• Title/Summary/Keyword: 활동도계수

Search Result 50, Processing Time 0.027 seconds

Calculation of the Activity Coefficients of Ions in Weak Electrolyte Solutions (묽은 전해질용액에서 이온의 활동도계수 계산)

  • Lee, Man-Seung;Son, Seong Ho
    • Resources Recycling
    • /
    • v.27 no.5
    • /
    • pp.9-13
    • /
    • 2018
  • The equilibrium constant of a chemical reaction is related to the standard Gibbs free energy change. Since equilibrium constant is defined as the ratio of the activities of the chemical species, it is necessary to consider the non-ideal behavior of the solutes as ionic strength of the solution increases. In this paper, the derivation of Debye-$H{\ddot{u}}ckel$ limiting law and its modification by which the activity coefficient of an ion can be calculated was explained. Moreover, the method to obtain the activity coefficient of an ion from the experimentally determined mean activity coefficients of an electrolyte was explained.

A Systematic Review on Accelerometer to Measure Activity of Daily Living of Patients with Stroke (뇌졸중 환자의 일상생활활동 평가도구인 가속도계에 대한 체계적 고찰)

  • Lee, Joo-Hyun;Park, Jin-Hyuck;Kim, Yeonju;Park, Hae Yean;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.2
    • /
    • pp.57-69
    • /
    • 2016
  • Objective: The purpose of this study was to systematically review the articles using accelerometer to measure activity of daily living of patients with stroke. Methods: Depending on selection criteria, 13 studies were searched for PubMed, EMBASE, and Cochrane library database from February 2014 to March 2014. A total of 331 papers were searched, and 13 of these were selected. Results: In studies of 13 selected, acute, subacute, and chronic patients with stroke were enrolled. The kind of accelerometer was uniaxial, biaxial, and triaxial, activity monitor. Measurement activities were mainly arm activity, walking activity, and attachment sites were also various depending on the measurement activities. A measured variable was the total number of activities, the movement speed of the patients, ratio between affected and non-affected, and motion analysis. The result indicated that significant correlation with the other assessment tools in all studies. Conclusions: Accelerometer will be applied with a tool for measuring activity of daily living of patients with stroke, depending on activities characteristics. Further, we need accelerometer studies to apply with a variety of assessment in clinical practice or community settings.

Modeling and Measurements of the Activity Coefficients and Solubilities of Amino Acids in the L-valine/electrolyte and L-proline/electrolyte Aqueous Solutions (L-Valine/전해질 및 L-Proline/전해질 수용액에서 아미노산의 활동도계수와 용해도의 측정 및 모델링)

  • Lee, Bong-Seop;Kim, Ki-Chang
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.93-105
    • /
    • 2012
  • Activity coefficients and solubilities of L-Valine and L-Proline in aqueous solutions containing each of four electrolytes such as NaCl, KCl, $NaNO_3$ and $KNO_3$ were measured at 298.15 K. The measurements of activity coefficients were carried out in the electrochemical cell coupled with two ion-selective electrodes (cation and anion), and the solubilities were measured by the gravimetric analysis of saturated solutions in equilibrium with the solid phase of amino acid. The measured activity coefficients of electrolytes and amino acids were correlated with the theoretical thermodynamic model presented in the previous work [Korean Chem. Eng. Res. 48(4), 519(2010)]. It was found that the activity coefficients of amino acids and electrolytes described based on the our previous model were well agreeable with experimental data. Also the experimental solubility data of L-Valine and L-Proline were successfully correlated with the thermodynamic relation mentioned in the previous work.

Measurements and Modeling of the Activity Coefficients and Solubilities of L-alanine in Aqueous Electrolyte Solutions (전해질 수용액에서 L-Alanine의 활동도계수와 용해도의 측정 및 모델링)

  • Lee, Bong-Seop;Kim, Ki-Chang
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.519-533
    • /
    • 2010
  • Activity oefficients and solubilities of L-Alanine in aqueous solutions containing each of four electrolytes(NaCl, KCl, $NaNO_3$ and $KNO_3$) were measured at 298.15 K. The measurements of activity coefficients were carried out in the electrochemical cell coupled with two ion-selective electrodes(cation and anion), and the solubilities were measured by the gravimetric analysis of saturated solutions in equilibrium with the solid phase of L-alanine. To model the activity coefficients and solubilities of amino acid in the amino acid/electrolyte aqueous solutions, thermodynamic relations of the residual Helmholtz free energy in the amino acid/electrolyte aqueous solutions were developed based on the perturbed-chain statistical associating fluid theory(PC-SAFT) combined with the primitive mean spherical approximation(primitive-MSA). In the present model, it is assumed that the zwitterions of L-alanine are associated with each other and cross-associated with water molecules, and also cross-associated with the cation and anion dissociated from an electrolyte(inorganic salt). The activity coefficients and solubilities of L-Alanine calculated from the theoretical model proposed in this work are found to be well agreeable with experimental data.

Precise Control of Nutrient Solution and Analysis of Ionic Contribution to EC Reading (양액의 정밀 제어 및 이온의 EC 기여도 분석)

  • Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.352-354
    • /
    • 1998
  • A soilless culture system with the precise control of nutrient solution was developed and the time changes of ionic contribution to EC reading was analyzed. The measuring device designed was able to wash electrodes cleanly and to measure the pH and EC of nutrient solution stably in the box. The nutrient supply system using metering device was also able to control the EC and pH within ${\pm}0.05mS/cm$ and ${\pm}0.05$, respectively. Under the EC control, activity coefficients of all ions decreased with time as ionic concentrations of $SO_4$, Mg and Ca increased due to the selective nutrient absorption by plants. Time changes of ionic contribution to EC reading could be calculated using equivalent ionic conductivities and activity coefficients obtained by numerical analysis.

  • PDF

A Comparative Analysis of Bilateral Hand Movement Using Accelerometer : A Pilot Study (가속도계를 이용한 양손 움직임 비교분석: 예비연구)

  • Lee, Joo-Hyun;Yang, No-Yul
    • Therapeutic Science for Rehabilitation
    • /
    • v.2 no.2
    • /
    • pp.61-66
    • /
    • 2013
  • Objective : The purpose of this study was to analysis of disparity between bilateral hand movement when performing activity of daily living using accelerometer. Methods : The subjects of this study included 6 healthy adults. The assessment tool used Jebsen Hand Function Test and accelerometer. The subjects performed 7 sub-tests after wearing accelerometer around wrist. Results : Among sub-tests, writing was the only significantly correlated with difference between dominant and non-dominant hand(t=-2.394, p<.05). Further, non-dominant hand (M=2476.2, SD=802.2) showed more movement than dominant hand(M=1456.2, SD=667.6). Conclusion : This results indicated that accelerometer is useful tool for assessment of bilateral hand movement. Considering demographic characteristics, various subject group, further study is needed.

A Comparative Study on the Prediction of Vapor-Liquid Equilibria for the Ethanol-Benzene Mixture between Equation of State Model and Liquid Activity Coefficient Model (비이상적 상거동을 보이는 이성분계 혼합물의 기액 상평형 추산을 위한 상태방정식과 액체 활동도계수 모델 사이의 비교연구)

  • Cho, Jung-Ho;Lee, Ji-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1747-1753
    • /
    • 2010
  • In this study, a comparative study was performed to predict the vapor-liquid equilibria with maximum azeotropic pressure for ethanol-benzene binary system between an equation of state model and a liquid activity coefficient model. Peng-Robinson equation of state model with a Panatiotopoulos mixing rules (PRP) was used and NRTL liquid activity coefficient model proposed by Renon was selected. The PRP model, even though it has only two binary adjustable parameters, was not inferior to the NRTL model to predict vapor-liquid equilibria for low pressure region of ethanol-benzene system and showed a better prediction capability for high pressure region of ethanol-benzene system than the NRTL model with three binary interaction parameters.

Ionic Equilibria in $ZnSO_4-Na_2SO_4-H_2SO_4-NaOH-H_2O$ System ($ZnSO_4-Na_2SO_4-H_2SO_4-NaOH-H_2O$계의 이온 평형)

  • 이만승;박현주;나춘기
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2002
  • For $ZnSO_4$-$Na_2$$SO_4$-$H_2$ $SO_4$-$NaOH-H_2$O system, pH of solutions with different electrolyte concentrations was measured at $25^{\circ}C$ and ionic equilibria were analyzed by using K-value method. Activity of water and activity coefficients of solutes were calculated by Pitzer equation. The equilibrium concentration and activity coefficients of solutes were calculated from initial experimental conditions. At high ionic strength of 4m, the pH values calculated were in good agreement with those measured. In the experimental ranges of ionic strength of solution from 3.5 to 4.3 m, the mean activity coefcient of $ZnSO_4$calculated agreed well with those obtained from literature.

Energy expenditure of physical activity in Korean adults and assessment of accelerometer accuracy by gender (성인의 13가지 신체활동의 에너지 소비량 및 가속도계 정확성의 남녀비교)

  • Choi, Yeon-jung;Ju, Mun-jeong;Park, Jung-hye;Park, Jong-hoon;Kim, Eun-kyung
    • Journal of Nutrition and Health
    • /
    • v.50 no.6
    • /
    • pp.552-564
    • /
    • 2017
  • Purpose: The purpose of this study was to measure energy expenditure (EE) the metabolic equivalents (METs) of 13 common physical activities by using a portable telemetry gas exchange system ($K4b^2$) and to assess the accuracy of the accelerometer (Actigraph $GT3X^+$) by gender in Korean adults. Methods: A total of 109 adults (54 males, 55 females) with normal BMI (body mass index) participated in this study. EE and METs of 13 selected activities were simultaneously measured by the $K4b^2$ portable indirect calorimeter and predicted by the $GT3X^+$ Actigraph accelerometer. The accuracy of the accelerometer was assessed by comparing the predicted with the measured EE and METs. Results: EE (kcal/kg/hr) and METs of treadmill walking (3.2 km/h, 4.8 km/h and 5.6 km/h) and running (6.4 km/h) were significantly higher in female than in male participants (p < 0.05). On the other hand, the accelerometer significantly underestimated the EE and METs for all activities except descending stairs, moderate walking, and fast walking in males as well as descending stairs in females. Low intensity activities had the highest rate of accurate classifications (88.3% in males and 91.3% females), whereas vigorous intensity activities had the lowest rate of accurate classifications (43.6% in males and 27.7% in females). Across all activities, the rate of accurate classification was significantly higher in males than in females (75.2% and 58.3% respectively, p < 0.01). Error between the accelerometer and $K4b^2$ was smaller in males than in females, and EE and METs were more accurately estimated during treadmill activities than other activities in both males and females. Conclusion: The accelerometer underestimated EE and METs across various activities in Korean adults. In addition, there appears to be a gender difference in the rate of accurate accelerometer classification of activities according to intensity. Our results indicate the need to develop new accelerometer equations for this population, and gender differences should be considered.

Comparison of Experimental Data on the Fluctuation Integral Gij with the Calculated Results Based on the Activity Coefficient Model in Binary Mixtures Containing c-Hexane (c-hexane을 포함하는 이성분계 혼합물에서 활동도계수 모델을 이용한 변동적분 Gij의 계산 수치와 실험 수치의 비교)

  • Hur, Kwang-II;Kwon, Yong-Jung
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.203-209
    • /
    • 2000
  • The fluctuation integrals which give useful information in the structure of solution are associated with the mixed direct correlation integral ($C_{12}$) known. Using its weighted arithmetic mean of $C_{11}$ and $C_{22}$ and the activity coefficient model, the fluctuation integrals on solute-solute, solvent-solute, and solvent-solvent can be calculated in the function of mole fraction. In this work, several binary mixtures containing c-hexane were tested and the results on the fluctuation integrals were rather good.

  • PDF