• Title/Summary/Keyword: 허용값

Search Result 790, Processing Time 0.03 seconds

Application of Direct Analysis Method Considering Initial Imperfection Limitation (초기변형 허용값을 고려한 직접해석법 적용)

  • Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.487-495
    • /
    • 2013
  • As the first step to suggest effective ways of using direct analysis method considering current situations of construction fields in Korea, analytical approach is used to verify direct analysis method which adapts initial imperfection limitation of Korean specification of building construction. The main analytical variables are size of frames, axial load ratio, axial load distribution, value of notional loads, location of notional loads, and applied method of notional loads. The results show that the use of initial imperfection limitation of Korean specification, L/700 is suitable, and the recommendable method to use direct analysis method is applied notional loads based on L/700 as minimum lateral load at each story, even if B2 is less than 1.5 and lateral loads exist.

A Study on the Economical Design of Airport Low-Voltage Feeder Which is considering the Temperature Character (온도특성을 고려한 공항 저압간선의 경제적인 설계기법에 관한 연구)

  • 최홍규;조계술;송영주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.119-126
    • /
    • 2003
  • The size of low voltage level conductor cables can be installed with a long length just like a aviation field, shall be determined for considering the ampacity of cable and the drop of voltage for the power system. Therefore, The size of the conductor cables may be larger one for considering the tolerable voltage drop comparatively, although the allowable ampacity of the conductor cables may have a margin in comparison with the rated full load current In this case, the conductor cables' allowable ampacity will be very larger than the rated full load current and the generated heat of the conductor will be relatively downed. The conductor cables' alternating current resistance corrected with the maximum allowable temperature of the conductors, has been applied on the general formula for the calculating the voltage drop in determinating the size of low voltage level conductor cables, and the resistance is larger than the resistance corrected with the actual temperature of the conductor cables. This paper was studied for the purpose of the conductor resistance corrected with the actual temperature rise of the conductor and address the economic design formula so that this studies shall minimize the errors which can be occurred in comparison with the general formula and which can be applied in design work for determining the size of low voltage level conductor cables.

붓스트랩 방법에 의한 95/95 확률 및 신뢰도를 갖는 허용구간의 포함확률 보정

  • Lee, Yun-Hui;Kim, Hong-Gi;Sin, Hui-Seong;Kim, Ho-Dong
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2003.05a
    • /
    • pp.249-254
    • /
    • 2003
  • 붓스트랩 기법에 의한 k 인자 허용구간방법을 95/95 확률 및 신뢰도를 갖는 허용구간에 활용하기 위하여 모의실험을 수행하였다. 그 결과 소표본 및 적당한 크기의 표본에서 추정된 신뢰도값은 실제 신뢰도값 95와 약 6${\sim}$21% 정도의 차이를 나타냈고, 이 차이는 표본크기가 커질수록 점점 줄어들었다. 더불어 기존방법에 보간법 등을 가미한 방법들을 제안하여 이들에 의한 결과를 기존결과와 비교하였다.

  • PDF

Study on Leakage Current and Insulation Resistance Effect of Temperature and Humidity (온도, 습도의 누설전류와 절연저항 영향 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.370-374
    • /
    • 2019
  • It was found that temperature and humidity did not affect the leakage current since the leakage current was irregularly increased or decreased at a temperature of $22^{\circ}C$ to $32^{\circ}C$ and a humidity of 60.0% to 96.0%. The insulation resistance in the vicinity of $26^{\circ}C$ was $10.70M{\Omega}$ to $4,000.00M{\Omega}$ and was low from $9.10M{\Omega}$ to $1,000.00M{\Omega}$ before and after $26^{\circ}C$. As the humidity was increase in a range of 60%~96%, the insulation resistance was reduced from $4,000.00M{\Omega}$ to $4.80M{\Omega}$, which indicates that the temperature and humidity had an influence on the insulation resistance. The leakage current and the insulation resistance of the branch circuit to the cooking facilities were compliant with less than 1.00 mA and more than $0.20M{\Omega}$. Leakage current of 1.89 mA was non-compliant but the insulation resistance was compliant with the value of $65.00M{\Omega}$.

Fault Diagnosis and Tolerant Algorithm of Current Sensors for a High-Power Conversion System (대용량 전력변환 장치의 전류센서 고장진단 및 허용운전 기법)

  • Ko, Young-Jong;Elise, Margo;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.415-416
    • /
    • 2011
  • 본 논문은 계통연계형 전력변환 장치의 폐루프 제어에 이용되는 전류센서의 고장진단 및 허용운전 기법을 제안한다. 전류 센서에 고장이 발생하면, 정확한 출력전력제어가 불가능해져 품질이 저하될 뿐만 아니라 이에 대한 허용운전이 이루어지지 않으면 전체시스템의 운전을 중지해야 한다. 따라서 실시간 고장진단 및 허용운전 기법이 필요하다. 제안한 기법은 측정된 값과 추정 값의 비교를 통해 고장진단을 하고, 고장발생시 정상 센서에서 측정된 전류 값을 이용하여 허용운전을 한다. 10kW급 3병렬 전력 변환 시스템을 모의한 시뮬레이션을 통해 제안한 기법의 성능을 검증하였다.

  • PDF

A Design on neutron absorber and moderator for the content measurement of Asphalt (아스팔트 함량 측정을 위한 중성자 흡수체 및 감속재 설계)

  • Kim Ki-Joon
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In Korea, under the influence of the jurisdiction, usage of radioisotopes are limited. The limitation is $100[{\mu}Ci]$ or less. Therefore, in this study, basic data were designed, and the following data are needed in order to improve content measuring instrument which is suitable for radioisotopes limitation. Owing to the source and detector's properties, measuring instrument was designed geometrically, neutron and photon's particle transportation was analysed by using the MCNP code which is in Monte Carlo Method, also the location of source and detectors, geometrical structure of neutron absorber and moderator was designed.

  • PDF

Evaluation of Hygienic Status of University Foodservice Operation using ATP bioluminescence Assay (ATP bioluminescence Assay를 이용한 대학 급식시설의 위생상태 평가에 관한 연구)

  • 박영숙
    • Korean journal of food and cookery science
    • /
    • v.16 no.2
    • /
    • pp.195-201
    • /
    • 2000
  • An investigation was conducted to evaluate the hygienic status of university foodservice operation by using conventional swabbing technique plus standard plate count and ATP bioluminescence assay. The results of the study were as follows: 1) For all kitchen boards, knives, feeding trays, and dish towels tested, there was an overall agreement at 84.7% level between the results obtained using ATP bioluminescence and plate count when using a pass/fail cut-off of 3$\times$ control values for ATP assay and 40 CFU(colony forming unit)/㎠ for plate count. 2) The agrement rate between ATP assay and standard plate count was 87.5% for the samples before use, 29.2% for those during use, and 42.7% for those after cleaning and sanitizing. 3) The plate counts of three university foodservice operations for kitchen board, kitchen knife, feeding tray and dish towel were within the acceptable limits when tested before using. However, none of them were within the acceptable limits when tested during using and after cleaning and sanitizing. 4) Above results suggested that an immediate action needs to be taken to reduce the potential danger of cross-contamination and also effective sanitary control methods needs to be developed to improve the sanitary condition.

  • PDF

The Software Classification by the Tolerance Rough Set (허용적 러프집합에 의한 소프트웨어 분류)

  • 김성애;최완규;이성주
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.2
    • /
    • pp.141-147
    • /
    • 2001
  • 소프트웨어의 측정값에 근거하여 소프트웨어 품질에 관한 의사결정을 할 때, 동치관계의 요구조건인 추이적(transitive) 특성이 항상 만족되는 것은 아니다. 순환수(cyclomatic number)가 거의 비슷한 프로그램에서, 하나의 \"구조적인\" 프로그램 범주에 속하고 또 다른 하나는 \"비구조적인\" 프로그램 범주에 속한다고 명확히 분류할 수 있는가하는 점이다. 따라서, 본 연구에서는 동치관계보다는 허용적 관계를 만족하는 허용적 러프집합에 근거한 소프트웨어 분류기준을 제시하고자 한다. 분류기준을 생성하기 위한 실험 데이터 집합을 수집하고, 집합 내의 각 원소에 관한 허용적 클래스들을 생성한 후, 각 허용적 클래스들의 중심값을 클러스터링하여 분류기준을 생성한다. 생성된 분류기준을 또 다른 실험 집합에 적용하여 비교 분석한 결과 생성된 분류기준이 타당함을 보여준다.생성된 분류기준이 타당함을 보여준다.

  • PDF

The Software Classification Criteria based on the Tolerant Rough Set (허용적 러프집합에 기반한 소프트웨어 분류기준)

  • 김상용;최완규;김영식;이성주
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.05a
    • /
    • pp.307-310
    • /
    • 2000
  • 소프트웨어의 측정값에 근거하여 소프트웨어 품질에 관한 의사결정을 할 때, 동치관계의 요구조건인 추이적(transitive) 특성이 항상 만족되는 것은 아니다. 순환수(cyclomatic number)가 거의 비슷한 프로그램에서, 하나는 "구조적인" 프로그램 범주에 속하고 또 다른 하나는 비구조적인 프로그램 범주에 속한다고 명확히 분류 할 수 있는가하는 점이다. 따라서, 본 연구에서는 동치관계보다는 허용적 관계를 만족하는 허용적 러프집합에 근거한 소프트웨어 분류 기준 제시하고자 한다. 분류기준을 생성하기 위한 실험 데이터 집합을 수집하고, 집합 내의 각 원소에 관한 허용적 클래스들을 생성한 후, 각 허용적 클래스들의 중심값을 클러스터링하여 분류기준을 생성한다. 생성된 분류기준을 또 다른 실험 집합에 적용하여 비교 분석하여 생성된 분류기준이 타당함을 보여준다.

  • PDF

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF