• Title/Summary/Keyword: 환경잡음

Search Result 1,912, Processing Time 0.034 seconds

Optimum Rake Processing for Multipath Fading in Direct-Sequence Spread-Spectrum Communication Systems (주파수대역 직접확산 통신시스템에서 다중경로 페이딩 보상을 위한 최적 레이크 신호처리에 관한 연구)

  • 장원석;이재천
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10C
    • /
    • pp.995-1006
    • /
    • 2003
  • It is well know that in the wireless communication systems the transmitted signals can suffer from multipath fading due to the wave propagation characteristics and the obstacles over the paths, resulting in serious reduction in the power of the received signals. However, it is possible to take advantage of the inherent diversity imposed in the multipath reception if the underlying channel can be properly estimated. One of the diversity reception methods in this case is Rake processing. In this paper we study the Rake receivers for the direct-sequence spread-spectrum communication systems utilizing PN (pseudo noise) sequences to achieve spread spectrum. A conventional Rake receiver can use the finite-duration impulse (FIR) filter followed by the PN sequence demodulator, where the FIR filter coefficients are the reverse-ordered complex conjugate values of the fading channel impulse response estimates. Here, we propose a new Rake processing method by replacing the aforementioned PN code sequence with a new set of optimum demodulator coefficients. More specifically, the concept of the new optimum Rake processing is first introduced and then the optimum demodulator coefficients are theoretically derived. The performance obtained using the new optimum Rake processing is also calculated. The analytical results are verified by computer simulation. As a result, it is shown that the new optimum Rake processing method improves the MSE performance more than 10 dB over the conventional one using the fixed PN sequence demodulator. It is also shown that the new optimum Rake processing method improves the MSE performance about 10 dB over the Adaptive Correlator that performs the combining of the multipath components and PN demodulation concurrently. And finally, the MSE performance of the optimum Rake demodulator is very close to the MSE performance of OPSK demodulator under the AWGN channel.

Super Resolution Algorithm Based on Edge Map Interpolation and Improved Fast Back Projection Method in Mobile Devices (모바일 환경을 위해 에지맵 보간과 개선된 고속 Back Projection 기법을 이용한 Super Resolution 알고리즘)

  • Lee, Doo-Hee;Park, Dae-Hyun;Kim, Yoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • Recently, as the prevalence of high-performance mobile devices and the application of the multimedia content are expanded, Super Resolution (SR) technique which reconstructs low resolution images to high resolution images is becoming important. And in the mobile devices, the development of the SR algorithm considering the operation quantity or memory is required because of using the restricted resources. In this paper, we propose a new single frame fast SR technique suitable for mobile devices. In order to prevent color distortion, we change RGB color domain to HSV color domain and process the brightness information V (Value) considering the characteristics of human visual perception. First, the low resolution image is enlarged by the improved fast back projection considering the noise elimination. And at the same time, the reliable edge map is extracted by using the LoG (Laplacian of Gaussian) filtering. Finally, the high definition picture is reconstructed by using the edge information and the improved back projection result. The proposed technique removes effectually the unnatural artefact which is generated during the super resolution restoration, and the edge information which can be lost is amended and emphasized. The experimental results indicate that the proposed algorithm provides better performance than conventional back projection and interpolation methods.

A Study on Linkage Integration Control System Using Power Line Communication(PLC) and Wireless Sensor Network(WSN) (전력선 통신과 무선 센서 네트워크 기술을 이용한 연동 통합제어 시스템에 관한 연구)

  • Ji, Yun-il;Lim, Kang-il;Park, Kyung-sub
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.733-736
    • /
    • 2009
  • Power Line Communication(PLC) is need not additional communication line. So establishment expense is inexpensive and application is simple. Therefore, lower part network of various application field is possible. However, there are high subordinate interference and noise problem on limited transmission data and communication interference element. Wireless Sensor Network(WSN) is need not infrastructure, Self-regulating network architecture of sensor nodes is possible. So at short time, network construction is available. But, power consumption is increased by active sensing for QoS elevation and unnecessary information transmission, low electric power design and necessity of improve protocol are refered to life shortening problem and is studied. In this paper, supplement problem of power line communication and wireless sensor network mutually and because advantage becomes linkage integration control system using synergy effect of two technologies as more restriction be and tries to approach structurally control network that is improved for smooth network environment construction. Honeywell's hybrid sensor network does comparative analysis(benchmarking). Confirm performance elevation proposing teaming of power line communication and wireless sensor network. Through simulation, service delay decreases and confirms that performance elevation.

  • PDF

Installation of Very Broadband Seismic Stations to Observe Seismic and Cryogenic Signals, Antarctica (남극 지진 및 빙권 신호 관측을 위한 초광대역 지진계 설치)

  • Lee, Won-Sang;Park, Yong-Cheol;Yun, Suk-Young;Seo, Ki-Weon;Yee, Tae-Gyu;Choe, Han-Jin;Yoon, Ho-Il;Chae, Nam-Yi
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.3
    • /
    • pp.144-149
    • /
    • 2012
  • Korea Polar Research Institute (KOPRI) has successfully installed two autonomous very broadband three-component seismic stations at the King George Island (KGI), Antarctica, during the 24th KOPRI Antarctic Summer Expedition (2010 ~ 2011). The seismic observation system is originally designed by the Incorporated Research Institutions for Seismology Program for Array Seismic Studies of the Continental Lithosphere Instrument Center, which is fully compatible with the Polar Earth Observing Network seismic system. The installation is to achieve the following major goals: 1. Monitoring local earthquakes and icequakes in and around the KGI, 2. Validating the robustness of seismic system operation under harsh environment. For further intensive studies, we plan to move and install them adding a couple more stations at ice shelf system, e.g., Larsen Ice Shelf System, Antarctica, in 2013 to figure out ice dynamics and physical interaction between lithosphere and cryosphere. In this article, we evaluate seismic station performance and characteristics by examining ambient noise, and provide operational system information such as frequency response and State-Of-Health information.

Validation of Sea Surface Wind Estimated from KOMPSAT-5 Backscattering Coefficient Data (KOMPSAT-5 후방산란계수 자료로 산출된 해상풍 검증)

  • Jang, Jae-Cheol;Park, Kyung-Ae;Yang, Dochul
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1383-1398
    • /
    • 2018
  • Sea surface wind is one of the most fundamental variables for understanding diverse marine phenomena. Although scatterometers have produced global wind field data since the early 1990's, the data has been used limitedly in oceanic applications due to it slow spatial resolution, especially at coastal regions. Synthetic Aperture Radar (SAR) is capable to produce high resolution wind field data. KOMPSAT-5 is the first Korean satellite equipped with X-band SAR instrument and is able to retrieve the sea surface wind. This study presents the validation results of sea surface wind derived from the KOMPSAT-5 backscattering coefficient data for the first time. We collected 18 KOMPSAT-5 ES mode data to produce a matchup database collocated with buoy stations. In order to calculate the accurate wind speed, we preprocessed the SAR data, including land masking, speckle noise reduction, and ship detection, and converted the in-situ wind to 10-m neutral wind as reference wind data using Liu-Katsaros-Businger (LKB) model. The sea surface winds based on XMOD2 show root-mean-square errors of about $2.41-2.74m\;s^{-1}$ depending on backscattering coefficient conversion equations. In-depth analyses on the wind speed errors derived from KOMPSAT-5 backscattering coefficient data reveal the existence of diverse potential error factors such as image quality related to range ambiguity, discrete and discontinuous distribution of incidence angle, change in marine atmospheric environment, impacts on atmospheric gravity waves, ocean wave spectrum, and internal wave.

Intrusion Detection Method Using Unsupervised Learning-Based Embedding and Autoencoder (비지도 학습 기반의 임베딩과 오토인코더를 사용한 침입 탐지 방법)

  • Junwoo Lee;Kangseok Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.8
    • /
    • pp.355-364
    • /
    • 2023
  • As advanced cyber threats continue to increase in recent years, it is difficult to detect new types of cyber attacks with existing pattern or signature-based intrusion detection method. Therefore, research on anomaly detection methods using data learning-based artificial intelligence technology is increasing. In addition, supervised learning-based anomaly detection methods are difficult to use in real environments because they require sufficient labeled data for learning. Research on an unsupervised learning-based method that learns from normal data and detects an anomaly by finding a pattern in the data itself has been actively conducted. Therefore, this study aims to extract a latent vector that preserves useful sequence information from sequence log data and develop an anomaly detection learning model using the extracted latent vector. Word2Vec was used to create a dense vector representation corresponding to the characteristics of each sequence, and an unsupervised autoencoder was developed to extract latent vectors from sequence data expressed as dense vectors. The developed autoencoder model is a recurrent neural network GRU (Gated Recurrent Unit) based denoising autoencoder suitable for sequence data, a one-dimensional convolutional neural network-based autoencoder to solve the limited short-term memory problem that GRU can have, and an autoencoder combining GRU and one-dimensional convolution was used. The data used in the experiment is time-series-based NGIDS (Next Generation IDS Dataset) data, and as a result of the experiment, an autoencoder that combines GRU and one-dimensional convolution is better than a model using a GRU-based autoencoder or a one-dimensional convolution-based autoencoder. It was efficient in terms of learning time for extracting useful latent patterns from training data, and showed stable performance with smaller fluctuations in anomaly detection performance.

Correlation Between the Headphone's Acoustical Characteristics and Subjective Preferences (헤드폰의 음향적 특성과 주관적 선호도간의 상관 관계)

  • Lee, Ki-Seung;Lee, Seok-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.96-106
    • /
    • 2009
  • In this paper, correlation between the headphone's acoustical characteristics and the subjective preferences is analyzed, and a possibility of predicting the subjective preferences using the acoustical characteristics is investigated, The headphone's acoustical characteristics include the total harmonic distortions, the variation of the frequency response which were measured by separate channel and the inter-aural correlation coefficients, Those characteristics were measured in a noise-free anechoic chamber, using a head and torso simulator, The subjective preferences were scored in terms of loudness, clearness, spaciousness, fullness and overall impression, In the subjective listening test, 12 subjects were participated who have plentiful listening experiences, The programs include 5 kinds of musics; korean popular song, pop song, light music, male-voice and classic, The 8 models of the headphones were employed, including 4 closed-type circumaural headphones, 2 open-type supraaural headphones and 2 intra-concha headphones, A significant test was carred on the results from the subjective test, using a two-way ANOVA test, The correlation coefficients between the acoustical parameters and the subjective preferences were computed, Experimental results showed that the variation of the magnitude of frequency response measured from a right channel revealed higher correlation with the subjective preferences. Whereas the inter-aural correlation coefficients have very low correlation coefficients.

Performance Analysis of the Array Shape Estimation Methods Based on the Nearfield Signal Modeling (근거리 신호 모델링을 기반으로 한 어레이 형상 추정 기법들의 성능 분석)

  • Park, Hee-Young;Lee, Chung-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.221-228
    • /
    • 2008
  • To estimate array shape with reference sources in SONAR systems, nearfield signal modeling is required for the reference sources near a towed array. Array shape estimation method based on the nearfield signal modeling generally exploits the spatial covariance matrix of the received reference sources. Among those method, nearfield eigenvector method uses the eigenvector corresponding to the maximum eigenvalue as a steering vector of the reference source. In this paper, we propose a simplified subspace fitting method based on the nearfield signal modeling with spherical wave modeling. Furthermore, we analyze performance of the array shape estimation methods based on the nearfield signal modeling for various environments. The results of the numerical experiments indicate that the simplified subspace fitting method and the nearfield eigenvector method with single reference source shows almost similar performance. Furthermore, the simplified subspace fitting method with 2 reference sources consistently estimates the shape of the array regardless of the incident angle of the reference sources, whereas the nearfield eigenvector method cannot apply for the case of 2 reference sources.

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF