• 제목/요약/키워드: 환경건축

Search Result 4,153, Processing Time 0.035 seconds

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

A Comparative Study on Teachers' Satisfaction about High Schools Equipped with Excellent Facilities and with General Facilities -Focusing on high schools in Gyeonggi-do (우수시설 고등학교와 일반시설 고등학교의 시설에 대한 교원만족도 비교 연구 -경기도 소재를 중심으로-)

  • Cho, Kyung-Sik;Aigerim, Belyalova
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.12
    • /
    • pp.11-24
    • /
    • 2017
  • The purpose of this study is to offer fundamental data which is necessary to improve a design for the general high school. For doing this, teachers' satisfaction about using spaces of high schools equipped with excellent facilities and with general facilities respectively was compared and analyzed. Selected schools for this study were 3 high schools with superior facilities and 3 high schools with general facilities, all of which have been built or renovated since 2010. Data were collected by doing a field survey, a literature survey, and a questionnaire survey. Data were analyzed by 4 ways: Reliability analysis about satisfaction of educational facilities, demographic analysis, regression analysis on overall satisfaction and the use of facilities, and t-test to verify the difference of satisfaction depending on schools. Findings showed that overall satisfaction was high in high schools with excellent facilities whereas it was low in high schools with general facilities. Also, in order to enhance overall satisfaction of facilities, it suggests that building and continuously maintaining a circular route and a walkway which do not have the concealed space should be necessary.

Testing The Healing Environment Conditions for Nurses with two Independent Variables: Visibility Enhancement along with Shortening the Walking Distance of the Nurses to Patient - Focused on LogWare stop sequence and space syntax for U-Shape, L- Shape and I-Shape NS-

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.19-26
    • /
    • 2015
  • Purpose: Maximizing human comfort in design of medical environments depends immensely on specialized architects particularly critical care design; the study proposes Evidence-Based Design as an apparent analog to Evidence-Based Medicine. Healthcare facility designs are substantially based on the findings of study in an effort to design environments that augment care by improving patient safety and being therapeutic. On SPSS (Statistical Package for Social Science) t-test is applied to simulate two independent variables of PDR (Pre Design-Research) and POE (Post- Occupancy Evaluation). PDR is conducted on relatively new hospital Hallym University Dongtan Sacred Heart Hospital to analyse visibility from researchers' point of view, here the ICU is arranged in I-Shape. POE is applied on Dongguk University Ilsan Hospital to simulate walking on LogWare where two NS are designed based on L- Shape and Seoul St. Mary's Hospital, The Catholic University of Korea where five NS are functional for ICU Intensive Care Unit, Surgical Intensive Care Unit (SICU), Medical Intensive Care Unit (MICU), Critical Care Unit (CCU), Korean Oriental Medical Care Unit which are mostly arranged in U-Shape, and walking pattern is recognized to be in a zigzag path. Method: T-Test is applied on two dependent communication variables: walkability and visibility, with confidence interval of 95%. This study systematically analyses the Nurse Station (NS) typo-morphology, and simulates nurse horizontal circulation, by computing round route visits to patient's bed, then estimating minimum round route on LogWare stop sequence software. The visual connectivity is measured on depth map graphs. Hence the aim is to reduce staff stress and fatigue for better patients care by minimizing staff horizontal travel time and to facilitate nurse walk path and support space distribution by increasing effectiveness in delivering care. Result: Applying visibility graph and isovist field on space syntax on I- Shape, L- Shape and U- Shape ICU (SICU, MICU and CCU) configuration, I-shape facilitated 20% more patients in linear view as they stir to rise from their beds from nurse station compared to U-shape. In conclusion, it was proved that U-Shape supply minimum walking and maximum visibility; and L shape provides just visibility as the nurse is at pivot. I shape provides panoramic view from the Nurse Station but very rigorous walking.

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter (동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구)

  • Ryu, Ri;Seo, Jang-hoo;Kim, Yong-seong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

A Study on Deflection Characteristics of Plywood for Wood Based Flooring by Veneer Composition (마루판용 합판의 단판 구성요소에 따른 변형 특성에 관한 연구)

  • Pi, Duck-Won;Kang, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.42-50
    • /
    • 2013
  • Since 1990's, a plywood for flooring base has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as crossband layers was checked by deflection experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on deflection are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are M type of density gradient on the other hand Eucalyptus samples are W type of density gradient. The more samples have high density difference, the more deformation was checked. A sample which has big density difference between core and cross bands layer warp more also deform. Flooring was deformed smaller than plywood and samples which have big density difference was deformed more.

Effects of Types and Locational Characteristics of Urban Parks on the Apartment Price (도시공원의 유형 및 입지적 특성이 공동주택가격에 미치는 영향)

  • Lee, Go Eun;Choi, Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.927-936
    • /
    • 2016
  • This research aims to analyze the effect of different types of urban parks and their locational characteristics on the apartment price in the entire metropolitan area of Busan, Korea. Although an urban park is an environmental good that influences the surroundings in many ways, most of the previous studies have underestimated its impact on the value of the surrounding area. This research focuses on the economic value of urban parks by understanding their relationship with the value of the apartments in the surrounding area with its significance in their physical and objective characteristics. Furthermore, the research emphasizes the different typological characteristics of urban parks in the analysis. In summary of the result, the number of levels (stories) and units of the apartment complex, ranking of the contractor, age of a park and accessibility to sub-central are positively related to the price of apartment units. On the other hand, the total area of apartment complex, the age of apartments, the distance to the nearest park and accessibility to civic-central or regional district are negatively related to the price of apartment units. Having a plan for constructing a park is also positively related to the price. For the typological characters of a park, neighborhood park, small-sized park, and sports park are positively related to the price, while children's park is negatively related to the price of apartment units. Considering that the price increases as the distance to the nearest park decreases, people prefer to live near the benefits that urban parks provide. In order to maximize the value and benefits that parks provide, it is necessary to approach them creatively.

The Effectiveness of Accounting Information in Military Construction Contracts under the Qualification Assessment System (적격심사낙찰제 계약에서 회계정보의 유용성에 관한 연구)

  • Hur, Hyung
    • Journal of the military operations research society of Korea
    • /
    • v.37 no.1
    • /
    • pp.49-70
    • /
    • 2011
  • This paper re-evaluated the research on the accounting information's effectiveness in military construction contracts, questioning the former research results on the central army's construction contract that was under the Qualification Assessment System, especially concerning the relations between the accounting information and the bidding ratios as well as the relations between the bidding rates and the defect rates, which targeted between 1 to 10 billions civil engineering, construction, electricity, telecommunication, and environment work types. Unlike the previous results, the relationship between the accounting information and the bidding rates was shown to be considerably limited that the bidding ratio could not be identified through the accounting information, while it could discern the relations with the defect rates. Furthermore, the proven results did not support the hypothesis that the differences in bidding rates could affect the defect ratio. However, through the prediction model of bidding and defect ratios, we could identity the accounting variables that influenced the ratios. Additionally through the results regarding the non-financial indexes in the Pre-Qualification items, the weight on these indexes could be adjusted. In conclusion, the research results has given us new understanding of the problems in the Qualification Assessment System which accounts for the majority of the current military construction contracts and provide validity on the government's expanded implementation of the Lowest Price Award System.

Probabilistic Prediction of the Risk of Sexual Crimes Using Weight of Evidence (Weight of Evidence를 활용한 성폭력 범죄 위험의 확률적 예측)

  • KIM, Bo-Eun;KIM, Young-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.72-85
    • /
    • 2019
  • The goal of this study is to predict sexual violence crimes, which is an routine risk. The study used to the Weight of Evidence on sexual violence crimes that occurred in partly Cheongju-si for five years from 2011 to 2015. The results are as follows. First, application and analysis of the Weight of Evidence that considers the weight of evidence characteristics showed 8 out of total 26 evidences that are used for a sexual violence crimes risk prediction. The evidences were residential area, date of use permission for building, individual housing price, floor area ratio, number of basement floor, lot area, security light and recreational facility; which satisfied credibility in the process of calculating weight. Second, The weight calculated 8 evidences were combined to create the prediction map in the end. The map showed that 16.5% of sexual violence crimes probability occurs in 0.3㎢, which is 3.3% of the map. The area of probability of 34.5% is 1.8㎢, which is 19.0% of the map and the area of probability of 75.5% is 2.0㎢, which is 20.7% of the map. This study derived the probability of occurrence of sexual violence crime risk and environmental factors or conditions that could reduce it. Such results could be used as basic data for devising preemptive measures to minimize sexual violence, such as police activities to prevent crimes.

A Study on CO2 Emissions to Establish a LCI DB at the Disuse Stage (폐기단계에서 LCI DB구축을 위한 CO2 발생량에 관한 연구)

  • Choi, Doo-Sung;Park, Jin Jong;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.103-110
    • /
    • 2013
  • This study aims to calculate the $CO_2$ emissions by the properties of construction waste to establish a LCI DB of construction waste generated at the disuse stage. The $CO_2$ emissions from apartment houses was calculated by calculating the energy consumptions by treatment steps to calculate the $CO_2$ emissions by the treatment steps of construction waste. As a result of analyzing the $CO_2$ emissions from a total of 27 complexes, maximum 46,791g-$CO_2/m^2$, minimum 34,893g-$CO_2/m^2$ and average 38,713g-$CO_2/m^2$ were generated, and were varied by the quantity of construction waste in general, but were affected by the transportation distance in case of transportation steps as well. As a result of analyzing the $CO_2$ emissions by the properties of construction waste, average 19,815.50g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage in case of construction wastes, and 1.72g-$CO_2/m^2$ was generated, the lowest, during reclamation. In case of combustible waste, average 11,495.63g-$CO_2/m^2$ was generated, the highest, from the example complex during incineration of wastes, and 21.48g-$CO_2/m^2$ was generated, the lowest, at the waste transportation stage. In case of noncombustible waste, average 522.43g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage, and 1.07g-$CO_2/m^2$ was generated, the lowest, at the transportation stage. In case of other construction wastes, average 645.42g-$CO_2/m^2$ was generated, the highest, from the example complex at the demolition stage, and 47.38g-$CO_2/m^2$ was generated, the lowest, at the middle treatment stage.

Development of detachable air-cap module for improving the performance of windows (창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발)

  • Seo, Beomdong;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.