• Title/Summary/Keyword: 확산오염

Search Result 794, Processing Time 0.024 seconds

Supergene Alteration of High-Ca Limestone from the Pungchon Formation (풍촌층 고품위 석회석의 표성변질)

  • Oh Sung Jin;Kim Kyong Jin;Noh Jin Hwan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.135-144
    • /
    • 2005
  • In the high-Ca limestone zone of the Pungchon Formation of the Lower Chosun Supergroup, cryptocrystalline alterations with reddish brown color occur as fissure-fillings or coatings, which was originated from the upper formation, i. e., the Hwajeol Formation. The precipitates result in degradation and contamination of the high-Ca limestone ore in grade and quality, showing characteristic occurrence and mineral composition typical of suggesting a supergene origin. Chalcedonic quartz, kaolinite, illite, goethite and hematite are constituting a characteristic authigenic mineral assemblage and, in places, smectite is less commonly included in the weathering product. In addition to these authigenic phases, some detrital minerals such as mica and orthoclase constituting relatively coarser grains are also rarely present in the supergene alterations. A rather complex clay facies consisting of kaolinite, illite and smectite in the alterations seems to correspond to the typical clay composition of the reported residual pedogenic soils by limestone weathering. The cryptocrystalline weathering product is partly altered to stilbite, a characteristic hydrothermal zeolite, in places, by the hydrothermal contact of late stage. The time of formation and infiltration of the supergene alterations seems to correspond to the stage just after the epithermal alteration of the Pungchon Limestone, i. e., an early Jurassic age. The supergene alteration, which may imply the stage of uplifting, weathering and erosion of the Chosun Supergroup, appears to have undergone at an oxygen-rich environment in descending water of meteoric origin by means of a chemical leaching and diffusion.

Effects of Weathering Processes on Radioactive Cesium Sorption with Mineral Characterization in Korean Nuclear Facility Site (국내 원전 부지 내 암석의 광물학적 특성 규명 및 풍화에 따른 방사성 세슘(137Cs)의 흡착 평가)

  • Chang, Seeun;Choung, Sungwook;Um, Wooyong;Chon, Chul-Min
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.209-218
    • /
    • 2013
  • This study was to characterize the minerals in fractured and bedrock zone, and determine quantitatively sorption for radioactive cesium ($^{137}Cs$) at the Korean nuclear facility site. The rock samples were granite group that mainly consists of quartz and feldspar with 10~20% mica minerals. Chlorite was observed as secondary mineral for the rock samples collected from fractured zone, but not for bedrock samples. The $^{137}Cs$ sorption distribution coefficients increased to $K_d$ = 880~960 mL/g in the fractured zone because of the presence of secondary minerals formed by weathering processes, compared to the bedrock zone ($K_d$ = 820~840 mL/g). These results suggest that the released $^{137}Cs$ to groundwater environment could be significantly retarded in the fractured zone in the case of severe nuclear accident at the study site.

n-type GaN 위에 형성된 Ti/Al/Mo/Au 및 Ti/Al/Ni/Au 오믹 접합의 isolation 누설전류 분석

  • Hwang, Dae;Ha, Min-U;No, Jeong-Hyeon;Choe, Hong-Gu;Song, Hong-Ju;Lee, Jun-Ho;Park, Jeong-Ho;Han, Cheol-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.266-267
    • /
    • 2011
  • 질화갈륨(GaN)은 높은 전자이동도 및 높은 항복전계를 가지며 낮은 온저항으로 인하여 에너지효율이 우수하기 때문에 고출력 전력소자 분야에서 많은 관심을 받고 있다. GaN을 이용한 고출력 전력소자의 경우 상용화 수준에 근접할 만한 기술적 진보가 있었으나, 페르미 레벨 고정(Fermi-level pinning) 현상, 소자의 누설전류 등 아직 해결되어야 할 문제를 갖고 있다. 본 연구에서는 실리콘 기판 위에 성장된 GaN 에피탁시를 활용한 고출력 전력소자의 누설전류를 억제시키기 위해 오믹 접합 중 Au의 상호확산을 억제하는 중간층 금속(Mo or Ni)을 변화시켰으며 오믹 열처리 온도에 따른 특성을 비교 연구하였다. $Cl_2$$BCl_3$를 이용하여 0.6 ${\mu}m$ 깊이의 메사 구조가 활성영역을 형성하였고, Si 도핑된 n-GaN 위에 Ti/Al/Mo/Au (20/100/25/200 nm) 와 Ti/Al/Ni/Au (20/100/25/200 nm) 오믹 접합을 각각 설계, 제작하였다. 오믹 열처리시의 GaN 표면오염을 방지하기 위해 $SiO_2$ 희생층을 증착하였다. 오믹 접합 형성을 위해 각 750$^{\circ}C$, 800$^{\circ}C$, 850$^{\circ}C$에서 30초간 열처리를 진행 하였으며, 이후 6 : 1 BOE 용액으로 $SiO_2$ 희생층을 제거하였다. 750, 800, 850$^{\circ}C$에서 Ti/Al/Mo/Au 구조의 오믹 접합 저항은 각 2.56, 2.34, 2.22 ${\Omega}$-mm 이었으며, Ti/Al/Ni/Au 구조의 오믹 접합 저항은 각 43.72, 2.64, 1.86 ${\Omega}$-mm이었다. Isolation 누설전류를 측정하기 위해서 두 개의 오믹 접합 사이에 메사 구조가 있는 테스트 구조를 제안하였다. Isolation 누설전류는 Ti/Al/Mo/Au 구조에서 두 오믹 접합 사이의 거리가 25 ${\mu}m$이고 100 V일 때 750, 800, 850 $^{\circ}C$의 열처리 온도에서 각 1.25 nA/${\mu}m$, 2.48 nA/${\mu}m$, 8.76 nA/${\mu}m$이었으며, Ti/Al/Ni/Au 구조에서는 각 1.58 nA/${\mu}m$, 2.13 nA/${\mu}m$, 96.36 nA/${\mu}m$이었다. 열처리 온도가 증가하며 오믹 접합 저항은 감소하였으나 isolation 누설전류는 증가하였다. 750$^{\circ}C$ 열처리에서 오믹 접합 저항은Ti/Al/Mo/Au 구조가 Ti/Al/Ni/Au 구조보다 약 17배 우수하였고, 850$^{\circ}C$ 고온의 열처리 경우 Ti/Al/Mo/Au 구조의 isolation 누설전류는 8.76 nA/${\mu}m$로 Ti/Al/Ni/Au의 누설전류 96.36 nA/${\mu}m$보다 약 11배 우수하였다. Ti/Al/Mo/Au가 Ti/Al/Ni/Au 보다 오믹 접합 저항과 isolation 누설전류 측면에서 전력용 GaN 소자에 적합함을 확인하였다.

  • PDF

Analysis of Local Resident'S Perception on 'Rainwater for Drinking' Project in Developing Countries : Focusing on Vietnam Case Studies (개발도상국의 빗물식수화시설 사업에 대한 지역주민의 인식 분석 : 베트남 사례를 중심으로)

  • Lee, Minju;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drinking water deficiency is prevalent in developing countries due to contamination of surface and ground water, difficulties of water treatment, and lack of water infrastructures. 'Rainwater For Drinking (RFD)' projects are emerging as one of the effective solutions globally since RFD systems provide safe drinking water from rainwater. In RFD projects, perception of local residents toward RFD project is essential as local residents must manage their RFD systems on their own after the project finishes. This research performed survey and interview to 209 local residents, who use RFD systems, and analyzed their general perception, expected effects and feared factors toward RFD projects. Through the research, it was shown that the most of the local residents have positive perception towards RFD projects' effectiveness (41.9%) and are willing to participate (58.9%). The top three expected effect factors of the RFD projects were 'supply of safe water source', 'vitalization of local community', and 'expansion of RFD system'. The top three feared factors were 'quality of rainwater', 'technical factors of RFD system', and 'maintenance of RFD system'. The research findings indicate that development of simple water quality measuring device and education of the local residents about RFD system is necessary for better maintenance of the RFD system after the project finishes.

A Study on the ISO 14000' Trend and its Application Effect (ISO 14000의 동향과 효과에 관한 연구)

  • Myung, Chang-Sig
    • Korean Business Review
    • /
    • v.14
    • /
    • pp.77-93
    • /
    • 2001
  • The ISO issued the first standard for environmental management standard(EMS) in 1993. This standard provide for elements of an effective environmental management system and can also help companies ingrain effective environmental management practice into their overall business operations. ISO 14001 is predicted to become the leading voluntary environmental management system standard. Companies selling products and services internationally and domestically will also be affected by publication of this standard. Especially, this new environmental management standards are fast becoming a condition for doing global business because it can be acted with trade barriers. Actually, an automobile companies of America including Ford and GM require their subcontracting companies to gain the recognition of ISO 14001. The purpose of this paper is to investigate the ISO 14000 and its application of Korean firms focusing on environmental management system(EMS). This paper proceeds to present the effective alternatives through analysing the existing Korean firms which has established EMS. Korean firms should adopt EMS not for the enhancement of corporate image but for the purpose of strategic competitive advantage.

  • PDF

A Study on the Effect of Containment Filtered Venting System to Off-site under Severe Accident (중대사고시 격납건물여과배기계통(CFVS)적용으로 인한 사고영향과 결과 고찰)

  • Jeon, Ju Young;Kwon, Tae-Eun;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.244-251
    • /
    • 2015
  • The containment filtered venting system reduces the range of the contamination area around the nuclear power plant by strengthening the integrity of the containment building. In this study, the probabilistic assessment code MACCS2 was used to assess the effect of the CFVS to off-site. The accident source term was selected from a Probabilistic Safety Analysis report of SHINKORI 1&2 Nuclear Power Plant. The three source term categories from 19 STC were chosen to evaluate the effective dose and thyroid dose of residents around the power plant and the dose with CFVS and without CFVS were compared. The dose was calculated according to the distance from the nuclear power plant, so the damage scale based on the distance that exceeds the IAEA criteria for effective dose (100 mSv per 7 days) and thyroid dose (50 mSv per 7 days) were compared. The effective dose reduction rates of the STC-3, STC-4, STC-6 were about 95-99% in the whole range (0~35 km), 96-98% for the thyroid dose. There are similar results between effective dose and thyroid dose. After applying the CFVS, the damage scale that exceeds the effective dose criteria was about 1 km (mean). Especially, the STC-4 damage scale was decreased from 26 km (mean) to 1.2 km (mean) significantly. The damage scale that exceed the thyroid dose criteria was decreased to 2~3 km (mean). The STC-4 damage scale was also decreased significantly as compared to STC-3, STC-6 in terms of effective dose.

Characteristics of Enterotoxigenic genes and Antibiotic Susceptibility of Staphylococcus aureus Isolated from Tomato Farms in Western Gyeongnam (서부 경남지역 토마토 농장에서 분리된 Staphylococcus aureus의 내독소 유전자의 특성과 항생제 감수성)

  • Kim, Jin-Soo;Lee, Jin-Ha;Kim, Ji-Hun;Choi, Ju-Mi;Kim, Se-Ri;Ha, Sang-Do;Kim, Keun-Sung;Lee, Kyu-Ho;Kim, Min-Gon;Kim, Kwang-Yup;Kim, Cheol-Ho;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.295-303
    • /
    • 2006
  • To provide microbial information for the safety of agricultural production, the presence of enterotoxin genes and antibiotic susceptibility of 14 isolated Staphylococcus aureus (11.7%) strains were investigated using PCR-based methods and disk diffusion method, respectively. Among enterotoxin-encoding genes, sea was detected from two isolates (14.3%), sea and sed genes were co-detected from three isolates (21.4%), and sea, sed, and see genes in seven isolates (50.0%), whereas seb, sec, and tsst were not detected in any isolate. Nine (64.3%), eight (57.1%), six (42.9%), two (14.3%), and one (7.2%) isolates were resistant to penicillin, novobiocin, amphicillin, erythromycin and oxacillin, and doxycycline and kanamycin, respectively. Methicilline-resistant S. aureus was found in roller of B farm and in hydroponic solution of D farm.

Study on Consideration of Artificial Rain Technology in Aspect of National Security (국가안보측면으로서의 인공강우기술 고찰)

  • Choi, Kee-Nam;Lee, Sun-Je
    • Convergence Security Journal
    • /
    • v.12 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • March 11, 2010, in Japan located over East Sea of Korea, due to the strong earthquake tsunami, Fukushima Nuclear Power Plant was ceased and exploded resulting in leaking radioactive substances. Even though it was an accident happened in a nation, leaked radioactive substances were spread across the world moving along ocean currents and air current. Our nation also had terror and confusion about radioactive rain after the accident, and even though a year has been passed by after the accident, the problem on the radioactive contamination isn't solved. So to speak, nuclear accident of neighboring country is a threat to our nation but not only Japan but also Chinese ocean across the West Sea has nuclear power plants. Beside threat of nuclear accident of neighboring countries, North Korea in military confrontation is the world 3rd country holding chemical and biological weapons and can spray the biological weapons to South Korea at any time like Yeonpyeong-do bombard provocation in November, 2010. The study is the strategy confronting such threats and grafted artificial rain technology which is weather control technology. Since radioactive substances on radioactive accidents and North Korean biological weapons can differ in the density by the weather condition, only artificial rain technology can remove the threat perfectly but it is worth to try as the method to reduce damage and in the aspect of psychology. To use the artificial rain technology in the aspect of national security to acquire the public safety, research institutes such ADD should fulfill active and symbolic technology research development.

Planting Design Strategies and Green Space Planning to Mitigate Respirable Particulate Matters - Case Studies in Beijing, China - (미세먼지 저감을 위한 식재기법 및 도시 녹지계획 방향 - 중국 베이징시 사례를 중심으로 -)

  • Xu, Xi-ran;Kim, Jin-Oh
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.40-49
    • /
    • 2017
  • The purpose of the research is to analyze the recent cases of green space planning and planting design in Beijing, one of the cities having the worst particulate matters (PM) pollution. This study comprehensively reviewed Chinese academic literature addressing green space planning to reduce PM pollution. In addition, we conducted field observations and interviews with public officials from Beijing Municipal Bureau of Landscape Design in charge of planning and management of green spaces in Beijing. After the extensive review of literature we derived tree planting principles to mitigate the impact of PM from urban road system, residential area, and industrial district. Using the principles we evaluated the three recent cases of planting design to mitigate PM: Beijing Fuxing Road, Fu Run Residential Area and Beijing Beiqi Multipurpose Vehicle Factory. We conclude that green space planning and trees planting are not effective in mitigating negative impact of PM pollution because of inadequate selection of trees and inconsiderate planting composition. We proposed to replace the tree species with the ones capable of reducing the spread of PM, and reorganize planting compositions that consider the directions and characteristics of urban wind flow. This study suggests desirable types of tree species and planting compositions for road, residential and industrial districts, and we expect that it provides helpful guidelines for making planting design and species selection to mitigate the impact of PM in urban landscape.

Investigation of the Effect of Weirs Construction in the Han River on the Characteristics of Sediments (보 설치가 퇴적물 특성에 미치는 영향에 관한 연구)

  • Kang, Min Kyoung;Choi, In Young;Park, Ji Hyoung;Choi, Jung Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.597-603
    • /
    • 2012
  • To investigate the effects of weir construction on sediment characteristics of river bed, we conducted sediments sampling on the 9 locations near the weir, Kangchun, Yuju and Ipo in Namhan-River. Physical and chemical characteristics of sediments were analyzed by measuring particle size distribution, water content, Ignition loss, COD (Chemical Oxyzen Demand), TOC (Total Organic Carbon), TP (Total Phosphorus), SRP (Soluble Reactive Phosphorus) and TN (Total Nitrogen). Particle classification of all three weir sediments showed sandy loam that was caused by the river bed dredging. Due to the presence of weir, Ignition loss, COD, TOC, TP, SRP and TN showed similar trend such as the concentrations of upward weir had higher than those of downward weir. For the case of SRP concentration and C/N ratio, however, there is not much difference in the sediment characteristics compared to the those of sediments before weir construction. Therefore, It can be predicted that there are little effects of weir construction on sediment characteristics. However, weir construction could influence water quality of the river by controlling the transport and the accumulation of suspended materials from rainfall. Therefore, more intensive monitoring is required to examine the magnitude and patterns of sediment accumulation which could influence overlying water quality.