• Title/Summary/Keyword: 플랜트 응답

Search Result 97, Processing Time 0.035 seconds

Design of Dual Fuzzy Logic Controller using $e-{\Delta}e$ Phase Plane for Hydraulic Servo Motor (유압 서보 모터를 위한 $e-{\Delta}e$ 위상평면을 이용한 이중 퍼지 로직 제어기 설계)

  • Shin, Wee-Jae;Moon, Jeong-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.222-226
    • /
    • 2007
  • In this paper we composed the dual fuzzy rules using each region of specific points and $e-{\Delta}e$ phase plane In order to make dual fuzzy rule base. We composed the fuzzy control rules which can decrease rise time, delay time, maximum overshoot than basic fuzzy control rules. proposed method is alternately use at specific points of $e-{\Delta}e$ phase plane with two fuzzy control rules that is one control rule occruing the steady state error in transient region and another fuzzy control rule use to decrease the steady state error and rapidly converge at the convergence region. Also, two fuzzy control rules in the $e-{\Delta}e$ phase plane decide the change time according to response characteristics of plants. In order to confirm thef proposed algorithm. As the results of experiments through the hydraulic servo motor control system with a DSP processor, We verified that proposed dual fuzzy control rules get the good response compare with the basic fuzzy control rule.

  • PDF

The Strategy Design of Control Logic for Ultra Super-Critical Power Plant Boiler (초초임계압 발전소 보일러 제어전략 설계)

  • Park, Doo-Yong;Kim, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.223-224
    • /
    • 2008
  • 초초임계압 화력발전 제어계통 설계와 관련하여 보일러 제어시스템의 기본 요건인 제어전략을 구현하기 위해 현재 표준화력 500MW 제어시스템과 제어로직을 기반으로 1000MW급에서 필요로 하는 새로운 구조의 제어에 요구되는 제어전략에 대해 각종 제어 운전 모드의 구성과 각 운전 모드에서의 제어전략을 개발하고 있다. 최신제어시스템에서 중요하게 취급되는 자동 플랜트 제어(Automatic Plant Control, APE)의 각종 제어전략 구성에 중점을 두고 있으며 Unit Master Control, Boiler Master Control, Turbine blaster Control, Throttle Pressure Control, Fuel/Air Master Control, Forced Draft Fan Control, Induced Draft Fan Control, Primary Air Fan, Feed Water Master Control, Super Heater/Reheater Steam Temp Control 등의 제어전략을 논하고, 실제 프로세스 응단특성 파악을 위해 국내 신규발전소를 방문하여 수집한 프로세스 응답시험 결과와 특성을 분석하고 USC에 적용하기위한 보일러 제어전략에 대해 논하고자 한다.

  • PDF

퍼지 추론에 의한 제어방법

  • 변증남;김동화
    • 전기의세계
    • /
    • v.39 no.12
    • /
    • pp.21-32
    • /
    • 1990
  • 퍼지 논리를 이용한 제어시스템에 관하여 핵심 개념을 중심으로 기술하고자 한다. 요약컨데 이 퍼지제어기의 특징은 1) Parallel(distributed) control 2) logic control 3) linguistic control등이며 퍼지 제어가 효과적일 수 있는 제어대상(plant)로서는 수학적 모델을 적용하기 힘든 시스템으로서 경험적으로 또는 수동적인 방법으로 제어가 잘되고 있는 대상을 들 수 있다. 그 뿐만 아니라 간단한 제어기가 필요한 경우로서 보다 효과적인 제어측 Software를 쓰거나 센서 또는 필터없이 사용가능하고, Inverted Penedulum의 자세 제어처럼 정확성보다는 속도 응답 제어가 요구되는 경우 등에 효과적으로 쓸 수 있는 것으로 알려지고 있다. Fuzzy 제어는 지식 베이스의 규모에서 인공지능형 Expert System보다 Compact하고 선형.비선형 플랜트에 공히 이용될 수 있으며, 설계자는 오퍼레이터와의 접촉을 통해 룰을 구축하므로 사용자가 시스템을 이해하기 쉬운 잇점등이 있기도 한다. 그러나 가장 큰 문제는 구축해 놓은 시스템의 안전성(Stability)를 이론적으로 사전에 검증하기가 어렵고, 같은 제어대상이라 할지라도 추론방법, 소속함수의 형태선택, 룰수 등에 따라 제어성능이 바뀔수 있으나, 무엇이 어떤 영향을 주는지 규명되지 않은점 등 여러가지 연구되어야 할 내용이 많이 있다.

  • PDF

Control of Systems Containing Deadzone of PID Controller using Fuzzy Compensator and Fuzzy Tuner (퍼지 보상기와 퍼지 동조기를 이용한 PID제어기의 Deadzone을 포함한 시스템 제어)

  • 박재형;김승철;조용성;최부귀
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.403-410
    • /
    • 1999
  • A conventional PID controller has poor performance when it applied to systems with unknown deadzones. To solve this problem, this paper proposes PID controller using two layered-fuzzy logic. The structure of controller is reconstructed with fuzzy compensator and fuzzy tuner on the conventional PID controller. Our proposed control scheme shows superior transient and steady-state performance compared to conventional PID controller. The scheme is robust to variations in deadzone nonlinearities as well as the steady-state gain of the plant. The performance of the developed controller is verified through simulation.

  • PDF

Improved Response of the Plant with an Integrator and Long Dead Time (적분기와 큰 시간지연을 가지는 플랜트에 대한 응답특성 개선)

  • Yang, Seung-Hyun;Park, Yong-Sik;Hur, Myung-Jun;Lee, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.515-517
    • /
    • 1999
  • This paper considers the design of the effective controllers for the plant with an integrator and a long deadtime. The structure of the new DTC(DeadTime Compensator) that has an additive filter is proposed. Our DTC shows the improved performance in set-point response and disturbance rejection. Especially the bad effect of the long deadtime in the disturbance rejection is fairly reduced by using the additive filter. Illustrative examples are provided to show the availability of the proposed controller.

  • PDF

A Study on Mathematical Modeling of Forcing Function for the Piping Vibration of Petrochemical Plant Design (플랜트 설계 시 배관진동을 유발하는 가진 함수의 수학적 모델링)

  • 민선규;최명진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.591-595
    • /
    • 1997
  • In analysis of piping vibration of petrochemical plant, the forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used for the system with rotary equipments. Mechanical driving frequencies, wave functions, and response spectrum are used for reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, for the spray injection case inside the pipe, forcing function was modeled, in which two different fluids are distributed uniformly. To confirm the results, the scheme used for the forcing function was applied for real piping system. The vibration mode of the real system was consistent with the 4th mode obtained by simulation using the forcing function formulated in this study.

  • PDF

Position Control of Arago's Pendulum System by using Kalman Filter (칼만필터를 이용한 아라고 진자 시스템의 위치제어)

  • Park, Tae-Dong;Youn, Su-Jin;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1765-1766
    • /
    • 2008
  • 본 논문에서는, 전동기를 이용하는 위치제어 시스템을 이용하여, 이너루프 제어기 유무에 따라 시간 응답 특성 개선 효과에 대하여 실험을 통해 검증하고자 한다. 실험 플랜트로서, 전동기의 속도에 따라 진자의 위치를 제어하는 다중 안정도를 가지고 비선형 시스템인 아라고 진자 시스템을 이용한다. 이 시스템은 속도 정보를 알 수 있는 측정 장치가 없는데, 칼만필터로 전동기의 속도를 추정하고 속도 제어기를 설계하도록 한다. 또한, 선형 시스템을 고려하기 위하여 안정영역 동작점인 진자의 각도가 지면으로 부터 45$^{\circ}$인 선형화 모델을 이용한다.

  • PDF

Multivariable Controller Design for Nuclear Power Plant Using INA Method (INA 법을 이용한 원자력 발전소의 다변수 제어기 설계)

  • Dong-Hwa Kim;Suk-Kyo Hong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.10
    • /
    • pp.1086-1097
    • /
    • 1990
  • The design of multivariable control systems using the Inverse Nyquist Array method is described in this paper. The INA is a simple design technique, which permits a designer to achieve his objectives for a controller specification in a step-by-step fashion using Gershgorin band and Ostrowski circle. The application to a multivariable system of CANDU nuclear power plant with 5 inputs, 8 outputs, and 24 state variables is reviewed and the simulation shows satisfactory results.

A Simulation of Forcing Function for the Piping Vibration in Petrochemical Plants (석유화학 플랜트에서 배관 가진 함수의 시뮬레이션에 관한 연구)

  • 민선규;최명진;김경훈
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.1-10
    • /
    • 2001
  • For the simulation of piping vibrations in petrochemical plants, forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used to simulate rotary equipment. Mechanical driving frequencies, wave functions, and response spectrum are used to simulate reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, the general suggestions for forcing functions were reviewed and proposed the forcing function to simulate the spray injection system inside the pipe in which two different fluids are distributed uniformly. To confirm the results, the scheme was applied for a real piping system. The vibration mode of the real system was consistent with the 4th mode (26.725 Hz) obtained by simulation using the forcing function presented in this study.

  • PDF

Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part A: Analysis for the Explosion Load Characteristics and the Effect of Explosion Loading Rate on Structural Response - (폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part A: 폭발하중 특징 및 재하속도의 영향 분석 -)

  • Kang, Ki-Yeob;Choi, Kwang-Ho;Ryu, YongHee;Choi, JaeWoong;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.187-195
    • /
    • 2015
  • The gas explosions in offshore installations are known to be very severe according to its geometry and environmental conditions such as leak locations and wind directions, and a dynamic response of structures due to blast loads depends on the load profile. Therefore, a parametric study has to be conducted to investigate the effects of the dynamic response of structural members subjected to various types of load shapes. To do so, a series of CFD analyses was performed using a full-scale FPSO topside model including detail parts of pipes and equipments, and the time history data of the blast loads at monitor points and panels were obtained by the analyses. In this paper, we focus on a structural dynamic response subjected to blast loads changing the magnitude of positive/negative phase pressure and time duration. From the results of linear/nonlinear transient analyses using single degree of freedom(SDOF) and multi-degree-of freedom(MDOF) systems, it was observed that dynamic responses of structures were significantly influenced by the magnitude of positive and negative phase pressures and negative time duration.