• Title/Summary/Keyword: 확산-열 영향

Search Result 231, Processing Time 0.029 seconds

Analysis of Flame Shape in Flare Stack (플레어스택의 화염 형상 분석)

  • Lee, Heon-Seok;Kim, Bum-Su;Jung, Sang-Yong;Yoo, Jin-Hwan;Park, Chul-Hwan;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.49-53
    • /
    • 2009
  • Relief systems can improve the process safety because it has the function for the prevention of overpressure. Flare stacks is necessary to avoid explosion, radiation, or toxicity by waste-gas emitted from relief system. Safe combustion is one of the important factors to improve safety and the quantity and velocity emitted is ruled in the API code 521. Due to the pressure of released gas and mass flow, a flame from flare stack is similar to jet fire. In this study, we have investigated the effect of flame form on complete combustion and heat emission. API code was similar to jet fire model in flame length, the flame had an effect on the ground.

  • PDF

Characterization of Selectively Absorbing Properties of Indium Tin Oxide Thin Films by UV-VIS-IR Spectroscopy (UV-VIS-IR 분광법에 의한 산화 인듐 주석 박막의 선택적 투과 흡수 특성 관찰)

  • Lee, Jeon-Kook;Lee, Dong-Heon;Cho, Nam-Hee
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.135-142
    • /
    • 1992
  • Indium tin oxide(ITO) films coated on the window glass selectively transmit the solar energy and infrared. We call this system passive solar collectors. Selectively absorbing properties of sol gel dip coated ITO films were characterized by UV-VIS-NIR spectroscopy. The effects of heat treating temperature, time, atmosphere, substrate and barrier layers are concerned. Indium tin oxide films heat-treated at $500^{\circ}C$ in a reducing atmosphere show intrinsic properties. Efficiency of solar energy transmittance was enhanced by coating of $SiO_2-ZrO_2$ as an alkali ion barrier layer. Energy was saved by the double layers of $SiO_2-ZrO_2$ and ITO since solar energy is transmitted and heat generated inside(${\lambda}$ > 2700nm) is reflected.

  • PDF

Thermal Cycle Reliabilties and Cracking Characteristics of Electroplated Cr/Ni-P Coatings (전해 Cr/Ni-P 도금막의 열 사이클 신뢰성 및 균열거동 분석)

  • Lee, Jina;Son, Kirak;Lee, Kyu Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.133-140
    • /
    • 2019
  • The effects of thermal cycle conditions on the bonding strength and crack propagation behaviors in electroplated Cr/electroplated Ni-P coatings were systematically evaluated. 1st heat treatment was performed at 500℃ for 3 hours after electroplating Ni-P, and then, 2nd heat treatment was performed at 750℃ for 6 hours after electroplating Cr. The measured bonding strength by ASTM C633 were around 25.6 MPa before thermal cycling, while it increased to 47.6 MPa, after 1,000 cycles. Increasing thermal cycles led to dominant fail mode with cohesive failure inside adhesive, which seemed to be closely related to the increasing bonding strength possibly not only due to higher Cr surface roughness, but also to penetrated channeling crack density. Also, increasing density of penetrated channeling cracks in electroplating Cr layer led to slightly stronger bonding strength due to mechanical interlocking effects of adhesive inside channeling cracks.

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

An Experimental Study for Characteristics Evaluation of Cement Mortar Using Infrared Thermography Technique (적외선 화상기법을 이용한 시멘트 모르타르 특성의 실험적 평가)

  • Kwon, Seung-Jun;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.53-59
    • /
    • 2010
  • Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

On the Annual Variations of Water Temperature and Salinity in Kwang Yang Bay (광양만의 수온과 염분의 연변화에 관하여)

  • 한영호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1975
  • The physical oceanographic investigations in Kwang Yang Bay, were carried out for seven times from May 1974 to May 1975. The results of this survey show that the salinity of the bay water is generally lower than that of the adjacent sea water, and mean surface salt ni ty in March and July were 20.8-25.2\ulcorner and 31. 8-32. 5\ulcorner. The month with the minimum surface water temperature was January with $2.5~5.2^{\circ}C:$ the maximum monthly value was $ 23.8-24.2 ^{\circ} C$ in September. The surface water temperature were related to the heat budget at the sea surface in the bay water, the degree of relationship was good. The mean vertical stability in the bay water(0-10m)were 297XI0^{-6} in July and -IXto^{-6} in January. The computed vertical stability indicate that the vertical mixing could move down to the depths of 15m during late autumn and winter, but the rest of season hardly take place to the depths of tom.

  • PDF

도시화가 진행된 경기도 지역의 수문시계열 자료분석

  • Yang, Jeong-Seok;Kang, Dae-Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1225-1229
    • /
    • 2009
  • 최근 수자원의 공급중심에서 효율적 이용으로의 정책변화에 따라 도시화에 따른 지하수위 및 하천수위에 대한 연구는 더욱 중요시되고 있다. 현재 도시화로 인한 땅속으로 침투되지 못하고 유출되는 강우는 도시화 이전인 1962년의 5배가 넘는 수준이다. 1962년 당시엔 40%에 이르던 빗물 침투율도 23%로 떨어져 물 부족 가능국가이면서도 강우 침투율은 저조하다. 이것은 도시화의 심화로 인한 시가지의 확대, 토지이용 고밀도화로 인한 불투수층 증가에서 비롯된 것으로서 지하수가 메마르고 토양이 건조해져 매년 평균 지하수위는 하강하고 있고 이것은 하천수위의 하강과 밀접한 관계가 있다. 본 연구에서는 경기도지역을 대상으로 도시화가 진행된 지역의 수문시계열 자료들을 수집하고 분석하였다. 수문시계열자료로서는 지하수위, 하천수위자료를 수집하였고, 토지피복도를 참고하여 시가지 증가율을 확인하였다. 도시화가 진행된 도심지역 내 지하수위 관측소를 중심으로 하천수위 중 자료에 문제가 없는 곳을 선정하였다. 선정된 지역 중 5개 지역에서 지하수위의 하강 및 하천수위의 하강이 관측되었다. 각 지역마다 연평균 하천수위 연평균 지하수위, 토지피복도를 도시하고, 토지피복도의 변화에 따른 불투수층확산지역의 지하수위와 하천수위의 변화를 분석하였다. 대부분의 지역에서 시가지 증가율에 따른 불투수층이 증가함에 따라 지하수위와 하천수위는 하강하고 있었다. 그러므로 도시화가 진행되면서 지하수위와 하천수위에 수문학적으로 부정적인 영향을 준다고 설명할 수 있고 여기에 최근 한국의 기후변화가 수자원에 미치는 영향도 고려한다면 수위하강은 더욱 가속화 될 것이다.

  • PDF

Formation of Al diffused back surface field on rear passivation layer (소성 온도 변화 따른 후면 전계 형성이 결정질 실리콘 태양전지 특성에 미치는 영향)

  • Song, Joo-Yong;Park, Sung-Eun;Kang, Min-Gu;Park, Hyo-Min;Tark, Sung-Ju;Kwon, Soon-Woo;Yoon, Se-Wang;Kim, Dong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.91-91
    • /
    • 2009
  • 태양전지의 전극소성 시 알루미늄 후면 전극이 실리콘으로 확산되어 후면전계(Back Surface Field)를 형성한다. 후면 패시베이션층은 후면반사율을 높여 내부광흡수경로를 늘리고 후면재결합속도를 감소시킨다. 본 논문은 후면 패시베이션층이 알루미늄 후면전계 형성에 미치는 영향 및 온도에 따른 변화를 관찰하였다. 절삭손상(Saw damage)이 제거된 실리콘 기판의 후면에 패시베이션층이 없는 것과 후면 패시베이션층으로 사용되는 실리콘 산화막을 형성시킨 시편을 제작하였다. 알루미늄 후면전극을 스크린 인쇄 후 소성온도를 달리하여 실리콘과 알루미늄과의 반응을 비교하였다. 주사전자현미경(SEM)을 사용하여 시편의 단면사진으로부터 소성온도에 따른 실리콘과 알루미늄간의 반응 여부를 관찰하였고, 열분석을 통해 반응 온도를 조사하였다. 패시베이션층이 없는 경우에는 약 $600^{\circ}C$부터 실리콘과 알루미늄간의 반응이 시작되었고, 패시베이션층이 있는 경우에는 약 $700^{\circ}C$부터 반응이 시작되는 결과를 얻었다.

  • PDF

Computational Study of Intermetallic Reaction Propagation in Nanoscale Boron/Titanium Metallic Multilayers (보론/티타늄 나노박막다층 내 이종금속간 화학반응 전파특성 해석연구)

  • Kim, Kyoungjin;Park, Joong-Youn
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.10-17
    • /
    • 2017
  • The analytical modeling has been established on the self-propagation of intermetallic reaction in the spanwise direction of highly reactive boron and titanium nanoscale multilayers. Assuming that the reaction obeys Arrhenius kinetics, two-dimensional computations are carried out for heat and atomic species diffusion with exothermic reaction model in order to simulate the self-propagation of intermetallic reaction. The effects of bimetallic layer thickness and thickness ratio on the reaction propagation speed are tested and discussed in addition to the assessment of pre-mixing zone effects.

램제트 엔진에서의 화염 전파와 비정상 연소 현상에 관한 수치해석

  • ;Vigor Yang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.10-10
    • /
    • 2000
  • 램제트 엔진은 비추력이 높고 추력 레벨은 낮으므로, 2단 추진기관에 적합한 추진 시스템이다. 1단-추진기관의 작동이 끝나고, 2단 램제트 엔진이 점화 후 안정된 연소에 도달되기까지 비행체의 속도는 항력에 의하여, 초당 약 마하수 0.1 정도씩 감소된다. 1단 연소 후 2단 램제트로 전환되는 지연시간이 길수록 1단에서 요구되는 종말 가속도는 증가되므로, 1단이 차지하게되는 부피는 증가되고 비행체의 크기 또한 늘어나게 된다. 따라서 1단에서 2단 램제트로 천이되는데 소요되는 시간을 가능한 짧게 하는 것이 효과적이다. 그러나 램제트 엔진의 특성상 선결되어야할 다음과 같은 여러 문제들이 있다. 첫째, 1단 작동 시 공기 흡입구와 연소실은 차단벽으로 분리되어 있다가, 1단 연소후 차단막이 제거되어 외부공기가 램제트 연소실로 흡입된다. 흡입되는 공기는 흡입구의 형상에 의하여 램 압축되지만 초음속으로 연소실을 통과하게된다. 연료 주입 구에서 공급되는 연료는 연소실에서 유동의 흐름방향(streamline)에 따라서 연소실로 확산되는데, 연소되기 전에는 유속이 빠르게 노즐로 빠져 나가므로 램제트 연료가 재순환 구역(recirculation zone)으로 침투하는데 쉽지가 않다. 둘째, 연소실 입구에서 발생되는 와류 (ring vortex)는 1단 연료의 고온 연소 가스를 연소실로 확산시키는데, 비 균일한 온도 분포를 유발하여 램제트 연료의 점화에너지가 공급되는 시간이 적당하지 않을 경우 균일한 화염 전파에 악영향을 준다. 셋째, 연소실에서의 빠른 유동 조건은 연료가 연소실에 머무를 수 있는 시간을 감소시키며, 연소실 입구에서 강한 전단 응력이 발생되어 화염이 안정화되는데 악 영향을 미치게된다. 본 논문은 공기 흡입구, 연소실 및 노즐을 통합하여 수치해석을 하였으며 열유동/점화/연소등의 미케니즘을 이해하고, 주요 인자들 중 와류의 영향에 초점을 맞추었다.다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14) 식도경 시행회수는 1회가 17례(54.8%), 2회가 9례(29.0%), 3회 이상이 5례(16.1%)였다.EX>$IC_{50}$/ 값이 210 $\mu\textrm{g}$/$m\ell$로서 효과적

  • PDF