• Title/Summary/Keyword: 환경건축

Search Result 4,180, Processing Time 0.033 seconds

Health Enhancing Architectural Features of Modern Hanok Perceived by Apartment Residents (도시한옥의 건강특성에 대한 아파트 거주자의 인지 분석)

  • Jang, Mi-Seon;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.3-10
    • /
    • 2011
  • Recently, as sense of crisis about human survival has become serious due to worsening environmental pollution, people have begun to pay attention to their health more and more. In order to improve health conditions, multifarious approaches have been made from such diverse sectors as foods, clothing, medical sciences and environment, and particularly space environmental matters of housing cannot but be a matter of great concern to maintain and enhance the health of the residents. However, scarcely empirical studies have been made from the viewpoint of the users regarding the characteristics of Modern Hanok that has been appreciated as an example of a representative healthy housing. Therefore, this study aimed to study the recognition of apartment residents concerning the health characteristics of Modern Hanok. The health characteristics of Modern Hanok analyzed through literature investigation were classified into three categories of physical, mental and social health, and based on these characteristics, survey was made through web-survey upon 200 apartment residents who have interest in Hanok but have not lived or stayed in Hanok yet. The survey result revealed that about 60% of the respondents have recognized the health characteristics of Modern Hanok, and the respondents recognizing this fact expected that on a comparatively low average level of 2.09 out of 5 the health characteristics of Modern Hanok would affect their health. At current housing market where users' viewpoint and roles function more importantly than ever, the result of this study will contribute to enhance the comprehensive understanding about the health characteristics of Modern Hanok through empirical study on what the users think and expect.

Design of Green Community Rediscovery Center with Community Gardens and Social Integration Functions (공동체정원과 사회통합기능이 있는 Green Community Rediscovery Center의 설계)

  • Lee, Eung-Jik;Lee, Hyung-Sook;Yoon, Eun-Ju;Ekpeghere, Kalu I.;Koh, Sung-Cheol
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.29-36
    • /
    • 2011
  • The aim of this study was to study the functions and roles of Green Community Rediscovery Center (GCRC) in terms of community integration, to design GCRC with various types of green roofs, and to investigate the possibility of applying a renewable energy system (e.g., PV) to the building greenery systems. The four major functional modules for GCRC were suggested: implementation of ecopark and community gardens with environmental education programs, implementation of green housing model with education programs, Discover Science Center, and implementation of green business model with education programs. Three major functions of the center are also presented in terms of design: 1) functions of community gardens; 2) establishment of a green business model, community composting system and an urban farming system; and 3) roles of community gardens in social interactions within GCRC. GCRC provides residents with the opportunities of community gardens, urban farming based on a successful recycling system, as well as a green business model and environmental education programs near their homes. The air temperature of the green roof (utilizing Sedum sarmentosum as a cover plant) was approximately $3^{\circ}C$ lower than that of the non-green roof, indicating a potential efficiency increase in PV systems for GCRC. It was concluded that the GCRC suggested would enhance the neighborhood satisfaction, improve the quality of life and contribute to social integration and community regeneration.

The Characteristics of the Repair Cost Distribution in Apartment Housing

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.19-26
    • /
    • 2015
  • Purpose: The repair would require to conserve and improve the building function and performance since built. Each household is responsible for maintaining the public facilities and paying the required cost. Therefore, it needs to get the tool or method to forecast the required cost in the future. Before the repair cost is provided, it needs to catch the repair cost distribution and provide the unit cost for the repair cycle. In this study, it aimed at providing the repair cost unit and analyzing the repair cost distribution in a roof proofing work, elevator work and building painting, which are divided into a fully work and partly change. Results of this study are shown that first, the average repair cost for roof proofing work is provided with $166.59{\times}10^3won/household$ and $1.59{\times}10^3won/m^2$ of a full change, $33.22{\times}10^3won/household$ and $0.33{\times}10^3won/m^2$ for a partly work. In addition, elevator work is $557.45{\times}10^3won/household$ and $5.38{\times}10^3won/m^2$ for a full change, $32.92{\times}10^3won/household$ and $0.56{\times}10^3won/m^2$ for a partly repair. Painting has a $304.48{\times}10^3won/household$ and $2.94{\times}10^3won/m^2$. Second, the distribution pattern of repair unit cost has a weibull-typed distribution which has a long tail to the right.

Insulation Level Assessment on the Military Residential Facilities Considering the Investment Payback Period (투자회수기간을 고려한 군 주거시설의 단열수준 산정 연구)

  • Park, Young Jun;Meang, Joon Ho;Kim, Taehui;Kim, Sung Joong;Lee, Seung-Min;Son, Kiyoung
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • Purpose: This study, which is based on the investment payback periods, aims to suggest the proper insulation level which can be adapted to the Defense Military Facility Criteria regarding the military residential condominiums. For the energy performance simulation, it is required to collect the residential data regarding the military condominiums and climatic data concerning the regions they belongs to. The estimates through energy performance simulation are the regional heating loads and the heating transmission coefficients of building components. Method: With the heating loads, the annual heating cost saving per square meters is assessed. With the heating transmission coefficients of building components, the additional insulation installment cost per square meters is evaluated. With two outcomes, one as an annual value and the other as a present value, the investment payback period is calculated. Result: In result, it could be concluded that 55~70% insulation ratio can lead a superior residental environments as well as be contributed to the national policy associated with zero-energy buildings because the estimated investment payback period is shorter than the life span of the military residental condominiums. This upshot can be used as a foundation to enactment the Defense Military Facility Criteria associated with military residential condominiums.

Evaluation of Condensation Prevention for Centralized Hybrid Ventilation System Using TDR (TDR을 이용한 중앙집중형 하이브리드 환기시스템의 결로방지 성능 평가)

  • Kim, Yu-Min;Lee, Jong-Eun;Choi, Gyeong-Seok;Lee, Yong-Jun;Kang, Jae-Sik
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose: Condensation in the apartment housing is one of the most significant defects and complaints for condensation are rapidly increasing according to the growing interest in residential environment. Korea government established a regulation for reducing condensation in the apartment housing and TDR is adapted as a standard. However prevention of condensation depend on improving the performance of building envelop has limitation because of the increase of the cost. Centralized Hybrid ventilation system is suggested to prevent condensation. Method: Field measurement was conducted to verify the ventilation rate of the ventilation system. Based on the measurement, air network and CFD simulation was conducted to analyze ventilation rate for each room. Surface temperature was calculated by regulated TDR according to the regions and surfaces. The performance of condensation prevention was evaluated by the ventilation rate and surface temperature. Result: In the results, it was found that condensation was prevented in more than 90% of households by the centralized hybrid ventilation system which provided 0.19 ~ 0.81ACH for each room.

Policy Implications of Creative-Based Strategies and Culture-Art Creative Urban Policy in Japan: Focusing on Kanazawa and Yokohama (일본의 문화예술창조도시정책과 창조기반전략의 정책적 함의: 가나자와와 요코하마를 중심으로)

  • Na, Jumong
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.642-659
    • /
    • 2016
  • This study examines the characteristics of creative city policy for Japanese culture and arts creation cities and finds the implications of culture and arts city policy by reexamining the examples of Kanazawa and Yokohama from the viewpoint of creation-based strategy of the city. The policy implications of creative-based strategies are as follows. First, in terms of the governance of the creative-based strategy, Kanazawa conducted governance through a citizen-led cooperative network, while Yokohama promoted creative city policy through a local government-led cooperative network. Second, The mechanism of action of the endogenous resources of Kanazawa and Yokohama was different. Third, the territorial embeddedness in Kanazawa and Yokohama was easy for pedestrians to access to the customer center in the creation core area. Both cities have good access to domestic and international demand, and amenity is well established.

Development of modernizing Old Small-Hydropower system with custom-built at Overseas (해외 노후 수력발전시스템 수용가 맞춤형 현대화 기술개발 및 실증)

  • Kim, Woonhak;Kang, Seokwon;Shin, Giseok
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.174-181
    • /
    • 2018
  • Purpose: The purpose of this study is to develop and demonstrate the customized modernization technology of the old aged hydropower generation system in operation Method: The modernization design was carried out based on the daily, weekly, monthly, and yearly information of the power plant in operation at the site. Results: In this paper, a safety diagnosis of existing facilities located in the Philippiness was carried out in accordance with the Special Act on the Safety Management of Domestic Facilities, and a method for reinforcing the facilities was selected. Conclusion: The selection of wheel suitable for the local environment and the maintenance of the old facilities were designed by domestic repair/reinforcement technology.

Investigation of Coastal Erosion Status in Geojin Port Area (거진항 일대의 해안 침식 현황 조사 연구)

  • Kim, In-Ho;Song, Dong-Seob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Coastal erosion and its impact on human activities as well as the economic damage and environmental conservation of coastal area is one of major concern in the national policies. In this study, we conducted physical investigations to evaluate effects of erosion in the Geojin beach, which is located nearby the Geojin Port, for a detecting of shoreline change and beach cross-sectional area. The results showed that significant coastal erosion of the Geojin beach has occurred by the complex resources of natural factor, such as rising sea level, storm surges, high wave, and man-made construction. Especially, due to the sand supplement from Jasan river, the section which is nearby the estuary of Jasan river is maintained as a stable beach, whereas beach erosion of the other site in GW04 section has been increased indeed. Therefore, we suggest that it is need to continuous monitoring using DGPS and various surveying techniques to prevent beach erosion onto the GW04 section.

A Development of Cold-Mixed Reclaimed Asphalt Pavement Materials (도로포장용 상온 재생 아스팔트 혼합물 개발)

  • Lee, Jong-Man;Kim, Nak-Seok;Kim, Wan-Sang;Hong, Eun-Cheol
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.1-7
    • /
    • 2009
  • In order to use recycled aggregate as pavement base or subbase materials, the US and many other European countries have started research since the early 1980s. Korea also had a recycle idea as a plan for the vast amount of construction wastes due to the downtown renovation in the 1990s, but was not put into practical use. After the resources saving and recycle expedition law in 1994, wastes from construction sites that have more than a certain amount of construction budget were recycled as pavement base and subbase materials, but now, researches are being conducted to use them as paving materials. The use of construction wastes is meaningful in many ways. It helps the natural conservation and aggregate consumption, and also improves pavement performance. This research presents a development of cold-mixed reclaimed asphalt pavement materials using recycled aggregates.

An Analytical Study on the Shape Development of U-shaped Steel Damper for Seismic Isolation System (면진시스템용 U형 강재댐퍼의 형상 개발에 대한 해석적 연구)

  • Quan, Chun-Ri;Oh, Sang-Hoon;Lee, Sang-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.43-53
    • /
    • 2010
  • Seismic isolation is one of the most widely implemented and accepted seismic protection systems to limit or avoid damages from unforeseeable earthquakes. As an energy absorption device, however, the supplemental lead itself tends to pollute the environment. Consequently, it is predicted that the use of lead would be controlled. Considering the pollution caused by lead, several researchers are interested in the viability of using steel in place of lead. In this study, first, based on the results of a non-linear finite element analysis, the excellent deformation capacity of a very tough steel damper was demonstrated by comparing it with that of the SS400 damper and determining the effects of main parameters (the aspect ratio, thickness, and width) on the deformation capacity. Second, an optimum shape and design equation for a U-shaped damper with an opening based on stress distribution was suggested.