• Title/Summary/Keyword: 핵-핵 일치

Search Result 199, Processing Time 0.028 seconds

Comprehension and Appropriate Use of a Flood Table on a Gamma Camera (감마 카메라의 Flood Table에 대한 이해와 적절한 이용)

  • Kim, Jae-Il;Im, Jeong-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • Background and Purpose: Uniformity is the one of the important quality control features with respect to gamma cameras. To maintain adequate uniformity, we must acquire suitable flood table (=flood map) data because the flood table effects energy, and the type or dose of input radiation. Therefore, in this study we evaluated the difference in uniformity when uniformity does not match between the type of input radiation and the flood table data or collimator type. Subjects and Methods: For input radiation, we prepared 370 MBq of $^{57}Co$, $^{99m}Tc$, and $^{201}Tl$. Using SKYLight (Philips) and Infinia gamma cameras (GE), we acquired nine uniformity data that were corrected by technetium, cobalt flood table and did not corrected image for the three sources. Additionally, we acquired two uniformity images with a collimator that were corrected by intrinsic and extrinsic flood tables. Using this data, we evaluated and compared the uniformity values. Results: In the case of the SKYLight gamma camera, the uniformities of the images that matched between the input radiation and flood table with respect to $^{99m}Tc$ and $^{57}Co$ were better than the unmatched uniformity (3.96% vs. 5.69% ; 4.9% vs. 5.91%). However, because there was no thallium flood table, the uniformities of images at Tl were significantly incorrect (7.49%, 7.03%). The uniformities of the Infinia gamma camera had the same pattern as the SKYLight gamma camera (3.7% vs. 4.5%). Moreover, the uniformity of the $^{99m}Tc$ image acquired with a collimator and corrected by an extrinsic flood table was better than the intrinsic flood table (3.96% vs. 6.28%). Conclusion: Correcting an image by a suitable flood table can help achieve better uniformity for a gamma camera. Therefore, we have to acquire images with suitable uniformity correction, and update the flood table periodically. Whenever we acquire a nuclear medicine image, we always have to check the appropriate flood table according to the acquired condition.

  • PDF

Clinical Utility of Bone Scan in the Diagnosis of Temporomandibular Disorders (측두하악장애의 진단에서 Bone Scan의 유용성)

  • Kim, In-Joo;Kang, Yang-Ho;Son, Seok-Man;Lee, Kyoung-Seog;Lee, Jae-Bok;Kim, Yong-Ki;Seo, Bong-Jik;Park, June-Sang;Ko, Myung-Yun;Son, Seong-Pyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.511-517
    • /
    • 1995
  • Bone scan is a very sensitive diagnostic imaging test for detecting bone and joint disorders. So it might be useful in the diagnosis of temporomandibular disorders of the joint origin. Thus, the effectiveness of bone scan for detecting temporomandibular joint(TMJ) diseases and differentiating the TMJ disc displacement from the TMJ arthritis was evaluated. Bone scan was done in 21 patients with TMJ disc displacement(13 unilaterally affected, 8 bilaterally affected), 25 patients with TMJ arthritis(23 unilateral, 3 bilateral), and 39 volunteers with no signs, symtoms, or history of TMJ disease. TMJ simple uptake rate(SUR) and difference of both TMJ SUR were calculated from the 100,000 count lateral image of head and neck region in 99mTc MDP bone scan. Transcranial and panorama X-ray examination was also done in all patients. TMJ SUR(%) were $1.673{\pm}0.606$ in TMJs affected with arthritis, $1350{\pm}0.351$ in TMJs affected with disc displacement, and $1.084{\pm}0.172$ in TMJs of controls. Significant differences were demonstrated among them(p<0.01) Difference of bith TMJ SUR was highest in patients with unilateral TMJ arthritis($0.608{\pm}$0.533, p<001), and there is no significant difference between that of controls and that of unilateral TMJ dist displacement patients($0.062{\pm}0.063$ vs $0.122{\pm}0.100$). TMJ SUR of Joint with bone change on X-ray finding was not significantly different from that of joint with normal X-ray finding. Those in patients with unilateral TMJ disc displacement(696% and 87% vs 23.1% and 23%). The proportions of patients with increased TMJ SUR and difference of both TMJ SUR(>mean+2SD of controls) in unilateral TMJ arthritis patients were significantly higher than those in patients with unilateral TMJ disc displacement(69.6% and 87% vs 23.1% and 23%). Conclusively, bone scan nay help to detect TMJ disease and differentiate TMJ disc displacement from TMJ arthritis.

  • PDF

Role of Redistribution and 24 Hour Reinjection Images to assess Myocardial Viability in Patients with Acute Myocardial Infarction (급성심근경색환자의 심근생존능 평가에 있어서 T1-201 재분포영상과 24시간 재주사영상의 역할)

  • Yoon, Seok-Nam;Pai, Moon-Sun;Park, Chan-H.;Yoo Myung-Ho;Choi, Byung-Il William
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.325-331
    • /
    • 1998
  • Purpose: We evaluated the importance of redistribution and 24 hour reinjection images in T1-201 SPECT assessment of myocardial viability after acute myocardial infarction (AMI). Materials and Methods: We performed dipyridamole stress-4 hour redistribution-24 hour reinjection T1-201 SPECT in 43 patients with recent AMI (4-16 days). The myocardium was divided into 16 segments and perfusion grade was measured visually with 4 point score from 0 to 3 (absent uptake to normal uptake). A perfusion defect with stress score 2 was considered moderate. A defect was considered severe if the stress score was 0 or 1 (absent uptake or severe perfusion decrease). Moderate defect on stress image were considered viable and segments with severe defect were considered viable if they showed improvement of 1 score or more on redistribution or reinjection images. We compared the results of viability assessment in stress-redistribution and stress-reinjection images. Results: On visual analysis, 344 of 688 segments (50%) had abnormal perfusion. Fifty two (15%) had moderate perfusion defects and 292 (85%) had severe perfusion defects on stress image. Of 292 severe stress defects, 53 were irreversible on redistribution and reversible on reinjection images, and 15 were reversible on redistribution and irreversible on reinjection images. Two hundred twenty four of 292 segments (76.7%) showed concordant results on stress-redistribution and stress-reinjection images. Therefore 24 hour reinjection image changed viability status from necrotic to viable in 53 segments of 292 severe stress defect (18%). However, myocardial viability was underestimated in only 5% (15/292) of severe defects by 24 hour reinjection. Conclusion: The 24 hour reinjection imaging is useful in the assessment of myocardial viability. It is more sensitive than 4 hour redistribution imaging. However, both redistribution and reinjection images are needed since they complement each other.

  • PDF

Comparison of I-131 Scintigraphy, T1-201 Scintigraphy, and Serum Thyroglobulin in the Postoperative Follow-Up of Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과관찰에서 I-131 스캔, T1-201 스캔 및 혈청 갑상선 글로불린 농도의 비교)

  • Lee, Hyun-Kyung;Song, Jae-Soon;Shinn, Joon-Jae;You, Kye-Hwa;Cha, Wang-Ki;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.346-355
    • /
    • 1997
  • To evaluate the utility of I-131, T1-201 scintigraphy, and serum thyroglobulin(Tg) in the follow-up of differentiated thyroid cancer, we compared retrospectively the data from 33 patients who underwent total or subtotal thyroidectomy. I-131 scintigraphy was performed after optimal endogenous TSH stimulation ($TSH>50{\mu}U/ml$). Total 41 cases of I-131 and T1-201 scintigraphy pairs were examined. Concomitant serum thyroglobulin levels were measured for 41 pairs of scan. Tg-off levels(that measured after discontinuation of the thyroid hormone) higher than 40ng/m1 were considered positive, and Tg-on levels(that measured during the thyroid hormone replacement) higher than 5ng/ml were considered positive. The concordance rates between I-131 therapeutic scintigraphy and T1-201 scintigraphy was 48% in the 38 case of total scan pairs(59% in the 17 cases of postoperative preablation group, and 38% in the 21 cases of postoperative postablation group). Of 17 studies before the I-131 ablation therapy(preablation group), 7 showed positive I-131 therapeutic scintigraphy despite of negative T1-201 scintigraphy. Among patients with negative I-131 therapeutic scintigraphy, no patients had abnormal T1-201 uptake. However, of 21 studies which were done after radioiodine therapy(postablation group) 6 had abnormal uptake on T1-201 scintigraphy which were not seen on I-131 therapeutic scintigraphy, and Tg-off levels also elevated in this 4 of 6 cases. As a result, I-131 therapeutic scintigraphy showed highest positive rate at postoperative preablation follow-up study in differentiated thyroid cancer patients. T1-201 scintigraphy may be useful in postablation studies, and the use of the combined modalities(T1-201 and Tg levels) provides a higher diagnostic yield.

  • PDF

Annually Reproductive Cycles of Gonadotropic Cells, Endocrine Materials and Plasma Components in Special Relation to Oogenesis in Rainbow Trout, Oncorhynchus mykiss (번식주기에 있어서 자성무지개송어 (Oncorhynchus mykiss) 뇌하수체의 생식소자극호르몬 분비세포와 난형성에 특이하게 작용하는 내분비물질 및 혈장성분의 연중변화)

  • Yoon, Jong-Man;Kim, Gye-Woong;Park, Kwan-Ha
    • Applied Microscopy
    • /
    • v.31 no.1
    • /
    • pp.19-35
    • /
    • 2001
  • Outlines for plasma $estradiol-17\beta$, components, electrophoretic patterns, and ultrastructural changes were obtained in female rainbow trout (Oncorhynchus mykiss) during the seasonal reproductive cycles. Plasma $estradiol-17\beta$ under the natural conditions, exhibited distinct seasonal variation, peaking very late in vitellogenic season during September, decreasing gradually the halt of spawning in December, and ultimately falling during the early stages of seasonal ovarian recrudescence in February and March. This change in $estradiol-17\beta$ appeared to stimulate vitellogenin production as evidenced by increases in plasma calcium, phosphorus, glucose, albumin and total protein levels. The electrophoretic patterns of late maturing or spawning oocytes were stained more intensively than those of late perinucleolus oocytes (molecular weights of approximately 70,000 and 200,000). Two protein bands were found in the SDS-PAGE separation, coincident with the $estradiol-17\beta$ hormone peak. Gonadosomatic indices (GSI) significantly increased from October to January, and showed the highest peak in January, coinciding with the numerically abrupt increase of ripe ova in female. A positive correlation (r=0.701, p<0.01) was established between plasma $estradiol-17\beta$ levels and the gonadosomatic index during the prespawning. The highest level of hepatosomatic index (HSI) observed in December. During the breeding season (December), the gonadotropes were large and filled with GTH-containing inclusions such as granules and globules. The vitellogenic phase began as late perinurleolus oocytes became transformed into early maturing oocytes through the accumulation of yolk, and oocytes reached the late maturing stages as the ooplasm was completely packed with yolk. Marked ultrastructural changed in the granulosa cells during nuclear migration involve the dilation of the rough endoplasmic reticulum and the appearance of the rod-shaped mitochondria with tubular cristae. Microvilli (finger-like projections), from the zona radiata and from the oocyte grew, and made contact with each other in the pore canals of the zona radials during vitellogenesis, but were withdrawn as the zona radiata became more compact and devoid of pore canals during oocyte maturation. The zona radiata grew to a tripartite structure such as an outer thin homogeneous layer, and two inner thick helicoidal layers (zona radials interna and zona radiata externa). Under the normal conditions, the ovarian follicle influenced the histological development and periodical secretion of the hormones , sufficient for a oogenesis and gonadal steroid production.

  • PDF

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.

Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay (핵의학 체외 검사에서 자동분주기를 이용한 Random Assay 가능성평가)

  • Moon, Seung-Hwan;Lee, Ho-Young;Shin, Sun-Young;Min, Gyeong-Sun;Lee, Hyun-Joo;Jang, Su-Jin;Kang, Ji-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.323-329
    • /
    • 2009
  • Purpose: Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. Materials and Methods: The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. Results: The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2$\pm$1.7%, 3.9$\pm$2.1%, 7.1$\pm$6.2%, 11.2$\pm$7.2%. The CVs by random assay were 2.1$\pm$1.7%, 4.8$\pm$3.1%, 3.6$\pm$4.8%, and 7.4$\pm$6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). Conclusion: The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay.

Oestrogenic Activity of Parabens in Uterotrophic Assay (자궁비대시험 연구에서 에틸, 프로필, 이소프로필, 부틸, 이소부틸 파라벤의 내분비독성)

  • Jo Eun-Hye;Jung Ji-Youn;Park Cheol-Beom;Park Sun-Hee;Shim Yhong-Hee;Kang Dae-Hyuck;Lee Sung-Ho;Yu Jong-Hoon;Kim Sun-Jung;Lee Sung-Hoon;Park Jung-Ran;Lee Yong-Soon;Kang Kyung-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.2
    • /
    • pp.118-128
    • /
    • 2006
  • This study was conducted to determination of the endocrine distruptor function of 'Parabens' by dosing ethyl paraben, propyl paraben, isopropyl paraben, butyl paraben and isobutyl paraben to the immature SD rats. 18 groups were given vehicle control group, negative control group (Dibutyl phthalate), postive control group ($1'7-{\alpha}$ Ethynylestrdiol) and each paraben groups involved 3 dose level. Rats were injected with 62.5, 250 and 1,000mg/kg from postnatal day 19 till 21 once a day in subcutaneous and a total 3, times. There was no treatment related death. but, subcutaneous nodule, edema, alopecia and scrub formation on injection site was observed. These signs was become worse in high dose level. these signs was cause from physical stimulation by test substance which parabens were mix with com oil as vehicle. In the analysis of organ weights, absolute and relative weights of brain, spleen, liver, thymus, heart, kidneys, adrenals, ovaries and vagina were no difference with control group. but, wet and blotted weight of uterus was increased in every high dose parabens treat group. Especially, all dose level of isobutyl paraben was showed increment of uterus weight. uterus dilatation of parabens treated group was observed in gross anatomic pathology and these result was agree with wet and blotted weight of uterus. In the result of this study, estrogenic effect as endocrine distruptor was observed in ethyl paraben, propyl paraben, isopropyl paraben, butyl paraben and isobutyl paraben. and it was considered isobutyl paraben has highest estrogrnic effect under the condition of this study.

Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program (게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교)

  • Jeong, Young-Jin;Park, Tae-Ho;Cha, Kwang-Soo;Kim, Moo-Hyun;Kim, Young-Dae;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.430-437
    • /
    • 2005
  • Purpose: The objectives of this study were - First, to determine the normal range of left ventricular end diastolic volume (EDV), end systolic volume (ESV) and election fraction (EF) from gated myocardial perfusion SPECT for Quantitative Gated SPECT (QGS) and 4D-MSPECT (4DM), respectively. Second, to evaluate the relationships between values produced by both software packages. Materials & Methods: Tc-99m MIBI gated myocardial perfusion SPECT were performed for 77 patients (mean age: $49.6{\pm}13.7y$, n=37(M), 40(F)) with a low likelihood (<10%) of coronary artery disease (CAD) using dual head gamma camera (E.CAM, Siemens, USA). Left ventricular EDV, ESV and EF were automatically measured by means of QGS and 4DM, respectively. Results: in QGS, the mean EDV, ESV and EF for all patients were $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml\;and\;66.6{\pm}8.0%$ at stress test respectively, not different from rest test (p>0.05). In 4DM, the mean EDV, ESV and EF for all patients were $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml\;and\;68.5{\pm}6.7%$ at stress test. Most cases in 4DM, there was no significant difference statistically between stress and rest test (p>0.05). But statistically significant difference was found in EF ($68.5{\pm}6.7%$ at stress vs $70.9{\pm}8.0%$ at rest, p<0.05). Correlation coefficients between the methods for EDV, ESV and EF were comparatively high (0.95, 0.93, 0.71 at stress test and 0.95, 0.90, 0.69 at rest test, respectively). However, Bland-Altman plots showed a large range of the limit value of agreement for EDV, ESV and EF between both methods ($-30ml{\sim}10ml,\;-12ml{\sim}8ml,\;-14%{\sim}11%$ at stress test and $-32ml{\sim}5ml,\;-13ml{\sim}13ml,\;-18%{\sim}12%$ at rest test). Conclusion: We found the normal ranges of EDV, ESV and EF for patients with a low likelihood of CAD in both methods. We expect these values will be a good reference to interpret gated myocardial perfusion SPECT. Although good correlation was observed between both methods, they should not be used interchangeably. Therefore, when both programs are used at the same site, it will be important to apply normal limits specific to each method.

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF