• Title/Summary/Keyword: 현장 분석

Search Result 11,458, Processing Time 0.041 seconds

The Field Applicability of Road Pavement Layer with Grid Typed Reinforcement and Dispersive Fiber (그리드형 보강재와 분산성 섬유를 활용한 도로 포장층의 현장 적용 특성)

  • Park, Ju-Won;Kim, Hun-Kyum;Kim, Sung-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.53-59
    • /
    • 2018
  • This study analyzed the field applicability through the combination of environment-friendly grid-typed reinforcements and pre-mixed fiber with filler. The film of the grid-typed reinforcement is made by recycled PE resin. And, Ascon fiber is obtained the dispersion by pre-mixing of filler. To be able to recognize in advance the various circumstances that could arise in the construction of the road pavement layer, we conducted a basic field application test of the (Mock Up) pavement layer. As a result, it was found that the pavement with environment-friendly grid-typed reinforcement and dispersive fiber construction had improved strength, stress, and rutting resistance. It is consistent with the strength and stress results of the actual test of the mock up specimen. It is expected to perform an effective role in the safety as well as the use of environment-friendly fibers in actual construction.

A case Study on Collapse Causes and Restoration of Retaining Wall with Vegetated Concrete Block (식생블록 옹벽의 붕괴원인 및 복구방안에 관한 사례 연구)

  • Hong, Gigwon;You, Seung-Kyong;Yun, Jung-Mann;Park, Jong-Beom;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.105-115
    • /
    • 2016
  • This paper describes a restoration of retaining wall, which was collapsed by rainfall. The failure causes was analyzed by field case, and then the countermeasure was suggested. The failure causes confirmed that observance of design and construction criteria was insufficient. It also was the climate condition like a rainfall and inappropriate construction management. The stability analysis for retaining wall, soil improvement and reinforced earth wall was conducted to confirm validity of the countermeasure. The analysis results showed that the suggested construction method satisfied in required safety factors. Therefore, it should be secured the stability of the structure based on the application of appropriate design method and construction management, when structure was constructed.

A Study on the Safety Management Procedures during Theme Groups Experiential Learning Experiences (단체 테마 현장체험학습의 안전관리에 관한 연구)

  • Bang, Sungmin;Kim, Changho
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.63-72
    • /
    • 2015
  • This study aims to examine the state of accidents and related issues related to Theme Groups experiential learning experiences of students and suggest ways to improve security measures to prevent future incidents. Case studies of the sunken Sewol ferry and the collapse of the gymnasium at Mauna resort in Gyeongju are conducted by analyzing the existing literature and the data collected from the media sources and related agencies. With a basis on the findings of the analyses, it is suggested that legal foundation and disaster and risk management systems (systematic revision of the laws, raised safety awareness among citizens, production and education of security managers, formation of disaster management organizations, establishment of headquarters in case of emergency and installation of first aid facilities, improved national response system, enforcement of disaster drills, introduction of assessment system, etc.) must be established to contribute to creating a safer society.

Environmental Characteristics of Waste Tire for Use as Soil Reinforcement (지반보강재로서 폐타이어 사용에 따른 환경영향 분석)

  • Cho, Jinwoo;Lee, Yongsoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • This paper presents an experimental results on the environmental characteristics of waste tire. Experimental program includes a set of laboratory leaching tests and field pilot test for leachate analysis. Laboratory tests were conducted to illustrate how properties such as TOC, pH, turbidity and Zn change with tire sizes and drain conditions. In field pilot test, water samples were collected form a drainage system installed below the tire-reinforced retaining wall and analyzed for chemical quality. Laboratory leaching tests performed on various particle sizes of waste tire indicated that as tire size is increased, the concentration of leachate is decreased. In continuous flow column tests, the concentration of leachate decreased with the number of exposure periods or pore volumes flushed through the waste tire. However, during pause flow column tests, the concentration of leachates were increased with time. Field monitoring of effluent indicated that no significant adverse effects on ground water quality had occurred over a period of 12 months.

Analysis of Heavy Metal Contaminated Soils Remediation Using Reactive Drains (반응성 배수재를 이용한 중금속 오염토양의 정화효율 분석)

  • Park, Jeongjun;Choi, Changho;Shin, Eunchul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.1
    • /
    • pp.29-38
    • /
    • 2013
  • This paper presents the analysis condition of remediation technique of contaminated fine-grained soil and physical properties of bio-degradable drain for analysis site applicability using bio-degradable drain method. As the result, two kinds of developed degradable drains (cylindricality shaped and harmonica shaped) are satisfied the Korean Industrial Standard. And the cylindricality shaped drain has an excellent discharge capacity than that of another one. By the results of laboratory test, the citric acid is chosen as the washing agent because it has low toxicity, so it is able to minimize harmful influence to environment. Furthermore the subject contaminants were selected as Cd, Cu and Pb. Based on the field pilot test results, the most remedial efficiency is the use of reactive material applied in bio-degradable drain method with the process of injecting the washing agent and extraction of contaminated fluid.

A Study on the Factors Affecting the Responses after Volunteering Activities among Corporate Volunteers (기업자원봉사자의 자원봉사반응에 영향을 미치는 요인에 대한 연구)

  • Hwang, Chang Soon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.492-506
    • /
    • 2016
  • This study is aimed to investigate the factors predicting the responses after volunteering activities among corporate volunteers. While positive responses to volunteering are conceptualized as both the degree of satisfaction from volunteering and the perceived contribution of volunteering, negative responses are conceptualized as the degree of burnout. Family supports, the volunteering support system of corporation, various human relations in volunteering sites are selected and empirically tested as variables predicting the differential responses after volunteer activities. Questionnaire data were collected from 250 corporate volunteers and analyzed through hierarchical regression analysis. The results showed that while family supports have no significant effects on volunteering responses, corporate support system of volunteering have significant effects. Additionally, human relations with clients and volunteers managers have strong and positive significant effects on positive responses including the degree of satisfaction and the perceived contribution. However, no significant effect has been found on negative responses represented by burnout. Findings from this study emphasized the importance of human relations management in volunteering sites for corporate and nonprofit volunteer managers to increase the positive response from corporate volunteers.

A Survey of the Satisfaction Level of Construction Information System From Users' Viewpoints On Construction Site (현장 사용자 관점에서의 건설 정보시스템 만족도 분석)

  • Yoon, Jeong-Hwan;Yoon, Su-Won;Chin, Sang-Yoon;Kim, Yea-Sang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.4 s.32
    • /
    • pp.126-136
    • /
    • 2006
  • Most of large construction companies have developed construction information systems and their ultimate goals should be improvement of the management efficiency of the construction projects. In order to make them successful, the systems should be designed to meet system users' needs Therefore purpose of this study is to evaluate the current information management systems from the viewpoint of the system users, especially on-site engineers. Questionnaire surveys and interviews have been conducted for the highly ranked 10 construction companies on four major factors including the functions of the systems and satisfaction level of each function, recognition of the use effect, informatization support. From the surveys results, correlation between the functions of the systems and the others has been statistically analyzed.

A Pilot Test of Various Vertical Drains and its Initial Monitoring Results (다양한 연직배수재의 시험시공 및 초기현장 계측)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • Although the discharge capacity of the natural fiber drains are very low compared to that of plastic drain board (PDB), it is found that the conventional fiber drains and the new developed straw drain boards have great potential for use as a substitute for conventional plastic drain boards through several model tests. To verify their field application, a pilot test using environmentally friendly drains is also being carried out to prove their effective discharge capacity in the field. The pilot test site was divided into 5 different areas, with various combinations of vertical and horizontal drains installed for evaluation. Definite characteristics of various drains are still to be found due to the delay in construction of embankment. Consolidation behavior of three types of vertical drains and two types of horizontal drains will be analyzed after the completion of the embankment in the near future.

  • PDF

The Improvement of the Tidal Boundary Condition in the Han River Estuary for Hydraulic Analysis (한강하구지역의 수리학적 분석을 위한 하류경계 조건의 개선 방향)

  • Park, Hyo-Seon;Byeon, Seong-Joon;Choi, Gye-Woon;Lee, Yong-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.610-610
    • /
    • 2012
  • 한강하구는 국가하천인 한강, 한강의 1지류인 임진강과 북한 황해도의 예성강이 만나 한강하류 수역을 형성하여 서해 중부해역과 합류하여 매우 복잡한 수리학적 특성을 지닌다. 또한 한강하구의 경우 교량, 수중보 등의 하천 구조물이 설치되어 있다. 수리학은 크게 수위와 관계되는 현상, 하상변화와 관계되는 현상, 외부 환경과 관계되는 현상으로 살펴 볼 수 있다(최계운, 2005). 하천구조물이 설치됨에 따라 구조물 주변에서 국부적으로 수위가 상승되거나 유속이 변화, 세굴현상 등의 하상 변화, 구조물 설치에 따른 생태계의 단절 현상 등 수리학적 현상에 영향을 미치게 된다. 한강하구는 이러한 복잡한 흐름현상에 더해 군사적으로 민감한 지역의 특성으로 현장의 접근성에 한계가 있어 이 지역의 연구조사는 더욱 어렵다. 그간 한강하구의 흐름 현상을 규명하기 위한 연구 방법으로 수치모의를 통한 다양한 연구가 진행되어 왔다. 수리학적 흐름 현상을 계산하기 위한 필수 조건인 하류경계조건 설정에도 어려움이 수반된다. 이 때문에 한강의 수리학적 수치모의 실험에 관한 연구들은 한강하구의 얕은 수심과 해석의 공간적 범위를 소홀히 하고, 공릉천 합류부를 기준으로 하류지점에 대해서는 인천 조위관측소의 조위자료를 사용하거나 하천정비기본계획상의 기점수위를 일괄적으로 적용하여 지점에 따른 수위의 차이를 적용하지 못하는 한계를 지닌다. 따라서 본 연구에서는 남북접경지역 접근의 어려움으로 인하여 발생되는 한강하구 흐름해석의 불확실성을 명확히 하기 위한 방안으로 한강하구지역에 해당 군부대와 군사정전위원회의 출입허가 승인을 얻어 현장조사를 실시하였다. 사전조사를 통하여 성동교, 대산교, 공릉천, 화도돈대, 철곶돈대 전방 수변, 애기봉전망대 전방 수변을 조사 지점으로 선정하였다. 기존 연구에서는 한강하구의 공릉천 합류부 지점을 하류경계조건으로 채택하고 있으나, 현장조사를 통하여 얻을 자료를 분석한 결과 공릉천 합류부 지점의 수위는 강우발생에 대한 하천의 영향을 받는 것으로 나타나 하류경계조건으로 적정하지 않은 것으로 판단되었으며, 공릉천보다 하류지역에 위치한 지역에 대하여 하류경계조건으로 적정한 지역을 찾을 수 있었다. 수치해석 시에는 공간적 범위와 연구의 목적을 고려하여 각 지점의 실제 관측 자료를 활용한 경계조건을 사용하는 것이 적합한 것으로 판단되며 보다 많은 현장조사와 특성분석을 통한 정확한 경계조건의 구축이 필요할 것으로 사료된다.

  • PDF

In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology (음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.315-322
    • /
    • 2008
  • Valves in power plants are leaking internally by various damages including insertion of foreign objects on seat, seat crack, defects and fatigue crack of stem packing or welds etc. due to severe operating conditions such as high temperature and high pressure for extended period time. Acoustic emission(AE) technology should be applied in order to diagnose precisely and evaluate these valve internal leak. In this paper, results of studies which have accomplished in actual power plant are presented. We have analyzed background noise, AE signal level and frequency spectrum through laboratory tests on the basis of various actual conditions in power plant, and also have considered evaluation methods on the background noise, AE properties and the detectable minimum leak rate according to valve leak conditions through comparing with results of field tests in power plant. As a result of these studies, we conformed that evaluation of internal leak conditions including discrimination of leak or not, and the detectable minimum leak rate is possible, and also it is expected to contribute to safe operation and prevention of energy loss in power plants.