.0000). In the differential count, the number of lymphocyte, neutrophil, and basophil was markedly reduced with statistical significance(p<0.01) and the number of monocyte was not changed and, on the contrary, that of eosinophil was increased by irradiation. In the lymphocyte subpopulation analysis, the number of all subpopulations, CD3(T cell), CD4(helper T cell), CD8(suppressor T cell), CDl6(NK cell), CDl9(B, cell) was reduced with statistical significance. The mean ratio of CD4 to CD8 in all patients was 1.09 initially and reduced to 0.99 after radiotherapy(p=0.34) , but the proportional percentage of all subpopulations was not changed except CD19(B cell) after irradiation. In the immunoglobulin study, initial values of Ig G, Ig A, and Ig M were relatively above the normal range and the only Ig M was statistically significantly reduced after radiotherapy(p=0.02). Conclusion : Mediastinal and pelvic irradiation resulted in remarkable suppression of lymphocyte count in contrast to the relatively good preservation of other components of white blood cells. But the further study on the functional changes of lymphocyte after radiotherapy may be necessary to conclude the effects of the radiation on the immunity of the cancer Patients.

  • PDF

Clinical Implication of Malignant Pleural Lavage Cytology (PLC) in Primary Lung Cancer (원발성 폐암에서 악성 흉강 세척액의 임상적 의미)

  • 김용희;박승일;김동관;공경엽
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.252-260
    • /
    • 2004
  • The purpose of study is to evaluate the clinical implication of malignant Pleural Lavage Cytology (PLC) in primary lung cancer. 315 patients were examined with pleural lavage cytology in Asan Medical Center between November 1998 and August 2002. The patients were chosen from primary lung cancer patients with no pleural effusion according to preoperative radiologic examination; no tumor invasion into the chest wall and no diffuse pleural adhesion in intraoperative findings, The pleural cavity and lung were washed with 100 $m\ell$ of warm normal saline. The 315 patients consisted of 237 men and 78 women. The incidence of malignant PLC was found in 28 patients (8.9%). For patients in early stages (I & II), survival rate was 93.9% in positive malignant PLC and 85.7% in negative malignant PLC. 31 patients (13.6%) had local or distant recurrences; 2-year recurrence-free rate was 90.1% in negative PLC and 87.5% in positive PLC. The survival and recurrence-free rate in each stage were not statistically associated with the result of PLC. Median follow-up was 16.4 months from the surgery. To access implication of malignant PLC in primary lung cancer, a long-term follow-up and further study are required.

Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy (유방암 절제술 후 방사선치료를 시행한 환자의 골스캔에서 보이는 방사전 유발 늑골골절)

  • Kim, Hae-Won;Won, Kyoung-Sook;Zeon, Seok-Kil;Kim, Jin-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.287-293
    • /
    • 2009
  • Purpose: This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Materials and Methods: Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest a findings of rib fracture were analyzed. Results: The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p = 0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p =0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest a, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p = 0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p = 0.001). Conclusion: Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

Research on ANIOS Disinfection Efficiency to Prevent Infection in Radiography Room (방사선촬영실 감염 방지를 위한 에니오설프의 소독효율 연구)

  • Jung, Woo-Chan;Ahn, Ki-Song;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.55-61
    • /
    • 2021
  • In this study, microbes were collected before and after disinfection using ANIOS(ANIOSURF Premium NPC) and compared the areas where the radiological technologist and the patient frequently contacted the chest X-ray. From September 1st to September 7th, 2020. in P Hospital in Deagu, 4 region were collected in a 10×10 size using a sterile cotton swab of the transport medium, and before and after disinfection results were obtained through the colorimetric method. As a result, n the X-ray tube handle Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp., Candida spp., and in the Chin region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM, and in the Chest region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, and in the Palm region NTM, Candida spp. were detected, and 103 CFU(Colony Forming Unit) or more were measured. After disinfection, only X-ray tube handle was detect Bacillus spp. and more than 102 CFU was measured. Microorganisms found prior to disinfection can cause opportunistic infections, Experimental results showed that Aniosulf(0.25%) is more economical and disinfectant than ethanol(70-90%) and isopropyl alcohol(70-90%). However, further research is needed on the detection of Bacillus spp. resultingly this research is useful basic data of infection control in Radiography room and prevention secondary infections.

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.