• Title/Summary/Keyword: 회전각도

Search Result 590, Processing Time 0.043 seconds

Analysis of Variations in Deformations of Additively Manufactured SUS316L Specimen with respect to Process Parameters and Powder Reuse (금속 적층제조 방식을 이용한 SUS316L 시편의 공정 파라미터 및 금속 분말 재사용에 따른 변형량 변화 분석)

  • Kim, Min Soo;Kim, Ji-Yoon;Park, Eun Gyo;Kim, Tae Min;Cho, Jin Yoen;Kim, Jeong Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.4
    • /
    • pp.223-231
    • /
    • 2022
  • Residual stress that can occur during the metal additive manufacturing process is an important factor that must be properly controlled for the precise production of metal parts through 3D printing. Therefore, in this study, the factors affecting these residual stresses were investigated using an experimental method. For the experiment, a specimen was manufactured through an additive manufacturing process, and the amount of deformation was measured by cutting it. By appropriately calibrating the measured data using methods such as curve fitting, it was possible to quantitatively analyze the effect of process parameters and metal powder reuse on deformation due to residual stress. From this result, it was confirmed that the factor that has the greatest influence on the magnitude of deformation due to residual stress in the metal additive manufacturing process is whether the metal powder is reused. In addition, it was confirmed that process parameters such as laser pattern and laser scan angle can also affect the deformation.

Evaluation of Power Generation Efficiency according to Geometric Characteristics of Reservoir in Micro Vortex Hydro-electric Power Generation System (마이크로 보텍스 수력발전시스템에 있어 저수조의 기하학적 특성에 따른 발전 효율 평가)

  • Jeong, Woo Chang;Kang, Hyun Sil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.432-432
    • /
    • 2021
  • 우리나라는 대부분의 에너지 공급을 해외에 의존하고 있는 실정이다. 산업통상자원부와 에너지경제연구원에서 발간하는 2018년 에너지통계연보(에너지경제연구원과 산업통상자원부, 2018)에 실린 2010년부터 2017년까지의 에너지수급 균형을 보면 원유, 천연가스, 석탄, 우라늄 등 평균 95.4%의 에너지를 수입하고 있는 실정이다. 수력 및 신재생에너지의 경우 기후변화에 대응하는 수단 그리고 정부의 저탄소에너지 전환 정책으로 인정받아 상대적으로 낮은 에너지 경제성에도 불구하고 꾸준히 보급되고 있다. 우리나라뿐만 아니라 독일, 프랑스, 영국, 중국 그리고 인도와 같은 세계 주요 국가들이 친환경 에너지 정책을 주도함에 따라 향후 신재생에너지의 공급 규모는 크게 확대될 것으로 전망된다. 중력 물 보텍스 마이크로 수력 발전 시스템은 시스템의 상하류부의 수두(hydraulic head) 차에 의해 저류조(basin)에서 발생되는 물의 보텍스 즉 소용돌이(whirlpool)를 이용하여 임펠러(impeller)를 회전시켜 전기에너지를 생산하는 친환경적 재생에너지의 일종이다. 또한, 시스템으로 유입되는 물은 전기에너지 생산을 위한 임펠러를 통과한 후 다시 하천으로 방류되므로 하천 수의 손실 그리고 하천의 물길도 거의 교란 시키지 않는다. 4가구 정도의 연간 가정용 전기 요구량인 12와 15kW 사이의 전기에너지를 생산하기 위해서는 발전시스템의 상류와 하류의 수두차가 단지 1.5에서 1.7m 이하이면 충분한 것으로 알려져 있다. 본 연구에서는 중력 물 보텍스 친환경 마이크로 발전 시스템을 구성하는 저류조(basin)에 대해 최대 발전효율을 발생시키기에 최적인 기하학적 형태를 도출하는 것이며, 이를 위해 저류조의 cone angle에 따른 다양한 저류조 직경 및 물 보텍스 생성을 위한 저류조 형태의 변화, 유입수로와 저류조와의 각도인 notch angle의 변화, 유입부 폭과 유출부 직경, 유입수로의 길이 그리고 유입수로에서의 초기수심과 같은 기하학적 매개변수를 변화시켜 모의를 수행하였다.

  • PDF

Buckling Load and Mode Analysis of Symmetric Multi-laminated Cylinders with Elliptical Cross-section (다층 대칭배열된 타원형 적층관의 좌굴하중 및 모드해석)

  • Chun, Kyoung Sik;Son, Byung Jik;Ji, Hyo Seon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.457-464
    • /
    • 2006
  • Fiber-reinforced composite materials due to their high specific strength, high stiffness and light weight are becoming increasingly used in many engineering industry, especially in the aerospace, marin and civil, etc. In this paper, the buckling load and mode shapes of composite laminates with elliptical cross-section including transverse shear deformations are analyzed. For solving this problems, a versatile flat shell element has been developed by combining a membrane element with drilling degree-of-freedom and a plate bending element. Also, an improved shell element has been established by the combined use of the addition of enhanced assumed strain and the substitute shear strain fields. The combined influence of shell geometry and elliptical cross-sectional parameter, fiber angle, and lay-up on the buckling loads of elliptical cylinder is examined. The critical buckling loads and mode shapes analyzed here may serve as a benchmark for future investigations.

Development of Geometric Calibration Method for Triple Head Pinhole SPECT System (삼중헤드 SPECT에서 기하학적 보정 기법의 개발)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Won-Woo;Park, So-Yeon;Son, Ji-Yeon;Kim, Yu-Kyeong;Kim, Sang-Eun;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Purpose: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the SPECT image with good image quality. We developed a simplified geometric calibration method for rotating triple-head pinhole SPECT system and assessed the effects of the calibration using several phantom and rodent imaging studies. Materials and Methods: Trionix Triad XLT9 triple-head SPECT scanner with 1.0 mm pinhole apertures were used for the experiments. Approximately centered point source was scanned to track the angle-dependent positioning errors. The centroid of point source was determined by the center of mass calculation. Axially departed two point sources were scanned to calibrate radius of rotation from pinhole to center of rotation. To verify the improvements by the geometric calibration, we compared the spatial resolution of the reconstructed image of Tc-99m point source with and without the calibration. SPECT image of micro performance phantom with hot rod inserts was acquired and several animal imaging studies were performed. Results: Exact sphere shape of the point source was obtained by applying the calibration and axial resolution was improved. Lesion detectibility and image quality was also much improved by the calibration in the phantom and animal studies. Conclusion: Serious degradation of micro-pinhole SPECT images due to the geometric errors could be corrected using a simplified calibration method using only one or two point sources.

Changes in atlas position with Class ll activator treatment in Class II malocclusion patients (II급 부정교합자에서 액티베이터 사용에 따른 atlas의 위치 변화에 관한 연구)

  • Cho, Moon-Ki;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.44-55
    • /
    • 2007
  • Objective: Previous studies have reported that morphological features of the first cervical vertebra (atlas) have been associated with mandibular growth direction. The purpose of this study was to show the possible positional and morphological changes of the Atlas from activator treatment in Class II malocclusion patients. Methods: Lateral cephalometric radiograph tracings were made at initial, middle and final stages of treatment. Angular and linear measurements of skeletal and morphological features were measured on the anatomical landmarks and reference planes. Results: The skeletal effects of activator treatment on Class II malocclusion patients were evident on ramal height, body length, effective body length, ANB, and overjet. Clockwise rotation of the long axis of the Atlas was found in Group 1, but there was no inclination change of the Atlas in groups 2 and 3. There was no significant correlation between anterior and posterior positions of the atlas or morphological change in all groups. - except for posterior movements of the Atlas found in group 1. Conclusion: Clockwise rotation of the atlas axis resulted from activator treatment in Cl II malocclusion patients. Change in atlas axis can be thought of as an indicator for success of activator treatment.

Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report - (상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고-)

  • Ji, Jong-Hoon;Kim, Young-Yul;Park, Sang-Eun;Ra, Ki-Hang;Do, Jeong-Hun;Kim, Weon-Yoo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the clinical result of arthroscopic treatments by using suture anchors or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture. Materials and Methods: From March 2004 to March 2006 we have used suture anchor or suture anchors combined with cannulated screw for 6 cases of the greater tuberosity fracture which include displaced fractures, comminuted fractures and minimally displaced fractures with comcomittent lesions such as rotator cuff tears, stiffness and labral lesion. In this retrospective study, we analyzed the clinical outcomes by using the range of motion, University of California at Los Angeles shoulder rating scale (UCLA) and the ASES shoulder index score (ASES) in the average 6 months follow up. Results: At the last follow up, average range of motion was improved to 154.3 degree, 145.8 degree, 32.6 degree and L1 vertebrae in each forward flexion, abduction, external rotation and internal rotation. Clinically the UCLA rating scales improved to 31.5 and the ASES shoulder index score (ASES) improved to 93.6 in the last follow up. Conclusion: Arthroscopic treatments by using suture anchor or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture is an alternative treatment of the greater tuberosity fracture of the proximal humerus fracture.

  • PDF

Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON (한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션)

  • Bae, Jae-Beom;Cho, Byung-Cheol;Kwak, Jung-Won;Park, Woo-Yoon;Lim, Young-Kyung;Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The purpose of the Monte Carlo simulation study was to provide the optimized nozzle design to satisfy the beam conditions for biomedical researches in the Korean heavy-ion accelerator, RAON. The nozzle design was required to produce $C^{12}$ beam satisfying the three conditions; the maximum field size, the dose uniformity and the beam contamination. We employed the GEANT4 toolkit in Monte Carlo simulation to optimize the nozzle design. The beams for biomedical researches were required that the maximum field size should be more than $15{\times}15cm^2$, the dose uniformity was to be less than 3% and the level of beam contamination due to the scattered radiation from collimation systems was less than 5% of total dose. For the field size, we optimized the tilting angle of the circularly rotating beam controlled by a pair of dipole magnets at the most upstream of the user beam line unit and the thickness of the scatter plate located downstream of the dipole magnets. The values of beam scanning angle and the thickness of the scatter plate could be successfully optimized to be $0.5^{\circ}$ and 0.05 cm via this Monte Carlo simulation analysis. For the dose uniformity and the beam contamination, we introduced the new beam configuration technique by the combination of scanning and static beams. With the combination of a central static beam and a circularly rotating beam with the tilting angle of $0.5^{\circ}$ to beam axis, the dose uniformity could be established to be 1.1% in $15{\times}15cm^2$ sized maximum field. For the beam contamination, it was determined by the ratio of the absorbed doses delivered by $C^{12}$ ion and other particles. The level of the beam contamination could be achieved to be less than 2.5% of total dose in the region from 5 cm to 17 cm water equivalent depth in the combined beam configuration. Based on the results, we could establish the optimized nozzle design satisfying the beam conditions which were required for biomedical researches.

Development of an Automatic Grafting Robot for Fruit Vegetables using Image Recognition (영상인식 기술 이용 과채류 접목로봇 개발)

  • Kang, Dong Hyeon;Lee, Si Young;Kim, Jong Koo;Park, Min Jung;Son, Jin Kwan;Yun, Sung-Wook
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.322-327
    • /
    • 2019
  • This study was conducted to improve the performance of automatic grafting robot using image recognition technique. The stem diameters of tomatoes and cucumber at the time of grafting were $2.5{\pm}0.3mm$ and $2.2{\pm}0.2mm$ for scions and $3.1{\pm}0.7mm$ and $3.6{\pm}0.3mm$ for rootstocks, respectively. The grafting failure was occurred when the different height between scions and rootstocks were over 4 mm and below 2 mm due to the small contact area of both cutting surface. Therefore, it was found that the height difference at the cutting surface of 3 mm is appropriate. This study also found that grafting failure was occurred when the stem diameters of both scions and rootstocks were thin. Therefore, it was suggested to use at least one stem with thicker than the average stem diameter. Field survey on the cutting angle of stems by hand were ranged from 13 to 55 degree for scions and 15 to 67 degree for rootstocks, respectively, which indicates that this could cause the grafting failure problem. However, the automatic grafting robot developed in this study rotates the seedlings 90 degree and then the stems are cut using a cutting blade. The control part of robot use all images taken from grafting process to determine the distance between a center of both ends of stem and a gripper center and then control the rotation angle of a gripper. Overall, this study found that The performance of automatic grafting robot using image recognition technique was superior with the grafting success rates of cucumber and tomato as $96{\pm}3.2%$ and $95{\pm}4%$, respectively.

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF