• Title/Summary/Keyword: 한국콘크리트 학회

Search Result 17,762, Processing Time 0.041 seconds

A Reaserch on the Performance Verification of Energy Storage Mortar Enhanced in Thermal Efficiency and Strength by Applying Microencapsulated Phase Change Materials and Nanomaterials (마이크로캡슐로 코팅한 상변화 물질과 나노소재를 적용한 고효율 열저장 시멘트 복합체 성능 검증 연구)

  • Ahn, Jun Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.433-441
    • /
    • 2024
  • This study aims to prevent freezing of existing domestic buildings by developing an energy storage mortar with increased energy efficiency that can reduce the increase in carbon emissions and maintenance costs due to external energy use due to heat wires in civil engineering and buildings with embedded heat wires. I suggest. Research has focused on incorporating phase change materials (PCMs) into common cement composites to provide latent heat performance. However, concrete mixed with phase change materials shows problems such as leakage of phase change materials, decreased strength, and insufficient thermal performance. To overcome this problem, we encapsulate phase change materials using microcapsules and mix them into cement composites to minimize strength loss and leakage, and use multi-walled carbon nanotubes and silica fume to minimize the strength reduction of concrete. A heat storage cement composite was developed. When high-efficiency heat storage cement was used as a replacement for ordinary cement composite in an environment where heat wires were buried, the effect was shown to reduce energy by about 42 %, and compared to a cement composite containing only PCM, the compressive strength and bending strength were 18 % and 23 %, respectively. was improved and its effectiveness was proven.

Performance Improvement and Durability Evaluation of Shotcrete for Permanent Tunnel Support (터널 영구 지보재로서의 숏크리트 고성능화 및 내구성 평가에 관한 연구)

  • Lee, Sang-Pil;Ryu, Jong-Hyun;Lee, Sang-Don;Jeon, Seok-Won;Lee, Chung-In
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.266-284
    • /
    • 2007
  • Recently, many efforts have been made to construct the first unlined tunnel, without in-situ concrete lining, in Korea. However, the lack of reliability in the performance of shotcrete as permanent tunnel support prevented from its realization. Shotcrete has been regarded to have significant problems in field application and long term performance because of unsatisfactory strength level and durability compared to those of European countries. In this study, the high strength shotcrete satisfying compressive strength over 40 MPa and flexural strength over 4.5 MPa was developed from optimized mix design. The type of accelerators and the amount of silica fume were selected as the main factors in mixing process and the analyses were carried out up to the elapsed time of 2 years. In order to evaluate the short term durability of shotcrete, an array of laboratory test consisting of freeze-thaw, carbonation chloride penetration and permeability test was performed. For long-term durability tests, specimens have been put in an operated highway tunnel to expose them to the similar environment when they are actually used as an unlined tunnel support. From the strength and durability tests, it was found that only alkali-free based accelerator satisfied the target strength of this study and also, the developed shotcrete showed very high performance in its durability.

Life Cycle Assessment of Timber Arch-Truss Bridge by Using Domestic Pinus rigida Glued-Laminated Timber (리기다소나무 구조용 집성재를 활용한 아치 트러스 목조교량의 전과정평가)

  • Son, Whi-Lim;Park, Joo-Saeng;Kim, Kwang-Mo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • This study carried out life cycle assessment for evaluating environmental impacts of timber Arch-Truss bridge by using domestic Pinus rigida Miller glued-laminated timber throughout life cycle such as extraction, manufacturing, transportation, construction, use, dismantlement, transportation of waste, disposal and recycling. The life cycle GHG (GreenHouse Gas) emissions of the target bridge are 192.56 ton $CO_2$ eq. in 50 years. Especially, the life cycle GHG emissions of concrete used in the target bridge are 82.84 ton $CO_2$ eq. which accounts for 53.02% of the GWP (Global Warming Potential) in extraction and manufacturing stages. The target bridge is constructed of $116.57m^3$ of domestic Pinus rigida Miller glued-laminated timber and used timber has stored 104.72 ton $CO_2$. If an effect of carbon storage in timber is applied to the total GHG emissions of the target bridge, the GHG emissions can be reduced by 54.38%. In the case of substitution effect, if domestic Pinus rigida Miller glued-laminated timber replaces steel manufactures used in other bridge which has the same structure and life span as the target bridge, the GHG emissions in extraction and manufacturing stages can be reduced by 10.26% to 23.91%.

Multi-Point Optical Fiber Grating Strain Sensor System (광섬유 격자 다중화 스트레인 센서 시스템)

  • Lee, Yong-Wook;Jung, Jae-Hoon;Chung, Seung-Hwan;Lee, Byoung-Ho;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2001
  • An optical fiber sensor is capable of nondestructive measurement of a structure and it has an advantage of the immunity to electromagnetic interference because light is not affected by electromagnetic wave. In addition, if optical fibers are buried in an object like a concrete, this sensor tan analyze defects and physical status of the object without disassembling it. Especially, the fiber Bragg grating sensor is a promising optical fiber sensor capable of nondestructive test of such an object. A fiber Bragg grating has the characteristics of reflecting or blotting light of a specific wavelength. If we apply physical quantity like strain to the fiber Bragg grating, the center wavelength of the reflected light is shifted and then we can find the physical quantity applied to the fiber Bragg grating by measuring the center wavelength shift of the reflected light. The fiber Bragg grating sensor capable ot static and dynamic strain measurement is being used in health-monitoring of buildings, structures, etc. Recently increasing is interest in dynamic strain measurement inevitable to the civil structures such as roads and bridges. In this study we implemented the optical fiber sensor system which can measure dynamic strain at multiple points using Fabry-Perot wavelength demodulation. And we measured the static and dynamic strain using this sensor system with a test structure(cantilever). Measurement results were similar to those obtained with the conventional electrical measurement methods.

  • PDF

A study on the safety improvement of above ground membrane LNG storage tank (상지상식 멤브레인 액화천연가스 저장탱크의 안전성 향상 방안)

  • Lee, Seung Rim;Kim, Han Sang
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.339-345
    • /
    • 2012
  • RMembrane LNG storage tanks have been recently investigated to replace full-containment LNG storage tanks because of safety and cost aspects. Quantitative Risk Analysis (QRA) and Finite Element Method (FEM) were used to evaluate safety of membrane LNG storage tanks. In this study, structural safety evaluation results via FEM analysis showed that both membrane type and full-containment type cryogenic LNG storage tanks with 140,000 $m^3$ capacity were equivalently safe in terms of strength safety and leakage safety of a storage tank system. Also, Fault Tree Analysis (FTA) was used to improve the safety of membrane LNG storage tanks and membrane LNG tanks were modified by adding three safety equipments: impact absorber structure for the low part of the membrane, the secondary barrier to diminish the thermal stress of the corner part of the outer tank, and a pump catcher in case of falling of a pump. Consequently, the safety of the modified membrane LNG storage tanks were proved to be equivalent to that of full-containment LNG storage tanks.

Nondestructive Deterioration Diagnosis for the Former Ore Dressing Plant in the Yongwha Mine of Registered Cultural Property No. 255 (등록문화재 제255호 영양 구 용화광산 선광장의 비파괴 훼손도 진단)

  • Chun, Yu Gun;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.28 no.3
    • /
    • pp.235-245
    • /
    • 2012
  • Nondestructive deterioration diagnosis has been carried out for the former ore dressing plant of the Yongwha mine in Yeongyang (Registered Cultural Property No. 255). Deterioration rates about organic contaminant and soil of the upper part (7 to 13 layer) indicate higher than the lower part (1 to 6 layer) of the ore dressing plants. By contrast, deterioration rates such as crack, break out and discoloration of the lower part indicate very higher than the upper part. It is estimated that the plants of the lower part that mechanical and chemical process had been done for flotation were damaged severely by physicochemical weathering with reaction of concrete and chemical solution. As results of ultrasonic velocity measurement, average p-wave velocity of plants were measured 2,462m/s (compressive strength $529kgf/cm^2$). As for the analytical results of surface contaminants and soil compositions using P-XRF, they were identical with major elements (Cu, Zn, Pb, Fe and As) of ore minerals from the Yongwha mine. Therefore, the ore dressing plant should be treated by phytoremediation with conservation because heavy metals could impinged upon plants and natural environment.

Concrete Degradation Comparison of Computer Programs for Post-Closure Safety Assessment of Wolsong Low-and Intermediate-Level Radioactive Waste Disposal Facility (월성원자력환경관리센터 폐쇄 후 안전평가 컴퓨터프로그램의 콘크리트 열화현상에 대한 상호비교)

  • Jung, Kang-Il;Bang, Je-Heon;Park, Jin Beak;Yoon, Jeong Hyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.4
    • /
    • pp.311-324
    • /
    • 2013
  • To ensure the reliability of computer programs used for the post-closure safety assessment in the Wolsong LILW Center, the results from MASCOT, SAFE-ROCK and GOLDSIM programs are compared with a problem for degradation. Advantages and disadvantages of each computer programs are individually analyzed. Effects on the individual dose are assessed with each computer programs. MASCOT and SAFE-ROCK showed similar results for $^{129}I$ and $^3H$. However, GOLDSIM represented different results for $^{129}I$ and $^3H$. It is analyzed further and compared with the fluxes in each barrier of the disposal system. Througout the benchmarking testing of the computer program, the limitation of computer program can be continuously found out for the mature post-closure safety of Korean radwaste disposal system.

Uplift Capacity of Spiral Bar through the Model Experiment (모형실험을 통한 스파이럴 기초의 인발저항력 검토)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Ha Neul;Lee, Si Young;Kang, Dong Hyeon;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.202-209
    • /
    • 2015
  • This study compared and analyzed the measurements of pullout load according to the depth of reclamation in the foundation, compaction ratio of soil, spiral diameter, and soil textures in an experiment with a model and reached the following conclusions: The comparison results of extreme pullout load between farm and reclaimed soil show that farmland soil recorded a score that was 1.2~3 times higher than that of reclaimed soil. The investigator measured pullout load in farmland and reclaimed soil and observed a tendency of rising extreme pullout load according to the increasing depth of reclamation and compaction ratio with a similar load-displacement curve between the two types of soil. Extreme pullout load made a greater increase by the rising size of diameter than the increasing depth of reclamation, also making a considerably bigger increase according to the rising compaction ratio than the other conditions. Therefore, the spirals bar is expected to be available in soft soil foundation, as well as farmland as increasing buried deep of foundations, compaction rate, diameter of the spiral, ect.

Deterioration and Conservation Treatment of the Three Storied Stone Pagoda in Seoak-ri, Gyeongju (경주 서악리 삼층석탑의 훼손상태 및 보존처리)

  • Lee, Myeong-Seong;Jeong, Min-Ho;Jung, Young-Dong;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.18 s.18
    • /
    • pp.63-74
    • /
    • 2006
  • All rock materials of the three storied stone pagoda in Seoakri were composed of light gray alkali granite with medium grained and developed with small mialolitic cavities. This stone pagoda is preserving almost archetype except the head part because there was repair work already. But, foundation, basement and roof rocks are serious state by microbial invasion such as lichens. Because there are tree and grass that cause direct effect to stone pagoda surrounding. Therefore, conservation treatment executed the primary dry cleaning and secondary wet cleaning treatment. Stone surface is partly not removed well such as lichens which part removed using cleansing device that use high temperature steam. Some treated part concrete and epoxy resin remove and retreatment with mixing talc and alkali granite powder to epoxy resin. Did color matching at mixing process of epoxy resin and fillers to properties with set the feel of a material. Also, drainage ditched to minimize inflow of rainwater fall from slope that is on the east of stone pagoda, tree and grass in stone pagoda surrounding wished to do remove and control occurrence of lichens hereafter minimizing moisture conteats.

  • PDF

A Study of Standardization of Detecting Abnormal Data by Front Weed's Shadow Effect in over 100 kW Photo Voltaic Power Generation Unit (100 kW 이상의 태양광 발전단위에서 전방 잡초 그림자 영향 분석에 의한 비정상 데이터 표준화 연구)

  • Kim, Hong Myeong;Lee, Yu Ri;Jung, Jae hak
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.416-423
    • /
    • 2020
  • Majority of over 100 kW capacity photo voltaic (PV) power generation system was constructed on the plate ground of soil. Rarely PV system installed on concrete or building but it usually be under 25 kW capacity. On the soil ground the weeds growen up and it's shadow influenced to decrease of amount of PV power generation. This work analysis the weeds shadow's effect to decrease of PV power generation with 100 kW capacity of real PV power generation system in Yeungnam University, Finally the weed shadow"s influence value through the real field monitoring Data is suggested for give a standard management time of weeds to avoid the negative influence on whole power plant. Moreover the hot spot which is generated by long term partial shallow on PV module also can detected with the result of this work. It also suggested as a standard value of monitoring Data.