• Title/Summary/Keyword: 풍력발전 가능성

Search Result 71, Processing Time 0.032 seconds

Possibility of Wind Power Generation by a Vehicle-Induced Wind at the Median Strip on Hightway (주행차량에 의한 중앙분리대 유도풍의 풍력발전 활용 가능성)

  • Woo, Sang-Woo;Kim, Hyun-Goo;Jang, Moon-Seok;Shin, Hyung-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.315-317
    • /
    • 2008
  • The purpose of this study is to confirm the possibility of wind power generation by a vehicle-induced at the median strip on highway. In order to find out wind field information, a CFD method was used. According to the simulation results, the x, y, z-component of the wind velocity around a median strip are rapidly changed at near before and behind a moving vehicle. The x-component of the wind velocity appears high within the range of the length of the passing vehicle, and the wind direction appeared in the opposite direction at the behind of a vehicle. However, x and y-components of the wind velocity at the behind of vehicle are shown constantly. We confirmed possibility of wind power generation using a vehicle-induced wind at the median strip.

  • PDF

Assessment for Development Capacity of Offshore Wind Power Around Korean Peninsula (국내 해역의 해상풍력 개발 가능량 평가)

  • Kim, Ji-Young;Kang, Keum-Seok;Oh, Ki-Yong;Lee, Jun-Shin;Jang, Moon-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.500-503
    • /
    • 2009
  • 국내 해역의 해상풍력 개발 가능량을 평가하기 위하여 풍황, 수심 등을 고려하여 개발 가능량을 추정하였다. 풍력등급 3 이상, 수심 50 m 이내의 영역에 대하여 사회.환경적 영향을 고려하기 위한 제약조건을 반영하여 개발 가능량을 산출하였으며, 현재의 기술수준으로 개발 가능하다고 판단되는 수심 30 m 이내의 영역에 대한 개발 가능용량이 약 11 GW 정도로 추정됨에 따라 풍력발전 용량을 2030년까지 7.3 GW 이상 확보하고자 하는 국가 신재생에너지 보급목표의 달성 가능성이 기대된다. 본 연구결과는 해상풍력 개발단지 선정을 위한 기초 자료로 활용되며, 입지 선정 후 기상관측, 환경영향조사 등의 세분화된 단지조사를 통한 해상풍력 실증단지 설계 및 경제성 평가 등이 계속 진행될 예정이다.

  • PDF

특집(스마트 그리드의 발전방향) - 신 에너지전원이 연계된 배전계통의 양방향 보호협조 방안에 관한 연구

  • No, Dae-Seok
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.393
    • /
    • pp.51-57
    • /
    • 2009
  • 최근, 국가적인 차원에서 추진되고 있는 풍력발전, 태양광발전 등과 같은 신 에너지전원(분산전원)은 기존의 전원에 비하여 소규모 전원인 관계로 주로 수용가에 가까운 배전계통에 도입되어지고 있으며, 그 특성상 배전계통과 연계하여 운전함으로써 보다 안정된 전력의 확보 및 전력설비의 효율적인 활용, 자원의 효율적인 이용 등의 이점을 얻을 수 있다. 한편, 태양광과 풍력 등의 자연에너지를 이용한 분산전원은 일정한 출력을 내는 기존의 전원보다 기후나 온도, 지형적인 영향을 많이 받는 간헐적인 전원이의로, 이들이 도입된 배전계통은 기존의 단 방향 공급형태의 배전계통과는 달리 부하와 전원이 혼재되어 운용되는 형태로 된다. 분산전원이 연계된 배전계통의 경우에는 분산전원의 출력 용량 여부에 따라 양방향의 전력조류가 발생할 가능성이 있어, 계통운용상 여러 가지 문제점이 야기될 수 있다. 따라서 본 연구에서는 분산전원 연계에 따른 보호협조 기본 방안과 부하절체 운전과 변압기결선에 따른 보호협조 방안 등에 대한 알고리즘을 제시하였다. 또한, 이론적인 계산법(대칭좌표법)에 의하여 실 계통에서의 양방향 보호협조에 관련된 문제점을 분석하고, 해결방안을 제시하였다.

  • PDF

Structural analysis and safety design of composite wind turbine blades considering static loads (정적 하중을 고려한 풍력 터빈 복합재 블레이드의 구조해석과 안전도 설계)

  • Choi, Jaeheok;Lee, Jaehwan;Shin, SangJoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.57.1-57.1
    • /
    • 2011
  • 본 논문에서는 소음을 저감하고 구조적 안전도를 향상시키기 위하여 10kW급 소형 복합재 풍력터빈 블레이드를 해석, 설계하였다. 풍력터빈 블레이드 설계의 기본 사항에 맞추어 블레이드의 스팬 길이는 약 4m, 중량은 30kg 내외가 되도록 설정하였다. 풍력발전기용 블레이드는 경량화가 중요하므로 유리섬유복합재 (glass fiber reinforce pastics), 탄소섬유복합재 (carbon fiber reinforced plastics)가 사용되었다. 본 설계에서는 Carbon prepreg (WSN3KY), Carbon UD(UIN150c), E-glass 등을 사용하였다. 상용 유한요소 프로그램인 NASTRAN을 이용해 Carbon prepreg (WSN3KY), Carbon UD (UIN150c)의 탄소섬유복합재만으로 구성된 블레이드 구조해석을 수행한 결과 중량 조건 및 강도의 안전도는 충족되었으나, 높은 가격을 감안하여 E-glass와 조합하여 블레이드를 재설계할 예정이다. 이번 설계는 소형 풍력발전용 블레이드 설계이므로 좌굴은 고려하지 않았으며, 향후 필요에 따라서 좌굴 및 피로해석도 수행하여 검증할 예정이다. 그리고 블레이드가 복합재로 구성되면 감쇠력이 감소할 가능성이 있다. 탄소섬유복합재로만 구성된 블레이드 구조해석에서도 최대 40cm의 변형이 예측되었으며, 감쇠값 저하 문제도 고려하여야 될 것 같아 BEMT (Blade Element Momentum Theory) 공력모델을 이용해 구조-유체 연성 결합 해석을 수행할 계획이다.

  • PDF

A Feasibility Study on the Wind Power Plant for Common Residential Buildings in Youngdo Island, Busan (부산 영도구 공동주택에 대한 풍력발전 도입가능성)

  • Hwang, Kwang-Il;Kim, Jee-Hun;Shin, Hyoun-Ho;Lee, Su-Ho;Han, Je-Deok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.255-256
    • /
    • 2006
  • A wind power plant is one of the competitive and effective energy among the regulated 13 renewable energies, especially for the seashore and island. This study is focused on the possibility of wind power plant as a on-site electric power supply system for the common residential building in Youngdo, Busan. The following show the results of this study. 26 apartments' monthly electric power consumptions are surveyed and monthly variations are stable comparing to the metropolitan. With the wind speed measured in Youngdo island and wind power plant efficiency data, the simulation is conducted and the result shows that 35 wind power units are satisfied with full electric power load for all the common residential buildings in Youngdo island.

  • PDF

Experimental Study of Small Vertical Axis Wind Turbine according to Type of Blades (블레이드 형태에 따른 소형 수직축 풍력발전기의 실험적 연구)

  • Lee, Min-Gu;Oh, Hun;Park, Wal-Seo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.88-92
    • /
    • 2017
  • Owing to the depletion of fossil energy, wind power is attracting attention as a promising environmentally friendly alternative energy source, because it is abundant, renewable, and non-polluting. Wind turbines are divided into horizontal axis wind turbines (HAWTs) and vertical axis wind turbines (VAWTs) according to the direction of the rotating shaft. VAWTs have a low power generation efficiency, but are not affected by the wind direction and, thus, no yaw system is required and their structure is simple. Small VAWTs are attracting much attention because they can generate power even at low wind speeds. In this study, the output voltages and output currents of small VAWTs with gyromill type, hinge type and double door type blades capable of generating power even at low wind speeds were analyzed at variable wind speeds in the range of 1~11 m/s. At the maximum wind speed of 11m/s, the application of the double door type blades achieved 67% and 9% higher wind turbine output voltages than that of the gyromill type and hinge type blades, respectively. As regards the wind turbine output currents, the application of the double door type blades gave rise to 93% and 5% higher results than that of the gyromill type and hinge type blades, respectively. Through this study, the excellent output characteristics and commercialization potential of the double door type blades, which can generate power both at low and high wind speeds, were confirmed.

Study on Potential Utility of Wind Power Generation Based on Driving Wind of High-Speed Trains (고속철도 열차 주행풍의 풍력발전 활용성에 대한 연구)

  • Kim, Je-Guen;Suh, Ki-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.681-687
    • /
    • 2017
  • We investigated the potential for wind-power generation using the wind produced by express trains. We built equipment to detect the wind velocity, including wind meters and a data analyzer. We considered various conditions that might change the wind. First, we measured the velocity and duration of the wind at three locations distinguished by the presence of a tunnel and a valley landscape. We analyzed the changes in the wind according to the geometric conditions. Also, we analyzed the changes in the wind according to three different heights relative to the train. We also compared the wind produced by a KTX train and an SRT train. Finally, we used the results to derive the wind power energy harvested from the wind and discuss the expected utility.

A Study on the Optimal Solar Power System for 10kW Wind Power in the Mokpo Seaside (목포해안지역의 10kW급 풍력과 최적의 태양광 복합발전시스템에 관한 연구)

  • Cho, Dong-Hoon;Bae, Cherl-O;Park, Young-San
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.1 s.28
    • /
    • pp.69-73
    • /
    • 2007
  • As the interest in environmental pollution increases, the use of renewable energy is uprising. Among the renewable energy resources, wind and solar energy have no environmental impact and they can be used as unlimited resources. The two power systems are mutual supplementary systems. So the two systems are usually combined for generation. We have measured several data about wind and solar. These data can be used the foundation data for the construction of wind and solar power generation plants. Also we analyzed the possible optimal solar power system for 10[kW] wind power.

  • PDF

Evaluation Algorithm for Under-Reach of Protection Devices in Distribution System with Distributed Generation (분산전원이 연계된 배전계통의 보호기기 부동작 평가 알고리즘)

  • Kim, So-Hee;Heo, Sang-Wn;Rho, Dae-Seok;Seo, In-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.673-674
    • /
    • 2011
  • 정부의 녹색성장 정책에 의해 배전계통에 태양광, 풍력발전 등 분산전원의 설치가 급증함에 따라 기존의 배전계통의 조류의 방향 및 고장전류, 부하전류가 변화되어 배전계통의 보호협조 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 특히 분산전원연계시 임피던스 병렬화로 보호기기에 흐르는 사고전류가 감소하는 분류효과가 발생할 가능성이 있다. 따라서 본 논문에서는 분산전원이 연계된 경우 보호협조를 검토하기 위한 양방향 보호협조 평가프로그램을 이용하여 분산전원이 연계된 경우 계통에서 발생할 수 있는 문제점 중 분류 효과로 인한 보호기기의 부동작 사례를 시뮬레이션하고, 그 결과를 분석하여 본 프로그램의 유용성을 확인하였다.

  • PDF

신 에너지전원이 연계된 스마트그리드의 양방향 보호협조에 대한 운용방안

  • No, Dae-Seok
    • 전기의세계
    • /
    • v.59 no.9
    • /
    • pp.39-45
    • /
    • 2010
  • 최근 배전계통에 연계되고 있는 태양광, 풍력발전 등과 같은 신 에너지전원의 용량은 점차 증가하고 있는 상황이지만, 설치자(신 에너지전원 소유자)의 보호방식은 기존 방식을 고수하고 있는 실정으로 신 에너지전원의 역 조류에 의해 설치자의 보호기기(자동화기기 포함)의 오 부 동작 발생 가능성이 커지고 있다. 따라서 본 논문에서는 신 에너지전원이 배전계통에 연계되어 운전되는 경우에 발생 가능한 보호협조의 문제점을 분석하고 이에 대한 대책 방안을 제시한다. 신 에너지전원의 역 조류에 의한 배전계통의 보호협조에 대한 문제점은 크게 3가지로 분류할 수 있는데, 신 에너지전원의 사고전류공급에 의한 보호기기의 정격차단용량(12.5KA)의 상회 가능성과 신 에너지전원의 연계로 인한 임피던스 병렬화로 사고전류의 감소로 발생할 수 있는 분류효과에 의한 보호기기의 부 동작, 연계용변압기의 결선방식에 의한 보호기기의 오동작으로 나눌 수 있다. 여기서는 이에 대한 문제점을 대칭좌표법을 이용하여 구체적으로 해석하고, 이에 대한 최적 운용방안을 제시한다.

  • PDF