• Title/Summary/Keyword: 평행 와이어

Search Result 211, Processing Time 0.024 seconds

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

Optical Absorption and Polarogram of Macrocyclic Nickel (II) Complexes in Polar Solvents (극성용매에서 거대고리 Ni (II) 착물의 광흡수와 폴라로그램)

  • Park Yuj-Chul;Jong-Chul Byun
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.168-177
    • /
    • 1987
  • The equilibria of chemical reaction between $\alpha$-Ni(rac-[14]-decane)$^{2+}$ and polar solvents(L; ANT, MFA, DMSO, DMF, and DMA) have been investigated by the spectrophotometric method at $25^{\circ}C$. (The equilibrium constants($K_1$) of) the first step in ANT, MFA, DMSO, DMF, and DMA were 31.0, 27.5, 21.3 15.9, and 6.4, respectively. The smallness of equilibrium constants ($K_2$) of the second step compared with $K_1$, was observed. $\alpha$-Ni(rac-[14]-dacane)$^{2+}$ + L $\leftrightharpoons$ [$\alpha$-Ni(rac-[14]-decane){\cdot}L]$^{2+}$ : $K_1$.[$\alpha$-Ni(rac-[14]-decane){\cdot}L)$^{2+}$+ L $\leftrightharpoons$ [$\alpha$-Ni(rac-[14]-decane){\cdot}$L_2$)$^{2+}$ :$K_2$. The relationship between d-d absorption energy and half-wave potential of complex ions at ACT was considered. Macrocyclic ligands increasing d-d transition energy caused half-wave potentials of Ni(II)-macrocycle to be shifted more positively. The half-wave potentials for Ni(rac-1[14]7-diene)$^{2+}$, Ni(meso-1[14]7-diene)$^{2+}$, Ni(1[14]4-diene)$^{2+}$, $\alpha$-Ni(rac-[14]-decane)$^{2+}$, ${\beta}-Ni(rac-[14]-decane)$^{2+}$, and Ni(meso-[14]-decane)$^{2+}$ reductions were -1.419, -1.431, -1.450, -1.473, and -1.480 (V vs. SCE), respectively. The d-d transition energies ($\nu_{max},\;cm^{-1}$) of the Ni(meso-[14]-decane)$^{2+}$ isomer were discussed with the dielectric constant (${\varepsilon}/{\varepsilon}_0$) of the various solvents, $\nu_{max}(cm^{-1})$ increased with increasing ${\varepsilon}/{\varepsilon}_0$.

  • PDF

A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION (Sealed amalgam restoration의 미세누출에 관한 연구)

  • Lee, Sang-Heon;Lee, Jae-Cheoun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • Amalgam, though a widely used dental material, does not bond to the tooth substrate Therefore, retentive preparation of the cavity is necessary. Such amalgam restorations, until corrosion products form and plug the margin, will show significant marginal leakage. Unless this is prevented early on, saliva and bacteria may enter the cavity causing postoperative hypersensitivity, dissolution and collapse of the restoration, discoloration of the margin and secondary caries, leading to shortened life-span of the restoration and pulpal pathosis. Recently, a method of restoration has been introduced whereby tooth material can be preserved, cavity margin can be sealed and preventive treatment of pit and fissure can be administered while retaining all the advantages of conventional amalgam restorations. Such sealed amalgams involve removing the carious lesion without extending the cavity for prevention and using pit and fissure sealants to seal cavity margins and pit and fissures to reduce microleakage. In this study, finishing of the amalgam and sealant application were performed after different intervals following of amalgam restoration to compare the microleakage of sealed and conventional amalgam restorations. Thirty bicuspids were prepared with Class V cavity preparations on the buccal and lingual surfaces. After amalgam placement, they were divided into the following groups and treated accordingly. Group 1 : Polishing after 24 hours Group 2 : Immediate sealant application without polishing Group 3 : No polishing, but sealant applied after thermocycling 500 times After treatment, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue kept in a $37^{\circ}C$ incubator at 100% humidity for 24 hours. The teeth were then embedded in resin and cut bucco-lingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage, The following results were obtained : 1. Group 2 showed the least microleakeage, while group 1 showed the greatest. 2. Group 1 showed significantly greater microleakage compared to group 2 (p<0.05). However, no significant differences were found between group 1 and 3(p>0.05). No significant differences in microleakage were also found between cup 2 and 3(p<0.05).

  • PDF

Modification of Trunk Thickness of MIRD phantom Based on the Comparison of Organ Doses with Voxel Phantom (체적소팬텀과의 장기선량 비교를 통한 MIRD팬텀 몸통두께 수정)

  • Lee, Choon-Sik;Park, Sang-Hyun;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.199-206
    • /
    • 2003
  • Because the MIRD phantom, the representative mathematical phantom was developed for the calculation of internal radiation dose, and simulated by the simplified mathematical equations for rapid computation, the appropriateness of application to external dose calculation and the closeness to real human body should be justified. This study was intended to modify the MIRD phantom according to the comparison of the organ absorbed doses in the two phantoms exposed to monoenergetic broad parallel photon beams of the energy between 0.05 MeV and 10 MeV. The organ absorbed doses of the MIRD phantom and the Zubal yokel phantom were calculated for AP and PA geometries by MCNP4C, general-purpose Monte Carlo code. The MIRD phantom received higher doses than the Zubal phantom for both AP and PA geometries. Effective dose in PA geometry for 0.05 MeV photon beams showed the difference up to 50%. Anatomical axial views of the two phantoms revealed the thinner trunk thickness of the MIRD phantom than that of the Zubal phantom. To find out the optimal thickness of trunk, the difference of effective doses for 0.5 MeV photon beams for various trunk thickness of the MIRD phantom from 20 cm to 36 cm were compared. The optimal thunk thickness, 24 cm and 28 cm for AP and PA geometries, respectively, showed the minimum difference of effective doses between the two phantoms. The trunk model of the MIRD phantom was modified and the organ doses were recalculated using the modified MIRD phantom. The differences of effective dose for AP and PA geometries reduced to 7.3% and the overestimation of organ doses decreased, too. Because MIRD-type phantoms are easier to be adopted in Monte Carlo calculations and to standardize, the modifications of the MIRD phantom allow us to hold the advantage of MIRD-type phantoms over a voxel phantom and alleviate the anatomical difference and consequent disagreement in dose calculation.

Gravity Field Interpretation for the Deep Geological Structure Analysis in Pohang-Ulsan, Southeastern Korean Peninsula (한반도 남동부 포항-울산지역 심부 지질구조 분석을 위한 중력장 해석)

  • Sohn, Yujin;Choi, Sungchan;Ryu, In-Chang
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.597-608
    • /
    • 2020
  • Even after the Gyeongju earthquake and the Pohang earthquake, hundreds of aftershocks and micro-earthquakes are still occurring in the southeastern part of the Korean Peninsula. These phenomena mean that the stress is constantly working, implying that another huge earthquake may occur in the future. Therefore, the gravity field interpretation method was used to analyze the deep geological structure of the Pohang-Ulsan region in the southeastern Korean Peninsula. First, a gravity survey was performed to collect the insufficient data and to calculate the detailed Bouguer gravity anomaly in the study area. Based on the gravity anomaly data, the location, direction, and maximum depth of deep fault lines were analyzed using the inversion methods "Curvature analysis" and "Euler deconvolution method". As a result, it is interpreted that at least six fault lines(C1~C6) exist in deep depth. The deep fault line C1 is well correlated to the Yeonil Tectonic Line(YTL), suggesting that YTL is extended up to about 4000m deep. The deep fault line C2 consists of several segment faults and well correlated to the fault lines on the surface. Inferred fault lines C3, C4, and C5 have an NW-SE direction, which is parallel to the Ulsan fault. The deep fault line C6 has the direction of NE-SW, and it is interpreted that the eastern boundary fault of Eoil Basin is extended to the deep. Comparing the inferred fault lines with the distribution of micro-earthquakes, the location of the deep fault line C1 is well correlated to the hypocenter of micro-earthquakes. This implies that faults in deep depth are related to the recent earthquakes in the southeastern Korean Peninsula.

Chitosan and Acetylchitosan from Squid Pen and Their Characteristics (오징어 연골을 이용한 Chitosan 및 Acetylchitosan의 제조와 특성)

  • CHOI Hyeon-Mee;HWANG Sun-Young;PARK Seong-Min;LEE Keun-Tai
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.5
    • /
    • pp.563-569
    • /
    • 2001
  • In order to utilize the processing wastes of squid, chitosan was prepared by intermittent deacetylation treaoent of $\beta-chitin$ contained richly in the pen of squid. Acetylchitosan also was synthesized from squid pen chitosan with anhydrous acetic acid and their characteristics were investigated. The amounts of nitrogen and ash of squid pen chitosan were $5.80.2\% and 0.2\pm0.03\%$ respectively, the yield of squid pen chitosan was $25\pm3\%$, the degree of deacetylation was $92\%$, and the molecular weight was $1.15\times10^6$, Acetyl contents of N-acetylchitosan powder, acetylchitosan bead, N-ACF-1 (N-acetylchitosan film-1) and N-ACF-2 (N-acetylchitosan film-2) were $55.9\%, 63.2\%, 56\% and 58.7\%$ respectively. Two major peaks, amide I ($1,653 cm^{-1}$) and II ($1,558 cm^{-1}$) bent, on FT-IR spectra of the N-acetylchitosan from squid pen were almost similar to these of $\beta-chitin$, While there was a broad single peak at $1,601 cm^{-1}$assigned to be an amide I bend in squid pen chitosan. The CP/MAS NMR spectra of $\beta-chitin$, squid pen chitosan and N-acetylchitosan from squid pen showed a relative broad and single peak at 74 ppm assigned to fifth carbon (C-5) and third carbon (C-3). In case of $\beta-chitin$ and N-acetylchitosan from squid pen, single peak at 74 ppm was showed as the same of $\beta-chitin$ type.

  • PDF

Time-relationship between Deformation and Growth of Metamorphic Minerals around the Shinbo Mine, Korea: the Relative Mineralization Time of Uranium Mineralized Zone (신보광산 주변지역에서 변성광물의 성장과 변형작용 사이의 상대적인 시간관계: 우라늄 광화대의 상대적인 광화시기)

  • Kang, Ji-Hoon;Lee, Deok-Seon
    • Economic and Environmental Geology
    • /
    • v.45 no.4
    • /
    • pp.385-396
    • /
    • 2012
  • The geochemical high-grade uranium anormal zone has been reported in the Shinbo mine and its eastern areas, Jinan-gun, Jeollabuk-do located in the southwestern part of Ogcheon metamorphic zone, Korea. In this paper is reported the time-relationship between deformation and growth of metamorphic minerals in the eastern area of Shinbo mine, which consists of the Precambrian metasedimentary rocks (quartzite, metapelite, metapsammite) and the age-unknown pegmatite and Cretaceous porphyry which intrude them, and is considered the relative mineralization time on the basis of the previous research's result. The D1 deformation formed the straight-type Si internal foliation which is defined mainly as the arrangement of elongate quartz, biotite, opaque mineral in andalusite porphyroblast. The D2 deformation, which is defined by the microfolding of Si foliation, formed S2 crenulation cleavage. It can be divided into two sub-phases, early crenulation and late crenulation. The former occurs as the curvetype Si foliation in the mantle part of andalusite. The latter occurs as S1-2 composite foliation which warps around the andalusite. The andalusite porphyroblast began to grow under non-deformation condition after the formation of S1 foliation which corresponds to the straight-type Si foliation. It continued to grow before the late crenulation phase. The age-unknown pegmatite intruded after the D2 deformation and grew the fibrous sillimanite which random masks the S1-2 composite foliation. The D3 deformation formed F3 fold which folded the S1-2 composite foliation, D2 crenulation, fibrous sillimanite. It means that the intrusion of pegmatite related to the growth of the fibrous sillimanite took place during the inter-tectonic phase of D2 and D3 deformations. The retrograde metamorphism is recognized by the chloritization of biotite and two-way cleavage lamellae which is parallel to the S1-2 composite foliation and the F3 fold axial surface in the andalusite porphyroblast. It occurred during the D2 late crenulation phase and D3 deformation. In considering of the previous research's result inferring the most likely candidate for the uranium source rock as pegamatite, it indicates that the age-unknown pegmatite intruded during the inter-tectonic phase of D2 and D3 deformations, i.e. during the retrograde metamorphism related to the uplifting of crust, and formed the uranium ore zone around the Shinbo mine.

EFFECT OF A NEW RESIN MONOMER ON THE MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (새로운 레진 단량체가 복합레진수복물의 미세변연누출에 미치는 영향)

  • Bae, J.H.;Kim, Y.K.;Yoon, P.Y.;Lee, M.A.;Cho, B.H.
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.469-475
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of a new resin monomer on the microleakage of composite resin restorations. By adding new methoxylated Bis-GMA (Bis-M-GMA, 2,2-bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane) having low viscosity, the content of TEGDMA which has adverse effects on polymerization shrinkage might be decreased. As a result, microleakage might be improved. $2\;mm\;{\times}\;2\;mm\;{\times}\;2\;mm$ cavities with occlusal margins in enamel and gingival margins in dentin were prepared on buccal and lingual surfaces of 40 extracted human premolars. Prepared teeth were randomly divided into four groups and restored with Clearfil SE bond (Kuraray, Japan) and one of experimental composite resins; EX1, Experimental composite resin1 (Bis-M-GMA/TEGDMA = 95/5 wt%, 40 mm nanofillers); EX2, Experimental composite resin2 (Bis-M-GMA/TEGDMA = 95/5 wt%, 20 mm nanofillers); EX3, Experimental composite resin3 (Bis-GMA/TEGDMA = 70/30 wt%, 40 nm nanofillers); and Filtek Z250 (3M ESPE, USA) was filed as a control group. The restored teeth were thermocycled, and immersed in 2% methylene blue solution for 24 hours. The teeth were sectioned buccolingually with a low speed diamond saw and evaluated for microleakage under stereomicroscope. The data were statistically analyzed by Pearson Chi-Square test and Fisher Exact test (p = 0.05). The microleakage scores seen at the enamel margin were significantly lower than those of dentin margin (p = 0.007). There were no significant differences among the composite resins in the microleakage scores within each margin (p > 0.05). Bis-M-GMA, a new resin monomer having low viscosity, might in part replace high viscous Bis-CMA and might improve the quality of composite resin.

Complete Myocardial Revascularization Utilizing Parallel Secluential Anastomoses (Parallel sequential anastomosis를 이용한 관상동맥 우회수술의 성적)

  • 박계현;김관민
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.647-655
    • /
    • 1997
  • We evaluated the feasibility and safety of this method by reviewing the early outcome of the patients who underwent coronary artery bypass grafting(CABG) utili ing parallel sequential anastomoses with saphenous vein grafts, comparing with the outcome of the patients revascularized with grafts having only single distal anastomosis. During the one-year period of 1995, a total of 79 patients underwent isolated CABG, among whom 39 patients with sequential vein grafts(sequential group) and 40 patients without sequential grafts(non-sequential group). There was no difference between the two groups in terms of preoperative status, except in the extent of the coronary disease; 87.2% of the sequential group and 45.0% of the non-sequential group had left main andlor triple vessel involvement. 318 distal coronary anastomoses were done; 198 for the sequential group(5.1/patient) and 120 for the non-sequential group(3.0/patient). In the sequential group, the mean durations of cardiopulmonary bypass and aortic clamp per one distal anastomosis were 33.5 and 21.1 minutes, respectively. In the non-sequential group, these were 41.8 and 22.7 minutes. There were two operative deaths, both in the non-sequential group. There was no difference in the incidence of postoperative complications including myocardial infarction. During the follow-up period(2 to 15 months), 8 patients(3 in the sequential and 5 in the nonsequential group) complained of residual or recurrent angina. Comparison of preoperative and postoperative ."'Thallium myocardial perfusion scans in 30 patients showed improved or normal perfusion reserve in 83.3% of segments bypassed with sequential grafts and 82.5% of segments bypassed with non-sequential graft(5), These results show that, utilizing parallel sequential anastomoses with saphenous vein grafts, we could achieve satisfactory short-term clinical results in patients with extensive coronary stenoses. So, we conclude that this technique is a safe, technically feasible strategy for CABG, which can achieve the aim of complete myocardial revascularization with a limited length of graft.raft.

  • PDF

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement (하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구)

  • Lim, Ju-Eun;Lim, Won-Hee;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.397-406
    • /
    • 2008
  • Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.