• Title/Summary/Keyword: 합성보 휨거동

Search Result 102, Processing Time 0.025 seconds

Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Steel Girder (강섬유로 보강된 초고성능 콘크리트 바닥판과 역T형 강거더 합성보의 휨거동 실험)

  • Yoo, Sung-Won;Ahn, Young-Sun;Cha, Yeong-Dal;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.761-769
    • /
    • 2014
  • Ultra high performance concrete (UHPC) has been developed to overcome the low strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.

Verification of experimental test for PSC-Steel-PSC hybrid beam using nonlinear FEM analysis (비선형 FEM 해석을 이용한 PSC-Steel-PSC 혼합구조 보의 휨 실험 검증)

  • Kim, Sang-Hyo;Won, Jung-Hun;Park, Se-Jun;Lee, Chan-Gu
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.517-520
    • /
    • 2009
  • 본 연구에서는 비선형 FEM 해석을 이용하여 PSC(Prestressed concrete)와 강으로 구성된 혼합구조 보의 휨 실험을 검증하였다. 혼합구조 보의 거동에 가장 큰 영향을 미치는 연결부는 Perfobond rib로 구성된 경우와 스터드로 구성된 경우를 고려하였다. 이종 재료가 접하는 경계면의 상호 작용에 대해 완전합성과 부분합성인 경우를 고려하여 혼합구조 보의 비선형 해석을 수행한 후 해석 결과와 실험 결과를 비교하였다. 하중-처짐관계, 파괴 형상 등의 해석 결과를 실험 결과와 비교한 결과, 부분합성을 고려한 모형이 실험 결과와 유사한 거동을 보였으며 또한 Perfobond rib를 갖는 실험체가 스터드를 갖는 실험체보다 해석 결과와 비교 시 안전측의 결과를 나타냈다.

  • PDF

Static Behavior of Steel-Concrete Composite Beam with Perfobond Rib Shear Connector (Perfobond rib 전단연결재가 설치된 강.콘크리트 합성보의 정적거동)

  • Ahn, Jin Hee;Chung, Hamin;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.421-432
    • /
    • 2009
  • In this study, push-out and static loading tests were conducted to evaluate the behavioral characteristics of composite beams with a perfobond rib shear connector. The shear capacity of the perfobond rib was found to be proportional to its concrete strength, which is in turn affected by the increase in the concrete end-bearing strength and concrete dowel action to resist the shear force. The relative slips of the push-out specimen, however, which was used to assess the ductility of the shear connector, increased to some extent, but it no longer increased when it reached the critical concrete strength because of the flexibility of the transverse rebar in the rib hole. The static-loading-test results revealed a crack on the concrete slab in the composite beam with a perfobond rib on the side of the rib hole and transverse rebar for the applied moment and shear force to the rib hole, depending on the static loading. The shear resistance characteristics of the perfobond rib shear connector were found to resist the shear force from the relative slip on the interface of the composite beam. Thus, the sectional effect of the shear connector to the composite beam with a perfobond rib should be considered when designing the composite beam because the behavior of the composite beam can change owing to the shear connector.

Interface Behavior of Concrete Infilled Steel Tube Composite Beam (콘크리트충전 강관 합성보의 계면거동)

  • Lee, Yong-Hak;Lee, Ta;Jeong, Jong-Hyeon;Kim, Hyeong-Ju;Park, Kun-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.9-18
    • /
    • 2014
  • Interface behavior and confining effects of concrete-infilled steel tube (CFT) composite beam were investigate based on the experimental observations and numerical analyses. For this purpose, laboratory four-points bending tests were performed for the two test specimens of 1,000mm long CFT composite beams. The test beams were made of ${\phi}110mm$ and 4.5mm thick steel tube and 10mm thick steel web and bottom flange. Therefore, concrete infilled in steel tube was in compression through the entire cross section due to the web and bottom flange. Two end section conditions, with end section cap and without end section cap, were considered in experiments to monitor the relative slip displacement at ends and induce confining effects at center. In numerical aspects, finite element analysis considering steel-concrete interface behavior was performed and compared to the experimental results.

Structural Behavior of Newly Developed Cold-Formed Steel Sections(II) - Flexural Behavior (신형상 냉간성형 단면의 구조적 거동(II) - 휨거동)

  • Song, In Seop;Kim, Gap Deuk;Kwon, Young Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.357-364
    • /
    • 2002
  • The study performed a series of flexural tests on Closed Cold-Formed Steel Sections for stud, joist, and roof truss. Results were compared with analytical values. Each 2.4-m long and 0.9-m wide specimen consisted of two steel beams set at 0.46 m interval. The steel beams were attached to the specimens using either plaster board or ply wood. Another specimens did not use any attachment material. Positive and negative bending tests were conducted to investigate the composite behavior, including the effects of plaster board or ply wood on the buckling behavior of steel beam. Full-scale roof truss tests were also performed to study the buckling behavior and failure mode of the truss members.

Programming of Beam/Column Analytical Process for Composite Wall Panels (냉간성형강 스터드 합성벽 패널의 보/기둥 해석기법의 전산화)

  • Lee, Young Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.45-52
    • /
    • 2005
  • The object of this study was a cold-formed steel wall stud panel sheathed by gypsum boards. In the beam-analysis, the panel was treated as a simple beam with a uniform lateral loading. The deflections were calculated by considering the primary factors that reduced the stiffness of the panel. In the column-analysis, the panel was treated as a bearing wall with an axial load. By using an energy method, nominal axial strength could be evaluated by considering both flexural buckling and torsional-flexural buckling. All calculations were programmed and compared with the results of the experiment. In the beam-analysis, experimental deflections were close to theoretical deflections. In the column-analysis, the experimental values were also close to theoretical values in axial strength.

Bending Capacity Evaluation of the Infilled Composite Beam with Semi-slim Closed Section (반슬림 폐단면 충전형 합성보의 휨성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.130-140
    • /
    • 2018
  • An AU-composite beam based on U-shaped steel beams and steel plate anchors of type A was developed. The composite beam reduced the height of the building floor and construction cost. In addition, it decreased the length of construction work, and improved the flexural strength and stiffness as a form of tubes. In this study, AU-composite beams were tested directly and their performance was evaluated through bending experiments. The strength of the specimens was increased initially by linear loads and reached a maximum strength due to destruction of the concrete slab. All of the experiments showed more than 85% of the maximum stress and performed gentle movement. In addition, there was good composite behavior with the steel plate anchor that had excellent composite effects and reached full strength until the maximum strength was reached. When the thickness of the steel plate was increase, the flexural stiffness and strength of the specimen were improved. Therefore, the flexural strength of AU-composite beams can be estimated using the flexural strength formula according to the KBC 2016.

Flexural Capacity of the Composite Beam using Angle as a Shear Connector (앵글을 전단연결재로 사용하는 합성보의 휨성능)

  • Kim, Young Ju;Bae, Jae Hoon;Ahn, Tae Sang;Choi, Jong Gwon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.63-75
    • /
    • 2015
  • In this study, Composite beam flexural capacity was investigated experimentally using angle as a shear connector. The main experimental parameters are the size and the spacing of the angle and the overall behavior of before and after composite. Also, the composite beam bending performance when it used with hollow PC slab and the general RC slab was compared. When determining that it synthetically, the flexural capacity of the composite beam with angle shear connector estimated 25% to 55% more strength than the nominal strength. Effects of strength parameters of composite beam by angles shear connector are size and spacing of the angle. As expected, the larger and the narrower spacing of the angles, the more strength the composite beam have. In addition, the performance of the composite beam with a hollow slab was well demonstrated by the test.

Bending Tests of H steel-Partial Concrete Incased Composite Beams (H형강-국부 콘크리트 합성보지 휨 실험)

  • Kim, Sung-Hoon;Kim, Dae-Kon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.77-85
    • /
    • 2005
  • After the collapse of the World Trade Center in september 11, 2001 and due to the frequent fire-caused damages of buildings during earthquake attacks, social concerns have been increased for the fire proof of the structural members of buildings. Recently, researches have been conducted to improve the fire resistance for building members not by the traditional ways but by utilizing the fire-resisting characteristics of reinforced concrete and structural characteristics of H-steel. In this paper, laboratory tests were conducted in room temperature to investigate the structural performance of the composite beams, which were developed to improve the fire resistance, comprising with concrete incasement between upper and lower flanges of H steel. From the experimental results, the displacement ductility factors of $6\~8$ were obtained. The difference of flexural behavior ol H steel-partial concrete incased composite beams with various composite details seems to be minor. The amount of longitudinal rebars is the most influential factor for the flexural strength of the composite beams. Therefore, if this type of composite beams are selected for designing a building located in moderate seismic lone, identical beam size could be used in several stories of the building.

Explicit Nonlinear Finite Element Analysis for Flexure Behavior of FRP-Concrete Composite Beam (FRP-콘크리트 합성보의 휨거동에 관한 외연적 비선형 유한요소해석 연구)

  • Yoo, Seung Woon;Kang, Ga Ram
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.269-276
    • /
    • 2017
  • In order to study ultimate flexure behavior of FRP-concrete composite structures which can replace reinforced concrete structures, ABAQUS, a general purpose analysis program, was utilized for numerical nonlinear analysis of structural performance and behavior characteristics of FRP-concrete composite beams. Explicit nonlinear finite element analysis was conducted and the numerical results were compared with previous experiments. Concrete damaged plasticity model was adopted as material properties of concrete and Euro code was used as compressive stress state. Nonlinear analysis was performed for four different types of FRP-concrete composite beams, and ultimate load and cracking pattern was compared and analyzed. The model suggested in this research was able to simulate ultimate load and cracking pattern properly, it is expected to be utilized in study of precise structural and behavioral characteristics of various FRP-concrete composite structures.