• Title/Summary/Keyword: 하수처리방류수

Search Result 185, Processing Time 0.023 seconds

Evaluation of Environmental and Economic Impacts of Advanced Wastewater Treatment Plants with Life Cycle Assessment (고도 하수처리장의 전과정평가에 따른 환경성 및 경제성 평가)

  • Pyo, SeHee;Kim, MinJeong;Lee, SeungChul;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.503-515
    • /
    • 2014
  • A lot of existing wastewater treatment plants (WWTPs) are rebuilt or retrofitted for advanced wastewater treatment processes to cope with reinforced effluent criteria of nitrogen and phosphorous. Moreover, how to treat the wasted sludge from WWTPs has been also issued since the discharge of the wasted sludge into ocean is impossible from 2011 due to the London Convention 97 protocol. These trend changes of WWTPs get a motivation to assess environmental and economic impacts from the construction stage to the waste stage in WWTPs. Therefore, this study focuses on evaluation of environmental and economic impacts of the advanced wastewater treatment processes and waste sludge treatment process by using life cycle assessment. Four advanced wastewater treatment processes of Anaerobic/Anoxic/Oxic ($A_2O$), 5 stages-Bamard Denitrification Phosphate (Bardenpho), Virginia Initiative Plant (VIP), and Modified University of Cape Town (MUCT) are chosen to compare the conventional activated sludge (CAS) and three waste sludge treatment methods of land fill, incineration, and composting are used. To evaluate environmental and economic impacts of each advanced wastewater treatment processes, life cycle assessment (LCA) and life cycle cost (LCC) are conducted based on International organization for standardization (ISO) guidelines. The results clearly represent that the $A_2O$ process with composting shows 52% reduction in the environmental impact than the CAS process with landfill. On the other hand, the MUCT process with composting is able to save 62% of the life cycle cost comparing with the CAS process with landfill. This result suggested the qualitative and quantitative criteria for evaluating eco-environmental and economic technologies of advanced treatment processes and also sludge treatment method, where their main influence factors on environmental and economic impacts are analyzed, respectively. The proposed method could be useful for selecting the most efficient and eco-friendly wastewater treatment process and sludge treatment method when retrofitting the existing WWTPs to advanced treatments.

Sewage Treatment Using a Double Media Reed Constructed Wetland (복층여재 갈대 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.379-388
    • /
    • 2014
  • A sewage was treated using a serially combined vertical(VFCW) and horizontal flow double media (sand and zeolite for VFCW and sand and waste oyster-shell for HFCW) reed constructed wetland(HFCW) with intermittent feeding (see Fig. 1). The sewage was fed into the reed constructed wetland for 10 minutes every 6 hours at the hydraulic load of $314L/m^2{\cdot}day$. The summarized results were as follows: pH values in the effluent depended very heavily on oyster-shell height filled in the HFCW. They were maintained at less than pH 6.24 when the height of the oyster-shell layer was 200 mm. Influent DO(oxygen demand) values(average 0.19 mg/L) were increased in the VFCW(average 7.65 mg/L) and decreased again in the HFCW(average 6.49 mg/L). They were higher in the winter than in the summer. The OTR(oxygen transfer rate) was $57.15g\;O_2/m^2{\cdot}day$ in the VFCW and $5.65g\;O_2/m^2{\cdot}day$ in the HFCW. The removal efficiency of $NH_4{^+}$-N was 80.17%(6.01 $NH_4{^+}$-N mg/L in the effluent). It was lower than that in the case where only zeolite was filled in the reed constructed wetland. But it was expected that treated sewage effluent using a double media reed constructed wetland with 300 mm zeolite layer could stably meet the Korean treated sewage effluent standard(20 mg T-N/L). Average removal efficiencies were SS 88.09%, BOD 88.12%, $COD_{Cr}$ 83.11%, $COD_{Mn}$ 85.58%, T-N 57.21%, $NH_4{^+}$-N 80.17%, T-P 86.73%. Nearly, The concentration of $NO_3{^-}$-N in the effluent of the VFCW was decreased in that of the HFCW. More than half of T-N in the effluent was $NO_3{^-}$-N(7.92 mg/L) but the concentration of $NO_2{^-}$-N in the effluent was average 0.90 mg/L. The removal efficiencies of T-P were 93.24%, 86.30% and 55.44% at the height of the oyster-shell-filled constructed wetland of 800 mm, 500 mm and 200 mm, respectively and therefore, they were proportional to oyster-shell height filled in the HFCW.

Calibration and Validation of SWAP Model to Estimate the Soil Salinity of Reclaimed Wastewater Irrigation on Paddy Fields (농업용수 재이용에 따른 토양염분 추정를 위한 SWAP 모형의 보정과 검정)

  • Jang, Tae-Il;Sung, Chung-Hyun;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.608-612
    • /
    • 2009
  • 본 연구에서는 하수재이용에 따른 토양에서의 염분변화를 추정하기 위하여 SWAP(Soil-Water-Atmosphere-Plant) 모형을 선정하여 경기도 화성시 수원환경사업소 인근에 위치한 병점지구를 대상으로 모형의 적용성을 분석하였다. 실험에 사용한 관개용수는 1) 지하수(TR#1), 2) 하수처리장 방류수+여과+UV (TR#3)로 분류하여 실험에 사용하였다. 영농기간 동안 논으로 유입되는 총 유입수는 $1,724.2^{\sim}1,733.7$ mm 범위였으며, 이 중 약 64%가 강우에 의해 공급되었고, 나머지는 관개에 의하여 유입되었다. 유입관개수의 EC는 지하수 관개수인 TR#1이 다른 처리구에 비해 작았고, TR#3의 경우 $0.442{\sim}0.698$ dS/cm의 범위를 보였다. 모형의 보정과 검정을 위해서 대상지구에 FDR(Frequency Domain Reflection)을 설치하여 토양수분함유량과 염분농도를 토심에 따라 일단위로 모니터링 하였다. 토양함수량의 보정기간 중 토심별(50, 100, 140 cm) RMSE는 TR#1에서 $0.001^{\sim}0.002$ $cm^3cm^{-3}$, TR#3에서 $0.002^{\sim}0.006$ $cm^3cm^{-3}$으로 나타났으며, 검정기간 중 토심별 RMSE는 TR#1에서 $0.003^{\sim}0.064$ $cm^3cm^{-3}$, TR#3에서 0.001$cm^3cm^{-3}$로 나타났다. 토양염분의 보정기간 중 토심별 RMSE는 TR#1에서 $0.001^{\sim}0.023{\times}10^{-3}$ dS $m^{-1}$, TR#3에서 $0.028^{\sim}0.045{\times}10^{-3}$ dS$m^{-1}$로 나타났으며, 검정기간의 토심별 RMSE는 TR#1에서 $0.018^{\sim}0.037{\times}10^{-3}$ dS$m^{-1}$, TR#3에서 $0.004^{\sim}0.014{\times}10^{-3}$ dS$m^{-1}$로 적용성이 있는 것으로 나타났다.

  • PDF

Nitritation at Various Temperature Conditions - Using Anaerobic Digester Supernatant (다양한 온도 조건에서 아질산화 반응 유도 - 혐기 소화 상징액을 대상으로)

  • Gil, Kyung-Ik;Im, Ji-Yeol
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.237-243
    • /
    • 2011
  • As the effluent quality standard of the municipal wastewater treatment plant (MWTP) has been strengthened, the treatment of the recycle water containing high concentration of ammonium nitrogen has been considered as one of retrofit methods for upgrading the exising MWTPs. In this study, nitritation, economic nitrogen removal process, was induced by laboratory-scale reactor at the $35^{\circ}C$, $20^{\circ}C$, and $10^{\circ}C$ temperature conditions using anaerobic digester supernatant. The stable nitritation was achieved over $20^{\circ}C$, but nitrification was induced at $10^{\circ}C$. It means that the nitritation was affected by SRT and temperature. SRT, demanded for nitritation, is changed according to the temperature. Therefore, it is considered that SRT and temperature are important factors in nitritation. Also, it is approved that inducing the ammonium nitrogen removal and the nitritation are more beneficial over $20^{\circ}C$. The conclusion of this study can be used for the important basic reference when nitritation process is applied for MWTPs.

Advanced Oxidation Processes of Secondary Effluent for Reuse (재사용을 위한 하수처리장 방류수의 고급산화처리)

  • 조일형;송경석;성기석;정문호;이홍근;조경덕
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2000
  • The use of photo-catalytic processes in pollution abatement and resource has a significant economic importance. Therefore, the applications of photochemical oxidation of secondary effluent driven by UV, TiO2, TiO2/UV, H2O2/UV and TiO2/H2O2/UV, have been investigated in order to treat the secondary effluent from municipal sewage. Various experimental parameters such as BOD, CODcr, Nurbidity, total P, and SPC were examined in each photo-catalytic reaction system. The results showed that the application of single oxidant such as UV, TiO2 only has a minor effect on parameters reduction (CODcr, BOD, etc) to treat the secondary effluent, whereas the combinations of oxidants increase the removal efficiency. The best removal efficiency in every parameters was achieved by the combination of TiO2, H2O2 and UV. It was also found that the optimum amount of TiO2 for the treatment was 1g/ι to achieve water reuse standard. From the results, the photocatalytic reaction system can be an alternative as a post-treatment to treat the secondary effluent from municipal sewage.

  • PDF

A Study on the Treatment of Secondary Effluent by ${\gamma}-ray$ Irradiation ($\gamma$-선의 조사를 이용한 하수처리장 방류수 처리에 관한 연구)

  • 이면주;정영도;박순달
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 1998
  • This study was carried out for the purpose of industrial reuse of effluent released from activated sludge unit by $\gamma $-ray irradiation technique. The dissolved organic carbon in the effluent of an activated sludge unit is mostly refractory or inert material which are difficult to be degraded by micro organism. The effluent generated from activated sludge unit was irradiated with Co$^{60}$ $\gamma $-ray under condition of air bubbling. The effects of irradiation on the pH, COD, TOC, color, molecular weight distribution were investigated by membrane filtration and u.v.-spectrum analysis. With increasing dose, the TOC was decreased smoothly. The COD was increased at lower dose, while the COD was decreased at higher dose. The TOC and COD, however, were decreased smoothly when TiO$_{2}$ was added to the solution. It was thought that the differential decreasing trend of COD and TOC in according to the absence or presence of TiO$_{2}$ was due to the molecular weight distribution shifted from group of higher molecular weight to group of lower one which are more easy to be decomposed. The removal efficiency of color was 71.5% and it was increased to 85.7% when TiO$_{2}$ was added to the solution. The $\gamma $-ray irradiation was effective on the production of chlorine.

  • PDF

Hydrochemical and Isotopic Characteristics of Major Streams in the Daejeon Area (대전지역 도심하천의 수리화학적 및 동위원소적 특성)

  • Jeong, Chan-Ho;Moon, Byung-Jin
    • Economic and Environmental Geology
    • /
    • v.42 no.4
    • /
    • pp.315-333
    • /
    • 2009
  • In this study, the hydrochemical and the isotopic characteristics of major streams in the Daejeon area were investigated during rainy and dry seasons. The stream water shows the electrical conductivity of the range of $37{\sim}527{\mu}s$/cm, and pH $6.21{\sim}9.83$. The chemical composition of stream waters can be grouped as three types: the upper streams of Ca(Mg)-$HCO_3$ type, Ca(Mg)-$SO_4(Cl)$ type of middle streams flowing through urban area, and Na(Ca)-$HCO_3$(Cl, $SO_4$) type of the down streams. Based on in-situ investigation, the high pH of stream waters flowing through urban area is likely to be caused by the inflow of a synthetic detergent discharging from the apartment complex. The electrical conductivity of stream waters at a dry season is higher than those of at a rainy season. We suggest that the hydro-chemical composition of stream waters in the Daejeon area was affected by the discharging water from the sewage treatment facilities and anthropogenic contaminants as well as the interaction with soil and rocks. ${\delta}D$ and ${\delta}^{18}O$ values of the stream waters show the relationship of ${\delta}D=6.45{\delta}^{18}O-7.4$, which is plotted at a lower area than global meteoric water line(GMWL) of Craig(1961). It is likely that this isotopic range results from the evaporation effect of stram waters and the change of an air mass. The isotope value shows an increasing trend from upper stream to lower stream, that reflects the isotopic altitude effect. The relationship between ${\delta}^{13}C$ and $EpCO_2$ indicates that the carbon as bicarbonate in stream water is mainly originated from $CO_2$ in the air and organic materials. The increasing trend of ${\delta}^{13}C$ value from upper stream waters to lower stream waters can be attributed to the following reasons: (1) an increasing dissolution of $CO_2$ gas from a contaminated air in downtown area of the Daejeon, and (2) the increment of an inorganic carbon of groundwater inflowed into stream by base flow. Based on the relationship between ${\delta}^{34}S$ and $SO_4$ of stream waters, the stream waters can be divided into four groups. $SO_4$ content increases as a following order: upper and middle Gab stream${\delta}^{34}S$ value decreases as above order. ${\delta}^{34}S$ value indicates that sulfur of stream waters is mainly originated from atmosphere, and is additionally supplied by pyrite source according to the increase of sulfate content. The sulfur isotope analysis of a synthetic detergent and sewage water as a potential source of the sulfur in stream waters is furtherly needed.

Performance Enhancement Study of a Final Clarifier by the Optimum Design of Inlet and Baffle Condition (유입구 및 정류벽 최적설계에 의한 최종 침전지 성능 개선 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Jung, Sung-Hee;Gang, Dong-Hyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The effluent quality is directly affected by the separation of biological solids in a final clarifier because the majority of discharged $BOD_5$ and SS are virtually dependent on the results of biological solids in the sedimentation tank effluent. If a final clarifier is effectively designed and operated, the desired goal of clarification for wastewater can be achieved together with the cost reduction in the treatment of wastewater. To this end flow characteristics and the removal efficiency of SS are numerically investigated especially by the change of the inlet position and the installation of baffle to improve the performance of a rectangular final clarifier. The 2-D computer program developed in a rectangular coordinates has been successfully validated against experimental residence time distribution(RTD) curves obtained by tracing radio-isotope. The lowering of the inlet position weakens the density current and induces the settling of SS in the front zone of a clarifier. Thus the decreased traveling distance of the sludge increases the removal efficiency of SS in the effluent. The inlet baffle installed in the front region of clarifier prevents the short circuiting flow and induces to flow into the dense underflow, which eventually improves the effluent quality. In the case of lower inlet position, however, installation of baffle results in degradation of effluent quality. Consequently it is strongly recommended that in-depth numerical study be performed in advance for optimizing a clarifier design and retrofitting to improve effluent quality in a final clarifier.

Constructed Wetlands in Treating Domestic and Industrial Wastewater in India: A Review (인도의 가정 및 산업 폐수 처리를 위한 인공습지: 총론)

  • Farheen, K.S.;Reyes, N.J.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.23 no.3
    • /
    • pp.242-251
    • /
    • 2021
  • Surface water pollution is a serious environmental problem in developing countries, like India, due to the unregulated discharge of untreated wastewater. To overcome this, the constructed wetlands (CWs) have been proven to be an efficient technology for wastewater treatment. In this study, different existing and experimental facilities were reviewed to be able to determine the current status of constructed wetlands in India. Based on the collected data from published literature, industrial wastewater contained the highest average chemical oxygen demand (COD), biochemical oxygen demand (BOD). In terms of total nitrogen (TN), Total phosphorous (TP), the lowest concentration was found on domestic wastewater. Vertical flow constructed wetlands (VFCW) and Horizontal flow constructed wetland (HFCW) were more effective in removing TSS, BOD, TP in domestic and industrial wastewater, whereas hybrid constructed wetlands (HCW) showed the highest removal for COD. The use of constructed wetlands as advanced wastewater treatment facilities in India yielded better water quality. The treatment of wastewater using constructed wetlands also enabled further reuse of wastewater for irrigation and other agricultural purposes. Overall, this study can be beneficial in evaluating and promoting the use of constructed wetlands in India.

Explanation of Foaming Mechanism and Experimental Application of Foam Reduction Techniques in the Treated Wastewater Outlet of Wastewater Treatment Plant Connected to a Tidal River, Korea (감조하천에 연결된 하수처리장 방류구의 거품 형성기작 해석 및 거품발생 저감기술의 실험적 현장적용)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.187-196
    • /
    • 2016
  • This study was performed to improve the foaming generated in the effluent of wastewater treatment plant from March 2015 to July 2016. The main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. Particularly, the foam growth was most active when there is low tide and larger discharge. To solve this problem, we experimented after installing fine mesh screen and the artificial channel device with underwater discharging outlet in the treated wastewater discharge channel and the outlet, respectively. As a result, the effects of foam reduction by devices ranged 85.0~92.0% and 70.7~85.6%, respectively. In addition, the foam and the noise were easily solved, first of all look to contribute to the prevention of complaints. Our device studies were applied to a single wastewater treatment plant. However, it is considered to be able to apply in other similar cases of domestic sewage treatment plants.