• Title/Summary/Keyword: 플로 상태

Search Result 62, Processing Time 0.022 seconds

Realtime Facial Expression Control of 3D Avatar by Isomap of Motion Data (모션 데이터에 Isomap을 사용한 3차원 아바타의 실시간 표정 제어)

  • Kim, Sung-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.9-16
    • /
    • 2007
  • This paper describe methodology that is distributed on 2-dimensional plane to much high-dimensional facial motion datas using Isomap algorithm, and user interface techniques to control facial expressions by selecting expressions while user navigates this space in real-time. Isomap algorithm is processed of three steps as follow; first define an adjacency expression of each expression data, and second, calculate manifold distance between each expressions and composing expression spaces. These facial spaces are created by calculating of the shortest distance(manifold distance) between two random expressions. We have taken a Floyd algorithm for it. Third, materialize multi-dimensional expression spaces using Multidimensional Scaling, and project two dimensions plane. The smallest adjacency distance to define adjacency expressions uses Pearson Correlation Coefficient. Users can control facial expressions of 3-dimensional avatar by using user interface while they navigates two dimension spaces by real-time.

An Experimental Study on the Durability and Load Carrying Capacity of RC Structure Repair System Using FR-ECC (고인성 내화보수모르터(FR-ECC)를 활용한 RC 구조물 보수공법의 내구성능 및 내하력에 관한 실험적 연구)

  • Kim, Jeong Hee;Lim, Seung Chan;Kim, Jae Hwan;Kwon, Yung Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.75-86
    • /
    • 2012
  • This paper presents some research results on the shrinkage characteristics and frost resistance before and after cracking of FR-ECC(Fire Resistance-Engineered Cementitious Composite). Also, a waterstop performance and exfoliating resistance of multi-layer lining specimens using FR-ECC and flexural performance of beam member by repaired FR-ECC are estimated in this paper. Experimental results indicate that the plastic shrinkage crack and length change ratio of FR-ECC have been reduced as compared with that of the existing repair mortar, and that its crack resistance on the dry shrinkage is improved under the confining stress. As well as FR-ECC has been great in the frost resistance and its tensile properties under the cracked state have been not reduced by freezing and thawing reaction. In addition, beam member by repaired FR-ECC have been increased in the flexural properties such as initial crack moment, yeild moment, and its crack width has been controled in a stable by the frexural failure.

A Study on the Detection of the Drilled Hole State In Drilling (드릴 가공된 구멍의 상태 검출에 관한 연구)

  • 신형곤;김태영
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.3
    • /
    • pp.8-16
    • /
    • 2003
  • Monitoring of the drill wear :md hole quality change is conducted during the drilling process. Cutting force measured by tool dynamometer is a evident feature estimating abnormal state of drilling. One major difficulty in using tool dynamometer is that the work-piece must be mounted on the dynamometer, and thus the machining process is disturbed and discontinuous. Acoustic transducer do not disturb the normal machining process and provide a relatively easy way to monitor a machining process for industrial application. for this advantage, AE signal is used to estimate the abnormal fate. In this study vision system is used to detect flank wear tendency and hole quality, there are many formal factors in hole quality decision circularity, cylindricity, straightness, and so of but these are difficult to measure in on-line monitoring. The movement of hole center and increasement of hole diameter is presented to determine hole quality. As the results of this experiment AE RMS signal and measurements by vision system are shorn the similar tendency as abnormal state of drilling.

A DSP based Three Phase Power Quality Analyzer for Motor Drives (모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템)

  • 김우용;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • This paper presents a digital instrument for a DSP based power quality analysis in three phase power system where current waveform is non-sinusoidal. it is based on stand alone type TMS320C31 DSP(digital signal processor)board and on a special high-speed data acquisition system. Power quality of low power motor drives are analyzed and processed by using a simple average power algorithm, and result of power analysis are displayed by LCD in the proposed system. This paper also goes on to discuss the performance of an instrument prototype, both in terms of accuracy and speed of measurement under the transient and steady state condition.

  • PDF

Monitoring System for Abnormal Cutting States in the Drilling Operation using Motor Current (모터전류를 이용한 드릴가공에서의 절삭이상상태 감시 시스템)

  • Kim, H.Y.;Ahn, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.5
    • /
    • pp.98-107
    • /
    • 1995
  • The in-process detection of drill wear and breakage is one of the most importnat technical problems in unmaned machining system. In this paper, the monitoring system is developed to monitor abnormal drilling states such as drill breakage, drill wear and unstable cutting using motor current. Drill breakage is detected by level monitoring. Tool wear is classified by fuzzy pattern recognition. The key feature for classification of tool wear is the estimated flank wear which is calculated by the proposed flank wear model. The characteristic of the model is not sensitive to the variation of cutting conditions but is sensitive to drill wear state. Unstable cutting states due to the unsmooth chip disposal and the overload are monitored by the variance/mean ratio of spindle motor current. Variance/mean ratio also includes the information about the prediction of drill wear and drill breakage. The evaluation experiments have shown that the developed system works very well.

  • PDF

Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System (전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석)

  • Oh, Kwan-Il;Jeon, Young-Soo;Park, Sang-Tae;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

The Development of a High Efficiency Luminaires Reflector for Tunnel Lighting (터널용 고효율 조명기구 반사판의 개발)

  • Kim, Gi-Hoon;Hwang, Jae-San;Yun, Mee-Rim;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.129-134
    • /
    • 2000
  • 우리 나라의 터널 조명은 운전자의 시야상태를 저해하는 불균일한 조도 균제도, 터널 내의 플리커 현상, 심한 눈부심 등과 함께 낮은 기구효율, 낮은 조명률, 높은 에너지 소비 등의 문제점을 갖고 있다. 이러한 것들을 개선하기 위해서 터널용 고효율 조명기구의 반사판을 개발하였고, 개발된 조명기구는 기구 자체 효율이 10%이상 상승함으로써 에너지의 절감과 조명효과의 상승을 가져왔으며, 기구 대수의 저감으로 건축비를 축소시켰다. 또한 이것을 이용한 터널조명에서는 평균조도 200[lx]이상, 전반 균제도 0.4이상, 차선축 균제도 0.7이상, 단위 면적당 소비전력 3.7 [W/$m^2$]이하의 효과를 얻었다.

  • PDF

Survey on the Medical Informatics in Disaster (재난상황에서의 의료 인포메틱스에 대한 연구 동향)

  • Jeon, Dong-Uk;Im, Yeong-Seon;Lee, Yeong-Hun
    • Information and Communications Magazine
    • /
    • v.29 no.5
    • /
    • pp.71-79
    • /
    • 2012
  • Medical Informatics에 대한 관심 증가와 정보통신 관련 기술이 발전됨에 따라 IT 기술을 활용한 의료 프로세스는 매우 활발히 사용되고 있으며, 재난 시 의료진의 접근이 제한된 가운데 단시간 내에 응급치료 및 수송과 효율적인 자원배분을 통한 대응은 각종 정보통신 관련기술의 발전과 함께 비약적으로 발전하고 있다. 본 논문에서는 Medical Informatics와 관련된 연구들을 분석하여 재난 상황에서 정보통신 기술을 활용한 의료 활동과 의료지원 시스템의 활용을 다룬다. 재난 상황 및 다수의 사상자가 발생하는 사고 현장에서 IT 시스템을 이용하여 보다 효과적으로 환자의 상태를 파악하여 분류함으로써 의료 활동의 효율을 높이는 방법에 대해 분석하고, 이를 위한 워크 플로의 정의 및 관련된 연구를 정리 하였다. 또한 무선통신기술의 활용, SNS 등을 이용한 의료정보의 전달과 이를 활용한 의료진의 대응 방법 대한 연구동향을 정리하였다. 이러한 정보기술의 발전은 재난에 대응하는 전략적 목표와 방법 등에서도 변화가 이루어지고 있어 이에 대한 연구동향을 포함하였다.

A study of improving impedance matching characteristic for process equipment of using RF plasma (RF 플라즈마를 사용하는 공정장비의 임피던스 정합특성 개선에 관한 연구)

  • Sul Yong-Tai;Park Suug-Jin;Lee Eui-Yong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.221-223
    • /
    • 2004
  • 본 논문에서는 RF 플라즈마를 사용하는 공정장비의 임피던스 정합 특성 개선을 위해 RF Match 제어단의 제어 알고리즘과 하드웨어의 디지털화 방안에 대한 연구를 수행하였다. 개발된 제어단은 최적의 동작성능을 위하여 멀티 프리셋, 이득제어 기능 등 부가기능을 갖도록 설계/제작하였고, 또한 LCD 모듈의 설치를 통하여 RF Match의 실시간 상태 파악이 가능하도록 하였다. 개발된 제어단에 대한 실험결과로부터 RF 전력의 over/under shoot, 플라즈마 플리커 등의 현상이 제거되었고, 정합시간이 크게 단축되었음을 알 수 있었다.

  • PDF

Effect of Replacement of 5~13mm Recycled Coarse Aggregates on Field Applicability of the Concrete through Mock-up Test (목업 시험을 통한 5~13mm 순환 굵은골재 치환 사용이 콘크리트의 현장적용성에 미치는 영향 고찰)

  • Han, Min-Cheol;Song, Young-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 2017
  • The objective of this paper is to investigate experimentally the effect of replacement of recycled coarse aggregates with 5~13mm in size on a field applicability of concretes through Mock-up test. Seven different mock-up specimens were prepared with the size of $1200{\times}800{\times}800mm$ simulating column and wall. For the concrete mixtures, 24MPa, 27MPa and 40MPa of nominal strength were adopted with 30% and 70%(only for 24MPa) of 5~13mm recycled coarse aggregate (RCA) replacement and without 5~13mm RCA(Plain). For test items, slump, slump flow, compressive strength with different curing conditions, core drilling, rebound numbers and drying shrinkage were measured. Test results indicated that 30% of 5~13 mm RCA replacement resulted in increase in slump, slump flow and resistance against segregation, while air contents decreased compared to those of plain mixture. Compressive strength of concrete with 30% of 5~13mm RCA was shown to be higher than that of plain mixture due to optimum packing effect associated with presence of well graded aggregates. Rebound number of the mock-up specimen with 30% of 5~13mm RCA had lower fluctuation according to hitting location than that of plain mock-up specimen. It is believed from the results of the study that replacement of 30% of 5~13mm RCA brings desirable improvement in various aspect of concrete performance due to associated dense packing effect.