• 제목/요약/키워드: 화재온도

Search Result 1,074, Processing Time 0.026 seconds

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.

Prediction of sprinkler activation time in compartment fire (구획화재에서의 스프링클러 작동시간 예측 연구)

  • 김명배;한용식
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.13-18
    • /
    • 1996
  • A general description of sprinkler activation time in compartment-fire-generated smoke layers is made. For calculation of the time hot layer temperature is obtained from two-layer zonal model and time constant of sprinkler is measured. Upper-layer thickness at the instant of sprinkler activation is also presented with changes of opening area. The output of the present study provide inputs for the interaction modeling of sprinkler spray and compartment fire environment, which simulates fire suppression phenomena. Futhermore, experiments are performed in mock-up with gasoline pool fire in order to evaluate the reliability of the model.

  • PDF

An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab (터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구)

  • Woo Jin Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.262-269
    • /
    • 2023
  • Purpose: In this study,fire-resistance test were executed to evaluate the effectiveness of the fireproof panel attached to the PSC slab in tunnel. Method: For the fire resistance test, the RWS curve was applied and the furnace of the KICT was used. Result: As a result of the experiment, the maximum temperature measured on the concrete surface of the PSC slab with the fireproof panel was 321.8℃, which was lower than the damage limit temperature of 380℃ for concrete. Also, at the t=25mm, the maximum temperature was 35.2℃, which was lower than the damage temperature of steel, 250℃. The use of precast fire resistance panel(t=30mm) improves fire resistance of PSC structures. Conclusion: As a result of the test, a reinforcement method for attached a fireproof panel in case of fire in a tunnel or an underground roadway is provided to protect a structure from fire. In the future, it is necessary to perform the static performance test of the slab to which the fireproof panel is attached, and to confirm the adhesion performance of the fireproof panel by performing the pull-off test and the fatigue test.

Temperature and Flow Velocity Simulation for Fire in Synthetic Heat Transfer Fluid Boiler (열매유 보일러 내부 화재에 따른 온도 및 속도분포 시뮬레이션)

  • Kim, Yeob-Rae;Lee, Dong-Myung;Kim, Yun-Zeung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.472-475
    • /
    • 2012
  • MDF(Medium Density Fiberboard) 제조공정에 필요한 열매유(SHTF, Synthetic Heat Transfer Fluid)를 가열하는 보일러에서 화재가 발생하였다. 열매유 보일러는 1차 패스, 2차 패스, 3차 패스로 구성되어 있으며, 화재가 발생된 1차 패스 연소대 위쪽 14단 부근에서 열매유가 방출되었다. 화재확산으로 인한 조사내용 및 데이터를 토대로 화재 시뮬레이션용 전산유체역학인 ANSYS-CFX를 이용하여 재현하고 화재 모델링 해석 및 분석을 통해 화재 온도를 산정하고 피해의 범위를 규정하였다. 본 화재 사고로 설비의 운전 및 소재에 대한 피해를 규정하고, 이론에 의한 과학적인 정밀 조사를 실시하여 향후의 안전 운전을 위한 제안을 하고자 한다.

  • PDF

A Experimental Study on Window Glass Breakage in Compartment Fires (구획 화재시 창유리 파괴 현상에 관한 실험적 연구)

  • 이수경;김종훈;최종운;이정훈
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.21-30
    • /
    • 1998
  • This is a study on the relation of window glass breaking time, shape, and vent condition in a compartment fire through the experiment. We recognize the phenomenon that window glass breakage in a compartment fire be arose from the thermal stresses due to the temperature temperature difference was 233.4$^{\circ}C$ for test 1-3, 138$^{\circ}C$ for text 2-1, 83.6$^{\circ}C$ for test 2-2. The interior test 2-2, 400.9$^{\circ}C$ for test 2-3. so if the flame didn't reach at the surface of window glass, the breakage of glass occure at 40$0^{\circ}C$~50$0^{\circ}C$. when the fire size reached to 1541.14kW, the window might be broken by thermal stress. But window glass was not collapsed.

  • PDF

방재기술동향 - 화재조건 하에서 철근콘크리트 부재의 거동에 관하여

  • Jin, Yeong-Hwa
    • 방재와보험
    • /
    • s.98
    • /
    • pp.59-63
    • /
    • 2003
  • 이 연구보고서는 2003년 2월에 홍콩에서 열린 Fire Asia Intermational 2003 세미나 중의 일부로서 영국의 랭커셔대학의 플레튼교수가 발표한 것을 요약 소개하는 것으로, 가열조건하에 있는 콘크리트 구조부재 횡단면의 온도분포이력을 예측하기 위한 비선형유한요소모델(FEM)에 대한 것이다. 콘크리트에 있어서 온도 특성은 온도와 수분에 모두 민감한 것으로 가정하였으며 기존의 몇 가지 시험들이 개발된 모델과 비교되었다. 또한 실험값은 기존의 실험 결과와 비교 확인하였다. 이 연구보고서는 화재에 노출된 스틸보강이나 다른 강구조물 및 부재를 콘크리트가 보호한다는 점으 기본 가정으로 하고 있다.

  • PDF

An Analysis of the Smoke Control Characteristics of Water Curtain System for Underground Space (지하 공간의 워터커튼 시스템 화재제어 특성 분석)

  • You, Woo-Jun;Nam, Jun-Seok;Choi, Jin-Jong;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.298-301
    • /
    • 2011
  • 본 연구에서는 지하 방호공간에서 화재가 발생한 경우 워터커튼 시스템에 의한 연기의 차단효과와 화재제어 특성을 분석하였다. 이를 위해서 분사각도 $180^{\circ}$, 오리피스 직경 8.2 mm의 노즐과 지하방호 공간용 실화재 실험 장치를 제작하였으며, 화재강도 1.5 MW 기준 A급 1단위 화재 실험으로부터 온도분포와 가시도를 측정하여 연기의 차단효과를 확인하였다. 화재제어 특성을 분석하기 위해서 NIST(National Institute of Standards and Technology)의 해석프로그램인 FDS(Fire Dynamic Simulator)를 사용하여 동일한 실험조건에서 온도분포를 비교하였으며 노즐의 설치개수 변화에 대한 화재해석 및 실험결과로부터 워터커튼 시스템은 노즐의 설치위치와 개수, 화원으로부터의 거리, 제연 등의 설비 조건과 분사 노즐의 특성, 공급 유량 등이 중요한 상관관계를 갖고 있음을 확인하였다.

  • PDF

Estimation of Flame Temperature Ejected from the Opening for the Development of Urban Fires Simulation. (도시화재 시뮬레이션 구축을 위한 개구분출화재의 온도 예측)

  • Kim, Nam-Hyuk;Shin, Yi-Chul;Koo, In-Hyuk;Nam, Dong-Gun;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.346-350
    • /
    • 2010
  • 도시화재의 연소 확대성상을 모델화하기 위해 화재실의 개구를 통하여 분출하는 열기류의 온도 평가 실험을 실시하였다. 실험은 축소모형 형태로 개구 조건과 화원조건에 의해 진행이 되었다. 실험 결과 온도분포 Trajectory는 개구종횡비 n에 의해 횡정(橫井)의 연구결과와 비교하여 n=2일때를 제외하고는 다른 경향을 나타냈다. 동일 조건에서 분출화재보유열량 $Q_{ef}$은 개구 조건이 횡장창($B0.2m{\times}H0.1m$)이고, 단일개구일 때 가장 높은 값을 나타냈다. 또한, 분출화재의 발생 한계 발열속도 $Q_{verit}$에서도 굴웅아(堀雄児)의 연구와 유사한 결과를 보이며, 다른 개구조건보다 횡장창($B0.2m{\times}H0.1m$)일 때 높은 값을 나타냈다.

  • PDF

A Study on the Development of a Duct-dedicated Intelligent Fire Detection System (덕트전용 지능형 화재감지시스템 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Gun-Ho;Lee, Chun-Ha;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.39-48
    • /
    • 2015
  • This research was done to develop a duct-dedicated intelligent fire detection system to prevent fires and minimize fire damage of the industrial duct having a high fire risk. To understand the fire hazards of the ducts, the analysis was centered on the Daegu Textile Industrial Complex, where industrial ducts are used frequently. With this in the background, dedicated fire detectors and fire alarm control panel, which can prevent fires and to minimize fire damages to the ducts, were designed and produced, after which the performance was confirmed. As a result of performance experiments, it was shown that a duct-dedicated intelligent fire detection system had excellent adaptability and temperature accuracy. Through real-time temperature monitoring of the inside of the ducts, it was confirmed that duct fires could be efficiently extinguished by stepwise control of linkage facilities according to the setting temperature.

방화문 열전달에 의한 대피공간 내부의 온도영향성 연구

  • An, Chan-Sol;Yeo, In-Hwan;An, Jae-Hong;Jo, Gyeong-Suk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.172-173
    • /
    • 2013
  • 발코니 확장에 따른 아파트의 화재안전기준 강화를 목적으로 건축법 시행령 제 46조 제 4항의 규정에 따라 현재 건축되고 아파트에는 $2m^2$이상의 대피공간을 설치해야 한다. 그리고 대피공간은 채광방향과 관계없이 거실 각 부분에서 접근이 용이한 장소에 설치해야 하며, 출입구에 설치되는 갑종방화문은 거실쪽에서만 열 수 있는 구조로 해야한다. 하지만 현재 시공되고 있는 방화문은 비차열성 방화문으로써 거실공간에서 화재가 발생하였을 경우 방화문의 열전달 현상에 의해 대피공간 내부의 온도상승이 유발되지만 현재 방화문의 차열성능에 대한 규정이 부재하기 때문에 향후 인명피해가 우려되는 상황이다. 본 연구에서는 실제 방화문의 성능시험을 통해 대피공간과 접한 방화문 면의 온도변화를 측정하였으며, 이로 인한 대피공간 내부의 온도변화를 분석하기 위해 수치해석을 수행하였다.

  • PDF