Characteristics of Membrane Fouling in the Membrane-Coupled Activated Sludge (MCAS) System (막격합형 활성슬러지 시스템에서 막오염 특성의 분석)

  • 김재석;이정학
    • Membrane Journal
    • /
    • v.8 no.3
    • /
    • pp.130-137
    • /
    • 1998
  • Membrane fouling characteristics in the membrane-coupled activated sludge system were investigated. The influence of the floc size variation on the filtration resistance was analyzed using resistance-in-series model and mixed liquor was fractionated into three components to verify which component would give rise to a major contribution to the total resistance. The microbial floc size was rapidly reduced during the initial 4~6 hours of operation, and then decreased slightly but steadily, followed by leveling off at the size of 20 $\mu$m. The specific resistance of activated sludge increased with operation time, and measured values of specific resistance were matched well with the values estimated on the basis of the mean particle size in the mixed liquor. The contribution of soluble organics and cells to the total resistance was relativdy small compared with that of the supematant. Colloidal particles in the supematant showed much higher specific resistance than that of microbial floc, and played the most important role in the cake resistance.

  • PDF

Process variations in SBR and BS-SBR treatment (SBR 및 BS-SBR 처리의 공정변화 연구)

  • 양형재;정윤철;신응배
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.1
    • /
    • pp.59-68
    • /
    • 1997
  • The main purpose of this study was to determine effects of BS-SBR compared with SBR on the removal of soluble organics and sludge separation. In the BS-SBR process, soluble organics were removed by suspended activated sludge as well as biological fixed films and these two processes occurred simultaneously in one tank. The removal efficiency of soluble COD in the BS-SBR, approximately 97% in both 1 and 3-cycle/d was higher than for SBR. The BS-SBR process was very efficient for SS removal. The averaged SS concentration were 4.8 mg/l over the operation period, the daily SS values were consistently below 10 mg/l in both of 1-cycle and 3-cycle a day. The sludge settling characteristics in BS-SBR were totally different from SBR's. The sludge, dark brown, was well flocculated and its floc size was visible larger than the SBR's.

  • PDF

Complete genome sequence of Comamonas sp. NLF-7-7 isolated from biofilter of wastewater treatment plant (폐수처리장의 바이오 필터로부터 분리된 Comamonas sp. NLF-7-7 균주의 유전체 염기서열 해독)

  • Kim, Dong-Hyun;Han, Kook-Il;Kwon, Hae Jun;Kim, Mi Gyeong;Kim, Young Guk;Choi, Doo Ho;Lee, Keun Chul;Suh, Min Kuk;Kim, Han Sol;Lee, Jung-Sook;Kim, Jong-Guk
    • Korean Journal of Microbiology
    • /
    • v.55 no.3
    • /
    • pp.309-312
    • /
    • 2019
  • Comamonas sp. NLF-7-7 was isolated from biofilter of wastewater treatment plant. The whole-genome sequence of Comamonas sp. NLF-7-7 was analyzed using the PacBio RS II and Illumina HiSeqXten platform. The genome comprises a 3,333,437 bp chromosome with a G + C content of 68.04%, 3,197 total genes, 9 rRNA genes, and 49 tRNA genes. This genome contained pollutants degradation and floc forming genes such as sulfur oxidization pathway (SoxY, SoxZ, SoxA, and SoxB) and floc forming pathway (EpsG, EpsE, EpsF, EpsG, EpsL, and glycosyltransferase), respectively. The Comamonas sp. NLF-7-7 can be used to the purification of wastewater.

Effect of Fouling Reducing Additives on Membrane Filtration Resistance of Activated Sludge (막오염 감소제가 활성슬러지의 여과저항에 미치는 영향)

  • Chung, Tai Hak;Lee, Jong Hoon;Kim, Hyoung Gun;Bae, Young Kyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.406-413
    • /
    • 2012
  • Effect of three additives, chitosan, ferric chloride, and MPE50 on membrane fouling reduction was studied. They were introduced with various dosing rate into activated sludge, and changes in filtration resistance measured by the batch cell filtration test were evaluated. Both the filtration resistance and the specific cake resistance were minimized at 20 mg/g-MLSS with chitosan, 70 mg/g-MLSS with ferric chloride, and 20 mg/g-MLSS with MPE50 addition, respectively. Introduction of the additives into the activated sludge resulted in reduction of not only cake resistance, but also fouling resistance. However, the chitosan addition to three different activated sludge resulted in three different optimal dose of 10, 20, 30 mg/g-MLSS, respectively. This implies that the optimal dose is dependent on sludge characteristics rather than a constant value. Overdose above the optimal dosage always aggravated filterability in all cases. Zeta potential of sludge flocs, relative hydrophobicity, floc size distribution, soluble EPS concentration and supernatant turbidity were measured in order to analyze fouling reduction mechanism. Nearly neutral surface charge along with the largest particle size was observed at the optimal dose. This could be explained by particle destabilization and restabilization mechanism as positively charged additives were injected into sludge flocs of negative surface charge. Both soluble EPS concentration and supernatant turbidity also showed the lowest value at the optimal dose. These foulants are believed to be coagulated and entrapped in sludge flocs during flocculation. Chitosan and MPE50 which are cationic polymeric substances showed higher reduction in both soluble EPS and fine particles comparing with ferric chloride.

An Evaluation of Solid Removal Efficiency in Coagulation System for Treating Combined Sewer Overflows by Return Sludge (CSOs처리를 위한 응집침전시스템에서 슬러지 반송에 의한 고형물 처리효율평가)

  • Ha, Sung-Ryong;Lee, Seung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.3
    • /
    • pp.171-178
    • /
    • 2013
  • In this study, the sludge that occurs in the initial operation of coagulation system developed for the treatment of CSOs were returned to the flocculation reactor. The purposes of this study were to analyze the Characteristics of flocs that are generated through the recycling sludge and settling characteristics of sludge, and to evaluate the possibility that high concentrations of particulate matter in the initial inflow of CSOs could be used as an weighted coagulant additive. As a result, the concentration of treated CSOs pollutants at the beginning of the CSOs influent with a large amount of particulate matter over 20 ${\mu}m$ was low, after gradually increasing the concentrations of them. The flocs generated from the sludge return were similar in size compared to flocs generated through injection of micro sands, and settling velocity in case of return sludge injection was decreased from 55.1 cm/min to 21.5 cm/min. SVI value of the sludge accumulated at the bottom of the sedimentation tank was 72, and settled sludge volume decreased rapidly due to the consolidation of sludge to the time it takes to 10 minutes. these mean that sludge used for recycling has good settling characteristic. A condition of returned sludge which is 0.1% return of 0.3% extraction was formed in the balance of settlement and extraction. In this case, This condition was to be adequate to maintain the proper concentration such as 100~200 mg/L of TS and 50~100 mg/L of VS in the flocculation reactor. The usage of the return sludge containing particulate matters of CSOs as an weighted coagulant additive was able to secure a stable treated water quality despite the change of influent water quality dynamically. Furthermore, it can be expected to reduce the alum dosage along with the sludge production.

Utilization of Image Analysis Technique for Characterization of Micro-Bubbles Generated by Polymeric Membrane Module (고분자 중공사막 모듈을 이용한 미세기포 발생과 이미지 분석기법을 이용한 기포 특성 파악)

  • Kim, Jun-Young;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.447-452
    • /
    • 2011
  • In this study, the polymeric membrane module is used as a diffuser and an image analysis technique based on visual information is applied to get bubble characteristics. The bubble size generated passed through polymeric membrane module was smaller from 30 to 64% than that of air stone, and bubble volume over 70% was ranged from 0.2 to 0.82 mm. But over 80% the bubbles from air stone diffuser ranged from 0.77 to 1.08 mm. The air stone and polymeric membrane module used as diffuser for a flotation system. The floc size inside the flotation reactor using air stone diffuser was bigger than that of the polymeric membrane module, which means that the micro-bubbles generated from polymeric membrane module could provide better opportunities for collisions between colloidal particles than those from air stone diffuser. Therefore, there is a possibility to apply the polymeric membrane module as a diffuser to increase the removal efficiency in the flotation process. Also, the image analysis technique used in this study could be applied as a useful analytical tool for acquisition of an information about the bubble characteristic.

Application of electro-coagulation for the pretreatment of membrane separation of anaerobic digestion effluents (혐기성 소화액의 막분리를 위한 전기응집 전처리 연구)

  • Kim, Shin-Young;Chang, In-Soung;Kim, Jang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4665-4674
    • /
    • 2014
  • The aim of this study was to confirm the feasibility of the electro-coagulation process as a pre-treatment for the membrane separation of anaerobic digestion effluents to minimize membrane fouling. The reduction of membrane fouling was evaluated according to the number of electrodes (immersed surface area of electrodes), current density and contact time. In the case of the small surface area of electrodes, the increased electric field strength resulted in a soluble COD increase due to the destruction of the microbial flocs and/or cells, whereas large changes in the soluble COD were not observed in the case of the high surface area of electrodes. On the other hand, the T-P concentration decreased as a result of the precipitation of aluminum ions and phosphates. The membrane permeation flux increased and the fouling resistance (Rc+Rf) decreased with increasing electric current density. Although the particle size of the anaerobic digestion effluent increased slightly, it was not related directly to the reduced fouling phenomena. The main mechanism for the enhanced flux was attributed to the inorganic particulate produced during electrocoagulation, such as $AlPO_4$, which acted as a dynamic membrane deposited on the membrane surface.

Plasma Aided Flotation for Removing Organic Substances and Killing Microorganisms

  • Yu, Seung-Min;Hong, Eun-Jeong;Yu, Seung-Yeol;Park, Jun-Seok;No, Tae-Hyeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.122-122
    • /
    • 2014
  • 수중방전을 환경분야에 적용하기 위한 플라즈마 부상법이 개발되었다. 플라즈마 부상법은 물 속에서 발생시킨 플라즈마가 가지고 있는 주요특성 중 물리적 특징인 쇼크웨이브, UV조사, 버블생성 등과 화학적 특징인 OH라디칼 및 염소산화물 생성 등을 이용하여 물 속에 존재하는 용존성 및 입자성 물질을 부상분리 기법으로 제거하는 공법이다. 유기물을 제거하는 기작으로는 침전, 여과, 분해 등이 있고, 이를 구현하기 위한 공정으로 중력침강법, 부상분리법, 멤브레인법, 미생물법 등이 있다. 이 중에서 가압공기부상법은 침강법에 비해 부지면적을 적게 소모하고 처리시간이 50% 이상 감소되는 특징이 있다. 가압공기부상법은 물 속에 공기를 과포화시킨 후 노즐을 통해 재분사할 때 발생하는 압력차에 의해 미세기포가 발생함을 이용하여 유기물을 분리하는 공법이다. 그러나, 가압용 장비 및 반송수가 필요하고, 미생물분리는 불가능한 단점이 있다. 이에 본 연구에서는 미생물살균과 유기물 분리가 동시에 일어나는 플라즈마를 이용한 부상분리기법을 개발하였다. 본 연구에서는 난분해성 용존유기물인 휴믹산 100 mg/L의 플라즈마 공기부상법에 의한 제거능을 확인하였다. 용존성 휴믹산을 입자성 물질로 전환하여 플록을 형성시키고자 알루미늄설페이트(Al2(SO4) $3{\cdot}18H2O$)를 100 mg/L 주입하였고, 침출수와 같이 염도가 높은 물을 모사하고자 35 g/L의 염화나트륨을 첨가한 상태에서 방전을 실시하였다. 방전에 사용된 전원은 EESYS사에서 제작한 펄스형 고전압 전원장치를 사용하였고 최대 15 kW의 출력 중 6 kW의 전력을 인가하였다. 전극 한 개는 2 mm 텅스텐봉을 세라믹튜브로 감싼 구조로 총 사용전극은 28개이다. 전극 한 개당 대략 200 Watt의 전력이 소모되며 이 때 최대의 버블이 생성됨을 확인하였다. 전극 1개에서 생성되는 버블의 부피는 14 mL/min 로 측정되었다. 버블의 크기는 평균 70 um이고 가압공기부상법에서 최적공기크기로 제시하고 있는 40~80 um 의 버블은 약 80% 가량 생성된다. 본 연구에서 사용된 반응시스템에서의 물의 높이는 약 500 mm 이고 전체 40 L의 수조가 3개의 벽으로 분리되어 4개의 수조로 분리되었다. 각 수조는 하부에 7개의 전극을 포함하고 있다. 플라즈마 발생시 생성되는 기포는 약 1분 방전 후에 포화농도에 도달하며 방전종료 후 약 4분간 수체 내에 남아있게 된다. 이를 공정에 적용하여 1분 방전 및 4분 휴지의 순서로 플라즈마를 인가하였다. 휴믹산 용액의 유량을 2 lpm 으로 운전하였을 때 최종 처리율은 94% 이고 이때의 대장균 살균능은 99%이다.

  • PDF

Study on solubilization of sewage sludge using electrolysis techniques (전기분해에 의한 하수슬러지 가용 효과 연구)

  • Lee, Ji-Sun;Chang, In-Soung;Lee, Chul-Ku;Joung, Seun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.979-984
    • /
    • 2011
  • Although sludge production has been increased due to the number of the wastewater treatment plants expanded, needs of the techniques for the sludge reduction and disposal has been issued importantly because the sludge dumping to ocean is prohibited from 2012 by the London Dumping Convention. Therefore, the sludge solubilization using electrolysis as an alternative techniques for the sludge disposal was carried out in this study. Iridium coated titanium based insoluble electrodes were used and 20 volt was applied to the electrolysis reactor using DC power supply. Supernatants of the treated sludge was monitored: The soluble COD, TN, TP of it was increased to 151%, 22% and 6% respectively. And the sludge floc size distribution was changed, that is, the flocs ranged from 0.1 to 1.0 ${\mu}m$ were increased. All of these results indicate that the cells were lysed and the internal matters bursted out of the cell after electrolysis. As well as the reduction of the sludge production, the soluble organic matters from the cells could be used as an external carbon sources in the advanced wastewater treatment plants.

Hydraulic Stability Examination of Rainwater Reservoir Pipe Network System on Various Inflow Conditions (유입량 변화에 따른 도심지 내 우수저류조 관망시스템의 안정성 검토)

  • Yoo, Hyung Ju;Kim, Dong Hyun;Maeng, Seung Jin;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • Recently, as the occurrence frequency of sudden floods due to climate change increased, it is necessary to install the facilities that can cope with the initial stormwater. Most researches have been conducted on the design of facilities applying the Low Impact Development (LID) and the reduction effect on rainfall runoff to examine with 1D or 2D numerical models. However, the studies on the examination about flow characteristics and stability of pipe network systems were relatively insufficient in the literature. In this study, the stability of the pipe network system in rainwater storage tank was examined by using 3D numerical model, FLOW-3D. The changes of velocity and dynamic pressure were examined according to the number of rainwater storage tank and compared with the design criteria to derive the optimal design plan for a rainwater storage tank. As a results of numerical simulation with the design values in the previous study, it was confirmed that the velocity became increased as the number of rainwater storage tank increased. And magnitude of the velocity in pipes was formed within the design criteria. However, the velocity in the additional rainwater storage pipe was about 3.44 m/s exceeding the allowable range of the design criteria, when three or more additional rainwater storage tanks were installed. In the case of turbulence intensity and bottom shear stress, the bottom shear stress was larger than the critical shear stress as the additional rainwater storage was increased. So, the deposition of sediment was unlikely to occur, but it should be considered that the floc was formed by the reduction of the turbulence intensity. In addition, the dynamic pressure was also satisfied with the design criteria when the results were compared with the allowable internal pressure of the pipes generally used in the design of rainwater storage tank. Based on these results, it was suitable to install up to two additional rainwater storage tanks because the drainage becomes well when increasing of the number of storage tank and the velocity in the pipe becomes faster to be vulnerable to damage the pipe. However, this study has a assumption about the specifications of the rainwater storage tanks and the inflow of stormwater and has a limitation such that deriving the suitable rainwater storage tank design by simply adding the storage tank. Therefore, the various storage tank types and stormwater inflow scenarios will be asked to derive more efficient design plans in the future.