DOI QR코드

DOI QR Code

Flexural Capacity of the Composite Beam using Angle as a Shear Connector

앵글을 전단연결재로 사용하는 합성보의 휨성능

  • Kim, Young Ju (Construction Engineering Center, DRB Holding Co., Ltd.) ;
  • Bae, Jae Hoon (Construction Engineering Center, DRB Holding Co., Ltd.) ;
  • Ahn, Tae Sang (Construction Engineering Center, DRB Holding Co., Ltd.) ;
  • Choi, Jong Gwon (Architectural Construction Engineering Team, GS E&C)
  • Received : 2014.08.25
  • Accepted : 2014.12.29
  • Published : 2015.02.27

Abstract

In this study, Composite beam flexural capacity was investigated experimentally using angle as a shear connector. The main experimental parameters are the size and the spacing of the angle and the overall behavior of before and after composite. Also, the composite beam bending performance when it used with hollow PC slab and the general RC slab was compared. When determining that it synthetically, the flexural capacity of the composite beam with angle shear connector estimated 25% to 55% more strength than the nominal strength. Effects of strength parameters of composite beam by angles shear connector are size and spacing of the angle. As expected, the larger and the narrower spacing of the angles, the more strength the composite beam have. In addition, the performance of the composite beam with a hollow slab was well demonstrated by the test.

본 연구에서는 앵글을 전단연결재로 사용하여 합성보의 휨성능을 실험적으로 조사하였다. 실험의 주요변수는 앵글의 크기와 간격 및 콘크리트가 합성 전과 합성 후의 휨에 대한 전체적인 거동을 실험적으로 검증하였다. 또한 중공PC슬래브와 일반RC슬래브와 같이 사용하였을 때의 휨성능을 비교하였다. 이를 종합적으로 판단하면, 앵글을 전단연결재로 사용한 합성보의 휨성능은 앵글의 간격을 적절하게 배치시키면 예상내력보다 25-55% 이상의 공칭내력을 보유하고 있음을 확인할 수 있었다. 예상한 바와 같이, 합성보의 내력에 미치는 앵글의 변수를 살펴보면 앵글의 크기가 클수록 앵글의 간격이 좁을수록 합성보의 내력이 상승함을 확인할 수 있었다. 또한 중공PC슬래브에서도 앵글을 사용한 합성보의 성능이 잘 발휘됨을 실험적으로 검증하였다.

Keywords

References

  1. 김성배, 김상섭, 이원록, 김정연, 이승배, 유덕수, 김대회 (2012) 신형상 U형 하이브리드 합성보의 휨성능에 대한 연구, 한국강구조학회논문집, 한국강구조학회, 제24권, 제5호, pp.521-534. Kim, S.B., Kim, S.S., and Lee, W.R. (2012) Study on the Flexible Strength of U-shape Hybrid Composite Beam, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.5, pp.521-534 (in Korean).
  2. 류재호, 박세호, 주영규, 김상대(2011) GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가, 한국강구조학회논문집, 한국강구조하기회, 제23권, 제1호, pp.125-135. Ryu, J.H., Park, S.H., Ju, Y.K., and Kim, S.D. (2011) An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP, Journal of Korean Society of Steel Construction, KSSC, Vol.23, No.1, pp.125-135 (in Korean).
  3. 허병욱, 배규웅, 문태섭(2004) 매입형(슬림플로어) 합성보의 휨성능 평가 -춤이 깊은 데크플레이트와 비대칭 H형강청골보-, 한국강구조학회논문집, 한국강구조학회, 제16권, 제2호, pp.235-246. Heo, B.W., Bae, K.W., and Moon, T.S. (2004) Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate, Journal of Korean Society of Steel Construction, KSSC, Vol.16, No.2, pp.235-246 (in Korean).
  4. 김상섭, 박동수, 부윤섭(2012) 자중저감 철선일체형 중공데크플레이트 슬래브를 사용한 합성보의 휨내력 및 $CO_2$ 감소량 평가, 한국강구조학회논문집, 한국강구조학회, 제24권, 제3호, pp.5313-323. Kim, S.S., Park, D.S., and Boo, Y.S. (2012) Flexural Capacity and $CO_2$ Reduction Evaluation for Composite Beam with Weight Reducing Steel Wire-Integrated Void Deck Plate slab, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.3, pp.313-323 (in Korean).
  5. Slutter, R.G. and Driscoll, G.C. (1965) Flexural Strength of Steel-Concrete Composite Beams, Journal of the Structural Division, ASCE, Vol.91, No.ST 2.
  6. Viest, 1.M., Siess, C.P., Appleton, J.H., Newmark, N.M. (1952) Full Scale Ttests Of Channel Shear Connectors and Composite T-Beams, University of Illinois Bulletin No. 405.
  7. 이은택, 이상훈, 장보라(2008) 층고절감을 위한 반플림슬로어 합성보 휨성능 평가, 한국강구조학회논문집, 한국강구조하기회, 제20권, 제1호, pp.165-173. Lee, E.T., Lee, S.H., and Jang, B.R. (2004) Flexural Performance Evaluation of Semi-slim floor Composite Beams for Reduction of Story Height, Journal of Korean Society of Steel Construction, KSSC, Vol.20, No.1, pp. 165-173 (in Korean).
  8. Siess, C.P., Viest, I.M., and Newmark, N.M. (1952) Studies Of Slab Aad Beam Bridges, Part III - Small Scale Tests Of Shear Connectors And Composite T-beams, University of Illinois Bulletin No.396.
  9. Thurlirnann, B. (1958) Composite Beams With Stud Shear Connectors, Highway Research Board, National Academy of Science Bulletin No.174.
  10. CEN (2001) prEN 1994-1-1:2001: Draft No.2 of Eurocode 4, Design of Composite Steel and Concrete Structures Part 1.1: General Rules and Rules for Buildings, Comite Europeen de Normalisation (CEN), Brussels, Belgium.
  11. 김영주, 배재훈, 안태상, 장동운(2014) 합성보에 적용된 앵글 전단연결재의 Push-out 실험, 한국강구조학회논문집, 한국강구조학회, 제26권, 제3호, pp.155-167. Kim, Y.J., Bae, J.H., Ahn, T.S., and Jang, D.W. (2014) Push-out Test on Welded Angle Shear Connectors used in Composite Beams, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.1, pp.155-167 (in Korean).
  12. 김영주, 배재훈, 안태상, 김진원, 유홍식(2014) SRC기둥-H형단면과 U형단면으로 구성된 합성보 접합부의 반복가력실험, 한국강구조학회논문집, 한국강구조학회, 제26권, 제4호, pp.263-275. Kim, Y.J., Bae, J.H., Ahn, T.S., KIm, J.W., and Ryu, H.S. (2014) Cyclic Loading Test on Connection of SRC Column- Composite Beam Consisting of H-section and U-section Members, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.4, pp.263-275(in Korea).
  13. 김영주, 배재훈, 안태상, 장성훈(2014) 중력하중을 받는 SRC기둥-합성보 접합부 실험, 한국강구조학회논문집, 한국강구조학회, 제26권, 제5호, pp.441-452. Kim, Y.J., Bae, J.H., Ahn, T.S., and Jang, S.H. (2014) Test of SRC Column-to-Composite Beam Connection Under Gravity Loading, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.5, pp.441-452 (in Korea).
  14. 한국강구조학회(2011) 하중저항계수설계법에 의한 강구조설계기준 해설, 한국강구조학회. KSSC (2011) Korean Steel Structure Design Code and Commentary; Load and Resistance Factored Design, KSSC.
  15. AISC, Manual of Steel Construction : Load and Resistance Factor Design America Institute of Steel Construction.
  16. AISC, Partially Restrained Composite Connections : Load and Resistance Factor Design America Institute of Steel Construction.
  17. ANSI/ASCE (1985) Specifications for the Design and Construction of Composite Slabs and Commentary on Specifications for Design and Construction of Composite Slabs, American Society of Civil Engineers, p.56.
  18. 대한건축학회 (2009) 건축구조설계기준 및 해설(KBC2009), 기문당. AIK (2009) Korean Building Code and Commentary- Structural, Architectural Institute of Korea (in Korean).

Cited by

  1. 춤이 작은 신형상 고성능 하이브리드 합성보의 휨성능 평가 vol.28, pp.3, 2016, https://doi.org/10.7781/kjoss.2016.28.3.151
  2. 춤이 큰 고성능 하이브리드 합성보의 휨성능 평가 vol.28, pp.6, 2015, https://doi.org/10.7781/kjoss.2016.28.6.403
  3. 궤도 및 교량 안전성을 고려한 열차 증속가능 속도대역 평가 vol.33, pp.2, 2015, https://doi.org/10.14346/jkosos.2018.33.2.145
  4. Structural Performance Evaluation of Square-Shape Steel Column with Shear Connectors vol.31, pp.3, 2015, https://doi.org/10.7781/kjoss.2019.31.3.141
  5. Flexural Strength of Filled Composite Beams with Embossing Webs vol.31, pp.3, 2015, https://doi.org/10.7781/kjoss.2019.31.3.189
  6. Full-Scale Model Test on the Structural Behavior of U-Shaped Composite Bridge Reinforced with Arch Edge Girders vol.11, pp.1, 2020, https://doi.org/10.11004/kosacs.2020.11.1.025
  7. Seismic Performance Evaluation of the Connection Between the CFT Column with Built-up Square Shape Steel Tube (D-Column) and the HyFo Composite Beam vol.32, pp.1, 2015, https://doi.org/10.7781/kjoss.2020.32.1.043
  8. Evaluation of Tensile and Structural Performance of the External Diaphragm Joint on the Welding Detail of the Column with Built-up Square Shape Steel Tube vol.32, pp.5, 2015, https://doi.org/10.7781/kjoss.2020.32.5.331
  9. Strength Evaluation of Composite Beams with Embossing Webs by Concrete Freezing Damage vol.32, pp.6, 2020, https://doi.org/10.7781/kjoss.2020.32.6.341
  10. Evaluation of Flexural Performance of Composite Girder Consisting of Square Steel Pipes and Reinforced Lattice vol.33, pp.4, 2021, https://doi.org/10.7781/kjoss.2021.33.4.247
  11. Load Transfer Capacity of Bolt Type Shear Connectors for Small Sized CFT Member vol.33, pp.5, 2021, https://doi.org/10.7781/kjoss.2021.33.5.327