• Title/Summary/Keyword: 하수처리시스템

Search Result 271, Processing Time 0.029 seconds

An Evaluation of Solid Removal Efficiency in Coagulation System for Treating Combined Sewer Overflows by Return Sludge (CSOs처리를 위한 응집침전시스템에서 슬러지 반송에 의한 고형물 처리효율평가)

  • Ha, Sung-Ryong;Lee, Seung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.3
    • /
    • pp.171-178
    • /
    • 2013
  • In this study, the sludge that occurs in the initial operation of coagulation system developed for the treatment of CSOs were returned to the flocculation reactor. The purposes of this study were to analyze the Characteristics of flocs that are generated through the recycling sludge and settling characteristics of sludge, and to evaluate the possibility that high concentrations of particulate matter in the initial inflow of CSOs could be used as an weighted coagulant additive. As a result, the concentration of treated CSOs pollutants at the beginning of the CSOs influent with a large amount of particulate matter over 20 ${\mu}m$ was low, after gradually increasing the concentrations of them. The flocs generated from the sludge return were similar in size compared to flocs generated through injection of micro sands, and settling velocity in case of return sludge injection was decreased from 55.1 cm/min to 21.5 cm/min. SVI value of the sludge accumulated at the bottom of the sedimentation tank was 72, and settled sludge volume decreased rapidly due to the consolidation of sludge to the time it takes to 10 minutes. these mean that sludge used for recycling has good settling characteristic. A condition of returned sludge which is 0.1% return of 0.3% extraction was formed in the balance of settlement and extraction. In this case, This condition was to be adequate to maintain the proper concentration such as 100~200 mg/L of TS and 50~100 mg/L of VS in the flocculation reactor. The usage of the return sludge containing particulate matters of CSOs as an weighted coagulant additive was able to secure a stable treated water quality despite the change of influent water quality dynamically. Furthermore, it can be expected to reduce the alum dosage along with the sludge production.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea (우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가)

  • Um, Chul Yong;Chu, Kyoung Hoon;Yun, Zu Whan;Choi, Ik Hoon;Park, Jae Young;Lee, Han Saem;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

Analysis of Microplastic Transport in the Paldang Reservoir Using MPT-Q3D (MPT-Q3D를 이용한 팔당호 내 미세플라스틱 거동 분석)

  • Sun Mi Lee;Inhwan Park
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.475-475
    • /
    • 2023
  • 직경 5 mm 이하의 미세플라스틱은 인류 활동에 의해 생산되어 하수처리장 처리수, 우수토구, 도로 분진 등 다양한 경로를 통해 하천에 유입되고 있다. 하천에 유입된 미세플라스틱은 하천흐름을 따라 하류로 이동하여 해양환경에까지 이른다. 미세플라스틱은 수체를 따라 이동할 뿐 아니라 수생생물에 의해 섭식되기도 하여 인체 위해성이 우려되는 상황이다. 특히 서울과 경기도의 주요 상수원인 팔당호는 북한강, 남한강, 경안천이 유입되어 형성되기 때문에 미세플라스틱의 유입에 따른 이송-분산 거동 평가가 중요한 영역이다. 본 연구에서는 준3차원 입자추적기법을 이용한 미세플라스틱 거동해석 모형, MPT-Q3D를 개발하였으며 팔당호 내 미세플라스틱의 거동 특성을 분석하였다. MPT-Q3D 모형은 2차원 흐름해석모형과 연계한 입자의 준3차원 거동해석을 위해 step-by-step computation method를 적용하였으며, 전단류에 의한 입자의 수평거동과 난류확산에 및 침강속도에 의한 연직거동 두 단계 계산과정에 따라 입자의 거동을 해석했다. 전단류는 2차원 흐름해석결과로부터 유속의 연직분포식을 적용하여 생성하였으며, 생성된 전단류에 의해 각 연직층 별 유속이 계산되고 𝚫t 이후 입자의 종, 횡 방향 이동거리를 계산한다. 또한 난류확산에 의한 무작위적 거동 계산을 위해 Gaussian 분포를 따른 난수 생성을 통해 무작위적 거동을 계산했다. 각 연직층에 위치한 미세플라스틱 입자의 종, 횡 방향 거동을 계산한 후 입자의 연직거동을 계산한다. 입자의 연직 위치는 난류확산과 침강속도에 따라 계산되며 침강속도는 미세플라스틱의 밀도 및 직경에 따라 결정된다. 현장 샘플링 결과에 따라 팔당호로 유입되는 미세플라스틱은 폴리스틸렌(PS), 폴리에틸렌(PE), 폴리에스테르(Polyester)가 있으므로, 세 종류의 미세플라스틱을 동시에 주입하여 팔당호 내 거동을 분석했다. 남한강, 북한강, 경안천의 유량 차이로 인해 팔당호로 유입되는 미세플라스틱은 대체로 남한강과 북한강의 흐름특성에 영향을 받았다. 경안천의 경우 유량이 낮아 팔당호로 유입되지 못하고 좌안을 따라 하류로 이동됐다. 남한강과 북한강에서 유입된 미세플라스틱은 주로 팔당호 내 소내섬을 거쳐 팔당댐 쪽으로 이동했다. 또한 팔당댐 인근에서는 PP, PE, Polyester 순으로 많은 양이 유입되는 결과가 나타났다.

  • PDF

Introduction plan of future integrated water circulation management system using LID facility model verification (LID시설 모델검증을 활용한 미래형 통합 물순환관리시스템 도입방안)

  • Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.67-73
    • /
    • 2021
  • As the impermeable area increases due to urbanization and industrialization, the influence of non-point pollutants caused by rainfall runoff on the water system is increasing. In the past, the best management practices(BMP) were used a lot to manage non-point pollutants, but recently, technology that naturally treats them through LID (Low Impact Development) technology is widely used. In this study, various rainfall events were simulated through the SWMM model based on the data of rainfall monitoring in bioretention among natural facilities. The characteristic of LID modeling research is that it is difficult to build accurate modeling data with short-term data because real data is the result obtained through natural facilities, and it is difficult to implement an accurate model. In this study, the data monitored for 3 years It is significant in that it has built a precise model. The actual data monitored a total of 18 times was simulated, and the inflow and outflow and the removal efficiency of five pollutants were simulated. As a result of performing the performance evaluation, most of the 7 items showed excellent indicators, and the TN and TP showed relatively low simulation performance. In the future, it is expected that Korea will introduce an integrated water management system in which the water supply system and the sewage system are substantially integrated and operated. Therefore, the results of this study are considered to play an important role in the initial stage of rainfall management in the future integrated water management system, and the extent of rainfall runoff reduction and pollutant reduction in the expected installation area can be predicted in advance. This is expected to prevent overdesign of bioretention.

The Removal of Organics and Nutrients in an Anoxic/Oxic Process Using Surface-modified Media (표면개질 담체를 이용만 무산소/호기 공정에서의 유기물 및 영양염류 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2008
  • Surface of hydrophobic media was modified to become hydrophilic by ion beam irradiation. Fixed bed biofilm reactors packed with or without surface modification were used to remove organics, nitrogen, and phosphorus from sewage. This system composed of anoxic/oxic cycles to increase the nutrient removal. A cylindrical polyethylene was used as a packing media in this study. With 12 hours of hydraulic retention time (HRT), the reactors with and without surface modification showed 95% and 92% $COD_{cr}$ removal, respectively. Both reactors showed over 95% $COD_{cr}$ removals for a longer HRT of 16 hours. Nitrogen removal ranged 54.8% to 70.2% for the surface modified system and 57.5% to 76.5% for the non-modified system under same condition. Finally, phosphorus removal ranged 59.4% to 69.8% for the surface modified system and 51.3% to 63.4% for the non-modified system under same condition. From this study organics and phosphorus were better removed in using surface modified media and vice versa for nitrogen removal.

A Study on Efficiency of Water Purification of Korean Village Bangjuk[dike] as a Means of Ecological Watershed Management (생태적 유역관리 도구로써 마을방죽의 수질정화 효율성 고찰)

  • An, Byung-Chul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.90-100
    • /
    • 2012
  • This study centering on 10 village - Bangjuks analyzed multifunctionality value of village Bangjuks which have been main water treatment system in Korean traditional villages. On the basis of understanding the structure and character of components such as the well, common spring, village waterway and others which making water-flow and consisting of aquatic system in Korean traditional village Bangjuk, the conclusion as the instrumental device of social and ecological role and ecological watershed management, securing the ecosystem soundness of the damaged or deteriated aquatic ecosystem due to the industrialization and urbanization is as below; 1. The traditional village Bangjuk was environmentally friendly hydraulic system which gathers waterways of village into a point including sewage water, retains and flows out to village through agricultural waterway. Through this Bangjuk, they have managed sewage and rainfall runoff flowed out village efficiently. It is not only a detention system of water but a kind of eco-friendly system that flow out water into the rivers after reusing and filtering it. 2. Around five traditional villages and five villages after modernization, this study classified the types of village Bangjuk as three types considering geographic location, size, etc; marsh type of low swamp, high water -low rice field type of natural flow stucture, low water - high rice field type requiring artificial irrigation facility. All the five traditional villages were turned out to be marsh type of low swamp. Geoji, Sanjeri, Ma-am, Yangchon of the agricultural villages were high water-low rice filed type, and Sangchoenri village was classified low water-high rice field type. 3. This study checked up the function of water purification of village Bangjuk. In Wonteo and Geji villages affected by discharge of village sewer and domestic sewage, the efficiency of ammonia nitrogen($NH_3-N$) and total phosphorus(T-P) was 56~95%, which was high. In Sangcheonri and Sanjeri villages strongly affected by stall and farmland, the efficiency of suspended solids(SS) was 70~85%, and that of total nitrogen(T-N) and total phosphorus(T-P) was 5.3~65%. 4. A water purification system can be found out in the system of village Bangjuk that filter out village sewage and rainfall runoff flowed through the settle and filter of pollution source and denitrification of plants. Through this system of village Bangjuk, it must be used as the basic facilities for the ecological watershed management. The sewage management system of village Bangjuk as a eco-filter must be used and studied as an eco-friendly facility for the ecological watershed management around the subwatershed and catchment.

Comparison of Anoxic/Oxic Membrane Bioreactor - Reverse Osmosis and Activated Sludge Process-Microfiltration-Reverse Osmosis Process for Advanced Treatment of Wastewater (폐수의 고도처리를 위한 무산소/호기형 분리막생물반응조 - 역삼투 공정과 활성슬러지공정 - 정밀여과 - 역삼투 공정의 비교)

  • Roh, Sung-Hee;Kim, Sun-Il;Quan, Hong-hua;Song, Yon-Ho
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.521-526
    • /
    • 2006
  • A membrane bioreactor (MBR) is an effective tool for wastewater treatment with recycling. MBR process has several advantages over conventional activated sludge process (ASP); reliability, compactness, and quality of treated water. The resulting high-quality and disinfected effluents suggest that MBR process can be suitable for the reused and recycling of wastewater. An anoxic/oxic (A/O) type MBR was applied to simultaneous removal of organics and nutrients in sewage. At first, the efficiency of submerged MBR process was investigated using a hollow fiber microfiltration membrane with a constant flux of $10.2L/m^2{\cdot}h$ at each solids retention time (SRT). Results showed that protein/carbohydrate (P/C) ratio increased and total extracellular polymeric substances (EPS) remained constant with SRT increased. Secondly, A/O type MBR with a reverse osmosis (RO) membrane was employed to treat the municipal wastewater. The performance of A/O type MBR-RO process is better for the treatment of organics and nutrients than ASP-MF-RO process in terms of consistent effluents quality.

Target candidate fish species selection method based on ecological survey for hazardous chemical substance analysis (유해화학물질 분석을 위한 생태조사 기반의 타깃 후보어종 선정법)

  • Ji Yoon Kim;Sang-Hyeon Jin;Min Jae Cho;Hyeji Choi;Kwang-Guk An
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.2
    • /
    • pp.109-125
    • /
    • 2023
  • This study was conducted to select target fish species as baseline research for accumulation analysis of major hazardous chemicals entering the aquatic ecosystem in Korea and to analyze the impact on fish community. The test bed was selected from a sewage treatment plant, which could directly confirm the impact of the inflow of harmful chemicals, and the Geum River estuary where harmful chemicals introduced into the water system were concentrated. A multivariable metric model was developed to select target candidate fish species for hazardous chemical analysis. Details consisted of seven metrics: (1) commercially useful metric, (2) top-carnivorous species metric, (3) pollution fish indicator metric, (4) tolerance fish metric, (5) common abundant metric, (6) sampling availability (collectability) metric, and (7) widely distributed fish metric. Based on seven metric models for candidate fish species, eight species were selected as target candidates. The co-occurring dominant fish with target candidates was tolerant (50%), indicating that the highest abundance of tolerant species could be used as a water pollution indicator. A multi-metric fish-based model analysis for aquatic ecosystem health evaluation showed that the ecosystem health was diagnosed as "bad conditions". Physicochemical water quality variables also influenced fish feeding and tolerance guild in the testbed. Eight water quality parameters appeared high at the T1 site, indicating a large impact of discharging water from the sewage treatment plant. T2 site showed massive algal bloom, with chlorophyll concentration about 15 times higher compared to the reference site.

Mixing Zone Analysis on Outfall Plume considering Influence of Temperature Variation (수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석)

  • Kim Ji-Yeon;Lee Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.947-953
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on 'how to dispose the treated municipal water and wastewater in harbor' brings peoples' concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water, CORMIX( Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.