• Title/Summary/Keyword: 혼입효과

Search Result 451, Processing Time 0.026 seconds

Commercial Application of Porcine MC1R Gene Polymorphisms to Korean Pork Industry (돼지 MC1R 유전자변이의 양돈산업 적용)

  • Ha, You-Kyoung;Choi, Jung-Suk;Kim, Sang-Wook;Choi, Yang-Il;Lee, Seug-Soo;Choi, Jae-Won;Jeon, Soon-Hong;Kim, Kwan-Suk
    • Journal of Animal Science and Technology
    • /
    • v.51 no.3
    • /
    • pp.193-200
    • /
    • 2009
  • The pork from black-coated pigs is famous among-consumers for better eating quality. The loci affecting black coat color was identified in pig chromosome 6 in which several genetic effects on pork quality have been reported. The melanocortin 1 receptor (MC1R) gene is a major gene which plays a key role in regulation of eumelanin (black/brown) and phaeomelanin (red/yellow). In this study, the MC1R gene polymorphism was analyzed for pig breed determination and genetic association with pork quality traits. MC1R Ala243Thr variation was analyzed to determine a specific genotype for four commercial pig breeds (Landrace, Yorkshire, Berkshire and, Duroc) and a Korean native pigs (KNP). Then we developed original KNP-specific DNA markers to determine the pork from black-coated pigs using MC1R DNA sequences. The total length of the MC1R coding sequence ranged 1451bp in KNP. KNP had the 0201 allele pertaining to $E^{D1}$ but some of the KNP had the $E^P$ allele, probably reflecting the geneticintrogression of $E^P$ allele into KNP. Furthermore, a relationship between Leu102Pro single nucleotide polymorphism (SNP) genotype and pork quality phenotype were analyzed in F2 reciprocal-crossbred population between KNP and Yorkshire. Association analysis indicated that the allele of the MC1R gene has no effect on pork quality. These results suggest that black coat-color is not directly associated with preferred pork quality, but the black-coat color pig breed may have other genetic components for superior pork quality.

Effect of Grinding Method and Grinding Rate on the Dry Beneficiation of Kaolin Mineral (분쇄방식 및 분쇄율이 고령토 광물의 건식 정제에 미치는 영향)

  • Kim, Sang-Bae;Choi, Young-Yoon;Cho, Sung-Baek;Kim, Wan-Tae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • The characteristics of beneficiating kaolin mineral by liberation (selective grinding) and air classification have been investigated, comparing the grinding rates of ball mill and impact mill. The ore was ground using a ball mill and a impact mill to evaluate the grindability of the two grinding methods based on the constant production amount of fine particles in size less than 325 mesh. Then, the fine product was further separated into two fractions using an air-classifier and each fraction was chemically analyzed to compare the beneficiation efficiency of the two grinding methods. The chemical grade of kaolin mineral decreased as increasing the grinding rate of both the mills. particularly in the case of ball mill because of overgrinding impurities such as quartz and feldspar. In the case of the ball milling, the fine fraction less than 325 mesh was air-classified at a cutting point of $43\;{\mu}m$. The production rate of the air-classified concentrate was found to be 66.2 wt%, removing 5.3% of $Fe_2O_3$ and 34.6% of CaO. Under the same conditions mentioned above with the impact mill, the production rate of the air-classified concentrate was 64.4 wt%, removing 34.2% of $Fe_2O_3$, 67.6% of CaO and 25.0% of $TiO_2$. Therefore, our results indicate that impact mill is superior to ball mill in terms of impurity removal.

A Study on the Properties of Recycled Concrete Using Recycled Fine Aggregates with different Removal formulas of Powder In Aggregate (미분 제거방식이 다른 2종의 재생 잔골재가 콘크리트외 특성에 미치는 영향)

  • Lee Mun-Hwan;Lee Sea-Hyun;Shim Jong-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.95-104
    • /
    • 2005
  • The research conducted to study the potential practicability of recycled aggregate concrete by analyzing the characteristics of concretes made of recycled quality aggregates produced by wet and dry process has found the following results. The air content of recycled aggregate concrete increased with increase of the substitut on rate due to mortar included while producing recycled aggregates. However, the concretes with aggregate produced by dry process had relatively low rate of increase in air content. The slump showed generally decreasing trend as the substitution rate of recycled aggregate increased regardless of the wet or dry process. It was assumed that the mortar particles remained in recycled aggregate absorbed the surplus hydration in concrete and decreased fluidity The compressive strength generally decreased as the substitution rate of recycled aggregate increased, however there was an increasing trend as well due to decreasing effect of water-cement ratio when the substitution rate of recycled aggregate reached 25, 50% after mix. This phenomena also appeared in early age, which meant that recycled aggregate concrete should not be retarded in setting when applied in the field. The tensile strength also reached the maximum when wet or dry recycled aggregate replaced with 25%. To conclude, recycled aggregates for concrete produced by wet or dry process are expected to demonstrate essential characteristics of concrete without significant decline in physical or dynamic quality when the substitution rate is below 25% although there are variations subject to water-cement ratio. However, slight differences are expected due to types of recycled aggregate and physical quality.

Experimental Study on Engineering Properties of Concrete Using Fluosilicates Based Composite (규불화염계 복합 조성물을 혼입한 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Yang Il-Seung;Yun Hyun-Do;Kim Do-Su;Khil Bae-Su;Han Seung-Gu
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.769-774
    • /
    • 2005
  • Fluosilicic acid(H2SiF6) is recovered as an aqueous solution which absorbs $SiF_4$ produced from the manufacturing of industrial-graded H3PO4 or HF. Generally, fluosilicates are the salts produced by the reaction of H2SiF6 and metal salts. Addition of fluosilicates to cement endows odd properties through unique chemical reaction with the fresh and hardened cement. This study was performed to know mechanical properties and watertightness using fluosilicates based composite made from fluosilicates and other compounds. Mix proportions for experiments were modulated at 0.45 of water to cement ratio and $0.0-2.0\%$ of adding ratio of fluosilicates based composite. Evaluation for mechanical properties of concrete was conducted to know fresh state of concrete, hardening state of concrete, and watertightness. Evaluation for watertightness of concrete was carried out permeability, absorption test and porosity analysis. In addition. Scanning Electron Microscopy(SEM) and Energy Dispersive X-Ray(EDX) used for investigating micro-structure and atomic component distributed in hardened concrete. It is ascertained that characteristics of mechanical properties and watertightness was more improved than non-added because of packing role of fluosilicates based composite and pozzolanic reaction of soluble $SiO_2$. Also, concrete added fluosilicates based composite had a tendency to delay setting time and only $0.5\%$ addition of fluosilicates based composite delayed 150 minutes compared with non-added.

Estimation of Air Void System and Permeability of Latex-Modified Concretes by Image Analysis Method (화상분석법을 이용한 라텍스개질 콘크리트의 공극 구조와 투수성의 상관성 분석)

  • Jeong Won-Kyong;Yun Kyong-Ku;Hong Seung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.695-702
    • /
    • 2005
  • It is known that latex-modified concretes were increased their durability and permeability by added latex. The purpose of this study was to analysis the air void systems in latex-modified concretes using a reasonable and objective image analysis method with main experimental variables such as water-cement ratios, latex contents(0%, 15%) and cement types(ordinary portland cement, high-early strength cement and very-early strength cement). The results are analyzed spacing factor, air volume after hardened, air distribution and structure. Also, air void systems and permeability of latex-modified concretes were compared with correlation. The results are as follows; The same w/c ratio LMC showed better air entraining effect than OPC with AE water reducer. The VES-LMC showed that the number of entrained air below $100{\mu}m$ increased more than four times. In the HES-LMC, micro entraining air having range from 50 to $500{\mu}m$ increased above 7 times without antifoamer. Though spacing factor was measured low, latex-modified concretes were showed that permeability was good. It is considered that air void system does not have an effect on the property of latex-modified concretes but latex film is more influenced in the their durability.

Corrosion-Inhibition and Durability of Polymer-Modified Mortars Using Bisphenol A and F Type Epoxy Resin with Calumite (비스페놀 A 및 F형 에폭시수지와 칼루마이트를 병용한 폴리머 시멘트 모르타르의 방청성 및 내구성)

  • Kim, Joo-Young;Kim, Wan-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.517-524
    • /
    • 2014
  • Nitrite-Type hydrocalumite (calumite) is a material that can adsorb chloride ions ($Cl^-$) that cause corrosion of reinforce bars and liberate the nitrite ions ($NO_2{^-}$) that inhibit corrosion in reinforced concrete. In this study, polymer-modified mortars using two types of epoxy resin with calumite are prepared with various polymer binder-ratios of 0, 5, 10, 15, 20% and calumite contents of 0, 5%. The specimens are tested for chloride ion penetration, carbonation, drying shrinkage and corrosion inhibition. As a result, the chloride ion penetration and carbonation depth of PMM using epoxy resin somewhat increases with increasing calumite contents, but those remarkably decreases depending on the polymer-binder ratios. The 28-d drying shrinkage shows a tendency to decrease with increasing polymer-binder ratio and calumite content. Unmodified mortars with calumite content of 5% did not satisfy quality requirement by KS. However, it was satisfied with KS requirement by the modification of epoxy resin in cement mortar. On the whole, the carbonation and chloride ion penetration depth of epoxy-modified mortars with calumite is considerably improved with an increase in the polymer-binder ratio regardless of the calumite content, and is remarkably improved over unmodified mortar. And, the replacement of the portland cement with the calumite has a marked effect in the corrosion-inhibiting property of the epoxy-modified mortars.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

A Study on the Properties of High-Fluidity Concrete with Low Binders Using Viscosity Agent (증점제를 사용한 저분체 고유동 콘크리트의 특성에 관한 연구)

  • Park, Gi-Joon;Park, Jung-Jun;Kim, Sung-Wook;Lee, Dong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.689-696
    • /
    • 2017
  • The practical applications of ordinary high-fluidity concrete have been limited due to several drawbacks, such as high hydration heat, high amount of shrinkage, and non-economic strength development. On the other hand, due to its advantages, such as improvement of construction quality, reduction of construction cost and period, the development of high-fluidity concrete is a pressing need. This study examined the properties of high-fluidity concrete, which can be manufactured on the low binders using a viscosity agent to prevent the segregation of materials. The optimal viscosity agent was selected by an evaluation of the mechanical properties of high-fluidity concrete among six viscosity agents. The acrylic type and urethane type viscosity agents showed the best performance within the range where no material separation occurred. The mechanical properties were evaluated to examine the optimal amount of AC and UT viscosity agent added by mixing two viscosity agents according to the adding ratio and blending them together with high performance water reducing agent. When the ratio of the AC : UT viscosity agents was 5:5, it was most suited for high-fluidity concrete with low binders by increasing the workability and effect of the reducing viscosity.

Different mechanism of visual attention in anxious and non-anxious population (부정자극 지각에 관련된 불안인과 정상인의 공간주의 비교연구)

  • Choi, Moon-Gee;Koo, Min-Mo;Park, Kun-Woo;Nam, Ki-Chun
    • Korean Journal of Cognitive Science
    • /
    • v.20 no.1
    • /
    • pp.51-77
    • /
    • 2009
  • Using a modified Posner's cue-target paradigm, we investigated whether negative cues attract more attention than neutral cues in anxious people. Previous studies used commonly an unbalanced proportion of valid and invalid trials(75% vs. 25% respectively). But in the present study, an equivalent proportion of valid and invalids trials was used for measuring detection speed of cues without participant's expectancy caused by the unbalanced proportion. Emotional words(Experiment 1) and facial expressions(Experiment 2) were used as cues for target locations. The result of Experiment 1 and 2 showed that threatening cues facilitated target detection in valid trials and interfered with it in invalid trials in anxious participants and a, reverse response patterns were found in non-anxious participants. This indicates that threatening cues attract more attention to the cued location in anxious people and in contrast, non-anxious people avoid threatening stimuli. In Experiment 3, we investigated the difference of validity effect across anxiety levels. The results showed that anxious participants gave less attention to cued location when the cues were non-informative whereas non-anxious participants gave more attention to cued locations in the same condition. We discussed two kinds of cognitive bias caused by anxiety levels: attentional bias and proportion related bias.

  • PDF

The Effect of Storage Container Types on Odor Emission and Quality of Piggery Liquid Slurry Fertilizer in the farms (농가의 돈분액비 저장형태가 악취발생과 액비품질에 미치는 영향)

  • Park, Moo-Eon;Kang, An-Seok;Kim, Si-Chang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.3
    • /
    • pp.136-143
    • /
    • 2006
  • The study was carried out to evaluate odor emission during storage time and quality of liquid slurry fertilizer along with three storage container types installed at farmer's fields in Cheorwon. Liquid slurry manure stored in the liquid-circulated or the air-injected tank was very homogeneous in concentration of nutritional elements because of well mixing operation, while nutritional concentration of the manure stored in the non-treated tank was significantly different from top to bottom in the tank, which may bring about partially irregular growth of plant after its application. The potential capacity of offensive odor emitted from liquid slurry manure stored in the liquid-circulated or the air-injected tank was much lower than that emitted from manure stored in the non-treated tank. Low potential capacity may less emit offensive odor after application of piggery liquid slurry on the field. The efficiency in oder to reduce odor emission from liquid manure was slightly higher in the liquid-circulated tank than the air-injected tank