• Title/Summary/Keyword: 확산 제어

Search Result 589, Processing Time 0.024 seconds

Study on Enhancing National Defense Security based on RFID and Internet of Things Technology (RFID와 사물인터넷을 활용한 국방 보안 강화에 대한 연구)

  • Oh, Se-Ra;Kim, Young-Gab
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.2
    • /
    • pp.175-188
    • /
    • 2017
  • Radio-frequency identification (RFID) is being used in various fields as a technology for identifying objects (people, things etc.) using radio frequencies. In the past, there was an attempt to apply RFID into national defense, but failed to spread RFID in the defense field because of some limitations of RFID in a specific situation (e.g., low recognition rate). Therefore, in this paper, we propose how to overcome the limitation of RFID by adopting the Internet of Things (IoT) technology which is considered as an important technology of the future. Furthermore, we propose four scenarios (i.e., healcare band and RFID, identification and anormal state detection, access control, and confidential document management) that can be used for enhancing national defense security. In addition, we analyze the basic characteristics and security requirements of RFID and IoT in order to effectively apply each technology and improve security level.

Smart Centralized Remote Security Service Provisioning Framework for Open ICT Environment (개방형 ICT 환경을 위한 집중식 원격 보안 서비스 프로비저닝 프레임워크 구성 방안)

  • Park, Namje
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.2
    • /
    • pp.81-88
    • /
    • 2016
  • Machine-to-Machine (M2M) communication provides each component (machine) with access to Internet, evolving into the IoT technology. IoT is a trend where numbers of devices provide the communication service, using the Internet protocol. As spreading the concept of IoT(Internet of Things), various objects become home information sources. According to the wide spread of various devices, it is difficult to access data on the devices with unified manners. Under this environment, security is a critical element to create various types of application and service. In this paper propose the inter-device authentication and Centralized Remote Security Provisioning framework in Open M2M environment. The results of previous studies in this task is carried out by protecting it with the latest information on M2M / IoT and designed to provide the ultimate goal of future M2M / IoT optimized platform that can be integrated M2M / IoT service security and security model presents the information.

Development of Program for Ignition Temperature and Its Applications (발화온도 산출 프로그램 개발 및 적용)

  • Park, Won-Hee;Cho, Youngmim;Kwon, Tae-Soom
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.4
    • /
    • pp.243-250
    • /
    • 2017
  • A fire phenomenon of a solid such as wood involves a phenomenon in which solid is heated from the outside and the gas generated through the thermal pyrolysis process of the material is burnt. The thermal pyrolysis phenomenon of the solid is a phenomenon in which the amount of energy incident from the outside, the amount of heat dissipation of the solid material, the heat transfer between the solid material and the surroundings including the amount of heat transfer to the air adjacent to the solid surface, and the fraction of oxygen in the air. In this paper, we calculate the required ignition temperature to simulate the fire phenomenon as simple as possible. By using cone calorimeter, the ignition time was measured by variously controlling the heat flux flowing into the wood specimen by using various wood specimens. The user friendly program is developed for calculation of the ignition temperature. Five different woods such as low density MDF, high density MDF, plywood, douglas fir and PB with various thickness are considered. The ignition temperatures suggested in this paper can be used for fire propagation analysis for woods.

Hospital Room Environment Monitoring System based on Wireless Communication (무선통신에 기반한 병실 환경 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.28-30
    • /
    • 2022
  • Recently, the number of confirmed cases has increased again with the new variant of COVID-19. Quarantine is recommended, especially to prevent the rapidly increasing spread, as environmental controls, such as minimizing contact with others, can increase safety. In addition, there are often cases in which the patient's condition cannot be confirmed from the standpoint of a guardian, such as visitation being prohibited under certain conditions. At this time, the sensor data values of oxygen, carbon dioxide concentrations, temperature and humidity, and alcohol, which are medical gases used in hospitals, are collected remotely using ZigBee wireless communication technology. Design a system that can be stored and monitored in a database. We propose an environmental monitoring system, which is a visualization system designed to allow hospitals to check and feedback data on the managed environment, and to give reliability to parents.

  • PDF

A Study on the Efficient Load Balancing Method Considering Real-time Data Entry form in SDN Environment (SDN 환경에서 실시간 데이터 유입형태를 고려한 효율적인 부하분산 기법 연구)

  • Ju-Seong Kim;Tae-Wook Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1081-1086
    • /
    • 2023
  • The rapid growth and increasing complexity of modern networks have highlighted the limitations of traditional network architectures. The emergence of SDN (Software-Defined Network) in response to these challenges has changed the existing network environment. The SDN separates the control unit and the data unit, and adjusts the network operation using a centralized controller. However, this structure has also recently caused a huge amount of traffic due to the rapid spread of numerous Internet of Things (IoT) devices, which has not only slowed the transmission speed of the network but also made it difficult to ensure quality of service (QoS). Therefore, this paper proposes a method of load distribution by switching the IP and any server (processor) from the existing data processing scheduling technique, RR (Round-Robin), to mapping when a large amount of data flows in from a specific IP, that is, server overload and data loss.

Ventilation Performance Study on Hydrogen Leakage Characteristics of Container Packaged Water Electrolysis Production System (컨테이너 패키지형 그린수소 수전해 생산 시스템의 수소 누출 특성에 관한 환기 성능 연구)

  • SOOIN KWON;BYUNGSEOK JIN;CHEEWOO LEE;SEONGYONG EOM;GYUNGMIN CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.3
    • /
    • pp.324-335
    • /
    • 2024
  • The container package type sealed water electrolysis production system installs mechanical balance of plant and electrical balance of plant as an integrated unit to enable independent operation within the package module. The auxiliary equipment required to operate the water electrolysis system must be integrated to reduce the installation area and shorten the installation time. At this time, as leak risk factors are placed in a dense space, when a hydrogen gas leak accident occurs, it can have a mutual influence on other adjacent facilities, so it contains various risk factors. In this study, when a gas leak occurs in a container packaged water electrolysis system, possible sources of leakage in the system according to the KS C IEC 60079-10-1:2015 and KGS GC101 standards were identified, and the leak rate and leak characteristics were calculated. did. The hazardous area and its range were calculated according to ventilation and dilution characteristics. In order to optimize ventilation characteristics, design of experiment was used to analyze the influence to evaluate the adequacy of ventilation, and overseas ventilation standards were analyzed and compared. In addition, the optimal ventilation structure and characteristics of the container packaged water electrolysis system were presented according to the results of the experimental design method.

Prostate Imaging Reporting and Data System (PI-RADS) v 2.1: Overview and Critical Points (전립선영상 판독과 자료체계 2.1 버전: 개요와 비판적인 의견)

  • Chan Kyo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.75-91
    • /
    • 2023
  • The technical parameters and imaging interpretation criteria of the Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) using multiparametric MRI (mpMRI) are updated in PI-RADS v2.1. These changes have been an expected improvement for prostate cancer evaluation, although some issues remain unsolved, and new issues have been raised. In this review, a brief overview of PI-RADS v2.1 is and several critical points are discussed as follows: the need for more detailed protocols of mpMRI, lack of validation of the revised transition zone interpretation criteria, the need for clarification for the revised diffusion-weighted imaging and dynamic contrast-enhanced imaging criteria, anterior fibromuscular stroma and central zone assessment, assessment of background signal and tumor aggressiveness, changes in the structured report, the need for the parameters for imaging quality and performance control, and indications for expansion of the system to include other indications.

A Study on the Hood Performance Improvement of Pickling Tank using CFD (전산유체역학을 이용한 산세조 후드 성능 개선에 관한 연구)

  • Jung, Yu-Jin;Park, Ki-Woo;Shon, Byung-Hyun;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.593-601
    • /
    • 2014
  • In this study, we investigated the methods of improving the capturing ability of acid fume by assessing the performance of slot-type external hood installed on both sides of an open surface tank for acid washing process. A field survey and the results of computational fluid dynamics revealed that capturing performance of existing hoods is very poor. To solve such problem, 'push-pull hood' that pushes from one side of an open surface tank and pulls on the other side was suggested. The initial prediction was that if a push-pull hood is used, the acid fume of an acid-washing tank surface could be moved towards the hood through the push flow. However, this study has confirmed that if the push flow velocity becomes too high, it could spread to other areas due to flooding from the hood. Therefore, if the push air supply is maintained at around 25 $m^3/min$(push 10 m/s), proper control flow is formed on the surface of a tank and acid fume that stayed at the upper part of the tank is smoothly captured toward the hood, significantly enhancing the capturing performance.

Prediction of Leachate Migration from Waste Disposal Site to Underground LPG Storage Facility and Review of Contamination Control Method by Numerical Simulations (수치모의를 통한 지하 LPG 저장시설에 인접한 폐기물매립지에서의 침출수이동 예측 및 제어공법 검토)

  • 한일영;서일원;오경택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.2
    • /
    • pp.51-59
    • /
    • 1996
  • In case waste disposal site is to be constructed close to the underground facilities such as LPG storage cavern which is completely maintained by groundwater pressure, it is generally requested that the possibility on leachate contamination of cavern area be reviewed and the countermeasure, if it is estimated cavern area is severely affected by leachate, be taken into consideration. Prediction was performed and leachate control plan was made using by analytical and the numerical analysis on the leachate migration which is likely to happen at the area between the proposed waste disposal site and the underground LPG storage cavern located at the U petrochemical complex. Analytical solutions were obtained by the conservative mass advection-diffusion equation and the effect of advection and dispersion factor on the leachate migration was reviewed through peclet number calculation and the functional relationship between the factors and leachate transport velocity was established, which leads to enable us to predict the leachate transport velocity without difficulties when different parameters (factors) are used for analytical solution. Numerical solutions were obtained by FEM using AQUA2D which is for the simulation of groundwater flow and contaminant transport. 3-D discrete fracture models were simulated and fracture flow analysis was performed and feasibility study on the water-curtain system was conducted through the fracture connectivity analysis in rock mass. As results of those analyses, it was interpreted that the leachate would trespass on the LPG storage cavern area in 30 years from the proposed wate disposal site and the vertical water-curtain system was effective mathod for the prevention of leachate's migration further into the cavern area.

  • PDF

An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system (종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구)

  • Ki, Young-Min;Yoon, Sung-Wook;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.526-535
    • /
    • 2006
  • An experimental study was carried out on a reduced scale tunnel model to grasp the behavioral feature of fire-induced smoke in the long tunnels. Based on Froude modeling, the 1/50 scaled tunnel model (20 m long) was constructed by acrylic tubes and paraffin gas was released inside the tunnel to simulate the 20 MW fire-induced smoke. me test results show, that after approximately 2 minutes of fire generation, was descended from the tunnel ceiling through the decrease of buoyancy, then it was symmetrically propagated about 90 meters for 4 minutes before jet fans were operated. The smoke was effectively controlled when the jet fans were operated and an air stream velocity was getting closed to reach a critical velocity (the minimum air velocity that requires to suppress the smoke spreading against the longitudinal ventilation flow during the tunnel fire situations). It was also found out that a range of smoke was spreaded about 3 meters from the origin of fire but the range was not propagated to the escape direction anymore. The early stage of the In operation, however, showed that the smoke was hardly controlled. It means that the operation of emergency ventilation system has many dangerous factors such as an intercepting breathing zone.